• Title/Summary/Keyword: Materials and methods

Search Result 21,838, Processing Time 0.062 seconds

Stability of $^{188}Re$ Labeled Antibody for Radioimmunotherapy and the Effect of Stabilizing Agents (방사면역치료용 $^{188}Re$ 표지 항체의 안정성과 안정제의 효과)

  • Chang, Young-Soo;Kim, Bo-Kwang;Jeong, Jae-Min;Chung, June-Key;Lee, Seung-Jin;Lee, Dong-Soo;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.195-202
    • /
    • 2002
  • Purpose: For clinical application of beta-emitter labeled antibody, high specific activity is imporiant. Carrier-free $^{188}Re$ from $^{188}W/^{188}Re$ generator is an ideal radionuclide for this purpose. However, low stability of $^{188}Re$ labeled antibody, especially in high specific activity, due to radiolytic decomposition by high energy (2.1 MeV) beta ray was problem. We studied the stability of $^{188}Re$ labeled antibody, and stabilizing effect of several stabilizers. Materials and Methods: Pre-reduced monoclonal antibody (CEA79.4) was labeled with $^{188}Re$ by incubating with generator-eluted $^{188}Re-perrhenate$ in the presence of stannous tartrate for 2 hr at room temperature. Radiochemical purity of each preparation was determined by chromatography. Human serum albumin was added to the labeled antibodies (2%). Stability of $^{188}Re-CEA79.4$ was investigated in the presence of ascorbic acid, ethanol, of Tween 80 as stabilizing agents. Results: Labeling efficiencies were $88{\pm}4%\;(n=12)$. Specific activities of $1.25{\sim}4.77MBq/{\mu}g$ were obtained. If stored after purging with $N_2$, all the preparations were stable for 10 hr. However, stability decreased in the presence of air. Perrhenate and $^{188}Re-tartrate$ was major impurity in declined preparation. colloid-formation was not a significant problem in all cases. Addition of ascorbic acid stabilized the labeled antibodies either under $N_2$ or under air by reducing the formation of perrhenate. Conclusion: High specific activity $^{188}Re$ labeled antibody is unstable, especially, in the presence of oxygen. Addition of ascorbic acid increased the stability.

f-MRI with Three-Dimensional Visual Stimulation (삼차원 시각 자극을 이용한 f-MRI 연구)

  • Kim C.Y.;Park H.J.;Oh S.J.;Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.24-29
    • /
    • 2005
  • Purpose : Instead of conventional two-dimensional (2-D) visual stimuli, three-dimensional (3-D) visual stimuli with stereoscopic vision were employed for the study of functional Magnetic Resonance Imaging (f-MRI). In this paper f-MRI with 3-D visual stimuli is investigated in comparison with f-MRI with 2-D visual stimuli. Materials and Methods : The anaglyph which generates stereoscopic vision by viewing color coded images with red-blue glasses is used for 3-D visual stimuli. Two-dimensional visual stimuli are also used for comparison. For healthy volunteers, f-MRI experiments were performed with 2-D and 3-D visual stimuli at 3.0 Tesla MRI system. Results : Occipital lobes were activated by the 3-D visual stimuli similarly as in the f-MRI with the conventional 2-D visual stimuli. The activated regions by the 3-D visual stimuli were, however, larger than those by the 2-D visual stimuli by $18\%$. Conclusion : Stereoscopic vision is the basis of the three-dimensional human perception. In this paper 3-D visual stimuli were applied using the anaglyph. Functional MRI was performed with 2-D and 3-D visual stimuli at 3.0 Tesla whole body MRI system. The occipital lobes activated by the 3-D visual stimuli appeared larger than those by the 2-D visual stimuli by about $18\%$. This is due to the more complex character of the 3-D human vision compared to 2-D vision. The f-MRI with 3-D visual stimuli may be useful in various fields using 3-D human vision such as virtual reality, 3-D display, and 3-D multimedia contents.

