• Title/Summary/Keyword: Materials and methods

Search Result 21,676, Processing Time 0.06 seconds

Smoking-Induced Dopamine Release Studied with $[^{11}C]Raclopride$ PET ($[^{11}C]Raclopride$ PET을 이용한 흡연에 의한 도파민 유리 영상 연구)

  • Kim, Yu-Kyeong;Cho, Sang-Soo;Lee, Do-Hoon;Ryu, Hye-Jung;Lee, Eun-Ju;Ryu, Chang-Hung;Jeong, In-Soon;Hong, Soo-Kyung;Lee, Jae-Sung;Seo, Hong-Gwan;Jeong, Jae-Min;Lee, Won-Woo;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.421-429
    • /
    • 2005
  • Purpose: It has been postulated that dopamine release in the striatum underlies the reinforcing properties of nicotine. Substantial evidence in the animal studies demonstrates that nicotine interacts with dopaminergic neuron and regulates the activation of the dopaminergic system. The aim of this study was to visualize the dopamine release by smoking in human brain using PET scan with $[^{11}C]raclopride$. Materials and Methods: Five male non-smokers or ex-smokers with an abstinence period longer than 1 year (mean age of $24.4{\pm}1.7$ years) were enrolled in this study $[^{11}C]raclopride$, a dopamine D2 receptor radioligand, was administrated with bolus-plus-constant infusion. Dynamic PET was performed during 120 minutes ($3{\times}20s,\;2{\times}60s,\;2{\times}120s,\;1{\times}180s\;and\;22{\times}300s$). following the 50 minute-scanning, subjects smoked a cigarette containing 1 mg of nicotine while in the scanner. Blood samples for the measurement of plasma nicotine level were collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, and 90 minute after smoking. Regions for striatal structures were drawn on the coronal summed PET images guided with co-registered MRI. Binding potential, calculated as (striatal-cerebellar)/cerebellar activity, was measured under equilibrium condition at baseline and smoking session. Results: The mean decrease in binding potential of $[^{11}C]raclopride$ between the baseline and smoking in caudate head, anterior putamen and ventral striatum was 4.7%, 4.0% and 7.8%, respectively. This indicated the striatal dopamine release by smoking. Of these, the reduction in binding potential in the ventral striatum was significantly correlated with the cumulated plasma level of the nicotine (Spearman's rho=0.9, p=0.04). Conclusion: These data demonstrate that in vivo imaging with $[^{11}C]raclopride$ PET could measure nicotine-induced dopamine release in the human brain, which has a significant positive correlation with the amount or nicotine administered bt smoking.

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF

Effect of Repetitive Transcranial Magnetic Stimulation in Drug Resistant Depressed Patients (치료 저항성 우울증 환자에서 반복적 경두개 자기자극후 국소뇌혈류 변화)

  • Chung, Yong-An;Yoo, Ie-Ryung;Kang, Bong-Joo;Chae, Jeong-Ho;Lee, Hye-Won;Moon, Hyun-Jin;Kim, Sung-Hoon;Sohn, Hyung-Sun;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.9-15
    • /
    • 2007
  • Purpose: Repetitive transcranial magnetic stimulation (rTMS) has recently been clinically applied in the treatment of drug resistant depressed patients. There are mixed findings about the efficacy of rTMS on depression. Furthermore, the influence of rTMS on the physiology of the brain is not clear. We prospectively evaluated changes of regional cerebral blood flow (rCBF) between pre- and post-rTMS treatment in patients with drug resistant depression. Materials and Methods: Twelve patients with drug-resistant depression (7 male, 5 female; age range: $19{\sim}52$ years; mean age: $29.3{\pm}9.3$ years) were given rTMS on right prefrontal lobe with low frequency (1 Hz) and on left prefrontal lobe with high frequency (20 Hz), with 20-minute-duration each day for 3 weeks. Tc-99m ECD brain perfusion SPECT was obtained before and after rTMS treatment. The changes of cerebral perfusion were analyzed using statistical parametric mapping (SPM; t=3.14, uncorrected p<0.01, voxel=100). Results: Following areas showed significant increase in rCBF after 3 weeks rTMS treatment: the cingulate gyrus, fusiform gyrus of right temporal lobe, precuneus, and left lateral globus pallidus. Significant decrement was noted in: the precental and middle frontal gyrus of right frontal lobe, and fusiform gyrus of left occipital lobe. Conclusion: Low-frequency rTMS on the right prefrontal cortex and high-frequency rTMS on the left prefrontal cortex for 3 weeks as an add-on regimen have increased and decreased rCBF in the specific brain regions in drug-resistant depressed patients. Further analyses correlating clinical characteristics and treatment paradigm with functional imaging data may be helpful in clarifying the pathophysiology of drug-resistant depressed patients.

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

Clinical Characteristics and Prognosis of Gastrointestinal Stromal Tumors of Stomach (위의 위장관 간질 종양의 임상적 특징 및 예후)

  • Kim, Min-Hyung;Hur, Hoon;Kim, Sin-Sun;Kim, Sung-Keun;Jeon, Kyung-Hwa;Song, Kyo-Young;Kim, Jin-Jo;Jin, Hyung-Min;Kim, Wook;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Jeon, Hae-Myung
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.146-153
    • /
    • 2006
  • Purpose: Gastrointestinal stromal tumorsm (GISTs) are the most common mesenchymal tumors that arise anywhere in the tubular GI tract. The prognosis for GSTIs is important because f GISTs may metastasiwx in the liver or the abdominal cavity in an early stage. For the reason we examined the tumor size, the mitotic number, ki 67, p53, and c-kit mutation as independent prognostic factor for GISTs. Materials and Methods: A retrospective study was conducted in 76 patients who had been re-evaluated for confirmation of diagnosis between Jan 1998 and Dec. 2001. at Catholic University of medicine. Results: There were significant difference between the turner size, mitotic indices, ki 67, c-kit mutations and the 5-years survival rates. Tumor size (${\geq}5\;cm$) and mitotic index (${\geq}5/50\;HPF$) were statistically related to a significantly poor prognosis (P=0.017 and P=0.042, respectively). c-kit mutations in exon 11 were found in 7 cases c-kit mutation was observed more frequently in high risk patients, and there was a significant difference between c-kit mutation and survival (P=0.037). Elevated ki 67 was noted in 34 out of the 76 cases. High risk patients showed elevated ki67 index more frequently and there was significant relation with the survival rate (P=0.0417). Conclusion: We think that tumor size, mitotic index, Ki 67 and c-kit mutation are as independent prognostic factors for GISTs, but more research is needed.

  • PDF

Psychophysiological Characteristics of Insomnia Patients Measured by Biofeedback System (바이오피드백을 이용하여 측정한 불면증 환자의 정신생리적 특징)

