• Title/Summary/Keyword: Max8

Search Result 1,584, Processing Time 0.027 seconds

An Augmented WiMAX MMR Protocol for Establishing Secure Broadband Maritime Data Networks (안전한 광대역 해상정보통신망 구축을 위한 WiMAX MMR 확장 프로토콜)

  • Lee, Su-Hwan;Son, Joo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.8
    • /
    • pp.1145-1152
    • /
    • 2010
  • Currently economical communication technologies are needed for high speed data exchange at sea. Wireless environments at sea require some special communication security solutions as well. In this paper, an augmented WiMAX MMR protocol is proposed as a solution of the broadband data communications and security at sea environments fundamentally with no base station.

Bioequivalence of Alpit Tablet to Algiron Tablet (Cimetropium Bromide 50 mg) (알기론 정(브롬화 시메트로피움 50 mg)에 대한 알피트 정의 생물학적 동등성)

  • Cho, Hea-Young;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.1
    • /
    • pp.47-54
    • /
    • 2002
  • Cimetropium bromide, a quaternary ammonium compound which is chemically related to scopolamine, exhibits its antispasmodic activity by competing with acetylcholine for the muscarinic receptors of the smooth muscle of gastrointestinal tract. The drug has been used for the treatment of various disorders involving spasms of the musculature of the gastrointestinal, biliary and genitourinary tracts. The purpose of the present study was to evaluate the bioequivalence of two cimetropium bromide tablets, $Algiron^{TM}$ (Boehringer Ingelheim Korea Ltd.) and $Alpit^{TM}$ (Hana Pharmaceutical Co., Ltd.), according to the prior and revised guidelines of Korea Food and Drug Administration (KFDA). The cimetropium bromide release from the two cimetropium bromide tablets in vitro was tested using KP VII Apparatus II method with various different kinds of dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty normal male volunteers, $25.25{\pm}2.10$ years in age and $65.76{\pm}6.39$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After three tablets containing 50 mg of cimetropium bromide per tablet were orally administered, blood was taken at predetermined time intervals and the concentrations of cimetropium bromide in serum were determined using HPLC method with UV detector. The dissolution profiles of two cimetropium bromide tablets were very similar at all dissolution media. Besides, the pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using non-transformed and logarithmically transformed $AUC_t\;and\;C_{max}$. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on the $Algiron^{TM}$ were 2.19%, -5.97% and 3.49%, respectively. Minimum detectable differences $({\Delta})\;at \;{\alpha}=0.05\;and\;1-{\beta}=0.8$ were less than 20% (e.g., 13.71 %, 19.05% and 15.11% for $AUC_t,\;C_{max}\;and\;T_{max}$, respectively). The powers $(1-{\beta})\;at\;{\alpha}=0.05,\;{\Delta}=0.2\;for\;AUC_t$, $C_{max}\;and\;T_{max}$ were 97.79%, 83.22% and 95.60%, respectively. The 90% confidence intervals were within ${\pm}20%$ (e.g., $-5.84{\sim}10.21,\;-17.11{\sim}5.18\;and\;-5.35{\sim}12.33\;for\;AUC_t,\;C_{max}\;and\;T_{max}$, respectively). There were no sequence effect between two tablets in logarithmically transformed $AUC_t\;and\;C_{max}$. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) (e.g., $0.94{\sim}1.10\;and\;0.85{\sim}1.05\;for\;AUC_t\;and\;C_{max}$, respectively). Two parameters met the criteria of prior and revised KFDA guideline for bioequivalence, indicating that $Alpit^{TM}$ tablet is bioequivalent to $Algiron^{TM}$ tablet.

A Study of WiMAX Security threats and Their Solution

  • Woo, Seon-mi;Jeong, Gisung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.2
    • /
    • pp.66-74
    • /
    • 2016
  • In this study, we have discussed and illustrated the security issues of WiMAX technology including vulnerabilities, threats and some security solution. Both physical layer and data link layer have been considered. Jamming is a major threat in physical layer, and in data link layer we study an authentication problem and see the problem of some unencrypted messages leading to lack of confidentiality. Some of these vulnerabilities have been solved in the recent amendment of 802.16 and some still remain. Moreover WiMax is a new technology yet.

Bioequivalence Study of Acetyl-L-Carnitine Tablets (아세틸-엘-카르니틴 정제의 생물학적 동등성 평가)

  • 박경미;이미경;신지영;임수정;임윤영;김종국;우종수
    • Biomolecules & Therapeutics
    • /
    • v.9 no.4
    • /
    • pp.285-290
    • /
    • 2001
  • Bioequivalence of two acetyl-1-carnitine tablets, test product (Carnitile tablet: Hanmi Pharm. Co., Ltd.) and reference product (Nicetil $e^{R}$ tablet: Dong-A Pharm. Co., Ltd.), was evaluated according to the guide- lines of Korea Food and Drug Administration (KFDA). Twenty-six healthy volunteers were divided randomly into two groups and administered the drug orally at the dose of 500 mg as acetyl-1-carnitine in a 2$\times$2 crossover study. Blood samples were taken at predetermined time intervals for 12 hours and the plasma concentration of acetyl-1-carnitine was determined using HPLC by derivatization with p-bromophenacyl bromide. The pearmacokinetic parameters (AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$) were calculated and ANOVA was utilized for the statistical analysis of parameters. The apparent differences of these parameters between two drugs were less than 20% (i.e., 1.26,-5.08 and 8.59% for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, respectively). The powers (1-$\beta$) for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, and Tmax were over 0.9. Minimal detectable difference ($\Delta$) at $\alpha$=0.05, 1-$\beta$=0.8 were less than 20% (i.e.,7.31, 14.88 and 11.77% for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, respectively). The confidence intervals ($\delta$) for these parameters were also within $\pm$ 20% (i.e.,-3.03$\leq$$\delta$$\leq$5.54, -13.80$\leq$$\delta$$\leq$3.64 and 1.69$\leq$$\delta$$\leq$15.48 for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, respectively). These results satisfied the criteria of KFDA guideline for bioequivalence, indicating Carnitile bioequivalent to Nicetil $e^{R}$ .TEX>$^{R}$ .> R/ . R/ .

  • PDF

Bioeuqivalence Study of Nabumetone Tablets in Man

  • Lee, Young-Joo;Jang, Eun-Ju;Lee, Jeong-Uk;Han, Yong-Hae;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • v.18 no.5
    • /
    • pp.340-345
    • /
    • 1995
  • A nebumetone tablet in development $(Navuton^R)$ was tested for its bioequivalence to the erference tablet $(Uniton^R)$. Seventeen healthy Korean male subjects participated in this study. Each subject received a 1-g dose of nabumetone (2tables each) in an unbalanced, randomized, two-way crossover investigation. Serum concentrations of 6-methoxy-2-na-phthylacetic acid (6-MNA), a major metabolite of nebumetone, were measured over 120 hr interval by a high-performance liquid chromatography. The maximum serum concentration $(C_{max})$ and time to reach the maximum concentration$(T_{max})$ were read directly, but area under the serum concentration time curve from time 0 to 120 hr (AUC) and mean residence time serum curves showed multiple peaks of 6-MNA in most subjects, and the $C_{max}$ and $T_{max}$ were read from the highest serum peaks. calculated bioavailability parameters for test and reference tablets were 148.6 : 1377.9 $\mug \cdot hr/ml$ for AUC; 25.2:23.1 $\mu/ml$ for $C_{max}$; 11.8:16.4 hr for $T_{max}$, and 42.6 : 43.8 hr for MRT, respectively. The paired t-test revealed no significant differences in all the parameters between the two tablets. Analysis ofl variance (ANOVA) revealed no significant differences between groups and formulations in all the parameters ($C_{max}$ and $T_{max}$, AUC and MRT) indicating the crossover design of the experiment was properly performed. But significant differences (p<0.05) between subject/groups and periods were found for all the parameters indicating substantial intersubject and interperiodic variations for these parameters.

  • PDF

A STUDY ON dmf & PREDILECTION SITES OF PRESCHOOL CHILDREN IN SEOUL. (서울시(市) 미취학아동(未就學兒童)의 dmf 및 치아우식(齒牙齲蝕) 호발부위(好發部位)에 대(對)한 연구(硏究))

  • Ko, Sung-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.8 no.1
    • /
    • pp.103-117
    • /
    • 1981
  • The data about dental caries obtained from 1438 preschool children (male 797, female 641) in Seoul aged from 3 to 6 were analyzed by their sexes, ages, jaws and teeth surfaces. The results were as follows. 1. dmf rate : 92.63% 2. dmft index : 6.06 dmft rate 30.81 % dmfs index : 11.82 dmfs rate 12.02 % 3. d,m & f rate d rate: 79.45% m rate: 8.15% f rate : 12.40 % 4. dft index : 5.94 5. The order of caries susceptible tooth 1. Lower deciduous 2nd molar 2. Lower deciduous 1st molar 3. Upper deciduous 2nd molar 4. Upper deciduous lateral incisor 5. Upper deciduous cental incisor 6. Upper deciduous lateral incisor 7. Lower deciduous canine 8. Upper deciduous canine 9. Lower deciduous central incisor 10. Lower deciduous lateral incisor 6. Predilection sites of each tooth A) Deciduous central incisor ; Max. : Mesial cavity Mand. : Mesio-distal cavity B) Decidous lateral incisor ; Max. : Mesial cavity Mand. : Distal cavity=Mesial cavity C) Deciduous canine; Max. : Labial cavity Mand. : Distal cavity D) Decidous 1st molar ; Max. : Disto-occlusal cavity Mand.: Disto-occlusal cavity E) Deciduous 2nd molar ; Max. : Linguo-occlusal cavity Mand.: Occlusal cavity 7. All the values in caries criteria in 1981 were somewhat lower than in 1968, but m & f rate were increased.

  • PDF

Bioequivalence of Enteric-coated Omeprazole Products (오메프라졸 장용성제제에 대한 생물학적 동등성 평가)

  • Kim, Chong-Kook;Jeong, Eun-Ju;Lee, Eun-Jin;Shin, Hee-Jong;Lee, Won-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 1993
  • The bioequivalence of two omeprazole enteric-coated products was evaluated in 16 normal male volunteers (age 26-32 yr, body weight 57-75 kg) following single oral administration. Test product was enteric-coated KD-182 tablet (Chong Kun Dang Corp., Korea) and reference product was $Rosec^{\circledR}$ capsule containing enteric-coated pellets of omeprazole (Yuhan Corp., Korea). Both products contain 20 mg of omeprazole. One tablet or capsule of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study ($2\;{\times}\;2$ Latin square method). Average drug concetrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products(p>0.05); the area under the concentrationtime curve to last sampling time (8 hr) $(AUC_{0-8hr})$ $(1946.5{\pm}675.3\;vs\;2018.3{\pm}761.6\;ng{\cdot}hr/ml)$, AUC from time zero to infinite $(AUC_{o-\infty})$ $(2288.6{\pm}1212.8\;vs\;2264.9{\pm}1001.3\;ng{\cdot}hr/ml)$, maximum plasma concentration $(C_{max})$ $(772.5{\pm}283.3\;vs\;925.8{\pm}187.7\;ng/ml)$, time to maximum plasma concentration $(T_{max})$ $(2.38{\pm}1.06\;vs\;2.34{\pm}1.09\;hr)$, apparent elimination rate constant $(k_{\ell})$ $(0.5339{\pm}0.2687\;vs\;0.5769 {\pm}0.2184\;hr^{-I})$, apparent absorption rate constant $(k_a)$ $(1.1536{\pm}0.5278\;vs\;0.9739{\pm}0.9507 hr^{-1})$ and mean residence time (MRT) $(3.13{\pm}0.73\;vs \;3.41{\pm}1.04\;hr)$. The differences of mean $(AUC_{0-8hr})$, $C_{max}$, $T_{max}$ and MRT between the two products (3.69, 19.83, 1.32 and 8.99%, respectively) were less than 20%. The power $(1-{\beta})$ and treatment difference $(\triangle)$ for $AUC_{o-8hr}$ $C_{max}$ and MRT were more than 0.8 and less than 0.2, respectively. Although the power for $T_{max}$ was under 0.8, $T_{max}$ of the two products was not significantly different each other(p>0.05). These results suggest that the bioavailability of KD-182 tablet is not significantly different from that of $Rosec^{\circledR}$ capsule. Therefore, two products are bioequivalent based on the current results.

  • PDF

Bioequivalence Test of Rifampicin Preparations(II) (리팜피신 제제의 생물학적 동등성시험(제2보))

  • Chang, Il-Hyo;Burm, Jin-Pil;Choi, Jun-Shik
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.49-55
    • /
    • 1994
  • Bioequivalence test of commercially available rifampicin capsules was performed. Sixteen volunteers were divided into 2 groups and the reference and test drug were given orally (450 mg) by cross-over design. Statistical evaluation of AUC, $C_{max}\;and\;T_{max}$ involved an analysis of variance (ANOVA). The differences of mean value in AUC, $C_{max}\;and\;T_{max}$ between the reference and test drug were within 20% with reference drug. ANOVA showed no significant differences for ‘between group’, ‘drug’ and ‘period’, but not for ‘between subjects’. The power of test $(1-{\beta})\;of\;AUC\;and\;$C_{max}$ was larger than 0.8 and the confidence of bioavailability was $within\;{\pm}20%$. From these results, it was concluded that the two preparations were bioequivalent for AUC and $C_{max}$, but was not for $T_{max}$.

  • PDF

Bioequivalence Assessment of Nabumetone Tablets in Healthy Korean Volunteers

  • Park, Moon-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.15 no.2
    • /
    • pp.118-122
    • /
    • 2007
  • This study was performed to evaluate the bioequivalency between the Osmetone$^{TM}$ Tablet (Myeongmoon Pharm. Co., Ltd.) as a test formulation and the Relafen$^{TM}$ Tablet (Handok Pharm. Co., Ltd.) as a reference formulation. Twenty-four healthy male volunteers were administered the formulations by the randomized Latin square crossover design, and the plasma samples were determined by a high performance liquid chromatography (HPLC) with Ultra-Violet (UV) detector. AUC$_t$, C$_{max}$ and T$_{max}$ were obtained from the time-plasma concentration curves, and log-transformed AUC$_t$ and C$_{max}$ and log-untransformed T$_{max}$ values for two formulations were compared by statistical tests and analysis of variation. AUC$_t$ was determined to be 897.8${\pm}$431.1 ug.hr/ml for the reference formulation and 902.3${\pm}$408.4 ug.hr/ml for the test formulation. The mean values of C$_{max}$ for the reference and test formulations were 24.2${\pm}$8.9 and 24.0${\pm}$9.5 ug/ml, respectively. The AUC$_t$ and C$_{max}$ ratios of the reference Relafen$^{TM}$ Tablet to the test Osmetone$^{TM}$ Tablet were +5.01% and -0.83%, respectively, showing that the mean differences were satisfied the acceptance criteria within 20%. The results from analysis of variance for logtransformed AUC$_t$ and C$_{max}$ indicated that sequence effects between groups were not exerted and 90% confidence limits of the mean differences for AUC$_t$ and C$_{max}$ were located in ranges from log 0.80 to log 1.25, satisfying the acceptance criteria of the KFDA bioequivalence. The Osmetone$^{TM}$ Tablet as the test formulation was considered to be bioequivalant to the Relafen$^{TM}$ Tablet used as its reference formulation, based on AUC$_t$ and C$_{max}$ values.

Bioequivalence of Cisaplus Tablets to Prepulsid Tablets (Cisapride 5 mg) (프레팔시드 정 (시사프리드 5 mg)에 대한 시사프러스 정의 생물학적 동등성)

  • Yoo, Sun Dong;Jun, Hun;Shin, Beom Soo;Park, Joon Woo;Kim, Hak Hyung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.10 no.1
    • /
    • pp.25-29
    • /
    • 2000
  • Bioequivalence of cisapride-containing $Cisaplus^{(R)}$ tablets (Daewoong Co.) to reference $Prepulsid^{(R)}$ tablets (Janssen Co.) was evaluated according to the guidelines of Korea Food and Drug Administration (KFDA). Sixteen healthy volunteers were divided randomly into two groups and administered orally at a cisapride dose of 10 mg in a $2\times2$ crossover design. There was a 1-week washout period between the treatments. Blood samples were taken at predetermined time intervals for 48 hr and the plasma cisapride concentrations were determined by an HPLC with UV detector. The area under the plasma drug concentration-time curve (AUC) was caltulated from time zero to the last sampling time by a linear trapezoidal method. The maximum observed plasma drug concentration ($C_{max}$) and the time to $C_{max}\;(T_{max})$ were estimated directly from the drug concentration-time data. Analysis of variance (ANOVA) showed that the apparent differences for AUC, $C_{max}\;and\;T_{max}$ were $-7.52\%,\;-8.91\%\;and\;-15.55\%$, respectively. The minimum detectable differences for AUC, $C_{max}\;and\;T_{max}$ between formulations were $14.52\%,\;11.57\%\;and\;28.00\%$ respectively, at $\alpha=0.05\;and\;1-\beta=0.8\;levels.\;The\;90\%$ confidence intervals for AUC, $C_{max}\;and\;T_{max}\;were\;-16.00\sim0.97\%,\;-15.67\sim-2.15\%\;and\;-31.88\%\sim0.84\%$, respectively. These results satisfy the bioequivalence criteria of KFDA guidelines, indicating that the two formulations of cisapride are bioequivalent.

  • PDF