• Title/Summary/Keyword: Maximum Time

Search Result 9,598, Processing Time 0.036 seconds

Long-Term Performance of High Strength Concrete

  • 최열;강문명
    • 콘크리트학회논문집
    • /
    • 제16권3호
    • /
    • pp.425-431
    • /
    • 2004
  • This paper describes an experimental investigation of how time-dependent deformations of high strength concretes are affected by maximum size of coarse aggregate, curing time, and relatively low sustained stress level. A set of high strength concrete mixes, mainly containing two different maximum sizes of coarse aggregate, have been used to investigate drying shrinkage and creep strain of high strength concrete for 7 and 28-day moist cured cylinder specimens. Based upon one-year experimental results, drying shrinkage of high strength concrete was significantly affected by the maximum size of coarse aggregate at early age, and become gradually decreased at late age. The larger the maximum size of coarse aggregate in high strength concrete shows the lower the creep strain. The prediction equations for drying shrinkage and creep coefficient were developed on the basis of the experimental results, and compared with existing prediction models.

열화상 기술에 의한 M.C 나일론의 내부 결함에 대한 평가 (The Estimation of Defect of Mono Cast Nylon by Infrared Thermography)

  • 한정섭
    • 한국해양공학회지
    • /
    • 제23권2호
    • /
    • pp.81-86
    • /
    • 2009
  • Infrared thermography was used to determine the location, size, and depth of defects under the surface of M.C nylon. Defects were created in a specimen by back-drilling circular holes. These defects were located at the maximum temperature difference that occurred. The sizes of the defects could be calculated by means of the full width at half of the maximum temperature difference. The depth of a defect could be calculated by the peak time and the maximum temperature difference. The maximum temperature difference between a defect and normal part was decreased with the depth of the defect. And the peak time also slowly appeared with the depth of the defect.

낙동강 하구해역의 식물플랑크톤 극대역 변동에 관한 수직시뮬레이션 -I. 식물플랑크톤 극대역 변동 현황- (The numerical simulation on variation of phytoplankton maximum region in the estuary of Nakdong river -I. The state of variation of phytoplankton maximum region-)

  • 이대인
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.369-374
    • /
    • 2000
  • The estuary of Nakdong river is very influenced by the freshwater contained nutrients and organic materials. The response results of these influences are eutrophication and red tide outbreak in this region. Concentration of chlorophyll a was 0.78~62.55$\mu\textrm{g}$/L in February 1.20~21.29$\mu\textrm{g}$/L in April 1.88~188.35$\mu\textrm{g}$/L in June and 0.78~11.21$\mu\textrm{g}$/L in August respectively. The decrease of chlorophyll a is considered that residence time is shorten by increase of freshwater discharge and unfavorable growth condition of phytoplankton is created by diffusion of low salinity and increase of turbidity. The phytoplankton maximum region located inner side of this estuary during winter season whereas it was moved to outer side when mean discharge of the Nakdong risver was increased, Therefore the variation of phytoplankton maximum region was affected by input discharge from the Nakdong river basin.

  • PDF

Maximum penalized likelihood estimation for a stress-strength reliability model using complete and incomplete data

  • Hassan, Marwa Khalil
    • Communications for Statistical Applications and Methods
    • /
    • 제25권4호
    • /
    • pp.355-371
    • /
    • 2018
  • The two parameter negative exponential distribution has many practical applications in queuing theory such as the service times of agents in system, the time it takes before your next telephone call, the time until a radioactive practical decays, the distance between mutations on a DNA strand, and the extreme values of annual snowfall or rainfall; consequently, has many applications in reliability systems. This paper considers an estimation problem of stress-strength model with two parameter negative parameter exponential distribution. We introduce a maximum penalized likelihood method, Bayes estimator using Lindley approximation to estimate stress-strength model and compare the proposed estimators with regular maximum likelihood estimator for complete data. We also introduce a maximum penalized likelihood method, Bayes estimator using a Markov chain Mote Carlo technique for incomplete data. A Monte Carlo simulation study is performed to compare stress-strength model estimates. Real data is used as a practical application of the proposed model.

