• Title/Summary/Keyword: Materials and methods

Search Result 21,676, Processing Time 0.063 seconds

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF

Radiation Therapy Alone for Early Stage Non-small Cell Carcinoma of the Lung (초기 비소세포폐암의 방사선 단독치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.323-327
    • /
    • 2002
  • Purpose : To evaluate the outcome of early stage non-small cell lung cancer patients who were treated with radiation therapy alone and define the optimal radiotherapeutic regimen for these patients. Materials and Methods : A retrospective review was peformed on patients with sage I or II non-small cell carcinoma of the lung that were treated at our institution between June, 1987 and May, 2000. A total of 21 patients treated definitively with radiation therapy alone were included in this study. The age of the patients ranged from 53 to 81 years with a median of 66 years. All the patients were male. The medical reasons for inoperability were lack of pulmonary reserve, cardiovascular disease, poor performance status, old age, and patient refusal in the decreasing order. Pathological evidence was not adequate to characterize the non-small cell subtype in two patients. Of the remaining 19 patients, 16 had squamous cell carcinoma and 3 had adenocarcinoma. Treatment was given with conventional fractionation, once a day, five times a week. The doses to the primary site ranged from 56 Gy to 59 Gy. No patients were lost to follow-up. Results : The overall survival rates for the entire group at 2, 3 and 5 years were 41, 30 and $21\%$, respectively. The cause specific survivals at 2, 3 and 5 years were 55, 36 and $25\%$, respectively. An intercurrent disease was the cause of death in two patients. The cumulative local failure rate at 5 years was $43\%$. Nine of the 21 patients had treatment failures after the curative radiotherapy was attempted. Local recurrences as the first site of failure were documented in 7 patients. Therefore, local failure alone represented $78\%$ of the total failures. Those patients whose tumor sizes were less than 4 cm had a significantly better 5 year disease free survival than those with tumors greater than 4 cm $(0\%\;vs\;36\%)$. Those patients with a Karnofsky performance status less than 70 did not differ significantly with respect to actuarial survival when compared to those with a status greater than 70 $(25\%\;vs\;26\%,\;p>0.05)$. Conclusion : Radiation therapy 리one is an effective and safe treatment for early stage non-small ceil lung cancer patients who are medically inoperable or refuse surgery. Also we believe that a higher radiation dose to the primary site could improve the local control rate, and ultimately the overall survival rate.

The Effect of External Radiation Therapy in Management of Malignant Obstructive Jaundice due to Porta Hepatis Metastasis from Stomach Cancer (위암의 간문맥 전이로 발생한 악성 폐쇄성 황달에 대한 외부 방사선치료 효과)

  • Yang, Kwang-Mo;Kim, Joon-Hee;Kim, Chul-Soo;Suh, Hyun-Suk;Kim, Re-Hwe
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.339-348
    • /
    • 1995
  • Purpose : Since 1983, authors have conducted a study to evaluate the effect of external radiation therapy and to determine affected factors in management of the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. Materials and Methods : Thirty two patients with malignant obstructive jaundice due to porta hepatis metastasis from gastric cancer were presented. We have analysed 23 patients who were treated with external radiation therapy of more than 3000cGy. The radiation dose, disease extent at developement of jaundice, total bilirubin levels before radiation therapy, differentiation of histology, combind treatment, intent of primary surgery, initial stage of gastric cancer were analyzed to determine affected factors in radiation therapy. External radiation therapy was delivered with a daily dose of 180-300cGy, 5 times a week fractionation using 4 MeV linear accelerator. The radiation field included the porta hepatis with tumor mass by the abdominal ultrasonography or CT scan. In twenty three patients received more than 3000cGy, total irradiation dose was ranged from 3000cGy to 5480cGy, median 3770cGy. Among 23 patients, 13 patients were delivered more than equivalant dose of TDF 65(4140cGy/23fx). Results : Among 23 patients, complete, partial and no response were observed in 13, 5, 5 patients, respectively. The median survival for all patients was 5 momths. The significant prolongation of median survival was observed in complete responders(11 months) as compared to partial and no responders(5 months, 5 months respectively) Out of 13 patients with complete response, 6 patients lived more than a year Among 13 patients receiving more than 4140cGy equivalent dose, complete, partial and no response were observed in 10, 2 and 1 patients, respectively. The median survival for all these patients was 9.5 months. The median survival for complete responders(10/13) was 11.5 months. Among 10 patients receiving less than 4140cGy equivalent dose, complete, partial and no response were observed in 3, 3, 4 patients, respetively. The median survival for all these patients was 4.3 months Therefore, the radiation dose affected the results of treatment. For the complete response with prolongation of survival duration, at least 4140cGy equivalant dose should be delivered to porta hepatis. In evaluation of the disease extent, 7 patients of 13 complete responders showed localized disease in porta hepatis or peripancreatic area, but all patients with partial and no response showed wide extensive disease or persistant disease of primary gastric cancer. Therefore. the patients with the localized disease were the higher probability of complete response and long term survival. This study suggested that the radiation dose and the disease extent at developement of jaundice affected in radiation therapy for malignant obstructive jaundice. There were no serious complications related to external radiation therapy. Conclusion : External radiation therapy only could achieve the palliative effect in the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. This study suggested that the prolongation of survival duration could be achived in complete responders and radiation dose, extent of disease affected the results of treatment of malignant obstructive jaundice.

  • PDF

The Role of Intraluminal Brachytherapy in Management of Esophageal Cancer (식도암 치료에 있어 관내근접치료의 역할)

  • Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon;Chu Sung Sil;Chung Eun Ji;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.331-338
    • /
    • 1995
  • Purpose : To evaluate our clinical experience with the combination of teletherapy and intraluminal brachytherapy in patients with unresectable or inoperable esophageal cancers. Materials and Methods : From Nov 1989 to Mar 1993, twenty patients with esophageal cancer were treated with radical radiotherapy and intraluminal brachytherapy at Yonsei Cancer Center. All patients had squamous histolgy and stage distribution was as follows: stage II, 4($20{\%}$)patients; III, 15 ($75{\%}$)patients; IV, 1($5{\%}$)patients. A dose of S-12Gy/1-3weeks with intraluminal brachytherapy (3-5Gy/fraction) to 5mm from the outside of the esophageal tube using high dose rate Iridium-192 remotely afterloading brachytherapy machine was given 2 weeks after a total dose of 59-64Gy with external radiotherapy. Induction chemotherapy using cisplatin and 5-FU was performed in 13 patients with median 3 cycles(1-6 cycles), Response rate, local control rate, survival and complications were analysed retrospectively. Results : Two-year overall survival rate and median survival were $15.8{\%}$ and 13.5 months. Response rates were as follows complete remission(CR) 5($25{\%}$): partial remission a(PRa) 7($35{\%}$): partial remission b(PRb) 7($35{\%}$), no response(NR) 1($5{\%}$). Patterns of failure were as follows; local failure 13($65{\%}$), local and distant failure 3($15{\%}$), distant failure 0($0{\%}$). Ultimate local control rate was $20{\%}$. Treatment related complications included esophageal ulcer in two patients and esophageal stricture in one. Conclusion : Though poor local conrol rate, median survival was improved as compared with previous results of radiation therapy alone(8months) and chemoradiation combined treatment(11 months) in Yonsei Cancer Center High-dose-rate intraluminal brachytherapy following external irradiation is an effective treatment modality with acceptable toxicity in esophageal cancer.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Development of Formulas for the Estimation of Renal Depth and Application in the Measurement of Glomerular Filtration Rate in Koreans (사구체 여과율 측정을 위한 한국인의 신장 깊이에 관한 방정식 도출과 이용)

  • Yoo, Ie-Ryung;Kim, Sung-Hoon;Chung, Yong-An;Jung, Hyun-Seok;Lee, Hae-Giu;Park, Young-Ha;Lee, Sung-Yong;Sohn, Hyung-Seon;Chung, Soo-Kyo;Kim, Hyun-Mi;Lee, Hyung-Goo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.418-425
    • /
    • 2000
  • Purpose: There is no established formula for estimating renal depths in Korean. As a result, we undertook this study to develop a new formula, and to apply this formula in the calculation of glomerular filtration rate (GFR). Materials and Methods: We measured the renal depth (RD) on the abdominal CT obtained in 300 adults (M:F: 167:133, mean age 50.9 years) without known renal diseases. The RDs measured by CT were compared with the estimated RDs based on the Tonnesen and Taylor equations. New formulas were derived from the measured RDs in 200 out of 300 patients based on several variables such as sex, age, weight, and height by multiple regression analysis. The RDs estimated from the new formulas were compared with the measured RDs in the remaining 100 patients as a control. In 48 patients who underwent Tc-99m DTPA renal scintigraphy, GFR was measured with three equations (new formula, Tonnesen and Taylor equations), respectively, and compared with each other. Results: The mean values of the RDs measured from CT were 6.9 cm for right kidney of the men (MRK), 6.7 cm for left kidney of the men (MLK), 6.7 cm for right kidney of the women (WRK), and 6.6 cm for left kidney of the women (WLK). The RDs estimated from Tonnesen equation were shorter than the ones measured from CT significantly. The newly derived formulas were 12.813 (weight/height)+0.002 (age)+ 2.264 for MRK, 15.344 (weight/height)+0.011 (age)+0.557 for MLK, 12.936 (weight/height)+ 0.014 (age)+1.462 for WRK and 13.488 (weight/height)+0.019 (age)+0.762 for WLK. The correlation coefficients of the RD measured from CT and estimated from the new formula were 0.529 in MRK, 0.729 in MLK, 0.601 in WRK, and 0.724 in WLK, respectively. The GFRs from the new formula were significantly higher than those from the Tonnesen equation significantly, which was the most similar to normal GFR values. Conclusion: We generated new formulas for estimating RD in Korean from the data by CT. By adopting these formulas, we expect that GFR can be measured by the Gates method accurately in Korean.

  • PDF

The Plan of Dose Reduction by Measuring and Evaluating Occupationally Exposed Dose in vivo Tests of Nuclear Medicine (핵의학 체내검사 업무 단계 별 피폭선량 측정 및 분석을 통한 피폭선량 감소 방안)

  • Kil, Sang-Hyeong;Lim, Yeong-Hyeon;Park, Kwang-Youl;Jo, Kyung-Nam;Kim, Jung-Hun;Oh, Ji-Eun;Lee, Sang-Hyup;Lee, Su-Jung;Jun, Ji-Tak;Jung, Eui-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.26-32
    • /
    • 2010
  • Purpose: It is to find the way to minimize occupationally exposed dose for workers in vivo tests in each working stage within the range of the working environment which does not ruin the examination and the performance efficiency. Materials and Methods: The process of the nuclear tests in vivo using a radioactive isotope consists of radioisotope distribution, a radioisotope injection ($^{99m}Tc$, $^{18}F$-FDG), and scanning and guiding patients. Using a measuring instrument of RadEye-G10 gamma survey meter (Thermo SCIENTIFIC), the exposure doses in each working stage are measured and evaluated. Before the radioisotope injection the patients are explained about the examination and educated about matters that require attention. It is to reduce the meeting time with the patients. In addition, workers are also educated about the outside exposure and have to put on the protected devices. When the radioisotope is injected to the patients the exposure doses are measured due to whether they are in the protected devices or not. It is also measured due to whether there are the explanation about the examination and the education about matters that require attention or not. The total exposure dose is visualized into the graph in using Microsoft office excel 2007. The difference of this doses are analyzed by wilcoxon signed ranks test in using SPSS (statistical package for the social science) program 12.0. In this case of p<0.01, this study is reliable in the statistics. Results: It was reliable in the statistics that the exposure dose of injecting $^{99m}Tc$-DPD 20 mCi in wearing the protected devices showed 88% smaller than the dose of injecting it without the protected devices. However, it was not reliable in the statistics that the exposure dose of injecting $^{18}F$-FDG 10 mCi with wearing protected devices had 26% decrease than without them. Training before injecting $^{99m}Tc$-DPD 20 mCi to patient made the exposure dose drop to 63% comparing with training after the injection. The dose of training before injecting $^{18}F$-FDG 10 mCi had 52% less then the training after the injection. Both of them were reliable in the statistics. Conclusion: In the examination of using the radioisotope $^{99m}Tc$, wearing the protected devices are more effective to reduce the exposure dose than without wearing them. In the case of using $^{18}F$-FDG, reducing meeting time with patients is more effective to drop the exposure dose. Therefore if we try to protect workers from radioactivity according to each radioisotope characteristic it could be more effective and active radiation shield from radioactivity.

  • PDF

Primary Orbital Lymphoma : A Retrospective Analysis of Results of Radiation Therapy (원발성 안와 림프종의 방사선치료 성적에 관한 후향적 분석)

  • Kim Sussan;Ahn Seung Do;Chang Hyesook;Kim Kyoung Ju;Lee Sang-wook;Choi Eun Kyung;Kim Jong Hoon;Huh Jooryung;Suh Cheol Won;Kim Sung Bae
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.139-146
    • /
    • 2002
  • Purpose : This study evaluated the treatment outcomes, patterns of failure, and treatment related complications of primary lymphoma patients who received definitive radiation therapy. Materials and Methods : A retrospective analysis was undertaken for 31 patients with primary orbital lymphoma at the Asan Medical Center between February 1991 and April 2001. There were 18 males and 13 females with ages ranging from 3 to 73 years (median, 44 years). The involved sites were 9 conjunctivae, 12 eyelids and 10 other orbits. The histological types were 28 MALT lymphomas (low-grade B-cell lymphoma of mucosa-associated lymphoid tissue type), 1 diffuse large B-cell lymphoma, 1 anaplastic large cell lymphoma and 1 lymphoblastic lymphoma. The Ann Arbor stages were all IE $(100\%)$. Ann Arbor stage III or IV patients were excluded from this study, Bilateral orbital involvement occurred in 6 cases. Radiation therapy was given with one anterior port of high energy electrons $(6\~16\;MeV)$ for the lesions located at the anterior structures like the conjunctivae or eyelids. Lesions with a posterior extension or other orbital lesions were treated with 4 or 6 MeV photons with appropriately arranged portals. In particular, lens blocks composed of lead alloy were used in conjunctival or eyelid lesions. Twelve patients received chemotherapy. The median follow-up period was 53 months. Results : The 5-year overall, cause-specific, and disease-free survival was $91\%,\;96\%,\;and\;80\%$, respectively. The complete response rate 6 months after radiation therapy was $100\%$. Local recurrences were observed in 2 patients at 16 and 18 months after completion of radiation treatment. They were salvaged with additional radiation therapy. Two patients developed distant metastases. A MALT lymphoma patient with a lung relapse was successfully salvaged with radiotherapy, but the other lymphoblastic lymphoma patient with bone marrow relapse expired. There were no severe complications but 5 patients developed radiation-induced cataracts and 2 patients developed dry eye. Conclusion : Most primary orbital lymphomas consisted of MALT lymphomas. Radiation therapy was a successful treatment modality for orbital lymphoma without any severe complications. In cases of local relapses, radiation therapy is also a very successful salvage treatment modality.

Therapeutic Results of Radiotherapy in Rectal Carcinoma - Comparison of Sandwich Technique Radiotherapy with Postoperative Radiotherapy (직장암의 방사선 치료 결과 - Sandwich Technique 방사선 치료와 수술후 방사선 치료의 비교)

  • Huh Cil Cha;Suh Hyun Suk;Lee Hyuk Sang;Kim Re Hwe;Kim Chul Soo;Kim Hong Yong;Kim Sung Rok
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.25-31
    • /
    • 1996
  • Purpose : To evaluate the potential advantage for 'sandwich' technique radiotherapy compared to Postoperative radiotherapy in resectable rectal cancer. Materials and Methods : Between January 1989 and Mar 1994, 60 patients with resectable rectal cancer were treated at Inje University Seoul and Sanggye Paik Hospital. Fifty one patients were available for analysis: 20 patients were treated with sandwich technique radiotherapy and 31 patients were treated with Postoperative radiotherapy. In sandwich technique radiotherapy(RT), Patients were treated with preoperative RT 1500 cGy/5fx, followed by immediate curative resection. Patients staged as Astler-Coiler B2, C were considered for postoperative RT with 2500-4500 cGy. in postoperative RT total radiation dose of 4500-6120 cGy, 180 cGy daily at 4-Sweets was delivered. Patients were followed for median period of 25 months. Results : The overall 5-year survival rates for sandwich RT group and postoperative RT group were $60\%$ and $71\%$, respectively(p>0.05). The 5-rear disease free survival rates for each group were $63\%$. There was no difference in local failure rate between two groups($11\%$ versus $7\%$) Incidence of distant metastasis was $11\%$(2/20) in the sandwich technique RT group and $20\%$(6/31) in the postoperative RT group(p>0.05). The frequencies of acute and chronic complications were comparable in both groups. Conclusion : The sandwich technique radiotherapy group shows local recurrence and survival similar to those of Postoperative RT alone group but reduced distant metastasis compared to Postoperative RT group. But long term follow-up and large number of patients is needed to make an any firm conclusion regarding the value of this sandwich technique RT.

  • PDF

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).