• Title/Summary/Keyword: Matrix degradation

Search Result 490, Processing Time 0.025 seconds

The Aging Effect of $Avimid^(R)$ K3B/1M7 Laminates in $80^{\circ}C$ Water ($Avimid^(R)$ K3B/IM7 복합재료의 $80^{\circ}C$ 물에서의 노화현상)

  • Kim Hyung-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.4
    • /
    • pp.23-30
    • /
    • 2005
  • The Hygrothermal aging of the laminates of $Avimid^(R)$ K3B/IM7 in $80^{\circ}C$ water was studied as a function of immersion time prior to forming microcracks. The factors causing the $80^{\circ}C$ water to degradation of the laminates could be the degradation of the matrix toughness, the change in residual stresses or the interfacial damage between the fiber and the matrix. The times to saturation in $80^{\circ}C$ water for the laminates and for the neat resin were 100 hours and 500 hours. After 500 hours aging of the neat resin, the glass transition temperature was changed less than 1% by DSC test, and the weight gain was 1.55% increase with the diffusion coefficient $7\times10^{-6}m/s^2$ and the fracture toughness was decreased about 41%. After 100 hours fully saturated aging of the ${[+45/0/-45/90]}_s$ K3B/IM7 laminates in $80^{\circ}C$ water, the weight gain was 0.41% increase with the diffusion coefficient $1\times10^{-6}m/s^2$. In 100 hours, the loss of the fracture toughness of the laminates was 43.8% of the original toughness by the microcracking fracture toughness criterion. Therefore, the main factor to degrade the microcracking toughness of the laminates could be the degradation of the matrix fracture toughness.

Interference Cancellation for QO-STBC with EVD (EVD기법을 이용한 QO-STBC의 간섭 제거)

  • Kim, Dong Jin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.46-52
    • /
    • 2016
  • Quasi-Orthogonal STBC (QO-STBC) scheme is proposed conventionally achieving approximate full rate and full diversity in more than 3 transmit antenna and open-loop environmen.. But, conventional QO-STBC has disadvantage that performance degradation by interference terms of detection matrix and high decoding complexity. Recently, this interference cancellation scheme of low decoding complexity by multiplying specific rotation matrix is proposed. We propose more general interference cancellation scheme by using EVD(Eigenvalue Decompostion).

Research for Predicting Image Degradation followed by Modification of The Compressed Image's Coefficient (영상의 압축영역 계수 변경에 따른 질저하 예측의 연구)

  • Choi, Yong-Soo;Kim, Hyoung-Joong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.121-124
    • /
    • 2008
  • 최근에는 인터넷 환경에서 여러 형태의 압축된 파일이 이용되고 있으며 통신량의 감소, 통신시간의 절약 등 많은 장점을 가지고 있다. 그래서 많은 압축 기법 그리고 압축 기법에서 동작하는 영상처리기법들이 개발되어 지고 있다. 정보 은닉에서도 JPEG과 같은 압축파일에서 동작하는 알고리즘이 개발되어 지고 있다. 이와 같은 알고리즘들은 주파수변환이나 양자화의 기본적인 룰을 이해하고 있으며 그들의 프로그램에 그러한 룰들을 적용하여 개발에 이용하고 있다. 하지만 정보은닉 알고리즘에 있어, 많은 경우에 데이터 변경 후에 정보은닉의 영향을 평가하였다. 우리는 이 논문에서 정보은닉 처리과정에서 생겨나는 데이터 변경의 영향을 예측하기 위한 방법을 제안하였다. JPEG과 같은 압축 환경에서 정보 은닉 시 적용 가능한 몇 가지 중요한 사실을 여러 경우의 실험을 통하여 얻어냈다. 이러한 사실들은 현재 존재하는(Matrix Encoding, Modified Matrix Encoding 등을 포함한 F3, F4 and F5 알고리즘 등 [1],[5],[6]) 정보은닉 프로그램의 성능향상, 알고리즘 처리시간의 감소와 같은 긍정적인 효과를 거둘 수 있다.

  • PDF

Robust Stability of Uncertain Linear Large-scale Systems with Time-delay via LMI Approach (LMI 기법을 이용한 시간지연 대규모 불확정성 선형 시스템의 강인 안정성)

  • Lee, Hee-Song;Kim, Jin-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1287-1292
    • /
    • 1999
  • In large-scale systems, we frequently encounter the time-delay and the uncertainty, and these should be considered in the design of controller because these are the source of the degradation of the system performance and instability of system. In this paper, we consider the robust stability of the linear large scale systems with the uncertainties and the time-delays. The considered uncertainties are both structured uncertainty and the unstructured uncertainty. Also, the considered time-delays are time-varying having finite time derivative limits. Based on the Lyapunov theorem and the linear matrix inequality(LMI) technique, we present two sufficient conditions that guarantee the robust stability of the system. The conditions are expressed as the LMI forms which can be easily checked their feasibility by using the well-known LMI control toolbox. Finally, we show by two examples that our results are less conservative than the previous results.

  • PDF

RETROVIRUS-MEDIATED DELIVERY OF TIMP-2 SUPPRESSES MMP-2 SECRETION AND INVASION: A GENE THERAPY APPROACH

  • Ahn, Seong-Min;Yeowon Sohn;Kim, Yun-Soo;Aree Moon
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.10a
    • /
    • pp.200-200
    • /
    • 2001
  • The matrix metalloproteases (MMPs) play important roles in metastasis and invasion in various cell types. An endogenous inhibitor of MMP, tissue inhibitor of metalloprotease-2 (TIMP-2), has high specificity for MMP-2. An imbalance between MMP-2 and TIMP-2 causes the degradation of the extracellular matrix associated with pathological events including invasion and metastasis. Since TIMPs are secreted molecules, they have the potential to be used for gene therapy of certain tumors. (omitted)

  • PDF

A study on the bending strength characteristics of steel bar and GFRP rebar in salt water surroundings (해수 환경에서의 철근과 GFRP 리바의 굽힘 강도 특성에 관한 연구)

  • Han, Gil-Young;Lee, Dong-Gi;Kwak, Sang-Muk;Bae, Si-Yon;Kim, Ki-Sung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.354-358
    • /
    • 2002
  • This paper describes the need for a ductile Fiber Reinforced Plastics (FRP) reinforcement for concrete structures. To promte the degradation of the adhesive condition at the fiber/matrix micro interface without matrix dissolution loss were carried out in salt water surrounding. The absorption properties and the bending strength were compared about GFRP rebar and steel bar.

  • PDF

Characterization of Extremely Hydrophobic Immunostimulatory Lipoidal Peptides by Matrix Assisted Laser Desorption Ionization Mass Spectrometry

  • 장정석;이성택;장윤석
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.1036-1039
    • /
    • 1996
  • Synthetic lipoidal peptides based on viral protein sequences have been prepared. These peptides contain an N-palmitoyl group at the N-terminal residue, which is a modified cysteine, containing a S-[2,3-bis(acyloxy)-(2-R,S)-propyl] moiety. When this residue (Pam3Cys) is at the N-terminus of a synthetic peptide, it acts as potent immunoadjuvant to enhance both IgM and IgG antibody responses to the attached peptide. Conventional analytical procedures (e.g., Edman degradation and amino acid analysis) are either not applicable due to the N-terminal modification, or do not provide confirmation of the intact structure. Chromatographic analysis is also hindered by the tendency of these lipoidal Pam3Cys peptides to form large aggregates, and in some cases to be permanently adsorbed on reversed phase columns. We have applied several mass spectrometric techniques, including fast atom bombardment (FAB), electrospray ionization (ESI) and matrix assisted laser desorption ionization (MALDI) to characterize the intact structures of a number of different Pam3Cys synthetic peptides. The MALDI-MS has been found to be the most sensitive for the analysis of the structure of Pam3Cys peptides.

AN EVALUATION OF CHEMICAL DEGRADATION OF LIGHT-CURED RESTORATIVE COMPOSITES (광중합 복합레진의 화학적 분해 평가)

  • Yang, Kuy-Ho;Kim, Hun-Ju;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.530-539
    • /
    • 2003
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Charisma, Filtek P 60, Palpique Estelite, and Spectrum. Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 2 weeks they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth(${\mu}m$) - measured SEM and CLSM from polished circular sections of exposed specimens. The results were as follows: 1. The sequence of mass loss was in descending order by Palpique Estelite, Filtek P 60, Charisma, and Spectrum. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek P 60, Charisma, Palpique Estelita, and Spectrum. 3. The sequence of the Si loss was in descending order by Chrisma, Spectrum, Palpique Estelite, and Filtek P 60. 4. The correlation coefficient between mass loss and degradation layer depth was relatively high(r=0.704, p<0.05). 5. When observed with SEM, destruction of bonding was observed between resin matrix and filler. 6. When observed with CLSM, degradation layer depth of composite resin surface was observed.

  • PDF

SEM AND CONFOCAL LASER SCANNING MICROSCOPIC STUDY ON THE CORROSION OF DENTAL RESTORATIVE RESINS (주사전자현미경과 공촛점 레이저 주사현미경을 이용한 치과용 수복레진의 부식에 관한 연구)

  • Yang, Kuy-Ho;Park, Eun-Hae;Jeong, Byung-Cho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.430-438
    • /
    • 2002
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins-Prodigy(Kerr, USA), Vitalescence(Ultradent, USA), Z 250(3M, USA), Filtek flow(3M, USA)- in an alkaline solution. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%), (b) Si loss(ppm), (c) degradation depth($\mu}m$). The results were as follows: 1. There was no significant difference between Prodigy and Vitalescence, also Z 250 and Filtek flow. But, there was significant difference between former group and latter group. 2. The sequence of the degree of degradation layer depth was in descending order by Z 250, Filtek flow, Prodigy, Vitalescence. There was significant difference among the materials. 3. The sequence of the Si loss was in descending order by Filtek flow, Z 250, Prodigy, Vitalescence. There was significant difference among the materials. 4. The correlation coefficient between mass loss and degradation layer depth(r=0.714, p<0.05), mass loss and Si loss(r=0.770, p<0.05), and degradation layer depth and Si loss(r=0.930, p<0.05) were relatively high. 5. When observed with SEM, destruction of bonding was observed between resin matrix and filler. 6. When observed with CLSM, degradation layer depth of composite resin surface was observed.

  • PDF

Novel Phenol Resin Carbonizing Method for Carbon Interlayer Coating between Reinforcing Fiber and Matrix in Fiber Reinforced Ceramic Composite (페놀수지 탄화 코팅법을 이용한 섬유강화 복합재료 계면 형성에 관한 연구)

  • Kim, Se-Young;Woo, Sang-Kuk;Han, In-Sub
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.3
    • /
    • pp.301-305
    • /
    • 2009
  • The novel carbon coating process for interlayer of fiber reinforced ceramic composites between fiber and matrix was performed by carbonizing phenolic resin solution that coated on fiber surface in $N_2$ atmosphere at $600^{\circ}C$ to improve the strength and fracture toughness of CMC(ceramic matrix composite). 160 nm carbon layer was coated on fiber surface with 5 vol% of phenolic resin solution. Since the process temperature ($600^{\circ}C$) is lower than chemical vapor deposition($900{\sim}1000^{\circ}C$), the strength and toughness could be preserved. Furthermore the coating thickness uniformity was improved to 8% of deviation along the stacking sequence. Therefore, prevention from fiber degradation during coating process and controlling coating thickness uniformity along the preform depth were achieved by coating with phenolic resin carbonizing method.