농도 불균일 LPG-공기 혼합기체의 폭발특성 (Explosion Characteristics of Nonhomogeneous LPG-Air Mixtures)

  • 배정일;김영수;서용칠;신창섭
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.114-119
    • /
    • 1993
  • The explosion characteristics of nonhomogeneous LPG-Air mixtures was measured in a cylindrical vessel and a pipe. The maximum explosion pressure, the maximum rate of explosion pressure rise, and the flame propagation velocity were measured and compared with that of homogeneous explosion by changing the effective factors on the explosion of nonhomogeneous mixtures such as pressure difference, effusion time and delay time. Explosion was occured even in the lower concentration than the lean flammability limit of mixture. The maximum explosion pressure was increased with increase of LPG concentration, however, the maximum explosion pressure rise was not in the nonhomogeneous explosion. An d the flame propagation velocity was decreased with nonhomogeneity, however, the maximum explosion pressure was always above 0.7kg/$\textrm{cm}^2$.

  • PDF

각종 체온계의 구강체온측정에 관한 실험적 비교연구 -외제화씨 체온계, 전자체온계 및 국산 섭씨체온계에 의한 측정온도와 측정시간의 비교- (COMPARATIVE EXPERIMENTAL STUDY ON MEASUREMENT OF ORAL TEMPERATURE WITH DIFFERENT KINDS OF CLINICAL THERMOMETERS -comparison of Oral Temperature and Oral Placement Time among Fahrenheit Glass Thermometer, Electric Thermometer, Yu II centigrade Glass Thermometer, and Kuk II centigrade Glass Thermometer-)

  • 윤정숙
    • 대한간호학회지
    • /
    • 제4권2호
    • /
    • pp.93-106
    • /
    • 1974
  • The purposes of this study are to identify the necessity of utilization of electric thermometer, to determine the difference of clinical thermometers to reach maximum or optimum temperature, and to determine the length of time necessary for temperature taking, with Fahrenheit thermometer, electric thermometer, Yu Ⅱ centigrade thermometer, and Kuk ll centigrade thermometer. The first and second comparative Experiments were' conducted from August 25 through September 30, 1973. In the first experiment, Fahrenheit thermometer, which had been accurately teated two times, and electric thermometer have been utilized. These two kinds of thermometers were inserted simultaneously under the central area of the tongue and the mouth kept closed while thermometers were in place. All temperature readings were done at one minute interval until leaching-maximum temperature. These procedures were repeated one hundred times and the data were-analyzed statistically by means of the t-test. In the second experiment, Fahrenheit thermometer, which had been accurately tested two. times, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer have been utilized. These three kinds of thermometers were inserted simultaneously under the central area of the. tongue and the mouth kept closed while thermometer were in place. All temperature readings were done at one minute interval until reaching maximum temperature. These procedures were. repeated one hundred times and the data were analyzed statistically by means of the F-ratio Under the eight hypotheses designed for this study, the findings obtained are as follows: 1. There were no significant differences in the maximum temperature between Fahrenheit thermometer and electric thermometer. The mean maximum temperature for Fahrenheit thermometers was 37.06℃ and for electric thermometer was 37.09℃. 2. The placement time to reach maximum temperature taken by Fahrenheit thermometer was significantly shorter than that by electric thermometer. The mean placement time for Fahrenheit thermometers was 4.04 minutes, for electric thermometer was 5.52 minutes. In the case of Fahrenheit thermometers, 45 to 77 percent after 3 to 5 minutes, over 90 Percent after 7 minutes, and 100 percent after 10 minutes, had reached optimum temperature. When the electric thermometer was used, 23 to 54 percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 percent after 12 minutes, had reached optimum temperature. 5. There ware no significant differences in the maximum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer. The mean maximum temperature for Fahrenheit thermometers was 36.67℃, for Yu Ⅱ centigrade thermometer, was 33.73℃, and for Kuk Ⅱ centigrade thermometers was 37.76℃. 6. There were no significant differences in placement time to reach maximum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade Thermometer, and Kuk Ⅱ centigrade thermometer. The mean placement time (or Fahrenheit thermometers was 7.77 minutes, for Yu Ⅱ centigrade thermometers was 7.25 minutes, and Kuk Ⅱ centigrade thermometers was 7.25 minutes. In the case of Fahrenheit thermometers, 8 to 24 percent after 3 to 5 minutes, over 90 percent after 11 minutes, and 100 percent after 13 minutes, had reached maximum temperature. When the Yu Ⅱ centigrade thermometer was used, 10 to 27 percent after 3 to 5 minutes, over 90 percent after 11 minutes, an8 103 percent after 13 minutes, had reached maximum temperature. When the Kuk Ⅱ centigrade thermometer was used, 11 to 27 Percent after 3 to 5 minutes, over 90 percent after 11 minutes, and 100 percent after 12 minutes, had reached maximum temperature. 7. There were no significant differences in the optimum temperature(the maximum temperature minus 0.1℃) among fahrenheit thermometer, Yu Ⅱcentigrade thermometer, and Kuk Ⅱ centigrade thermometer. The mean optimum temperature for Fahrenheit thermometers was 36.60℃, for Yu Ⅱ centigrade thermometers was 36.69℃, and Kuk Ⅱ centigrade thermometers was 36.69℃. 8. There were no significant differences in placement time to reach optimum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer The mean placement time for Fahrenheit thermometers was 5.70 minutes, for Yu Ⅱ centigrade thermometers was 5.54 minutes, and for Kuk Ⅱ centigrade thermometers was 5.28 minutes. In the case of Fahrenheit thermometers, 21 to 49 percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 percent after 12 minutes, had reached optimum temperature. When the Yu Ⅱ centigrade thermometer was used, 23 to 51 percent after 3 to 5 minutes over 90 percent after 10 minutes, and 100 percent after 12 minutes, had reached optimum temperature. When the Kuk Ⅱ centigrade Thermometer was used, 23 to 57 Percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 Precent after 11 minutes, had reached optimum temperature.

  • PDF

Time optimal trajectory planning for a robot system Under torque and impulse constraints.

  • Cho, Bang-Hyun;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1402-1407
    • /
    • 2004
  • Moving a fragile object from an initial point to a goal location in minimum time without damage is pursued in this paper. In order to achieve the goal, first of all, the range of maximum acceleration and velocity are specified, which the manipulator can generate dynamically on the path that is planned a priori considering the geometrical constraints. Later, considering the impulsive force constraint of the object, the range of maximum acceleration and velocity are going to be obtained to keep the object safe while the manipulator is carrying it along the curved path. Finally, a time-optimal trajectory is planned within the maximum allowable range of the acceleration and velocity. This time optimal trajectory planning can be applied for real applications and is suitable for not only a continuous path but also a discrete path.

  • PDF

Packet Scheduling Algorithm Considering Maximum Delay Tolerance for HSDPA System

  • Hur, Soojung;Jakhongil, Narzullaev;Park, Yong-Wan
    • 대한임베디드공학회논문지
    • /
    • 제8권6호
    • /
    • pp.311-318
    • /
    • 2013
  • In this paper, we consider a new packet scheduling algorithm for real-time traffic in the HSDPA system that has been introduced for the WCDMA system, in order to provide high transmission rates. The objective of the design is to meet the maximum tolerable delay and consider channel assignment based on the received SIR for real-time traffic users. The proposed scheduling algorithm shows that the users are ranked by the ratios of the bits in the buffer to the residual time for transmission as priority order; then the ranked users are assigned certain number of channels based on the SIR value table. The simulation results show that the proposed algorithm can provide a lower packet drop rate, and satisfy real time quality of service (QoS) requirements.

시간/비용의 트레이드-오프를 고려한 2목적 스케쥴링 문제 (A Bicriterion Scheduling Problem with Time/Cost Trade -offs)

  • 정용식
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 1998년도 공동추계학술대회 경제위기 극복을 위한 정보기술의 효율적 활용
    • /
    • pp.731-740
    • /
    • 1998
  • This paper discusses a brcriterion approachto sequencing with time/cost trade-offs. The first problem is to minimize the total flow time and the maximum tardiness. And second is to the maximum tardiness and resource allocation costs. This approach , which produces an efficient frontier of possible schedules, has the advantage that it does not require the sequencing criteria to be measurable in the same units as the resource allocation cost. The basic single machine model is used to treat a class of problems in which the sequencing objective is to minimize the maximum completion penalty. It is further assumed that resource allocation costs can be represented by linear time/cost function.

A JOINT DISTRIBUTION OF TWO-DIMENSIONAL BROWNIAN MOTION WITH AN APPLICATION TO AN OUTSIDE BARRIER OPTION

  • Lee, Hang-Suck
    • Journal of the Korean Statistical Society
    • /
    • 제33권2호
    • /
    • pp.245-254
    • /
    • 2004
  • This paper derives a distribution function of the terminal value and running maximum of two-dimensional Brownian motion {X($\tau$) = (X$_1$($\tau$), X$_2$ ($\tau$))', $\tau$ 〉0}. One random variable of the joint distribution is the terminal time value, X$_1$ (T). The other random variable is the maximum of the Brownian motion {X$_2$($\tau$), $\tau$〉} between time s and time t. With this distribution function, this paper also derives an explicit pricing formula for an outside barrier option whose monitoring period starts at an arbitrary date and ends at another arbitrary date before maturity.