• Title/Summary/Keyword: Maxillary sinus augmentation

Search Result 117, Processing Time 0.024 seconds

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.

Do Certain Conditions Favor the Use of Autogenous Bone Graft Over Bone Substitutes for Maxillary Sinus Augmentation?

  • Lee, Ji-Hyun;Cho, Yeong-Cheol;Sung, Iel-Yong;Choi, Jong-Ho;Son, Jang-Ho
    • Journal of Korean Dental Science
    • /
    • v.12 no.2
    • /
    • pp.48-57
    • /
    • 2019
  • Purpose: To investigate whether there are specific surgical or clinical conditions where the use of autogenous bone (AB) is superior to the use of bone substitutes (BSs) for maxillary sinus floor augmentation (MSFA). Materials and Methods: We retrospectively analyzed 386 implants after MSFA in 178 patients. The implants were divided into five groups according to the sinus graft material used. Risk factors for implant failure in MSFA, and correlation between residual bone height (RBH) and graft materials in terms of implant survival were investigated. To investigate risk factors for implant failure in MSFA, implant survival according to graft materials, patients' sex/age, surgical site, RBH, healing period prior to prosthetic loading, staged- or simultaneous implantation with MSFA, the crown-to-implant ratio, prosthetic type, implant diameter, and opposite dentition were evaluated. Result: The cumulative 2- and 5-year survival rates of implants placed in the grafted sinus (independent of the graft material used) were 98.7% and 97.3%, respectively. None of the investigated variables were identified as significant risk factors for implant failure. There was also no statistical significance in implant survival between graft materials. Conclusion: There were no specific surgical conditions in which AB was superior to BSs in terms of implant survival after MSFA.

Clinical Comparative Study for Maxillary Sinus Augmentation Using Deproteinized Bovine Bone Mineral and Mineralized Allograft (탈단백우골과 비탈회 동종골을 사용한 상악동 거상술의 임상적 연구)

  • Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.442-446
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the clinical efficacy of popular bone graft materials mineralized allograft and deproteinized bovine bone mineral. Materials and Methods: One hundred seven implants of 78 patients, accompanied by sinus lift using the lateral window technique and simultaneous implantation, were sampled. In addition, some patients with severe systemic conditions were excluded. The initial bone heights of all patients ranged from 3-6 mm. All of the sample cases were treated at our hospital from January 2005 to January 2008. Techniques other than the lateral window technique were excluded, and only one graft material ($Tutoplast^{(R)}$ or Bio-$Oss^{(R)}$) was accepted for inclusion. $Tutoplast^{(R)}$ was used in 63 implants of 41 patients, whereas Bio-$Oss^{(R)}$) was chosen for the remaining 44 implants of 37 patients. The diameters of the particles used ranged from 0.25-1.0 mm, and the volume was 0.5-2 cc (mean, 1.5 cc). Results: The survival rate of the implant fixtures was 99.07% when the lateral window technique was used. Among all of the cases, cases in which $Tutoplast^{(R)}$ was used demonstrated a survival rate of 98.4%, whereas Bio-$Oss^{(R)}$) resulted in 100% survival. With respect to the alveolar bone height, no significant differences were detected between the two graft materials that failed. Conclusion: According to the result reported above, the two common materials for sinus augmentation do not have clinically significant difference. Rather, host factors, such as the height of residual bone, which could be disclosed during questioning patients' systemic conditions, might have greater effects on the prognosis.

Long-term evaluation of implant placed in sites grafed by lateral window approach on maxillary sinus;a 10-year retrospective study (측방 접근법에 의한 상악동 거상술을 이용하여 식립된 골내 임플란트의 10년간 후향적 연구)

  • Yon, Je-Young;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.691-704
    • /
    • 2007
  • Between 1997 May and 2007 May, One hundred and seventeen patients were treated. There were 129 cases of sinus elevation using a lateral window opening procedure and 258 implants placed simultaneously or delayed. The cumulative survival rate of the implants calculated. The implants were evaluated according to surgical site, quality and quantity of bone, graft material, membrane used, the length and diameter of the implant and complications. 1. The 10-year cumulative survival rate of the implants by sinus augmentation using lateral window approach was 96.90%. 2. There was no difference in the survival rate between the implant placed simultaneously with sinus elevation (one stage) and the procedure performed in the delayed procedure (two stage). 3. There was no difference in the survival rate according to the type and amount of graft materials. 4. There was no difference in the survival rate according to the implant site, bone quality and quantity. 5. There was no difference in the survival rate when the $CollaTape^{(R)}$ or Gore-Tex was placed in the window of the lateral wall. 6. There was no difference in the survival rate of the implant length and diameter. 7. The survival rate was as low as 75.00% when there were more than two complications. Implant placement with sinus augmentation using the lateral window approach is a predictable treatment method. Although the vertical height of residual ridge is insufficient and the quality of bone is poor, the normal survival rate of the implants would be expected if an appropriate graft material and membrane is used with greater effort to prevent complications.

Alveolar Ridge Preservation of Maxillary Molars for Implant Placement Without Sinus Lift Surgery: Case series (상악동 거상술을 동반하지 않는 치조제 보존술: 증례연구(Case series))

  • Cho, Hag-Yeon;Suh, Chang-Wan;Duong, Hieu Pham;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Koo, Ki-Tae;Fickl, Stefan;Park, Jung-Chul
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.220-235
    • /
    • 2018
  • Sinus lift procedure is frequently required for the maxillary molar implant placement. Previous studies have demonstrated alveolar ridge preservation (ARP) can maintain the dimensions of ridge height and width. However, there is a lack of studies which evaluated the effect of ARP to avoid sinus lift procedure. Purpose of this study is to describe a method reducing the need of sinus lift surgery by ARP in maxillary molar areas and to assess the feasibility clinically, radiologically and histologically. Ten maxillary molars in ten patients had severe vertical bone resorption with minimal residual bone height. They were considered having the high possibility of the necessity of sinus lift procedure for dental implant after the extraction. After extraction, open healing ARP with deproteinized bovine bone mineral mixed with 10% collagen and resorbable collagen membranes was performed. After sufficient healing, dental implants were placed, and evaluated clinically and radiologically. Histological observation was conducted just before the implantation in one patient. Implants were successfully placed without sinus lift in all ten cases. All the implants were restored with no sign of complications, and patients are now in a close follow-up up to 20 months post-loading. Histological observation showed minimal inflammatory reaction and newly formed bone was substantially noted. The ARP technique has successfully avoided the sinus lift surgeries. It appears that this procedure may improve the simplicity of the clinical process for the clinicians and reduce the discomfort of patients.

Retrospective clinical study on sinus bone graft and tapered-body implant placement

  • Kim, Jong-Hwa;Kim, Young-Kyun;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.77-84
    • /
    • 2013
  • Objectives: This study evaluated implant success rate, survival rate, marginal bone resorption of implants, and material resorption of sinus bone graft in cases wherein tapered body implants were installed. Materials and Methods: From September 2003 to January 2006, 20 patients from Seoul National University Bundong Hospital, with a mean age of 54.7 years, were considered. The mean follow-up period was 19 months. This study covered 50 implants; 14 implants were placed in the maxillary premolar area, and 36 in the maxillary molar area; 24 sinuses were included. Results: The success rate was 92%, and the survival rate was 96.0%. The mean amount of sinus augmentation was $12.35{\pm}3.27$ mm. The bone graft resorption rate one year after surgery was $0.97{\pm}0.84$ mm; that for the immediate implantation group was $0.91{\pm}0.86$ mm, and that for the delayed implantation group was $1.16{\pm}0.77$ mm. However, the difference was not statistically significant. The mean marginal bone resorption one year after restoration was $0.17{\pm}0.27$ mm (immediate group: $0.12{\pm}0.23$ mm; delayed group $0.40{\pm}0.33$ mm); statistically significant difference was observed between the two groups. Conclusion: Tapered body implant can be available in the maxillary posterior edentulous ridge which sinus bone graft is necessary.

Intra-sinus rigid fixation of a resorbable barrier membrane to repair a large perforation of the sinus membrane: a technical note

  • Won-Jun Joung;Seo-Hyoung Yun;Yongjin Kim;Yong-Seok Cho;Won-Woo Lee;Jin-Won Seo;Marco Tallarico;Kyung-Gyun Hwang;Chang-Joo Park
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.5
    • /
    • pp.297-303
    • /
    • 2023
  • A resorbable barrier membrane is commonly used for the repair of perforated sinus membranes during sinus lifting surgeries. However, repairing largescale perforations poses challenges for clinicians as the protection and isolation of graft material remain uncertain. With this technique, we aimed to prevent graft material loss and subsequent sinus-related complications using intra-sinus rigid fixation of the resorbable barrier membrane in cases with a large perforation of the sinus membrane.

Volumetric analysis of mucous retention cysts in the maxillary sinus: A retrospective study using cone-beam computed tomography

  • Hung, Kuofeng;Hui, Liuling;Yeung, Andy Wai Kan;Wu, Yiqun;Hsung, Richard Tai-Chiu;Bornstein, Michael M.
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.117-127
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the volumetric characteristics of mucous retention cysts(MRCs) in the maxillary sinus and to analyze potential associations of MRCs with dentoalveolar pathologies. Materials and Methods: Cone-beam computed tomography (CBCT) scans exhibiting bilateral maxillary sinuses that were acquired from January 2016 to February 2019 were initially screened. A total of 227 scans(454 sinuses) that fulfilled the inclusion criteria were included. The presence, location, and volumetric characteristics of the diagnosed MRCs were evaluated on CBCT images using the 3D-Slicer software platform. The presence of MRCs was correlated with potential influencing factors including age, sex, and dentoalveolar pathology. For MRCs located on the sinus floor, factors with a potential impact on the volume, surface, and diameter were analyzed. Results: An MRC was present in 130 (28.6%) of the 454 sinuses. Most MRCs were located on the sinus walls and floor. The mean MRC volume, surface, and diameter were 551.21±1368.04 mm3, 228.09±437.56 mm2, and 9.63±5.40 mm, respectively. Significantly more sinuses with associated endodontically treated teeth/periapical lesions were diagnosed with an MRC located on the sinus floor. For MRCs located on the sinus floor, endodontic status exhibited a significant association with increased volume, surface, and diameter. Conclusion: Periapical lesions might be a contributing factor associated with the presence and volume of MRCs located on the sinus floor. The 3D-Slicer software platform was found to be a useful tool for clinicians to analyze the size of MRCs before surgical interventions such as sinus floor elevation procedures.

Full mouth implant rehabilitation of a patient with ectodermal dysplasia after orthognathic surgery, sinus and ridge augmentation: a clinical report

  • Bayat, Mohammad;Khobyari, Mohammad Mohsen;Dalband, Mohsen;Momen-Heravi, Fatemeh
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.96-100
    • /
    • 2011
  • An 18-year-old male presented severe hypodontia due to hypohidrotic ectodermal dysplasia was treated with Le Fort I maxillary osteotomy with simultaneous sinus floor augmentation using the mixture of cortical autogenous bone graft harvested from iliac crest and organic Bio-Oss to position the maxilla in a right occlusal plane with respect to the mandible, and to construct adequate bone volume at posterior maxilla allowing proper implant placement. Due to the poor bone quality at other sites, ridge augmentation with onlay graft was done to construct adequate bone volume allowing proper implant placement, using tissue harvested from the iliac bone. Seven implants were placed in the maxilla and 7 implants were inserted in the mandible and screw-retained metal ceramic FPDs were fabricated. The two year follow up data showed that dental implants should be considered as a good treatment modality for patients with ectodermal dysplasia.

A cumulative survival rate of implants installed on posterior maxilla augmented using MBCP after 2 years of loading: A retrospective clinical study (MBCP를 이용하여 거상된 상악 구치부에 식립한 임플란트의 기능 후 2년 누적 생존율 - 후향적 임상 연구)

  • Kim, Min-Soo;Lee, Ji-Hyun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.669-678
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate 2 years cumulative survival rate of implants on augmented sinus area using MBCP, mixture of MBCP and ICB, and mixture of MBCP and autogenous bone by means of clinical and radiologic methods. Materials and Methods: In a total of 37 patients, 41 maxillary sinuses were augmented and 89 implant fixtures were installed simultaneously or after a regular healing period. The patients were divided in 3 groups: MBCP only, MBCP combined with ICB, MBCP combined with autogenous bone. After delivery of prosthesis, along 2 years of observation period, all implants were evaluated clinically and radiologically. And the results were as follows. Results: The results of this study were as follows. 1. A 2 year cumulative survival rate of implants placed with sinus augmentation procedure using MBCP was 97.75%. 2. Survival rate of implants using MBCP only was 97.62%, MBCP and ICB was 100%, MBCP and autogenous bone was 95%. There was no statistically significant difference between 3 groups. 3. Only 2 of 89 implants were lost before delivery of prosthesis, so it can be regarded as an early failure. And both were successfully restored by wider implants. Conclusion: It can be suggested that MBCP may have predictable result when used as a grafting material of sinus floor augmentation whether combined with other graft(ICB, autogenous bone) or not. And the diameter, length, location of implants did not have a significant effect on 2 year cumulative survival rate.