Assessment of Acquisition Protocols for Post-Radioembolization Yttrium-90 PET/CT: Initial Study

90Y SIR-Spheres를 사용한 암의 간 전이치료에서 PET 영상획득에 관한 초기연구

  • Bahn, Young Kag (Department of Nuclear Medicine, Yonsei University Health System) ;
  • Oh, Shin Hyun (Department of Nuclear Medicine, Yonsei University Health System) ;
  • Kim, Jung Yul (Department of Nuclear Medicine, Yonsei University Health System) ;
  • Lee, Seung Jae (Department of Nuclear Medicine, Yonsei University Health System) ;
  • Park, Joon Young (Department of Nuclear Medicine, Yonsei University Health System) ;
  • Shin, Heui Soon (MI Team, GE Healthcare Korea) ;
  • Lim, Han Sang (Department of Nuclear Medicine, Yonsei University Health System) ;
  • Kim, Jae Sam (Department of Nuclear Medicine, Yonsei University Health System)
  • 반영각 (연세의료원 세브란스병원 핵의학과) ;
  • 오신현 (연세의료원 세브란스병원 핵의학과) ;
  • 김정열 (연세의료원 세브란스병원 핵의학과) ;
  • 이승재 (연세의료원 세브란스병원 핵의학과) ;
  • 박준영 (연세의료원 세브란스병원 핵의학과) ;
  • 신희순 ;
  • 임한상 (연세의료원 세브란스병원 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원 핵의학과)
  • Received : 2014.03.28
  • Accepted : 2014.04.21
  • Published : 2014.05.23

Abstract

Purpose: We investigated the quantitative evaluation of PET/CT images for evaluation after treatment in the treatment of liver metastasis of cancer with $^{90}YSIR$-Sphere. Materials and Methods: Confirmed the correlation between the measured counts was expressed by setting a region of interest from the image and a measure of the dose calibrator to see a correlation diagram of an image in a PET of $^{90}Y$. A portion uptake coefficients between PET images were acquired for 20 minutes LIST mode in 15 patients treated for liver metastasis of cancer using $^{90}Y$ SIR-Spheres high, intermediate portion, a lower portion, three measuring the coefficient of the region of interest is divided into parts, we studied the conditions for proper image acquisition. Results: Coefficient of sites that set the region of interest of the PET image and the measured counts of $^{90}Yappears$ that there is a correlation diagram statistically, ($R^2=0.956$), correlation diagram from the PET image of $^{90}Yis$, PET coefficient the coefficients of all regions of interest were increased in proportion to the image acquisition time, partial ROI coefficients of the PET image is higher about 10 minutes on average, about 14 minutes on average, the central portion is lower part 19 minute average in, confirmed the equilibrium of the standard deviation. Conclusion: Using the isotope $^{90}Y$, it is suitable to obtain a PET image, to obtain the time of proper image, the evaluation of PET/CT images, using the $^{90}Y$ SIR-Spheres and that in the treatment of liver metastases of cancer, it is useful for assessing treatment.

$^{90}Y$ SIR-Sphere 를 사용한 암의 간 전이치료에서 치료 후 평가를 위한 PET/CT 영상에 대한 정량적 평가를 연구해보고자 하였다. $^{90}Y$ 의 PET 에서의 영상의 상관도를 보기 위해 Dose calibrator 의 측정치와 영상에서 관심영역을 설정하여 나타낸 측정치와의 상관도를 확인하였다. 그리고 90Y SIR-Spheres 를 사용하여 암의 간 전이치료를 받은 15명의 환자에서 20분간 LIST mode로 획득한 PET 영상에서 간의 섭취계수가 높은 부분, 중간 부분, 낮은 부분, 세 부분으로 나누어 관심영역의 계수를 측정하여 적정 영상 획득 조건을 연구하였다. $^{90}Y$ 의 PET 영상에서의 상관도는 Y-90 의 측정치와 PET영상의 관심영역을 설정한 부위의 계수는 통계적으로 상관도가 있다고 나타났고($R^2=0.956$), PET 계수는 모든 관심영역의 계수는 영상획득시간에 따라 비례하여 증가 하였다 그러나, PET 영상의 관심영역 계수가 높은 부분은 평균 약 10분, 중간 부분은 평균 약 14분, 낮은 부분은 평균 19분에서 표준편차의 평형을 나타냈다. $^{90}Y$의 동위원소를 이용하여 PET 영상을 획득하는데 적합하였고, PET/CT 영상 평가는 적절한 영상 시간을 획득한다면, $^{90}Y$ SIR-Spheres 를 사용한 암의 간 전이치료에서 치료 후 평가에 유용할 것이다.

Keywords