• 제목/요약/키워드: Maximum Heat Rate

검색결과 643건 처리시간 0.034초

Collins 내동기의 최적 설계조건 (Optimum Design Condition of the Collins Cryocooler)

  • 이상원;김수연;정평석
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.183-190
    • /
    • 1992
  • The Collins cryocooler is numerically analysed with the optimization technique, and the optimum operating and design conditions are searched. This paper shows that liquefied helium quantity has an external maximum w.r.t. the total mass flow rate, the mass flow rates through expander and the capacities of heat exchangers. The liquefied helium quantity increases as the compressor exit pressure of the cryocooler does. The maximum quantity of liquefied helium and the maximum coefficient of performance have been found to exist in extremum, depending on the ratios of each heat exchanger capicities to the total one. At the optimum condition, the capacity of heat exchanger in high temperature region is larger than that in low temperature region.

  • PDF

복사열 증가에 따른 소나무 생엽의 열적특성 분석 (Thermal Characteristics of Living Leaves in Pinus Densiflora with Heat Flux)

  • 박영주;이해평
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.75-82
    • /
    • 2010
  • 본 연구에서는 화재강도에 따른 산림연료의 연소특성을 고찰하기 위하여 산불에 가장 취약한 소나무 생엽을 대상으로 복사열을 변수(25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$)로 하여 연소특성 실험을 수행하였다. 콘칼로리미터 장비를 이용하여 착화특성, 발열 특성, 발연량 및 CO, $CO_2$ 방출특성, 중량감소특성 등을 분석하였다. 60.66% 수분을 함유한 소나무 생엽은 25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$ 복사열에서 착화가 일어나지 않았으며, 복사열 크기가 클수록 발열량과 열방출율은 2배 빠른 시간에 급격하게 최대값에 도달하고 최대값은 2배 정도 높은 것으로 나타났다. 발연량은 복사열 크기가 작을수록 불완전 연소로 인한 연기방출량은 많은 것으로 나타났다. CO 및 $CO_2$ 방출량은 복사열이 증가할수록 최대값이 급격히 높고, 빠른 시간에 최대값에 도달하는 것으로 나타나 복사열이 증가할수록 탄소산화물은 많은 것으로 나타나 산불발생 시 대형산불의 경우 많은 양의 CO와 $CO_2$를 방출할 것으로 사료된다.

자동차 배기가스 유량 및 온도 변화에 따른 열전발전용 열교환기 발열량 특성에 관한 연구 (Thermal Caracteristics of the Automobile Exhaust gas based Heat exchanger with various Exhaust gas Temperature and Mass flow rate)

  • 김대완;기한 에카나야케;이무연
    • 한국산학기술학회논문지
    • /
    • 제19권2호
    • /
    • pp.15-20
    • /
    • 2018
  • 본 논문은 자동차 열전발전용 열교환기에서 배기가스의 유량과 온도 변화에 따른 발열량 특성을 수치적으로 연구하였다. 자동차 열전발전용 열교환기는 내부에 핀을 설치하여 자동차 배기가스에서 나오는 열에너지를 열전소자로 최대 값을 전달할 수 있도록 하였으며, 상용 프로그램인 CAD를 이용하여 설계하였다. 그리고 배기가스의 유량과 온도 변화에 따른 열교환기 발열량 특성을 분석하기 위하여 상용 프로그램인 ANSYS CFX v17.0을 이용하여 배기가스 유량은 0.01, 0.02, 0.03 kg/s로 변화시키고, 배기가스 온도는 400, 450, 500, 550, $600^{\circ}C$로 변화시켜 수치해석 하였다. 결론적으로 열교환기의 입구 측과 출구 측 배기가스 압력 차는 배기가스의 유량에 따라 결정된다. 배기가스 유량이 증가하면 열교환기 입구 측과 출구 측 압력차는 증가하지만, 열교환기 입구 측과 출구 측 배기가스 압력차는 배기가스 온도에 따라 변하지 않는다. 따라서 열교환기 표면 온도를 최대 값으로 얻기 위해서는 배기가스 유량은 낮추고, 배기가스 온도는 높여야 한다는 결론을 도출하였다.

