• 제목/요약/키워드: Maximum Dose

검색결과 1,206건 처리시간 0.024초

A STUDY FOR DOSE DISTRIBUTION IN SPENT FUEL STORAGE POOL INDUCED BY NEUTRON AND GAMMA-RAY EMITTED IN SPENT FUELS

  • Sohn, Hee-Dong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.174-182
    • /
    • 2011
  • With the reactor operation conditions - 4.3 wt% $^{235}U$ initial enrichment, burn-up 55,000 MWd/MTU, average power 34 MW/MTU for three periods burned time for 539.2 days per period and cooling time for 100 hours after shut down, to set up the condition to determine the minimum height (depth) of spent fuel storage pool to shut off the radiation out of the spent fuel storage pool and to store spent fuels safely, the dose rate on the specific position directed to the surface of spent fuel storage pool induced by the neutron and gamma-ray from spent fuels are evaluated. The length of spent fuel is 381 cm, and as the result of evaluation on each position from the top of spent fuel to the surface of spent fuel storage pool, it is difficult for neutrons from spent fuels to pass through the water layer of maximum 219 cm (600 cm from the floor of spent fuel storage pool) and 419 cm (800 cm from the floor of spent fuel storage pool) for gamma-ray. Therefore, neutron and gamma-ray from spent fuels can pass through below 419 cm (800 cm from the floor) water layer directed to the surface of spent fuel storage pool.

CT의 선량 감소를 위한 sinogram 보간 기법 (A Method for Sinogram Interpolation for Reducing X-ray Dose)

  • 김재민;이기승
    • 한국통신학회논문지
    • /
    • 제37권7C호
    • /
    • pp.601-609
    • /
    • 2012
  • 본 논문에서는 전산화 단층촬영 시 스캔 시간의 단축 및 환자의 X-Ray 피폭량을 줄이기 위한 방법으로 샘플링 빈도를 줄이고 적은 수의 view를 이용하여 단면 영상을 재구성하는 방법에 대해 연구하였다. 부족한 view로 인해 단면 영상에 발생하는 방사형의 직선형 왜곡(streak artifact) 를 억제하기 위하여 본 논문에서는 sinogram 보간기법을 적용하였다. 인접 view간 영상 특성(밝기, 그라디언트, 픽셀거리)을 기반으로 sinogram 픽셀 간의 매칭을 수행하고 그 결과를 기반으로 변화패턴을 추적하여 sinogram을 보간하도록 하였다. Numerical 팬텀과 자체 제작된 팬텀을 이용하여 제안된 기법을 검증하였다. 선형 보간 기법에 비해 재구성된 단면영상의 디테일을 유지하면서 왜곡이 감소하는 것이 관찰되었으며, PSNR면에서 최대 5%의 향상이 있는 것을 확인하였다.

편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰 (Study of photon beam quality tool at magnetic field change in bending magnet)

  • 김정호;유세종;박명철;배석환;김기진
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

부정형 조사면에서의 TLD를 이용한 방사선 흡수선량 측정 (Dosimetry of Irregular Field Using Thermoluminescence Dosimetry)

  • 이종영;박경란;김계준
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.263-267
    • /
    • 1994
  • In clinical radiotherapy, the use of wide and irregular field techniques frequently results in considerable tumor dose inhomogeneity because of, the variation in physical characteristics of irradiated volumes. This report describes an analysis of the dosimetry of the irregular fields such as radiation fields for Hodgkin's disease(mantle field), esophageal cancer, and lung cancer when a 6 MV and a 15 MV linear accelerators are utilized. Doses were measured in a Rando phantom using methods of thermoluminescence dosimetry(TLD), and were calculated by radiotherapy planning computer system with the Clarkson's method for calculation of a irregular field. A dose variation of $5-22\%,\;6-9\%,\;6-14\%$ were found in the mantle field, esophageal cancer field, lung cancer field respectively. Higher doses occurred in the superior portion of the irregular field. The sites of maximum dose variation were the supraclavicular and the upper spinal cord region. To adjust for these substantial differences, a compensator or a shrinking field technique should be adopted.

  • PDF

Al합금에서 질소이온주입에 의한 질화물 형성과 기계적 특성 향상 (The Formation of Nitride and Enhancement of Mechanical Properties of Al Alloy by Nitrogen Implantation)

  • 정재필;이재상;김계령;최병호
    • 한국표면공학회지
    • /
    • 제39권5호
    • /
    • pp.235-239
    • /
    • 2006
  • The aluminum nitride(AlN) layer on Al7075 substrate has been formed through nitrogen ion implantation process. The implantation process was performed under the conditions : 100 keV energy, total ion dose up to $2{\times}10^{18}\;ions/cm^2$. XRD analysis showed that aluminum nitride layers were formed by nitrogen implantation. The formation of Aluminum nitride enhanced surface hardness up to 265HK(0.02 N) from 150HK(0.02 N) for the unimplanted specimen. Micro-Knoop hardness test showed that wear resistance was improved about 2 times for nitrogen implanted specimens above $5\;{\times}\;10^{17}\;ions/cm^2$. The friction coefficient was measured by Ball-on-disc type wear tester and was decreased to 1/3 with increasing total nitrogen ion dose up to $1\;{\times}\;10^{18}ions/cm^2$. The enhancement of mechanical properties was observed to be closely associated with AlN formation. AES analysis showed that the maximum concentration of nitrogen increased as ion dose increased until $5\;{\times}\;10^{17}\;ions/cm^2$.

BREEDING EXPERIMENT ON MUTATION INDUCTION BY IRRADIATION (2) Effects of X-ray and Thermal Neutron Irradiation on Dry Seeds of Chinese Cabbage and Radish.

  • Kim, Dawng Woo;Kim, Yang Choon;Cho, Mi Kyung
    • Journal of Plant Biology
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 1962
  • 1) Germination rate was rather irregular than decreasing as increasing dose of radiation and there were no differences between Kyong-Sam and Chuong-Bang of Chinese cabbage. 2) In R1 generation, abnormal leaves from seedling of irradiated seeds were observed. These were more apparent in X-ray irradiation than in thermal neutron. 3) Seedling height was inhibited with increasing dose of X-ray and thermal neutrons. Growth inhibition was more remarkable in X-ray than in thermal neutron. Kyong-Sam demonstrated more sensitivity than Chyong-Bang in both X-ray and thermal neutron. 4) Seedling height produced from seeds subjected to thermal neutrons showed small variation around its mean value, while in X-irradiation there was a greater deviaton from the mean value. 5) Fertility was decreased as increasing with dose, while the frequency of abortive pollen was increased. There were variability of the fertility and frequency of abortive pollen among plants or branches of a plant. 6) The mutants were obtained more in thermal neutron irradiation than in X-ray. The types of mutations obtained in Chinese radish of R2 generation were abnormal leaf, densely glowing leaf, degeneration in growing point and dwarf. The maximum frequency of phenotypic mutations was abnormal leaf mutation.

  • PDF

에너지 구조재 적용을 위한 알루미늄/섬유강화 복합재의 표면처리 (Surface Treatment of Aluminum/ Fiber- Reinforced Composites As Energy-Saving Light Structures)

  • 이경엽;강용태;양준호
    • 한국표면공학회지
    • /
    • 제34권1호
    • /
    • pp.56-61
    • /
    • 2001
  • In this work, the surface treatment of aluminum/composites (graphite-epoxy composites) was investigated. The surface of composites was treated by $Ar^{+}$ ion beam under oxygen environment. The surface of aluminum was treated by DC plasma. The optimal condition of surface treatment for the composites was determined by measuring the contact angle as a function of ion dose. The optimal treatment condition of the aluminum was determined by measuring the contact angle and T-peel strength as a function of mixture ratio of acetylene gas to nitrogen gas. The mixture ratios used were 1:9, 3:7, 5:5, 7:3, and 9:1. The results showed that the contact angle of composites decreased from$ 81^{\circ}$ to $8^{\circ}$ as the ion dose increased from zero to $1$\times$10^{17}$ions/$\textrm{cm}^2$. The optimal condition of ion dose was $1$\times$10^{16}$ions/$\textrm{cm}^2$. The results also showed that the contact angle of aluminum was a minimum for the mixture ratio of 5:5. Similarly, the T-peel strength was a maximum for the mixture ratio of 5:5, which indicates that the optimal condition of mixture ratio of acetylene gas to nitrogen gas is 5:5.

  • PDF

Novel biological strategies to enhance the radiation therapeutic ratio

  • Kim, Jae Ho;Jenrow, Kenneth A.;Brown, Stephen L.
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.172-181
    • /
    • 2018
  • Successful anticancer strategies require a differential response between tumor and normal tissue (i.e., a therapeutic ratio). In fact, improving the effectiveness of a cancer therapeutic is of no clinical value in the absence of a significant increase in the differential response between tumor and normal tissue. Although radiation dose escalation with the use of intensity modulated radiation therapy has permitted the maximum tolerable dose for most locally advanced cancers, improvements in tumor control without damaging normal adjacent tissues are needed. As a means of increasing the therapeutic ratio, several new approaches are under development. Drugs targeting signal transduction pathways in cancer progression and more recently, immunotherapeutics targeting specific immune cell subsets have entered the clinic with promising early results. Radiobiological research is underway to address pressing questions as to the dose per fraction, irradiated tumor volume and time sequence of the drug administration. To exploit these exciting novel strategies, a better understanding is needed of the cellular and molecular pathways responsible for both cancer and normal tissue and organ response, including the role of radiation-induced accelerated senescence. This review will highlight the current understanding of promising biologically targeted therapies to enhance the radiation therapeutic ratio.

Change in radiation characteristics outside the SNF storage container as an indicator of fuel rod cladding destruction

  • Rudychev, V.G.;Azarenkov, N.A.;Girka, I.O.;Rudychev, Y.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3704-3710
    • /
    • 2021
  • The characteristics of the external radiation on the surface of the casks for spent nuclear fuel (SNF) storage by dry method are investigated for the case when the spatial distribution of SNF in the basket changes due to the destruction of the fuel rod claddings. The surface areas are determined, where the changes in fluxes of neutrons, produced by 244Cm actinide, and γ-quanta, produced by long-lived isotopes, are maximum in the result of the decrease in the height of the SNF area. Concrete (VSC-24) and metal (SC-21) casks are considered as examples. The procedure of periodic measurement of the dose rate of neutrons or γ-quanta at the specified points of the cask surface is proposed for identifying the fuel rod cladding destruction. Under normal operation, the decrease in the dose rate produced by neutrons as the function of SNF storage duration is determined by the half-life of 244Cm, and for γ-quanta - by the half-lives of long-lived SNF isotopes. Consequently, a stepwise change in the dose rate of neutrons or γ-quanta, detected by the measurements, as compared to the previous one, would indicate the destruction of the fuel rod claddings.

Enhancement of a mechanical property of metal sheaths (Cu and Nb) of MgB2 superconducting wires by E-beam irradiation

  • Kim, C.J.;Lee, T.R.;Jun, B.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.30-34
    • /
    • 2022
  • Effects of electron beam (EB) irradiation on the mechanical strength of Cu (conducting sheath) and Nb (diffusion barrier) of Cu/Nb/MgB2 superconducting was investigated. Wire- and tape-type Cu/Nb/MgB2 samples were irradiated at E-beam energy of 2.5 MeV and 5 mA and a maximum E-beam dose was 5×1017 e/m2. The hardness value of Cu and Nb region was measured by the Vickers micro-hardness method. In the case of the wire sample, the hardness of Cu and Nb increased proportionally as the dose was increased up to 5×1017 e/m2, whereas in the case of the tape sample, the hardness increased up to a dose of 0.5×1017 e/m2, and decreased slightly 5×1017 e/m2. The hardness increase of Cu and Nb is believed to be due to the decrease of the deformability of Cu and Nb due to the defects formed inside the materials by E-beam irradiation.