  • PDF

Prognostic Usefulness of Maximum Standardized Uptake Value on FDG-PET in Surgically Resected Non-small-cell Lung Cancer (수술로 제거된 비소세포폐암의 예후 예측에 있어 FDG-PET 최대 표준화 섭취계수의 유용성)

  • Nguyen Xuan Canh;Lee Won-Woo;Sung Sook-Whan;Jheon Sang-Hoon;Kim Yu-Kyeong;Lee Dong-Soo;Chung June-Key;Lee Myung-Chul;Kim Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.205-210
    • /
    • 2006
  • Purpose: FDG uptake on positron omission tomography (PET) has been considered a prognostic indicator in non-small cell lung cancer (NSCLC). The aim of this study was to assess the clinical significance of maximum value of SUV (maxSUV) in recurrence prediction in patients with surgically resected NSCLC. Materials & methods: NSCLC patients (n=42, F:M =14:28, age $62.3{\pm}12.3$ y) who underwent curative resection after FDG-PET were enrolled. Twenty-nine patients had pathologic stage 1, and 13 had pathologic stage II. Thirty-one patients were additionally treated with adjuvant oral chemotherapy. MaxSUVs of primary tumors were analyzed for correlation with tumor recurrence and compared with pathologic or clinical prognostic indicators. The median follow-up duration was 16 mo (range, 3-26 mo). Results: Ten (23.8%) of the 42 patients experienced recurrence during a median follow-up of 7.5 mo (range, 3-13 mo). Univariate analysis revealed that disease-free survival (DFS) was significantly correlated with maxSUV (<7 vs. $\geq7$, p=0.006), tumor size (<3 cm vs. $\geq3$ cm, p=0.024), and tumor tell differentiation (well/moderate vs. poor, p=0.044). However, multivariate Cox proportional analysis identified maxSUV as the single determinant for DFS (p=0.014). Patients with a maxSUV of $\geq7$(n=10) had a significantly lower 1-year DFS rate (50.0%) than those with a maxSUV of <7 (n=32, 87.5%). Conclusion: MaxSUV is a significant independent predictor for recurrence in surgically resected NSCLC. FDG uptake can be added to other well-known factors in prognosis prediction of NSCLC.

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

Assessment of Acquisition Protocols for Post-Radioembolization Yttrium-90 PET/CT: Initial Study (90Y SIR-Spheres를 사용한 암의 간 전이치료에서 PET 영상획득에 관한 초기연구)

  • Bahn, Young Kag;Oh, Shin Hyun;Kim, Jung Yul;Lee, Seung Jae;Park, Joon Young;Shin, Heui Soon;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.89-93
    • /
    • 2014
  • Purpose: We investigated the quantitative evaluation of PET/CT images for evaluation after treatment in the treatment of liver metastasis of cancer with $^{90}YSIR$-Sphere. Materials and Methods: Confirmed the correlation between the measured counts was expressed by setting a region of interest from the image and a measure of the dose calibrator to see a correlation diagram of an image in a PET of $^{90}Y$. A portion uptake coefficients between PET images were acquired for 20 minutes LIST mode in 15 patients treated for liver metastasis of cancer using $^{90}Y$ SIR-Spheres high, intermediate portion, a lower portion, three measuring the coefficient of the region of interest is divided into parts, we studied the conditions for proper image acquisition. Results: Coefficient of sites that set the region of interest of the PET image and the measured counts of $^{90}Yappears$ that there is a correlation diagram statistically, ($R^2=0.956$), correlation diagram from the PET image of $^{90}Yis$, PET coefficient the coefficients of all regions of interest were increased in proportion to the image acquisition time, partial ROI coefficients of the PET image is higher about 10 minutes on average, about 14 minutes on average, the central portion is lower part 19 minute average in, confirmed the equilibrium of the standard deviation. Conclusion: Using the isotope $^{90}Y$, it is suitable to obtain a PET image, to obtain the time of proper image, the evaluation of PET/CT images, using the $^{90}Y$ SIR-Spheres and that in the treatment of liver metastases of cancer, it is useful for assessing treatment.

  • PDF

Effect of gender on the pharmacokinetics and metabolite formation of sulfamethazine in the rabbit (토끼의 성차가 sulfamethazine의 약동학 및 대사산물 생성에 미치는 영향)

  • Yun, Hyo-in;Park, Il-hyun
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.1
    • /
    • pp.35-39
    • /
    • 1992
  • SMZ is one of the most widely used antibacterial agents in veterinary medicine. It is also used as a growth promotant in many species of domestic animals There are marked species differences in its metabolism and pharmacokinetics. However, its pharmacokinetic and metabolism in rabbits. which are ragarded not only as good laboratorty animals hut also as good economical animals in its own, are lacking. Sex-differences in drug metabolism are well recognized in wide range of animal species including rats. Males are known to he more active than females. It is also know that there are Significant differences in the direction of metabolic pathways. But recently, female goats are reported to be more active in the metabolie capacity of SMZ than the other sex by Dutch researchers at Utrecht. Therefore, it is not easy to make general conclusicn of having higher SMZ metal-die capacity in the male compared to the opposite sex in every animal species. In this regard, the study on metabolic pattern of SMZ in rabbits, which are regarded as hervivorous, is of interest because the dietary habbits of rabbit are comparable to thai of goal, NEW Zealand White rabbits of each sex were given SMZ(35mg/kg) as a bolus injection into the marginalean, vein in order to study its pharmacokinetic profiles(using plasma) anc metabolic pattem(24h urine) as specified in the methods anc materials. 1. In the rabbit, the major metabolic pathway of SMZ was the acetylation(the formation of $N_4AcSMZ$). There were hydroxylation pathways(50HSMZ, $6CH_2OHSMZ$) as well, in the metabolism of SMZ in the rabbit, but minor pathways. 2. No sex differences in the metabolic direction of SMZ and its metabolites formation were found from the urinary excreted metabolites of SMZ out of 24h collected urine. 3. The concentration-time curves of SMZ(35mg/kg, iv) in the plasma compartment were fitted to a one-compartment open model when using a computer program(NONLIN). There was also no difference in the pharmacokinetic pattem of SMZ between two sexes. 4. The emergence of $N_4AcSMZ$ metabolized from SMZ was very fast in the plasma of the rabbit The elimination of $N_4AcSMZ$ was prolonged as compared to that of the parent drug Vie found no sex difference in the elimination pattern of $N_4AcSMZ$ in the rabbit.

  • PDF

Usefulness of Breath-hold T2-weighted MR Imaging in Patients with Myocardial Infarction: Comparison with Delayed Enhancement (심근경색을 가진 환자에서 호흡정지 T2강조 자기공명영상의 유용성: 지연 조영증강 영상과의 비교)

  • Choi Sang Il;Kang Sung-Kwon;Ryu Won Hee;Lim Cheong;Choh Joong Haeng;Lee Whal;Jeong Jin-Wook;Park Jae-Hyung;Lee Kyung Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • Purpose : To evaluate the usefulness of breath-hold T2-weighted MR imaging in patients with myocardial infarction. Materials and Methods : We investigated 11 patients with myocardial infarction who shown delayed enhancement on MR imaging. Infarcted myocardium on T2-weighted MR imaging was classified as high, iso, and low signal area comparing with normal myocardium. The intensity and transmural extent of infracted myocardium was also analyzed. On the basis of clinical information, the stage of infracted myocardium on T2-weighted MR imaging was assessed. Results : It was observed high signal area in 12 segments of 5 patients, low in 12 segments of 6 patients on T2-weighted MR imaging. The high signal intensity of infarcted myocardium was shown as $175{\pm}9\%$ comparing with that of the normal myocardium, low signal intensity as $73{\pm}5\%\;(p\;<\;0.05)$. In the evaluation of transmural extent, the high signal areas on T2-weighted MR imaging were larger than infarct area on delayed enhancement imaging $(100\%\;vs.49\%{\pm}17\%)$, whereas low signal areas on T2-weighted MR imaging correlated. High signal area was visualized on T2-weighted MR imaging within 11 days, whereas low-signal area was seen after 7 months. Conclusion : Breath-hold T2-weighted MR imaging is useful in the evaluation of stage as well as edema and fibrous scar in patients with myocardial infarction.

  • PDF

Effect of adhesive hydrophobicity on microtensile bond strength of low-shrinkage silorane resin to dentin (접착시스템의 소수성이 Low-shrinkage silorane resin과 상아질의 미세인장강도에 미치는 영향)

  • Cho, So-Yeun;Kang, Hyun-Young;Kim, Kyoung-A;Yu, Mi-Kyung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.280-289
    • /
    • 2011
  • Objectives: The purpose of this study was to evaluate ${\mu}TBS$ (microtensile bond strength) of current dentin bonding adhesives which have different hydrophobicity with low-shrinkage silorane resin. Materials and Methods: Thirty-six human third molars were used. Middle dentin was exposed. The teeth were randomly assigned to nine experimental groups: Silorane self-etch adhesives (SS), SS + phosphoric acid etching (SS + pa), Adper easy bond (AE), AE + Silorane system bonding (AE + SSb), Clearfil SE bond (CSE), CSE + SSb, All-Bond 2 (AB2), AB2 + SSb, All-Bond 3 (AB3). After adhesive's were applied, the clinical crowns were restored with Filtek LS (3M ESPE). The 0.8 mm ${\times}$ 0.8 mm sticks were submitted to a tensile load using a Micro Tensile Tester (Bisco Inc.). Water sorption was measured to estimate hydrophobicity adhesives. Results: ${\mu}TBS$ of silorane resin to 5 adhesives: SS, 23.2 MPa; CSE, 19.4 MPa; AB3, 30.3 MPa; AB2 and AE, no bond. Additional layering of SSb: CSE + SSb, 26.2 MPa; AB2 + SSb, 33.9 MPa; AE + SSb, no bond. High value of ${\mu}TBS$ was related to cohesive failure. SS showed the lowest water sorption. AE showed the highest solubility. Conclusions: The hydrophobicity of adhesive increased, and silorane resin bond-strength was also increased. Additional hydrophobic adhesive layer did not increase the bond-strength to silorane resin except AB2 + SSb. All-Bond 3 showed similar ${\mu}TBS$ & water sorption with SS. By these facts, we could reach a conclusion that All-Bond 3 is a competitive adhesive which can replace the Silorane adhesive system.

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.

A Study on the Thermal Conductivity Measurement for Planting Mats of Landscaping (조경용 식생매트의 열전도율 측정에 관한 연구)

  • Cha, Uk Jin;Yang, Geon Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.85-96
    • /
    • 2018
  • Developed nations have implemented various policies to reduce greenhouse gases since the 1997 Kyoto Protocol in order to minimize the effects of global warming. Korea should also reduce energy consumption in the industrial sector, and the transportation and building sectors in order to achieve its greenhouse gas reduction target of 37 percent compared to the Business As Usual levels. The government implements various laws and regulations for reducing energy consumption. To reduce energy consumption in the building sector, in particular, the Energy Conservation Design Standards are enforced according to the 'Enforcement Support for Green Building Construction'. The amount of electricity used to maintain room temperature at $28^{\circ}C$ in these buildings have a 30% reduction (measured on the walls and rooftop) in power usage compared to buildings not required to meet these standards. Although the effect of these energy savings on landscaping is proven, this demonstration is not effective for energy saving since it is not a suitable method for the 'Energy Saving Design Standards of Buildings'. For landscaping to be effective as far as a component of energy reduction, the perfusion rate of the building should be calculated based on the thermal conductivity of the component materials for the energy saving designs with respect to the basis of Article 14 of the Green Building Act. Therefore, the purpose of this study is to ensure that the planting-based mats currently being widely used in the landscape industry can have insulating performance suitable for the 'Energy Saving Design Standards' of Buildings according to the 'Enable Green Building Construction Methods'.