• Title/Summary/Keyword: Matlab Simulation

Search Result 1,404, Processing Time 0.028 seconds

Modeling and Characteristic Analysis of Grid-connected Wind Turbine Generation System at MATLAB & SIMULINK (MATLAB & SIMULINK 에서 계통연계 풍력발전 시스템의 모델링과 특성해석)

  • An, Hae-Joon;Kim, Hyun-Goo;Jang, Gil-Soo;Ko, Seok-Whan;Jang, Moon-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1168-1169
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation systems and performs simulation according to increase/decrease of real wind speed. Matlab & Simulink implemented modeling of grid-connected wind turbine generation system. Terminal voltage, grid voltage, and active/reactive power shall be observed following the performance of simulation.

  • PDF

Analysis of the Characteristics of the Tidal Current Power Generation System Using Motor-Generator Set (전동기-발전기 실험장치(Motor-Generator Set)를 이용한 조류발전 시스템의 특성 분석)

  • An, Won-Young;Lim, Hyung-Tack;Lee, Seok-Hyun;Kim, Gun-Su;Jo, Chul-Hee
    • New & Renewable Energy
    • /
    • v.9 no.4
    • /
    • pp.19-24
    • /
    • 2013
  • In order to analyze the characteristics of tidal current power generation system, we measured output power in M-G Set (Motor-Generator Set) and MATLAB/Simulink. We installed M-G Set (Motor-Generator Set) and did a simulation using MATLAB/Smulink. The simulation consisted of the tidal current turbine, PMSG, converter, and three-phase PWM inverter. Also, the speed control of the generator was performed using machine side converter. And we measured output voltage, current, power of the generator and the output power of three-phase PWM inverter.

Analysis of GPS Software Receiver (GPS Software 수신기의 분석)

  • Zhang, Wei;Suh, Hee-Jong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.229-236
    • /
    • 2018
  • In this paper, we see the acquisition and tracking of L1 C/A signal on GPS receiver, do the research on GPS signal capture principle's foundation, and do the simulation of the GPS signals capture process for it's realizing and analyzing by Matlab. The simulation result, we can confirm this method's accuracy and the feasibility, and see that a satellite receiving ability play an important role in the efficiency of receiver.

Study on I-V simulation for PV module with matlab (Matlab을 이용한 PV모듈의 I-V시뮬레이션 관한 연구)

  • Hong, Jong-Kyoung;Jung, Tae-Hee;Kang, Gi-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.1-6
    • /
    • 2009
  • This paper estimates numerically cells the electrical characteristics of the PV module with environmental changes such as shunt resistance, series resistance, temperature, irradiance. Series resistance $R_s$ including diode characteristic resistance $r_d$ is derived from the p-n junction diode model. I-V characteristics of this model with series resistance $R_s$ are simulated on Matlab. Finally, theoretical I-V characteristics are compared with those of solar simulator. Those results agreed well within the manufacturer's maximum error range 3%

Channel Equalization for High-speed applications using MATLAB

  • Kim, Young-Min;Park, Tae-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.2
    • /
    • pp.57-66
    • /
    • 2019
  • This paper compared the performance with an overview of channel equalization techniques used in high-speed serial transceivers, including the homogeneous architecture and associated components for the GHz interconnect of backplane and cable channels. It also used the MATLAB tool to present system analysis and simulation results for continuous time equivalent structures. In the case of conventional continuous equalization, high frequency deficits occur due to the use of a comparator that is difficult to implement as well as the low speed limit. In this paper, the channel equalization technique based on the power spectrum analysis of clocks was used to compensate for the frequency loss, and the application of the TX+Channel and TX+Equalizer filters enabled the measurement of attenuation and equivalence without comparators. The application of blender and band-pass filters at high speeds also showed significant effectiveness.

Integrated Simulation Model for Designing Distributed Energy Management System in Microgrid System (마이크로그리드시스템의 분산 에너지관리시스템 설계를 위한 통합시뮬레이션 모델 개발)

  • Cho, Jae-Hoon;Park, Sun-Hong;Lee, Dae-Jong;Cho, Young-Im;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • In this paper, an integrated simulation model for designing multi-agent system based DEMS (distributed energy management system) in stand-alone micro-grid system is proposed. In the design of the EMS(energy management system), the multi-agent based DEMS are more effective than conventional centralized EMS, but it is difficult to design the DEMS by general design tools for power system because of various states of a microgrid system during operation of stand-alone mode. Also, since performance test of the DEMS using a real system is inefficient, an integrated simulation model is required for designing an effective multi-agent system based DEMS. The proposed model consists of Matlab/SimPowerSystems based simulation model of the microgrid system and the Multi-agnet based DEMS designed by Matlab/StateFlow tool. In order to show the effect of the proposed model, the model outputs are analyzed for specified operation conditions.

Power control strategies of a DC-coupled hybrid power system for a building microgrid

  • Cho, Jea-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.50-64
    • /
    • 2011
  • In this paper, a DC-coupled photovoltaic (PV), fuel cell (FC) and ultracapacitor hybrid power system is studied for building microgrid. In this proposed system, the PV system provides electric energy to the electrolyzer to produce hydrogen for future use and transfer to the load side, if possible. Whenever the PV system cannot completely meet load demands, the FC system provides power to meet the remaining load. The main weak point of the FC system is slow dynamics, because the power slope is limited to prevent fuel starvation problems, improve performance and increase lifetime. A power management and control algorithm is proposed for the hybrid power system by taking into account the characteristics of each power source. The main works of this paper are hybridization of alternate energy sources with FC systems using long and short storage strategies to build an autonomous system with pragmatic design, and a dynamic model proposed for a PV/FC/UC bank hybrid power generation system. A simulation model for the hybrid power system has been developed using Matlab/Simulink, SimPowerSystems and Matlab/Stateflow. The system performance under the different scenarios has been verified by carrying out simulation studies using a practical load demand profile, hybrid power management and control, and real weather data.

Simulation of I-V characteristics of a PV module in matlab (Matlab을 통한 PV 모듈의 I-V 출력 특성 시뮬레이션)

  • Hong, Jong-Kuong;Jung, Tae-Hee;Ryu, Se-Hwan;Won, Chang-Sub;Kang, Gi-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.71-72
    • /
    • 2008
  • This paper describes a circuit based simulation model for a Photovoltaic(PV) cell in order to estimate the electrical behavior of the solar cell module with changes of environmental parameters such as shunt resistance, series resistance, temperature and irradiance. An accurate I-V model of PV module is presented based on the Shockley diode model. The general model was implemented on Matlab scrip file, and used irradiance and temperature as variables and outputs of the I-V characteristic. A typical PV module was used for the evaluation, and results was compared with reference taken directly from the manufacturer's published curves leading to excellent agrement with the theoretical prediction.

  • PDF

Simulation for Voltage Variation of a Permanent Magnetic Synchronous Generator Wind Turbine Systems on Simulink (Simulink에서 영구자석 동기형 풍력발전시스템의 전압변동에 대한 시뮬레이션)

  • An, Hae-Joon;Kim, Hyun-Goo;Kim, Hong-Woo;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.184.2-184.2
    • /
    • 2010
  • This study performs modelling and simulation of permanent magnetic synchronous generator wind turbine by using Matlab & Simulink. In simulation, change of wind velocity, change of load, and voltage decrease of infinite bus are performed. Through such simulation, different with wiring system that there is only existing load, this study can confirm problems and voltage changing characteristics, which can occur in distributed electric power that load and electric power is mixed and operated, especially, in interconnecting with wind power generation.

  • PDF

A Study on the Fault Current of Distribution System according to Connection of Wind Turbine Generation Grid-Connected Transformer (풍력발전 계통연계 변압기의 결선에 따른 배전계통의 고장전류에 관한 연구)

  • An, Hae-Joon;Ro, Kyoung-Soo;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.369-371
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF