• Title/Summary/Keyword: Materials and methods

Search Result 21,676, Processing Time 0.06 seconds

The Early Experience with a Totally Laparoscopic Distal Gastrectomy (전(全)복강경하 원위부 위절제술의 초기 경험)

  • Kim Jin Jo;Song Gyo Young;Chin Hyung Min;Kim Wook;Jeon Hae Myoung;Park Cho Hyun;Park Seung Man;Lim Keun Woo;Park Woo Bae;Kim Seung Nam
    • Journal of Gastric Cancer
    • /
    • v.5 no.1
    • /
    • pp.16-22
    • /
    • 2005
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been increasing lately. Although minimally invasive surgery is more beneficial, no reported case of a totally laparoscopic distal gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experiences, to determine the feasibility of a totally laparoscopic distal gastrectomy using an intracorporeal gastroduodenostomy in treating early gastric carcinoma. Materials and Methods: We investigated surgical results and clinicopatholgic characteristics of eight(8) patients with an early gastric carcinoma who underwent a totally laparoscopic distal gastrectomy at the Department of Surgery, Our Lady of Mercy Hospital, The Catholic University of Korea, between June 2004 and September 2004. The intracorporeal gastroduodenostomy was performed with a delta-shaped ananstomosis by using only laparoscopic linear staplers (Endocutter 45mm; Ethicon Endosurgery, OH, USA). Results: The operative time was $369.4\pm62.5$ minutes (range $275\∼465$ minutes), and the anastomotic time was 45.1\pm14.4$ minutes (range $32\∼70$ minutes). The anastomotic time was shortened as surgical experience was gained. The number of laparoscopic linear staplers for an operation was $7.1\pm0.6$. The number of lymph nodes harvested was $31.9\pm13.1$. There was 1 case of transfusion and no case of conversion to an open procedure. The time to the first flatus was 2.8$\pm$0.5 days, and the time to the first food intake was $4.1\pm0.8$ days. There were no early postoperative complications, and the postoperative hospital stay was $10.0\pm3.9$ days. Conclusion: A totally laparoscopic distal gastrectomy using an intracorporeal gastroduodenostomy with a delta-shaped anastomosis is technically feasible and can maximize the benefit of laparoscopic surgery for early gastric cancer.

  • PDF

A Study for Improvement of Erythropoietin Responsiveness in Hemodialysis Patients (혈액 투석 환자에서 조혈 호르몬 치료 효과 향상에 대한 연구)

  • Park, Jong-Won;Do, Jun-Yeung;Yoon, Kyung-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.226-238
    • /
    • 2001
  • Background: Anemia in chronic renal failure plays an important role in increasing morbidity of dialysis patients. The causes of the anemia are multifactorial. With using of erythropoietin(EPO) most of uremia-induced anemia can be overcome. However, about 10% of renal failure patients shows EPO-resistant anemia. Hyporesponsiveness to EPO has been related to many factors: iron deficiency, aluminum intoxication, inflammations, malignancies and secondary hyperparathyroidism. So I evaluated the improvement of EPO responsiveness after correction of above several factors. Materials and Methods: Seventy-two patients on hemodialysis over 6 months were treated with intravenous ascorbic acid(IVAA, 300 mg t.i.w. for 12 weeks), After administration of IVAA for 12 weeks, patients were classified into several groups according to iron status, serum aluminum levels and i-PTH levels. Indivisualized treatments were performed: increased iron supplement for absolute iron deficiency, active vitamin D3 for secondary hyperparathyroidism and desferrioxamine(DFO, 5 mg/kg t.i.w.) for aluminum intoxication or hyperferritinemia. Results: 1) Result of IVAA therapy for 12 weeks on all patients(n=72). Hemoglobin levels at 2, 4, 6 week were significantly elevated compared to baseline, but those of hemoglobin at 8, 10, 12 week were not significantly different. 2) Result of IVAA therapy for 20 weeks on patients with 100 ${\mu}g/l$ ${\leq}$ ferritin < 500 ${\mu}g/l$ and transferrin saturation(Tsat) below 30%(n=30). After treatment of IV AA for 12 weeks, patients were evaluated the response of therapy according to iron status. Patients with 100 ${\mu}g/l$ ${\leq}$ ferritin < 500 ${\mu}g/l$ and Tsat below 30% showed the most effective response. These patients were treated further for 8 weeks. Hemoglobin levels at 2, 4 week were significantly increased compared to baseline with significantly reduced doses of EPO at 2, 4, 6, 10, 12, 16, 20 week. Concomitantly significantly improvement of Tsat at 2, 6, 16, 20 week compared to baseline were identified. 3) Result of IVAA therapy for 12 weeks followed by DFO therapy for 8 weeks on patients with serum aluminum above 4 ${\mu}g/l$(n=12) Hemoglobin levels were not significantly increased during IVAA therapy for 12 weeks but dosages of EPO were significantly decreased at 2, 4, 6, 8 week during DFO therapy compared to pre-treatment status. Conclusion: IVAA can be helpful for the treatment of the anemia caused by functional iron deficiency and can reduce the dosage of EPO for anemia correction. And administration of low dose DFO, in cases of increased serum aluminum level, can reduce the requirement of EPO.