가정용 열병합 발전을 위한 스털링 엔진의 열원 온도 및 냉각수 유량에 따른 성능 실험 (Performance Measurements of A Stirling Engine for Household Micro Combined Heat and Power with Heat Source Temperatures and Cooling Flow Rates)

  • 심규호;김민기;이윤표;장선준
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2015
  • A Beta-type Stirling engine is developed and tested on the operation stability and cycle performance. The flow rate for cooling water ranges from 300 to 1500 ml/min, while the temperature of heat source changes from 300 to $500^{\circ}C$. The internal pressure, working temperatures, and operation speed are measured and the engine performance is estimated from them. In the experiment, the rise in the temperature of heat source reduces internal pressure but increases operation speed, and overall, enhances the power output. The faster coolant flow rate contributes to the high temperature limit for stable operation, the cycle efficiency due to the alleviated thermal expansion of power piston, and the heat input to the engine, respectively. The experimental Stirling engine showed the maximum power output of 12.1 W and the cycle efficiency of 3.0 % when the cooling flow is 900 ml/min and the heat source temperature is $500^{\circ}C$.

승온속도 및 최고온도 유지시간이 간벌재로 제조된 우드세라믹의 성질에 미치는 영향 (Effect of Heating Rate and Keeping Time at Maximum Temperature on the Properties of Woodceramics Made from Thinned Logs)

  • 오승원;변희섭
    • Journal of the Korean Wood Science and Technology
    • /
    • 제33권3호통권131호
    • /
    • pp.38-44
    • /
    • 2005
  • 소나무, 낙엽송 및 잣나무 간벌재로 톱밥보드를 만든 후 소성시 승온속도와 최고온도에서 유지시간을 달리하여 우드세라믹을 제조하고 그 물성을 조사하였다. 승온속도가 빠를수록 밀도 및 두께감소율은 감소하였고 길이감소율 및 중량 감소율은 증가하였다. 최고온도에서 유지시간이 증가할수록 길이감소율 및 두께감소율은 증가하였다. 열전도성은 승온속도 $2^{\circ}C/min$와 최고온도에서 유지시간 2시간일 때의 조건으로 제조된 우드세라믹이 가장 우수하였다.

정상 중력장에서 낮은 스트레인율을 갖는 대향류 비예혼합화염의 소화한계 (Extinction Limits of Low Strain Rate Counterflow Nonpremixed Flames in Normal Gravity)

  • 오창보;최병일;김정수;;박정
    • 대한기계학회논문집B
    • /
    • 제29권9호
    • /
    • pp.997-1005
    • /
    • 2005
  • The extinction characteristics of low strain rate normal gravity (1-g) nonpremixed methane-air flames were studied numerically and experimentally. A time-dependent axisymmetric two-dimensional (2D) model considering buoyancy effects and radiative heat transfer was developed to capture the structure and extinction limits of 1-g flames. One-dimensional (1D) computations were also conducted to provide information on 0-g flames. A 3-step global reaction mechanism was used in both the 1D and 2D computations to predict the measured extinction limit and flame temperature. A specific maximum heat release rate was introduced to quantify the local flame strength and to elucidate the extinction mechanism. Overall fractional contribution by each term in the energy equation to the heat release was evaluated to investigate the multi-dimensional structure and radiative extinction of 1-g flames. Images of flames were taken for comparison with the model calculation undergoing extinction. The two-dimensional numerical model was validated by comparing flame temperature profiles and extinction limits with experiments and ID computation results. The 2D computations yielded insight into the extinction mode and flame structure of 1-g flames. Two combustion regimes depending on the extinction mode were identified. Lateral heat loss effects and multi-dimensional flame structure were also found. At low strain rates of 1-g flame ('Regime A'), the flame is extinguished from the weak outer flame edge, which is attributed to multi-dimensional flame structure and flow field. At high strain rates, ('Regime B'), the flame extinction initiates near the flame centerline due to an increased diluent concentration in reaction zone, which is the same as the extinction mode of 1D flame. These two extinction modes could be clearly explained with the specific maximum heat release rate.

