• 제목/요약/키워드: Matrix degradation

검색결과 490건 처리시간 0.032초

Analysis of a Composite Panel with Transverse Matrix Cracks under Bending and Twisting Moments (굽힘 및 비틀림 하중작용시 횡방향 모재균열을 갖는 복합재료 판넬 해석)

  • Park, Jung-Sun;Hur, Hae-Kyu;Lee, Soo-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제21권6호
    • /
    • pp.971-980
    • /
    • 1997
  • This study is to investigate the stiffness degradation of a composite laminated panel including transverse matrix cracks subjected to bending and twisting moments. Micromechanics theory on the composite material is derived by introducing crack density. Iterative numerical scheme is developed to calculate the degraded composite stiffness which has nonlinear relation due to the crack density. The finite element method is used for structural analysis of the composite panel. Structural responses of the composite panel are examined for various laminated angles and crack density under the bending and twisting moments. Also, the effect of crack opening and closing is considered in the examination. It is realized that the matrix cracks may cause severe stiffness reduction and should be considered in the composite laminated panel.

HYDROLYTIC DEGRADATION OF DENIAL COMPOSITE RESINS (수종 치과용 복합레진의 가수분해)

  • Yang, Kyu-Ho;Kim, Jung-Ran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제27권2호
    • /
    • pp.370-378
    • /
    • 2000
  • The composite restorative resins have their insufficient resistance to wear. The subsurface degradation within the restoration is considered to be associated with wear. The aim of this study was to evaluate the resistance to degradation of six commercial composite resins in an alkaline solution. The brands studied were Clearfil APX(Kuraray), Heliomolar(Vivadent), Surefil(Dentsply), TPH(Dentsply), Tetric Ceram(Vivadent), and Z100(3M). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCL, washed with water and dried to constant mass at $60^{\circ}C$. Resistance to degradation was evaluated on the basis of the following parameters: (a) mass loss(%) - determined from pre-and post-exposure specimen weights; (b) Si loss (ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were as follows: 1. The mass loss was in descending order by Z100, TC H, S, CL, TPH and in the range of $0.45\sim3.64%$ 2. The degradation layer depth was in descending order by H, Z100, S, TC, TPH, CL and in the range of $10.85\sim73.38{\mu}m$ 3. For the Si concentration, Z100 was the highest of all 4. The highly significant correlation(r=0.81, p<0.05) was observed between mass loss and degradation depth. 5. Under scanning electronmicroscopy, the degradation of connection between resin matrix and fillers was observed 2 weeks after soaking in NaOH solution.

  • PDF

Effect of Melt-mixing Conditions on Fracture Properties of Bioabsorbable HA/PLLA Composite Materials (생체흡수성 HA/PLLA 복합재료의 용융혼련조건이 파괴특성에 미치는 영향)

  • Park, Sang-Dae;Lee, Deok-Bo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제31권7호
    • /
    • pp.732-738
    • /
    • 2007
  • Effects of melt-mixing conditions on fracture properties of hydroxyapatite filled bioabsorbable poly(L-lactic acid)(HA/PLLA) composites was investigated by measuring the firacture toughness value of HA/PLLA composites prepared under different mixing time and rotor speed. The fracture surface morphology was also examined by profile measurement and scanning electron microscopies. It was found that the fracture toughness of HA/PLLA composites decreases due to decrease of ductile deformation of PLLA matrix and debonding of interfaces with increase of the rotor speed and mixing time. Effect of mixing process on neat PLLA was also assessed, and it was found that the fracture toughness of PLLA decreases due to disappearance of multiple craze formation and increase of defects. Such thermal and shear-stress degradation were found to be the primary mechanisms of the degradation of HA/PLLA composites during melt-mixing process.

Threshold Voltage Instability in a-Si:H TFTs and the Implications for Flexible Displays and Circuits

  • Allee, D.R.;Venugopal, S.M.;Shringarpure, R.;Kaftanoglu, K.;Uppili, S.G.;Clark, L.T.;Vogt, B.;Bawolek, E.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1297-1300
    • /
    • 2008
  • Electrical stress degradation of low temperature, amorphous silicon thin film transistors is reviewed, and the implications for various types of flexible circuitry including active matrix backplanes, integrated drivers and general purpose digital circuitry are examined. A circuit modeling tool that enables the prediction of complex circuit degradation is presented.

  • PDF

Electrical Analysis of Bottom Gate TFT with Novel Process Architecture

  • Pak, Sang-Hoon;Jeong, Tae-Hoon;Kim, Si-Joon;Kim, Kyung-Ho;Kim, Hyun-Jae
    • Journal of Information Display
    • /
    • 제9권2호
    • /
    • pp.5-8
    • /
    • 2008
  • Bottom gate thin film transistors (TFTs) with microcrystalline and amorphous Si (a-Si) double active layers (DAL) were fabricated. Since the process of DAL TFTs can use that of conventional a-Si TFTs, these DAL TFT process has advantages, such as low cost, large substrate, and mass production capacity. In order to analyze the degradation characteristics in saturation region for driving TFTs of active matrix organic light emitting diode, three different dynamic stresses were applied to DAL TFTs and a-Si TFTs. The threshold voltage shift of DAL TFTs and a-Si TFTs during 10,000 second stress is 0.3V and 2V, respectively. DAL TFTs were more reliable than a-Si TFTs.

Material Properties Degradation of Composite Body Panel Exposed to High Temperature (복합재료 Body Panel의 고온열화 특성)

  • Pyun, Hyun-Joong;Nam, Hyun-Wook;Han, Kyung-Seop
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.219-224
    • /
    • 2000
  • A research for development of composite body panel is in progress for lightening tare. Low specific weight LPMC (Low pressure molding compound) has advantages such as lightweight and resistance to dent and corrosion. In this study, tensile, bending and impact tests for the LPMC and SPRC35 (High tension steel plate) were carried out and compared. Although mechanical properties of SPRC35 are better than the LPMC, the LPMC satisfies basic requirements for car body panel. The high temperature exposed LPMC were degraded due to fiber-matrix debonding and deterioration of resin.

  • PDF

A Study on The Electrical and Mechanical Characteristics due to accelerated degradation of Cycloaliphatic Epoxy Composites (CYCLOALIPHATIC 애폭시 복합재료의 가속열화에 미치는 전기적 및 기계적 특성에 관한 연구)

  • Kim, Hee-Gon;Cho, Han-Goo;Park, Yong-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1323-1326
    • /
    • 1994
  • the application of epoxy composite materials for outdoor insulating systems has some significant advantages compared with conventional inorganic materials, that is low weight in combination with high mechanical strength, small dimensions and design versatility. The experimental results for the basis composition and interlace characteristics of the matrix resin/inorganic fillers($SiO_2$) which are the composite materials have been studied. The electrical characteristics(electrical breakdown, dielectric, insulating resistivity, tracking) and mechanical characteristics( tensile strength, elongation, flexible strength) in the epoxy composite materials have been studied. The life of the epoxy composite material was evaluated by accelerated Weather-Ometer test and the degradation process due to outdoor exposure condition is discussed with respect to the mechanical and electrical properties.

  • PDF

Nondestructive Evaluation for Thermally Degraded Co-base Superalloy by Scanning Acoustic Microscope (초음파현미경을 이용한 Co 기 초내열 합금 열화재의 비파괴평가)

  • Kim, Chung-Seok;Song, Jin-Hun;Kwon, Sook-In;Lim, Jea-Seang;Park, Ik-Keun
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.336-341
    • /
    • 2004
  • This research investigates the feasibility of ultrasonic microscope for nondestructive assessment of thermal degradation in artificially aged commercial Co-base superalloy, FSX414. This alloy has been used for high temperature structure applications such as stationary gas turbine blade and nozzle chamber in fossil plant. Microstructural change was found that the fine carbides became coarser and spheroidized in matrix as aging time increased. The leaky surface acoustic wave velocity gradually decreases by a maximum of 4.7% with increasing aging time up to 4,000hours. However, the longitudinal wave velocity has a little change. Also, it has a good correlation between leaky surface acoustic wave velocity and Vickers hardness. Consequently, LSAW can be used to examine the degree of degradation in thermally aged Co-base superalloy.

  • PDF

Analytic Approach to Fiber Reinforced Composite under Cyclic Loading (반복하중을 받는 섬유 보강 콘크리트의 해석적 접근)

  • Shin, Kyung-Joon;Chang, Sung-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.669-672
    • /
    • 2006
  • Recently, large efforts have been made to develop and understand the behavior of Fiber Reinforced Concrete. As in the static loading cases, many researches have been done. However, a few studies have been conducted in cyclic behaviors of FRC. The main objective of the present work is to investigate the cyclic behavior of fiber reinforced concrete with theoretical method. First, cyclic constitutive relations which describe the crack bridging stress considering non-uniform interfacial bond degradation in short randomly oriented fiber reinforced matrix composites under uniaxial cyclic tension were considered. A cyclic degradation model of single fiber based on micromechanics also taken into consideration. As an example, fatigue analysis for ECC with PVA fiber was conducted using proposed equations. Results shows that proposed method can establish a basis for analyzing cyclic behavior of fiber reinforced composites.

  • PDF

Biodegradable Inorganic-Organic Composite Artificial Bone Substitute

  • Suh, Hwal;Lee, Jong-Eun;Ahn, Sue-Jin;Lee, Choon-Ki
    • Journal of Biomedical Engineering Research
    • /
    • 제16권1호
    • /
    • pp.57-60
    • /
    • 1995
  • To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased.

  • PDF