  • PDF

The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy (전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구)

  • Park, Zi On;Gwak, Geun Tak;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Kim, Jung Soo;Kwon, Hyoung Cheol;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Purpose: The purpose is to clarify the effect of additional scattering ratio on the edge of the block according to the increasing block thickness with low melting point lead alloy and pure lead in electron beam therapy. Methods and materials: $10{\times}10cm^2$ Shielding blocks made of low melting point lead alloy and pure lead were fabricated to shield mold frame half of applicator. Block thickness was 3, 5, 10, 15, 20 (mm) for each material. The common irradiation conditions were set at 6 MeV energy, 300 MU / Min dose rate, gantry angle of $0^{\circ}$, and dose of 100 MU. The relative scattering ratio with increasing block thickness was measured with a parallel plate type ion chamber(Exradin P11) and phantom(RW3) by varying the position of the shielding block(cone and on the phantom), the position of the measuring point(surface ans depth of $D_{max}$), and the block material(lead alloy and pure lead). Results : When (depth of measurement / block position / block material) was (surface / applicator / pure lead), the relative value(scattering ratio) was 15.33 nC(+0.33 %), 15.28 nC(0 %), 15.08 nC(-1.31 %), 15.05 nC(-1.51 %), 15.07 nC(-1.37 %) as the block thickness increased in order of 3, 5, 10, 15, 20 (mm) respectively. When it was (surface / applicator / alloy lead), the relative value(scattering ratio) was 15.19 nC(-0.59 %), 15.25 nC(-0.20 %), 15.15 nC(-0.85 %), 14.96 nC(-2.09 %), 15.15 nC(-0.85 %) respectively. When it was (surface / phantom / pure lead), the relative value(scattering ratio) was 15.62 nC(+2.23 %), 15.59 nC(+2.03 %), 15.53 nC(+1.67 %), 15.48 nC(+1.31 %), 15.34 nC(+0.39 %) respectively. When it was (surface / phantom / alloy lead), the relative value(scattering ratio) was 15.56 nC(+1.83 %), 15.55 nC(+1.77 %), 15.51 nC(+1.51 %), 15.42 nC(+0.92 %), 15.39 nC(+0.72 %) respectively. When it was (depth of $D_{max}$ / applicator / pure lead), the relative value(scattering ratio) was 16.70 nC(-10.87 %), 16.84 nC(-10.12 %), 16.72 nC(-10.78 %), 16.88 nC(-9.93 %), 16.90 nC(-9.82 %) respectively. When it was (depth of $D_{max}$ / applicator / alloy lead), the relative value(scattering ratio) was 16.83 nC(-10.19 %), 17.12 nC(-8.64 %), 16.89 nC(-9.87 %), 16.77 nC(-10.51 %), 16.52 nC(-11.85 %) respectively. When it was (depth of $D_{max}$ / phantom / pure lead), the relative value(scattering ratio) was 17.41 nC(-7.10 %), 17.45 nC(-6.88 %), 17.34 nC(-7.47 %), 17.42 nC(-7.04 %), 17.25 nC(-7.95 %) respectively. When it was (depth of $D_{max}$ / phantom / alloy lead), the relative value(scattering ratio) was 17.45 nC(-6.88 %), 17.44 nC(-6.94 %), 17.47 nC(-6.78 %), 17.43 nC(-6.99 %), 17.35 nC(-7.42 %) respectively. Conclusions: When performing electron therapy using a shielding block, the block position should be inserted applicator rather than the patient's body surface. The block thickness should be made to the minimum appropriate shielding thickness of each corresponding using energy. Also it is useful that the treatment should be performed considering the influence of scattering dose varying with distance from the edge of block.

The Efficacy of the Change in Belly Board Aperture Location by the Addition of Bladder Compression Device for Radiotherapy of Rectal Cancer (직장암 환자의 골반 방사선치료에서 벨리보드 하위 경계 위치 변화의 영향)

  • Yoon, Hong-In;Chung, Yoon-Sun;Kim, Joo-Ho;Park, Hyo-Kuk;Lee, Sang-Kyu;Kim, Young-Suk;Choi, Yun-Seon;Kim, Mi-Sun;Lee, Ha-Yoon;Chang, Jee-Suk;Cha, Hye-Jung;Seong, Jin-Sil;Keum, Ki-Chang;Koom, Woong-Sub
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.231-237
    • /
    • 2010
  • Purpose: We investigated the effect of location changes in the inferior border of the belly board (BB) aperture by adding a bladder compression device (BCD). Materials and Methods: We respectively reviewed data from 10 rectal cancer patients with a median age 64 years (range, 45~75) and who underwent computed tomography (CT) simulation with the use of BB to receive pelvic radiotherapy between May and September 2010. A CT simulation was again performed with the addition of BCD since small bowel (SB) within the irradiated volume limited boost irradiation of 5.4 Gy using the cone down technique after 45 Gy. The addition of BCD made the inferior border of BB move from symphysis pubis to the lumbosacral junction (LSJ). Results: Following the addition of BCD, the irradiated volumes of SB and the abdominopelvic cavity (APC) significantly decreased ($174.3{\pm}89.5mL$ vs. $373.3{\pm}145.0mL$, p=0.001, $1282.6{\pm}218.7mL$ vs. $1,571.9{\pm}158mL$, p<0.001, respectively). Bladder volume within the treated volume increased with BCD ($222.9{\pm}117.9mL$ vs. $153.7{\pm}95.5mL$, p<0.001). The ratio of irradiated bladder volume to APC volume with BCD ($33.5{\pm}14.7%$) increased considerably compared to patients without a BCD ($27.5{\pm}13.1%$) (p<0.001), and the ratio of irradiated SB to APC volume decreased significantly with BCD ($13.9{\pm}7.6%$ vs. $24.2{\pm}10.2%$, p<0.001). The ratios of the irradiated SB volume and irradiated bladder volume to APC volume negatively correlated (p=0.001). Conclusion: This study demonstrated that the addition of BCD, which made the inferior border of BB move up to the LSJ, increased the ratio of the bladder to APC volume and as a result, decreased the irradiated volume of SB.

The Impact of Bladder Volume on Acute Urinary Toxicity during Radiation Therapy for Prostate Cancer (전립선암의 방사선치료시 방광 부피가 비뇨기계 부작용에 미치는 영향)

  • Lee, Ji-Hae;Suh, Hyun-Suk;Lee, Kyung-Ja;Lee, Re-Na;Kim, Myung-Soo
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.237-246
    • /
    • 2008
  • Purpose: Three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) were found to reduce the incidence of acute and late rectal toxicity compared with conventional radiation therapy (RT), although acute and late urinary toxicities were not reduced significantly. Acute urinary toxicity, even at a low-grade, not only has an impact on a patient's quality of life, but also can be used as a predictor for chronic urinary toxicity. With bladder filling, part of the bladder moves away from the radiation field, resulting in a small irradiated bladder volume; hence, urinary toxicity can be decreased. The purpose of this study is to evaluate the impact of bladder volume on acute urinary toxicity during RT in patients with prostate cancer. Materials and Methods: Forty two patients diagnosed with prostate cancer were treated by 3DCRT and of these, 21 patients made up a control group treated without any instruction to control the bladder volume. The remaining 21 patients in the experimental group were treated with a full bladder after drinking 450 mL of water an hour before treatment. We measured the bladder volume by CT and ultrasound at simulation to validate the accuracy of ultrasound. During the treatment period, we measured bladder volume weekly by ultrasound, for the experimental group, to evaluate the variation of the bladder volume. Results: A significant correlation between the bladder volume measured by CT and ultrasound was observed. The bladder volume in the experimental group varied with each patient despite drinking the same amount of water. Although weekly variations of the bladder volume were very high, larger initial CT volumes were associated with larger mean weekly bladder volumes. The mean bladder volume was $299{\pm}155\;mL$ in the experimental group, as opposed to $187{\pm}155\;mL$ in the control group. Patients in experimental group experienced less acute urinary toxicities than in control group, but the difference was not statistically significant. A trend of reduced toxicity was observed with the increase of CT bladder volume. In patients with bladder volumes greater than 150 mL at simulation, toxicity rates of all grades were significantly lower than in patients with bladder volume less than 150 mL. Also, patients with a mean bladder volume larger than 100 mL during treatment showed a slightly reduced Grade 1 urinary toxicity rate compared to patients with a mean bladder volume smaller than 100 mL. Conclusion: Despite the large variability in bladder volume during the treatment period, treating patients with a full bladder reduced acute urinary toxicities in patients with prostate cancer. We recommend that patients with prostate cancer undergo treatment with a full bladder.

Dose Response Relationship in Local Radiotherapy for Hepatocellular Carcinoma (원발성 간암의 국소 방사선치료 시 선량반응 관계)

  • Park Hee Chul;Seong Jinsil;Han Kwang Hyub;Chon Chae Yoon;Moon Young Myoung;Song Jae Seok;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.118-126
    • /
    • 2001
  • Purpose : In this study, it was investigated whether dose response relation existed or not in local radiotherapy for primary hepatocellular carcinoma. Materials and Methods : From January 1992 to March 2000, 158 patients were included in present study. Exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child's class C, tumors occupying more than two thirds of the entire liver, and performance status on the ECOG scale of more than 3. Radiotherapy was given to the field including tumor with generous margin using 6, 10-MV X-ray. Mean tumor dose was $48.2{\pm}7.9\;Gy$ in daily 1.8 Gy fractions. Tumor response was based on diagnostic radiologic examinations such as CT scan, MR imaging, hepatic artery angiography at $4\~8$ weeks following completion of treatment. Statistical analysis was done to investigate the existence of dose response relationship of local radiotherapy when it was applied to the treatment of primary hepatocellular carcinoma. Results : An objective response was observed in 106 of 158 patients, giving a response rate of $67.1\%$. Statistical analysis revealed that total dose was the most significant factor in relation to tumor response when local radiotherapy was applied to the treatment of primary hepatocellular carcinoma. Only $29.2\%$ showed objective response in patients treated with dose less than 40 Gy, while $68.6\%\;and\;77.1\%$ showed major response in patients with $40\~50\;Gy$ and more than 50 Gy, respectively. Child-Pugh classification was significant factor in the development of ascites, overt radiation induced liver disease and gastroenteritis. Radiation dose was an important factor for development of radiation induced gastroduodenal ulcer. Conclusion : Present study showed the existence of dose response relationship in local radiotherapy for primary hepatocellular carcinoma. Only radiotherapy dose was a significant factor to predict the objective response. Further study is required to predict the maximal tolerance dose in consideration of liver function and non-irradiated liver volume.

  • PDF

Antibiotic Resistance for Common Hospital Acquired-pneumonia Pathogens in the Intensive Care Unit of Newly Opened Hospital (새로 개원한 병원 중환자실에서 주요 원내획득 폐렴 감염균의 연도별 항생제 내성율 변화)

  • Lee, Jae-Hyung;Shin, Sung-Joon;Kim, Young-Chan;Oh, Seung-Il;Kim, Mi-Ok;Park, Eun-Joo;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.3
    • /
    • pp.207-218
    • /
    • 2002
  • Background : Intensive care units (ICUs) are generally considered epicenters of antibiotic resistance and the principal sources of multi-resistant bacteria outbreaks. The antibiotic resistance in newly opened intensive care unit that has no microbial colonization on and around the devices was investigated. Materials and Methods : The authors analyzed the antibiotic resistance patterns for common hospital acquired-pneumonia pathogens in the ICUs(Staphylococcus aureus, Pseudomonas aeruginosa, Acinetobacter spp.) at the newly opened ICU of Hanyang University Medical Center, Kuri Hospital during 6 years(1995-2000). Results : 1) Regarding Staphylococcus aureus, the resistance rate to methicillin was 15% at 1995, 21% at 1996, 20% at 1997, 23% at 1998, 22% at 1999, 55% at 2000. 2) Regarding Pseudomonas aeruginosa, the resistance rate to $3^{rd}$ cephalosporin was 50% at 1995, 50% at 1996, 78% at 1997, 40% at 1998, 77% at 1999, 39% at 2000. Imipenam was 0% at 1995, 27% at 1996, 65% at 1997, 12% at 1998, 16% at 1999, 12% at 2000. Ciprofloxacin was 0% at 1996, 56% at 1997, 36% at 1998, 57% at 1999, 58% at 2000. Tobramycin was 7% at 1995, 10% at 1996, 67% at 1997, 36% at 1998, 65% at 1999, 12% at 2000. Gentamycin was 14% at 1995, 36% at 1996, 67% at 1997, 36% at 1998, 65% at 1999, 12% at 2000. Amikacin was 14% at 1995, 30% at 1996, 61% at 1997, 16% at 1998, 39% at 1999, 18% at 2000. 3) Regarding Acinetobacter spp., the resistance rate to $3^{rd}$ cephalosporin was 92% at 1996, 89% at 1997, 88% at 1998,84% at 1999, 77% at 2000. Imipenem was 50% at 1996, 48% at 1997, 45% at 1998, 49% at 1999, 50% at 2000. Ciprofloxacin was 0% at 1996, 48% at 1997, 33% at 1998, 27% at 1999, 71% at 2000. Tobramycin was 67% at 1995, 100% at 1996, 89% at 1997, 95% at 1998, 87% at 1999, 77% at 2000. Gentamycin was 67% at 1995, 100% at 1996, 89% at 1997, 95% at 1998, 87% at 1999, 83% at 2000. Amikacin was 33% at 1995, 83% at 1996, 82% at 1997, 88% at 1998, 75% at 1999, 69% at 2000. Conclusion : The S.aureus resistance to methicillin, the Pseudomonas aeruginosa resistance to ciprofloxacin, and the Acinetobacter spp. resistance to ciprofloxacin have rapidly increased during 6 years. There is a need to pay speicial attention when using the the antibiotics for the above pathogens. This data may be useful in antibiotic therapy in newly opened intensive care units.

Clinicopathologic Characteristics of and Surgical Strategy for Patients with Submucosal Gastric Carcinomas (위 점막하층암의 임상병리학적 특징과 수술 방법)

  • Park Chan Yong;Seo Kyoung Won;Joo Jai Kyun;Park Young Kyu;Ryu, Seong Yeob;Kim Hyeong Rok;Kim Dong Yi;Kim Young Jin
    • Journal of Gastric Cancer
    • /
    • v.5 no.2
    • /
    • pp.89-94
    • /
    • 2005
  • Purpose: Early gastric cancer (EGC) has an excellent prognosis compared to advanced gastric cancer. The 5-year survival rate for EGC now exceeds $90\%$, and EGC is recognized as a curable malignancy. The important prognostic factor in EGC is the status of lymph-node metastasis. Despite conserving surgery being suggested for EGC at present, it is of vital importance to select a surgical method appropriate to each individual case. This retrospective study was undertaken to clarify clinicopathologic features and factors related to lymph-node metastasis in submucosal gastric cancer in order to determine an appropriate therapy. Materials and Methods: This study analyzed the clinicopathologic features for 279 patients with a submucosal gastric carcinoma (Group I) and compared with those of patients with mucosal (Group II) or muscularis proprial gastric carcinoma (Group III). All patients were operated on from 1981 to 1999 at Chonnam University Hospital. There were no statistically significant differences among the groups with respect to age, gender, tumor location, hepatic metastasis, or peritoneal dissemination. Results: Positive lymph node metastasis was found in 47 ($16.8\%$) of the 279 patients with a submucosal gastric carcinoma. The incidence of lymph-node metastasis was significantly higher in patients with a submucosal gastric carcinoma than in patients with a mucosal gastric carcinoma ($16.8\%\;vs.\;3.9\%\;$; P<0.01). Therefore, depth of invasion was a significant factor affecting in lymph-node metastasis. The 5-year survival rates were $88.6\%$ for patients in Group I, $95.2\%$ for patients in Group II, and $72.7\%$ for patients in Group III (P<0.01 for Group I vs. Group II; Group I vs. Group III). In patients with a submucosal gastric carcinoma, the survival rate with positive lymph nodes was significantly poorer than that of patients without lymph-node metastasis ($87.3\%\;vs.\;94.2\%$; P<0.01). Conclusion: Gastrectomy with D2 lymph node dissection is an appropriate operative procedure for patients with a submucosal gastric carcinoma.

  • PDF

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available (면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyeong;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jeong-Soo;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ha, Sung-Woo;Sohn, Jin-Ho;Lee, In-Kyu;Lee, Jae-Tae;Kim, Bo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 2005
  • Purpose: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. Materials and Methods: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. Results: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by h kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. Conclusion: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.