• Title/Summary/Keyword: MaxMin

Search Result 1,659, Processing Time 0.034 seconds

Bioequivalence of Cefaclor 375 mg SR Tablet (세파클러 375 mg서방정의 생물학적 동등성)

  • Lee, Shin Hwa;Yun, Min Hyuk;Choi, Kyung Eob;Kwon, Kwang Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.13 no.1
    • /
    • pp.13-17
    • /
    • 2003
  • This study was carried out to compare the bioavailability of $Ceclex^{(R)}$ SR TAB (test drug, cefaclor 375 mg/Tablet) with that of Ceclor $MR^{(R)}$ SR IAB (reference drug) and to estimate the pharmacokinetic parameters of cefaclor in healthy Korean volunteers. The bioavailability was examined on 24 healthy volunteers who received a single dose (375 mg) of each drug in the fasting state in a randomized balanced 2-way crossover design. After dosing, blood samples were collected for a period of 7 hours. Plasma concentrations of cefaclor were determined using HPLC with UV detection. The pharmacokinetic parameters $(AUC_{0-7h},\;C_{max},\;T_{max},\;AUC_{inf},\;K_e,\;t_{1/2},\;V_d/F,\;and\;CL/F)$ were calculated with non-compartmental pharmacokinetic analysis. The ANOVA test was utilized for the statistical analysis of the $T_{max}$, log-transformed $AUC_{0-7h$}$, log-transformed $C_{max},\;t_{1/2},\;V_d/F$, and $CL/F$. The ratios of geometric means of $AUC_{0-7h}\;and\;C_{max}$ between test drug End reference drug were $95.67\%\;(8.55\;vs\;8.18{\mu}g{\cdot}hr/ml)\;and\;103.86\%\;(2.85\;vs\;2.96{\mu}g/ml)$, respectively. The $T_{max}$ of test drug and reference drug was $2.56\pm0.15\;and\;2.23\pm0.13\;hrs,\;respectively.\;The\;90\%$ confidence intervals of mean difference of logarithmic transformed $AUC_{0-7h}\;and\;C_{max}$ were log0.90-log1.04 and log0.91-log1.13, respectively. It shows that the bioavailability of test drug is equivalent with that of reference drug.

  • PDF

Rats Lens Aldose Reductase Inhibitor Activities of Leguminous Seed Extracts

  • Kim, Byung-Su;Kim, Min-Jeong;Kim, Hye-Young;Ahn, Young-Joon;Lee, Hoi-Seon
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2001
  • The methanol extracts of 25 leguminous seeds in vitro were evaluated for inhibitory activities against lens aldose reductase of Sprague Dawley male rats. The responses varied with both leguminous seed and concentration used. At the concentration of 0.1 mg/mL, the methanol extracts from Amphicaraea edgeworthii, Canavalia lineata, Gylcine max var. solitae, Glycine max var. yagkong, Glycine max var. hooktae, Glycine max var. bangkong, Glycine max var. geumdu, Glycine max var. chungtae, Glycine max var. mejukong, Glycine soja, Phaseolus radiatus var. geodu, Vicia tetrasperma, Vigna angulasis, and Vigna sinensis inhibited enzyme activity by greatertha 60%. In following study, at the concentration of 0.01 mg/mL, the extracts of C. lineata and V. tetraspermahad relatively strong inhibitory activity against aldose reductase. Because of their potent inhibitory activities, the activity of each solvent fraction from C. lineata and V. tetrasperma was determined, and the potent activity was showed from chloroform and hexane fractions, respectively. {TEX}$IC_{50}${/TEX} values of C. lineata and V. tetrasperma were 0.004 and 0.006 mg/mL, respectively. As a naturally occurring therapeutic agent, leguminous seeds described could be useful for developing new agents of antidiabetic complications.

  • PDF

Microfluidic LOC System (Microfluidic LOC 시스템)

  • Kim, Hyun-Ki;Gu, Hong-Mo;Lee, Yang-Du;Lee, Sang-Yeol;Yoon, Young-Soo;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.906-911
    • /
    • 2004
  • In this paper, we used only PR as etching mask, while it used usually Cr/AU as etching mask, and in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. we designed microchannel size width max 10um, min 5um depth max 10um, reservoir size max 100um, min 2mm. Fabrication of microfluidic devices in glass substrate by glass wet etching methods and glass to glass fusion bonding. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive($4k{\Omega}{\cdot}cm$) wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571\Omega$ to $393\Omega$.

  • PDF

An acoustical analysis of speech of different speaking rates and genders using intonation curve stylization of English (영어의 억양 유형화를 이용한 발화 속도와 남녀 화자에 따른 음향 분석)

  • Yi, So Pae
    • Phonetics and Speech Sciences
    • /
    • v.6 no.4
    • /
    • pp.79-90
    • /
    • 2014
  • An intonation curve stylization was used for an acoustical analysis of English speech. For the analysis, acoustical feature values were extracted from 1,848 utterances produced with normal and fast speech rate by 28 (12 women and 16 men) native speakers of English. Men are found to speak faster than women at normal speech rate but no difference is found between genders at fast speech rate. Analysis of pitch point features has it that fast speech has greater Pt (pitch point movement time), Pr (pitch point pitch range), and Pd (pitch point distance) but smaller Ps (pitch point slope) than normal speech. Men show greater Pt, Pr, and Pd than women. Analysis of sentence level features reveals that fast speech has smaller Sr (sentence level pitch range), Sd (sentence duration), and Max (maximum pitch) but greater Ss (sentence slope) than normal speech. Women show greater Sr, Ss, Sp (pitch difference between the first pitch point and the last), Sd, MaxNr (normalized Max), and MinNr (normalized Min) than men. As speech rate increases, women speak with greater Ss and Sr than men.

Effect of Pilates Reformer Training on Gait Improvement of Subjects with Asymmetric Pelvic Rotation (필라테스 리포머 운동이 비대칭 골반 돌림을 가진 대상자의 보행 개선에 미치는 효과)

  • Moon, Ok-Kon;Han, Song-E
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.3
    • /
    • pp.271-278
    • /
    • 2013
  • The purpose of this study was to determine the effect of Pilates Reformer training on gait improvement of subjects with asymmetric pelvic rotation. The seven subjects with greater pelvic rotation in right swing were assessed twice, 4 weeks apart, during which there was submitted to a Pilates Reformer training (three 40 min session per week). The kinematic data consisted of pelvic rotation and flexion angle of hip and knee joint was measured during gait. In comparison between both leg swings, max, min and range values of pelvic rotation was not significantly difference. After training, range of pelvic rotation in right swing was significantly decreased, but in left swing was not. In comparison between both leg swings, the values of max of hip and knee joint angle was significantly difference. After training, max values of angle of knee joint in right swing was significantly increased, but in left swing was not. The result of this study revealed that Pilates Reformer training was effective in improving gait to symmetric pelvic rotation.

Detection of Quantitatively Spread Movement of Atom on the Oxygen Generator

  • Kim, Jeong-lae;Seo, Ji-yeon;Jeong, Hyun-woo
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.294-298
    • /
    • 2020
  • We was constructed of the spread movement with tremor layer point by the tractile-dot structure that was analyzed the squirm quake forms of the perception movement on the atom liquid. Algorithm of squirm quake forms was used to move the spread tremor on the atom state. To detect the tiny signal, we compared the association average value of the squirm quake form on the atom state. Their subject were issued the valuation standard and perception movement for basic atom condition by the spread tremor. We take to detect the tiny scores of average during perception movement side from the spread tremor that magnetic condition get to a variation of the Ma-αAVG and Ma-αMAX-MIN with 6.25±0.35 units, that electric condition get to a variation for the El-αAVG and El-αMAX-MIN with 5.68±0.42 units. The spread tremor was to investigate the capacity of the tremor form, to uptake a spread data of spread tremor level on the CCPL that was denoted the calm-classification form by the spread perception level system. As the squirm quake forms was demanded by the spread tremor signal, max-average values of perception movement were checked the spread position for association average data. We make mention of squirm quake forms for a signal association and a quake data signal of relation system.

Aerobic Capacity and Ventilatory Response During Incremental Exercise in Elite High School Cyclist (점진부하 운동에서 중고교 엘리트 사이클 선수들의 유산소능력과 폐환기 반응)

  • Lee, Dae-Taek;Bae, Yoon-Jung
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.437-443
    • /
    • 2010
  • This study was designed to examine the aerobic capacity and ventilatory response during an incremental exercise in elite high school cyclists. Twelve boys ($17{\pm}1\;yr$, $175{\pm}5\;cm$, $70{\pm}9\;kg$) participated in anthropometric measurements, incremental exercise testing, and pulmonary function tests. During incremental exercise testing using a cycle ergometer, their maximal oxygen uptake ($VO_2max$), maximal power output, ventilation, ventilatory equivalents for oxygen ($V_E/VO_2$) and carbon dioxide ($V_E/VCO_2$), respiratory rate, and tidal volume were measured. Time variables such as inspiratory time (Ti), expiratory time (Te), breathing time (Tb), and inspiratory duty cycle (Ti/Tb), as well as inspiratory flow rate ($V_T$/Ti) were assessed. Pulmonary function of vital capacity (FVC), forced expiratory volume in one second ($FEV_1$), $FEV_1$/FVC, and peak expiratory flow were evaluated. Their $VO_2max$, maximal heart rate, and Wmax were $57.5{\pm}3.9\;ml{\cdot}kg^{-1}{\cdot}min^{-1}$, $194.1{\pm}8.6\;beat{\cdot}min^{-1}$, and 452 W, respectively. $VO_2max$ was not related to any anthropometric parameters. Most ventilatory variables progressively increased with exercise intensity. As intensity increased, Ti, Tb, Tb decreased while Ti/Tb was maintained. Below an intensity of 250 W, height, weight, body mass index, and body surface were highly correlated with $V_T$/Ti and Ti/Tb (p<0.05). Collectively, $VO_2max$ appeared to be lower than adult cyclists, suggesting a different pattern of ventilatory control as age advances. Morphological characteristics were not related to $VO_2max$ in the population. Time variables of ventilatory response seemed to be related only at an exercise intensity level of less than 250 W. $V_T$/Ti may be related to exercise endurance capacity, but Ti/Tb was similar to adult cyclists.

Fuzzy Hardware Implementation using the Hausdorff Distance (Hausdorff Distance를 이용한 퍼지 하드웨어 구현)

  • 김종만;변오성;문성룡
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.147-150
    • /
    • 2000
  • Hausdorff distance(HD) commonly used measures for object matching, and calculates the distance between two point set of pixels in two-dimentional binary images without establishing correspondence. And it is realized as the image filter applying the fuzzy. In this paper, the fuzzy hardware realizes in order to construct the image filter applying HD, also, propose as the method for the noise removal using it in the image. MIN-MAX circuit designs the circuit using MAX-PLUS, and the fuzzy HD hardware results are obtained to the simulation. And then, the previous computer simulation is confirmed to the result by using MATLAB.

  • PDF

THE DIMENSION OF THE CONVOLUTION OF BIPARTITE ORDERED SETS

  • Bae, Deok-Rak
    • Journal of the Korean Mathematical Society
    • /
    • v.36 no.3
    • /
    • pp.633-648
    • /
    • 1999
  • In this paper, for any two bipartite ordered sets P and Q, we define the convolution P * Q of P and Q. For dim(P)=s and dim(Q)=t, we prove that s+t-(U+V)-2 dim(P*Q) s+t-(U+V)+2, where U+V is the max-mn integer of the certain realizers. In particular, we also prove that dim(P)=n+k- {{{{ { n+k} over {3 } }}}} for 2 k n<2k and dim(Pn ,k)=n for n 2k, where Pn,k=Sn*Sk is the convolution of two standard ordered sets Sn and Sk.

  • PDF