막냉각량 및 작동점 변화가 액체로켓 칼로리미터의 열유속에 미치는 영향 (Parametric Study on Heat Flux Characteristics of a Sub-scale Calorimeter)

  • 김종규;이광진;서성현;한영민;최환석;조원국
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.346-350
    • /
    • 2005
  • 연소압 50bar 이상의 연소조건에서 반복 사용이 가능하도록 제작된 물냉각형 칼로리미터에서 막냉각량 및 작동점의 변화 시 열유속의 특성을 알아보았다. 분사기 헤드와 칼로리미터 사이에 12개의 오리피스를 갖는 막냉각 링이 삽입된다. 칼로리미터는 연소실부와 노즐부로 구성되어 있으며, 총 19개의 냉각 채널로 구성되어 있다. 설계점 연소시험 시 막냉각량이 주 연료의 10.5% 유량일 때, 막냉각량이 없는 경우보다 노즐목에서의 최대 열유속은 약 30% 감소되었고, 막냉각량이 없는 경우, 탈설계점(OD3)이 설계점에 비해 노즐목에서의 최대 열유속이 약 31% 증가 하였다.

  • PDF

대심도터널 화재 안전 설계를 위한 승용차의 열방출률 및 화재전파 특성에 관한 연구 (A study of the HRR and fire propagation phenomena for the fire safety design of deep road tunnel)

  • 유용호;권오상
    • 한국터널지하공간학회 논문집
    • /
    • 제12권4호
    • /
    • pp.321-328
    • /
    • 2010
  • 본 연구에서는 최근 국내 도심지 대심도 지하교통터널 계획과 함께 중요성이 대두되고 있는 터널내 화재 안전 설계에 가장 기본적인 설계 요소인 자동차의 열방출률을 제시하고자 실물화재실험을 실시하였다. 산소소모율법을 적용한 라지스케일칼로리미터를 이용하여 승합차의 열방출률을 측정하였으며, 또한 두 대의 승용차를 인접시켜 터널 정체시 화재 전파 특성을 파악 하였다. 그 결과 승합차의 최대 열방출률은 5.9 MW를 나타내었으며, 일산화탄소는 최대 482 ppm이 방출되었다. 두 대의 승용차의 화재 전파 특성 실험의 경우 화재 발생 후 약 3분 30초 경과부터 인접 승용차에 화재 전파가 시작되어, 15분 경과 후에는 완전한 화재로 발달하였다. 최대 발열량은 9 MW를 나타내었다. 이러한 실물화재실험에서 얻어낸 결과는 향후 수치해석시 중요한 입력 자료로 이용됨과 동시에 터널의 방재설비 설계에 유용하게 적용 될 수 있을 것이다.

고감성 의류용 Nylon/PP 온감 니트 소재의 물성 (The Physical Property of Nylon/PP Warm-up Knitted Fabric for High Emotional Garment)

  • 김현아;장홍원;허경;김승진;권상준
    • 한국염색가공학회지
    • /
    • 제26권1호
    • /
    • pp.22-31
    • /
    • 2014
  • This study investigated the physical properties of warm up yarns and their knitted fabrics including the dye affinity and color fastness to washing of these knitted fabrics according to the various dyeing times and temperatures on dyeing process. The results were summarized as follows. The tenacity of Nylon/PP warm-up yarn was 4g/d and breaking strain was 4.5%. The wet and dry thermal shrinkages were higher than those of PET warm-up yarn. The maximum heat flow rate(Qmax) of Nylon/PP warm-up knitted fabric was lower than that of PET warm-up knitted fabric and heat keeping rate(a) of Nylon/PP warm-up knitted fabric was higher as 47% than that of PET warm-up knitted fabric. It was shown that the shape retention and wearing comfort of Nylon/PP warm-up knitted fabric were better than those of PET warm-up knitted fabric. The dye-affinity(K/S) of Nylon/PP warm-up knitted fabric showed maximum value at the dyeing condition of 40minute or 50minute dyeing time with $80^{\circ}C$ dyeing temperature, but PET warm-up knitted fabric showed maximum value at the 30minute or 40minute with $110^{\circ}C$ dyeing temperature. Finally, the color fastness to washing of Nylon/PP warm-up knitted fabric showed good value as between 4 and 5 grade.

멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 - (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results -)

  • 김종진;최규성;기호충;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF