• Title/Summary/Keyword: Matrix Guide

Search Result 69, Processing Time 0.023 seconds

A Study On The Eigen-properties of A 2-D Square Waveguide by the Krylov-Schur Iteration Method (Krylov-Schur 순환법에 의한 2차원 사각도파관에서의 고유치 문제에 관한 연구)

  • Kim, Yeong Min;Kim, Dongchool;Lim, Jong Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.28-35
    • /
    • 2013
  • The Krylov-Schur algorithm has been applied to reveal the eigen-properties of the wave guide having the square cross section. The eigen-matrix equation has been constructed from FEM with the basis function of the tangential edge-vectors of the triangular element. This equation has been treated firstly with Arnoldi decomposition to obtain a upper Hessenberg matrix. The QR algorithm has been carried out to transform it into Schur form. The several eigen values satisfying the convergent condition have appeared in the diagonal components. The eigen-modes for them have been calculated from the inverse iteration method. The wanted eigen-pairs have been reordered in the leading principle sub-matrix of the Schur matrix. This sub-matrix has been deflated from the eigen-matrix equation for the subsequent search of other eigen-pairs. These processes have been conducted several times repeatedly. As a result, a few primary eigen-pairs of TE and TM modes have been obtained with sufficient reliability.

Manufacturing Process Effect on Strength and Corrosion Properties of Zr Alloys for Fuel Guide Tube (핵연료 안내관용 지르코늄 합금의 강도 및 부식 성능에 미치는 제조공정 영향)

  • Kim, Hyun-Gil;Kim, Il-Hyun;Choi, Byung-Kwan;Park, Sang-Yoon;Park, Jeong-Yong;Jeong, Yong-Hwan
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.852-859
    • /
    • 2009
  • The manufacturing process of zirconium alloys is an import factor to increase their strength and corrosion resistance. In order to find an improved manufacturing process of zirconium alloys in both Zr-1Nb-1Sn-0.1Fe (Alloy-A) and Zr-1.5Nb-0.4Sn-0.2Fe-0.1Cr (HANA-4) for fuel guide tubes, sheet samples were prepared by applying two- and three-step processes that were controlled by an annealing and reduction condition. The mechanical strength and corrosion resistance of both alloys were increased by applying the twostep process rather than the three-step process. From a matrix analysis using TEM, the property improvement is related to the decrease of the precipitate mean diameter with an application of the two-step process. In a comparison of the strength and corrosion properties between Alloy-A and HANA-4, the performance of HANA-4 was feasible for application to fuel guide tubes.

Fiber Reinforced Inlay Adhesion Bridge

  • Cho, Lee-Ra;Yi, Yang-Jin;Song, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.366-374
    • /
    • 2000
  • FRC/ceromer system provides the clinician with a durable, flexible, and esthetic alternative to conventional porcelain fused to metal crowns. FRC is the matrix which is silica-coated and embedded in a resin matrix. The ceromer material which is a second generation indirect composite resin contains silanized, microhybrid inorganic fillers embedded in a light-curing organic matrix. FRC/ceromer restoration has a several advantages: better shock absorption, less wear of occluding teeth, translucency, color stability, bonding ability to dental hard tissues, and resiliency. It has versatility of use including inlay, onlay, single crown, and esthetic veneers. With adhesive technique, it can be used for single tooth replacement in forms of inlay adhesion bridge. In single tooth missing case, conventional PFM bridge has been used for esthetic restoration. However, this restoration has several disadvantages such as high cost, potential framework distortion during fabrication, and difficulty in repairing fractures. Inlay adhesion bridge with FRC/ceromer would be a good alternative treatment plan. This article describes a cases restored with Targis/Vectris inlay adhesion bridge. Tooth preparation guide, fabrication procedure, and cementation procedure of this system will be dealt. The strength/weakness of this restoration will be mentioned, also. If it has been used appropriately in carefully selected case, it can satisfy not only dentist's demand of sparing dental hard tissue but also patient's desire of seeking a esthetic restorations with a natural appearance.

  • PDF

Reliability Assessment Criteria of Organic Light Emitting Diode(OLED) (유기 발광 다이오드의 신뢰성 평가기준)

  • Hong, Won-Sik;Song, Byeong-Suk;Jeong, Hai-Sung;Lim, Jae-Hak
    • Journal of Applied Reliability
    • /
    • v.9 no.2
    • /
    • pp.131-148
    • /
    • 2009
  • An organic light emitting diode (OLED), also light emitting polymer (LEP) and organic electro luminescence (OEL), is any light emitting diode (LED) whose emissive electroluminescent layer is composed of a film of organic compounds. The layer usually contains a polymer substance that allows suitable organic compounds to be deposited. They are deposited in rows and columns onto a flat carrier by a simple "printing" process. The resulting matrix of pixels can emit light of different colors. Such systems can be used in television screens, computer displays, small, portable system screens such as cell phones and PDAs, advertising, information and indication. OLEDs can also be used in light sources for general space illumination, and large-area light-emitting elements. In this paper, we develop the general guide line of the accelerated life test for assuring B10 life of AMOLED(Active Matrix Organic Light Emitting Diode) and PMOLED(Passive Matrix Organic Light Emitting Diode) which are widely used for display monitor less than 115 mm.

  • PDF

Model updating using the feedback exciter : The decision of sensor location & feedback gain (궤환 제어를 이용한 모델 개선법 : 측정 센서 위치와 궤환 이득값 설정)

  • 정훈상;박영진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.802-807
    • /
    • 2002
  • The updating of FE model to match it with the experimental results needs the modal information. There are two cases where this methodology is ill-equip to deal with; under-determined and ill-conditioning problem. The feedback exciter that uses the summation of the white noise and the signals from the measurement sensors multiplied with feedback gains can deal with these problems as the new modal data from the closed loop system generate more constraints the updating parameters should obey. The new modal data from the closed loop system should be different to enhance the condition of the modal sensitivity matrix. In this research, a guide for the selection of the sensor locations and the decision of the corresponding output feedback gains is proposed. This method is based on the sensitivity of the modal data with respect to the feedback gains. Through the proper selection of the exciter and sensor locations and the feedback gain, the eigenvalue sensitivity of the updating parameters which cause the ill-conditioning of the modal sensitivity matrix can be modified and consequently the error contamination in updating parameters are reduced.

  • PDF

TE-TM Mode Conversion in Thin- Film Optical Wave-guides with Gyrotropic and Anisotropic Materials (박막형 광도파관에서 이방성 매질에 의한 TE-TM 모드 변환)

  • 정상구;원영희
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.6
    • /
    • pp.17-32
    • /
    • 1982
  • Wave propagation in gyrotropic or anisotropic medium is analyzed in terms of the eigenmodes of the medium, which are admixture of TE and TM waves. The field composition and the phase velocity of the modes are also determined. The results of the analysis are applied to thin film optical waveguide using such medium as substrate and/or film. Based on the characteristic equations for phase constants of the waveguide, the condition for TE-TM mode convection is derived, and wave propagation in the guide is represented in the form of Jones matrix, which allows a new interpretation in the conversion efficiency of the thin-film optical waveguides.

  • PDF

Evaluation of Physical Properties as Magnesium Stearate Blendedin Hydrophilic Matrix Tablets

  • Choi, Du-Hyung;Jung, Youn-Jung;Wang, Hun-Sik;Yoon, Jeong-Hyun;Jeong, Seong-Hoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • Main objectives of this study were to investigate the effects of a lubricant, magnesium stearate, as blended in a hydrophilic matrix tablet and to identify significant factors using a tablet ejection force and a swelling property. The characteristics of tablet ejection were evaluated with three different compression forces (30, 40, and 60 MPa) and two controlled factors, amount of magnesium stearate and its mixing time. A hydrophilic model drug (terazosin HCl dihydrate) was regarded as a default factor. Tablet swelling was also evaluated. The optimal amount of PEG compared to PEO was set to be 88.50% w/w. As the amount of magnesium stearate was varied from 0.79% to 2.20% w/w, the amount of PEO and PEG was adjusted to meet the tablet's total weight while maintaining the ratio between the two excipients constant. As the mixing time of magnesium stearate was increased, the tablet ejection force and the swelling property were decreased. As the amount of magnesium stearate was increased, the tablet ejection force and the swelling property were decreased since the increased mixing time and the amount of magnesium stearate induced hydrophobic properties of the matrix tablet more effectively. The ejection force of the tablet increased as a result of increase in the compression force, which means that the breaking of tablet/die-wall adhesion energy was also increased when the compression energy was increased. The results gavea valuable guide how to choose suitable amount of the lubricant with processing conditions for the development of hydrophilic matrix formulations.

Effect of Enamel Matrix Derivative on Guided Bone Regeneration with Intramarrow Penetration (골수내천공을 동반한 골유도재생술시 법랑기질유도체의 효과)

  • Lee, Young-Jong;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.393-410
    • /
    • 2004
  • The purpose of this study was to investigate effect of enamel matrix derivative on guided bone regeneration with intramarrow penetration in rabbits. Eight adult male rabbits (mean BW 2Kg) were used in this study. Intramarrow penetration defects were surgically created with round carbide bur(HP long #6) on calvaria of rabbits. Defects were assigned to the control group grafted with mixture of the same quantity of demineralized freeze-dried bone allograft and deproteinized bovine bone mineral. Then, guided bone regeneration was carried out using resorbable membrane and suture. Enamel matrix derivative applied to defects was assigned to the test group. And treated as same manners as the control group. At 1, 2, 3 and 8 weeks after the surgery, animals were sacrificed, specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation. The results of this study were as follows : 1. At 1, 2 and 3 weeks, no differences were observed between the control group and the test group in the aspect of bone formation around bone graft. 2. Proliferation of blood capillary was faster in the test group than in the control group. 3. Bone regeneration in intramarrow penetration was faster in the test group than in the control group. 4. At 8 weeks, new osteoid tissue formation around bone graft was more prominent in the test group than in the control group. From the above results, enamel matrix derivative might be considered as the osteopromotion material and effective in the guided bone regeneration with intramarrow penetration.

Design of Nonreciprocal Twin-toroidal Ferrite Phase Shifter (비가역성 쌍토로이드 페라이트 변위기 설계)

  • 이기오;김영범;박동철;신용수;김윤명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.1
    • /
    • pp.43-52
    • /
    • 1996
  • Nonreciprocal twin-toroid ferrite phase shifter is designed, fabricated, and tested. ABCD matrix method is used to design the phase shifter and to compute its optimum dimen- sions. Quarter-wave two-section impedance matching transformers are utilized in order to match the impedance of the empty guide to that of the ferrite-loaded guide. Driving circuit controls the current needed to drive the phase shifter. Measured insertion loss and VSWR characteristics within the operaring band(9.1GHz ~ 9.5GHz) are less than 1.2dB and 1.15, respectively. After temperature compensation technique is appied to the phase shifter, the measured phase error of the phase shifter is less than $\pm4$ between $-10^{\circ}C\;and\;+60^{\circ}C$.

  • PDF

Development of the Core Task and Competency Matrix for Unit Managers (병원 간호단위관리자의 핵심직무 ­- 핵심역량 매트릭스 개발)

  • Lee, Tae Wha;Kang, Kyeong Hwa;Lee, Seon Heui;Ko, Yu Kyung;Park, Jeong Sook;Lee, Sae Rom;Yu, Soyoung
    • Journal of Korean Clinical Nursing Research
    • /
    • v.23 no.2
    • /
    • pp.189-201
    • /
    • 2017
  • Purpose: The aim of this study was to develop the nursing management core task and competency matrix for hospital unit managers. The perceived level of importance and performance of identified core competencies by unit managers were also investigated. Methods: Literature review and expert survey identified nursing management core task and competencies. Subsequently, the core task and competency matrix was developed and validated by expert panel. A survey of 196 nurse managers from 3 cities identified perceived importance and performance of core competiences. Results: Thirty-eight nursing management core task and thirty-seven nursing management core competencies were identified comprising five categories; Clinical practice knowledge, Evidence-based practice, Employee development, Strategic planning and Initiative. Based on the core task and competencies, the task and competency matrix for unit managers was developed. In the analysis of importance and performance of core competencies, the mean score of importance ($3.50{\pm}0.30$) was higher than the mean score of performance ($3.03{\pm}0.34$). Conclusion: The development of core task and competencies for unit managers in hospitals provides a guide for the development and evaluation of programs designed to increase competence of unit managers.