• Title/Summary/Keyword: Materials data

Search Result 10,878, Processing Time 0.039 seconds

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

$^{99m}Tc$-HMPAO-labelled Leucocyte Scintigraphy in the Diagnosis of Infection after Total Knee Replacement Arthroplasty (인공슬관절 전치환술 환자에서 $^{99m}Tc$-HMPAO-백혈구 스캔을 이용한 인공관절 감염의 진단)

  • Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.413-421
    • /
    • 1999
  • Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  • PDF

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

Monitoring of Sulfur Dioxide, Carotenoid Contents and Bacillus cereus Contamination of Dried Sweet Potato in Circulating Dried Agricultural Products (국내 유통 건조 농산물 중 고구마 말랭이의 이산화황, 카로티노이드 함량 및 바실러스 세레우스오염 정도 조사)

  • Lee, Hyeon Min;Park, Hyun Ji;Kim, Ji Na;Shin, Weon Sun;Kim, Eun Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.6
    • /
    • pp.477-484
    • /
    • 2017
  • This study was conducted to investigate the content of sulfur dioxide, carotenoids and the degree of contamination of Bacillus cereus in 33 kinds of dried sweet potato from domestic mainly dried agricultural products in Korea. According to the characteristics of dried sweet potato samples, it was classified into four clusters and as a result of analyzing the contents of sulfur dioxide, carotenoids and the degree of contamination B. cereus was no significant difference among the clusters. The detection ranges of residual sulfur dioxide from 33 dried sweet potatoes ranged from 0.38 to 28.16 mg/kg, three cases (9.09%) were detected at the reference level of 10 mg/kg or more. But no samples exceeding 30 mg/kg, the tolerance level of sulfur dioxide in dried sweet potatoes were detected. Since dried sweet potato does not have a standard for carotenoids, when comparing the national and international standards of carotenoids, the range of detection of carotenoids in dried sweet potato was $46{\sim}2,663{\mu}g$/100 g, which was within the reference range of $0{\sim}9,826{\mu}g$/100 g. In principle colonies suspected to be B. cereus in dried sweet potato were not detected. In 7 cases (21.21%), there were detected in the range of 0.05~1.59 log CFU/g but not more than 3 log CFU/g as the reference value. The results of this study are expected to be used as basic data to establish quality standard for dried sweet potatoes. In order to control the quality of dried sweet potatoes in domestic market, raw materials, drying method and packaging after distribution, it is necessary to maintain and maintain the process steadily.

Effect of cavity shape, bond quality and volume on dentin bond strength (와동의 형태, 접착층의 성숙도, 및 와동의 부피가 상아질 접착력에 미치는 영향)

  • Lee, Hyo-Jin;Kim, Jong-Soon;Lee, Shin-Jae;Lim, Bum-Soon;Baek, Seung-Ho;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.450-460
    • /
    • 2005
  • The aim of this study was to evaluate the effect of cavity shape, bond quality of bonding agent and volume of resin composite on shrinkage stress developed at the cavity floor. This was done by measuring the shear bond strength with respect to iris materials (cavity shape , adhesive-coated dentin as a high C-factor and Teflon-coated metal as a low C-factor), bonding agents (bond quality: $Scotchbond^{TM}$ Multi-purpose and Xeno III) and iris hole diameters (volume; 1mm or 3mm in $diameter{\times}1.5mm$ in thickness). Ninety-six molars were randomly divided into 8 groups ($2{\times}2{\times}2$ experimental setup). In order to simulate a Class I cavity, shear bond strength was measured on the flat occlusal dentin surface with irises. The iris hole was filled with Z250 restorative resin composite in a bulk-filling manner. The data was analyzed using three-way ANOVA and the Tukey test. Fracture mode analysis was also done When the cavity had high C-factor, good bond quality and large volume, the bond strength decreased significantly The volume of resin composite restricted within the well-bonded cavity walls is also be suggested to be included in the concept of C-factor, as well as the cavity shape and bond quality. Since the bond quality and volume can exaggerate the effect of cavity shape on the shrinkage stress developed at the resin-dentin bond, resin composites must be filled in a method, which minimizes the volume that can increase the C-factor.

Antioxidant Activities and Xanthine Oxidase Inhibitory Effects of Hot-water Extracts from Fruits of Elaeagnus multiflora Thunb. in Maturity (성숙에 따른 뜰보리수(Elaeagnus multiflora Thunb.) 열수추출물의 항산화 활성과 Xanthine Oxidase 저해효과)

  • Yoon, Kyung-Young;Hong, Ju-Yeon;Nam, Hak-Sik;Moon, Yong-Sun;Shin, Seung-Ryeul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.1
    • /
    • pp.14-19
    • /
    • 2007
  • This study was conducted to analyze the antioxidant activity and xanthine oxidase inhibitory effect of hot-water extracts from Elaeagnus multiflora Thunb. to provide fundamental data for the development of functional materials. The antioxidative activities of hot-water extracts from E. multiflora Thunb. were analyzed by electron donating ability (EDA) using 1,1-diphenyl-2-picryl hydrazyl (DPPH), superoxide dismutase (SOD) -like activity by pyrogallol and nitrite scavenging ability. EDA of extracts from unripe, ripe, and overripe fruits were 77.7%, 36.0%, and 23.7% at 100 ${\mu}g/mL$, respectively, and EDA of extract in unripe fruits was higher than those of others. At 1,000 $\mu$g/mL, the SOD-like activities were 32.8%, 11.2% and 5.0% for unripe, ripe, and overripe fruits, respectively. The SOD-like activity was increased along with the increase of unripe and ripe extract concentrations. The nitrite scavenging ability of unripe fruit extracts in 100, 300, 500 ${\mu}g/mL$ of extraction solution in pH 1.2 and 3.0 was higher than those of others. The nitrate scavenging ability of all extracts was decreased according to the increase of pH. Xanthine oxidase inhibitory activities of unripe, ripe and overripe fruits were 30.0%, 28.2%, and 18.2% at 1,000 ${\mu}g/mL$, respectively.

Analytical Validation of Rosmarinic Acid in Water Extract of Perilla frutescens Britton var. acuta Kudo as Functional Health Ingredient (건강기능식품 기능성 원료로써 장흥 차조기 열수 추출물의 지표성분인 로즈마린산 분석법 검증)

  • Park, Sung-Yong;Kim, Jung-Eun;Choi, Chul-Yung;Lee, Dong-Wook;Kim, Ki-Man;Yoon, Goo;Yoon, In-Su;Moon, Hong-Seop;Cho, Seung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.85-88
    • /
    • 2015
  • This study attempted to establish an HPLC analysis method for determination of marker compounds as a part of material standardization for the development of health functional food materials from Perilla frutescens Britton var. acuta Kudo. The quantitative determination method of rosmarinic acid as a marker compound of P. frutescens Britton var. acuta Kudo extract (PFE) was optimized by HPLC analysis using a C18 column ($4.6{\times}150mm$, $5{\mu}m$) with 0.1% acetic acid as the elution gradient and methanol as the mobile phase at a flow rate of 1 mL/min and detection wavelength of 280 nm. The HPLC/UV method was applied successfully to quantification of the marker compound in PFE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9995, and the limit of detection and limit of quantitation were $0.36{\mu}g/mL$ and $1.2{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 3.21% and 1.43%, respectively. Recovery rate test at rosmarinic acid concentrations of 12.5, 25 and $50{\mu}g/mL$ scored between 97.04~98.98% with RSD values from 0.25~1.97%. These results indicate that the established HPLC method is very useful for the determination of marker compound in PFE to develop a health functional material.

Focus Group Interview for the Development of an In-service Educational Program on the Practical Problem Focused Home Economics Curriculum (포커스 그룹 인터뷰를 통한 실천적 문제 중심 가정과 교육과정 연수 프로그램에 대한 요구 분석)

  • Lee, Soo-Hee;Yoo, Tae-Myung
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.3
    • /
    • pp.107-129
    • /
    • 2008
  • The purpose of this study was to get insights and data from home economics teachers for the development of an in-service educational program on practical problem focused home economics program, which was planned to be held from January 21st and to 29th, 2008. For this, focus group interview, one of qualitative research methods, was used. One session of pilot and three sessions of main focus group interview in which total of 18 from October 31st, 2007 to November 14, 2007. Home economics teachers that participated were carried out. Participants requested the followings contents of an in-service educational program regarding the practical problem focused home economics curriculum. First, most of participants strongly desired to participate in an in-service educational program when a program provided. The participants wanted to be a professional, who is able to explain logically with philosophical background and knowledge about the practical problem focused home economics curriculum. Second, participants requested the followings regarding practical problem focused home economics curriculum for the contents of an in-service educational program: philosophy of home economics, setting a perspective on each content areas, development of practical problem, watching a sample class unit, developing teaching materials and motivation stimulating questions, designing of instruction and lesson plans, class presentation and peer evaluation, constructing paper and pencil test items, and feedback from expects on the practical problem focused home economics curriculum. Third, participants wanted an in-service educational program to be a combination of theory and practice, and at least 50% of it allotted to practice. Participants thought that both peer participants and experts from university would evaluate them whether they achieved the objectives of the in-service educational program if an in-service program has to evaluate participants. Participants would evaluate an in-service educational program excellent when they become empowered to teach other home economics teachers the theoretical aspects of the practical problem focused home economics curriculum and the practical aspects as well. Based on the results of this study a framework of the 30 hours practical problem focused home economics curriculum was proposed.

  • PDF