  • Huh, Sung-Young;Lee, Jin-Seong;Kim, Sung-Gon;Kim, Ji-Hoon;Jung, Woo-Young
    • Sleep Medicine and Psychophysiology
    • /
    • v.22 no.2
    • /
    • pp.70-76
    • /
    • 2015
  • Background and Objectives: Insomnia is the most prevalent sleep disorder in the general population and is considered to be a disorder of hyperarousal. The aim of this study was to measure the psychophysiological responses in insomnia patients using a biofeedback system, and to compare them with results from normal healthy subjects. Materials and Methods: Eighty patients with primary insomnia (35 males and 45 females, average age $49.71{\pm}12.91years$) and 101 normal healthy controls (64 males and 37 females, average age $27.65{\pm}2.77$) participated in this study. Electromyography (EMG), heart rate (HR), skin conductance (SC), skin temperature (ST), and respiratory rate (RR) were recorded using a biofeedback system during 5 phases (baseline, stress 1, recovery 1, stress 2, recovery 2) of a stress reactivity test, and average values were calculated. Difference in values between the two groups in each corresponding phase was analyzed with independent t-test, and change in values across phases of the stress reactivity test was analyzed with paired t-test (all two-tailed, p<0.05). Results: Compared to normal controls, insomnia patients had higher EMG in all 5 phases (baseline : $7.72{\pm}3.88{\mu}V$ vs. $4.89{\pm}1.73{\mu}V$, t = -6.06, p<0.001 ; stress 1 : $10.29{\pm}5.16{\mu}V$ vs. $6.63{\pm}2.48{\mu}V$, t = -5.84, p<0.001 ; recovery 1 : $7.87{\pm}3.86{\mu}V$ vs. $5.17{\pm}2.17{\mu}V$, t = -5.61, p<0.001 ; stress 2 : $10.22{\pm}6.07{\mu}V$ vs. $6.98{\pm}2.98{\mu}V$, t = -4.37, p<0.001 ; recovery 2 : $7.88{\pm}4.25{\mu}V$ vs. $5.17{\pm}1.99{\mu}V$, t = -5.27, p<0.001). Change in heart rate across phases of the stress reactivity test were higher in normal controls than in insomnia patients (stress 1-baseline : $6.48{\pm}0.59$ vs. $3.77{\pm}0.59$, t = 3.22, p = 0.002 ; recovery 1- stress 1 : $-5.36{\pm}0.0.59$ vs. $-3.16{\pm}0.47$, t = 2.91, p = 0.004 ; stress 2-recovery 1 : $8.45{\pm}0.61$ vs. $4.03{\pm}0.47$, t = 5.72, p<0.001 ; recovery 2-stress 2 : $-8.56{\pm}0.65$ vs. $4.02{\pm}0.51$, t = -5.31, p<0.001). Conclusion: Psychophysiological profiles of insomnia patients in a stress reactivity test were different from those of normal healthy controls. These results suggest that the sympathetic nervous system is more highly activated in insomnia patients.

Validity of Clinically Used Tray Transmission Factor (임상적으로 쓰이는 차폐선반투과율의 타당성에 관한 연구)

  • 윤형근
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.218-224
    • /
    • 2003
  • Purpose:By evaluating the dependence of the tray transmission factor (tray factor) on collimator setting and tray thickness, we determined the validity of the clinically used single tray factor for standard radiation field size (10${\times}$10 $\textrm{cm}^2$). Methods and Materials:For each X ray energies (6 and 10 MV), outputs were measured by using 5 steps of tray thickness (0, 6, 8, 10, 12 mm) and 7 steps of radiation field size (5${\times}$5, 10${\times}$10, 15${\times}$15, 20${\times}$20, 25${\times}$25, 30${\times}$30, 35${\times}$35 $\textrm{cm}^2$) at 10 cm phantom depth. Outputs were measured in both 'with tray' and 'without tray' conditions by using radiation with the same monitor units, and the tray factors were determined by the ratios of the two outputs. To evaluate the validity of a single tray factor obtained for standard radiation field, we analyzed the pattern of the field sizes in cases treated at our hospital in 2002. Results : In the 6 MV X-ray, the increases in the tray factor between the standard field (l0${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.835%, 1.058%, 1.066% in 6, 8, 10, and 12 mm thickness tray, respectively. In the 10 MV X-ray, the increases in the fray factor between the standard field (10${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.836%, 1.058%, 1.066% in 6, 8, 10, 12 mm thickness tray, respectively. In a major portion of clinical cases, when the field size was smaller than 20${\times}$20 $\textrm{cm}^2$, the tray factor was in good agreement with the standard tray factor. However, in cases where the field sizes were 30${\times}$30 $\textrm{cm}^2$ and 35${\times}$35 $\textrm{cm}^2$, the error could exceed 1.0%. Conclusion:The tray factor increased with increasing field size or decreasing tray thickness. The difference of tray factor between the small field and the large field increased with increasing tray thickness. Furthermore, the standard tray factor was valid in most clinical cases except for when the field size was greater than 30${\times}$30 $\textrm{cm}^2$, wherein the error could exceed 1.0%.

  • PDF

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Studies on the Estimation of Leaf Production in Mulberry Trees IV. Estimation of Spring Leaf Yield by the Measurement of Some Characters (상엽수확고 측정에 관한 연구 제 4보 추기상수각형질의 측정에 의한 익춘 상엽량의 예측)

  • 한경수;장권열;안정준
    • Journal of Sericultural and Entomological Science
    • /
    • v.10
    • /
    • pp.35-40
    • /
    • 1969
  • Various formulae for estimation of spring leaf production in mulberry trees were calculated and obtained. Four varieties of mulberry trees were used as the materials, and four characters, namely branch length (X$_1$), node number (X$_2$), branch diameter (X$_3$) and branch number per stock (X$_4$) were studied. The formulae to estimate the leaf yield of spring mulberry trees are as follows: 1. $Y_1$v$_1$= -26.8939+50.3950X$_1$+1.1403X$_2$ $Y_1$v$_2$= -372.1091+116.6371X$_1$+0.1984X$_2$ $Y_1$v$_3$= 149.8203+90.5125X$_1$-0.9775X$_2$ $Y_1$v$_4$= 108, 1496+59.4533X$_1$+1.4965X$_2$ Where $Y_1$v$_1$, $Y_1$v$_2$, $Y_1$v$_3$, $Y_1$v$_4$, are showed the estimated yield of the each variety, namely Gaeryang Seuban, Ilchirye, Nosang, and Suwon Sang No. 4, respectively. X$_1$ and X$_2$ denote the measured values of branch length and node number, respectively. 2. $Y_{7}$v$_1$= -54.4411+32.9869c1.1127X$_2$+21.7600X$_3$ $Y_{7}$v$_2$= -494.1480-1.8756X$_1$+0.9788X$_2$+110.0039X$_3$ $Y_{7}$v$_3$= 143.2836+29.1779X$_1$+0.1644X$_2$+48.4135X$_3$ $Y_{7}$v$_4$= 1243.2549+1.9454X$_1$+2.7118X$_2$-75.6669X$_3$ Where $Y_{7}$v$_1$, $Y_{7}$v$_2$, $Y_{7}$v$_3$, $Y_{7}$v$_4$, are the estimated yield of the each variety, namely Gaeryang-Seuban, Ilchirye, Nosang, Suwon Sang No 4, respectively. X$_1$, X$_2$, X$_3$ denote the measured values of each character, branch length, node number, branch diameter and branch number per stock, respectively. 3. $Y_{11}$v$_1$=233.4780+74.3713X$_1$+1.2912X$_2$+39.0420X$_3$-148.9300X$_4$ $Y_{11}$v$_2$=-317.0150+15.l524X$_1$+1.0861X$_2$+156.7973X$_3$-148.3742X$_4$ $Y_{11}$v$_3$=178.7011+29.8664X$_1$-0.2562X$_2$+102.4632X$_3$-83.2693X$_4$ $Y_{11}$v$_4$= 264.0062+47.7742X$_1$+2.6996X$_2$+92.8882X$_3$-192.3464X$_4$ Where $Y_{11}$v$_1$, $Y_{11}$v$_2$, $Y_{11}$v$_3$, $Y_{11}$v$_4$, are the estimated yield values of four varieties, and X$_1$, X$_2$, X$_3$, X$_4$, denote the measured values of four characters, namely branch length, node number, branch diameter and branch number per stock, respectively. The estimation method of mulberry spring leaf yield by measurement of some characters, in autumn the year before, could be the better method to determine the leaf yield of mulberry trees without destroying the leaves and without weighting the leaves of mulberry trees than the other methods.

  • PDF

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF