• 제목/요약/키워드: Matching frequency

Search Result 940, Processing Time 0.032 seconds

Prostatic Bleeding after Prostatic Biopsy Effects Oncological Outcomes with Laparoscopic Radical Prostatectomy

  • Takai, Tomoaki;Inamoto, Teruo;Komura, Kazumasa;Tsujino, Takuya;Matsunaga, Tomohisa;Yoshikawa, Yuki;Uchimoto, Taizo;Saito, Kenkichi;Tanda, Naoki;Minami, Koichiro;Uehara, Hirofumi;Ibuki, Naokazu;Takahara, Kiyoshi;Nomi, Hayahito;Kiyama, Satoshi;Azuma, Hayahito
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1373-1377
    • /
    • 2016
  • Background: We vigorously reviewed patients' operation record who had adhesion of the Denonvilliers' fascia and found out most of these patients had prostatic bleeding after prostatic gland biopsies. We examined the magnitude of prostatic bleeding and frequency after biopsies and the relationship with oncological outcomes. Materials and Methods: A total of 285 patients were selected for the final analyses. Inclusion criteria were as follows: receiving MRI three weeks after biopsiesand laparoscopic radical prostatectomy within 300 days after biopsy. We divided the patients into two groups with (group A) or without (group B) prostatic bleeding. We examined the magnitude of prostatic bleeding after biopsies and the relationship with operation time (OT), positive surgical margin (PSM), biochemical recurrence (BCR) and other factors. Furthermore, we created a logistic-regression model to derive a propensity score for prostatic bleeding after biopsies, which included all patient and hospital characteristics as well as selected interaction terms, and we examined the relationship with PSM and BCR. Results: In all patients, the OT in the group B was shorter than the group A (p < 0.001). Prostatic bleeding was associated with PSM (p=0.000) and BCR (p=0.036). In this propensity-matched cohort, 11 of 116 patients in the group B had PSM as compared with 36 of 116 patients from group A (match-adjusted odds ratio, 4.30; 95%CI confidence interval, 2.06 to 8.96; P=0.000). In addition, eight of 116 patients in group B encountered BCR, as compared with 18 of 116 patients in group A (match-adjusted odds ratio, 2.48; 95%CI, 1.03 to 5.96; P=0.042). Kaplan-Meier analysis in the propensity matching cohort showed a significant biochemical recurrence-free survival advantage for being free of prostate bleeding after biopsies. Conclusions: Our findings in the present cohort should help equip surgeons to pay attention to careful excision especially for those who experienced deferred prostatic bleeding.

Design of a Novel Instrumentation Amplifier using Current-conveyor(CCII) (전류-컨베이어(CCII)를 사용한 새로운 계측 증폭기 설계)

  • CHA, Hyeong-Woo;Jeong, Tae-Yun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.80-87
    • /
    • 2013
  • A novel instrumentation amplifier(IA) using positive polarity current-conveyor(CCII+) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of two CCII+, three resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into two CCII+ used voltage and current follower converts into same currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the CCII+ and used commercial op-amp LF356. Simulation results show that voltage follower used CCII+ has offset voltage of 0.21mV at linear range of ${\pm}$4V. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the gain of 60dB was 400kHz. The IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 130mW at supply voltage of ${\pm}$5V.

Microwave Absorbing Properties of Silver-coated Ni-Zn Ferrite Spheres Prepared by Electroless Plating (무전해 도금법에 의해 제조된 은 피복 Ni-Zn Ferrite Sphere의 전파흡수특성)

  • Kim, Jong-Hyuk;Kim, Jae-Woong;Kim, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.3
    • /
    • pp.202-206
    • /
    • 2005
  • The present investigation provides an electromagnetic radiation absorptive composition which comprises silver-coated ferrite microspheres dispersed in silicon rubber matrix for the aim of thin microwave absorber in GHz frequencies. Ni-Zn ferrite spheres with $50{\mu}m$ size in average were prepared by spray-drying and sintering at $1130^{\circ}C$. Conductive silver layer was plated on ferrite spheres by electroless plating. Conductive Ni-Zn ferrite sphere with uniform silver layer were obtained in the concentration of 10 g/L $AgNO_3$ per 20 g ferrite spheres. For this powder, electrical resistance is reduced as low as $10^{-2}\~10^{-3}\;\Omega$. The most sensitive material parameters with silver plating is real and imaginary parts of complex permittivity. The conductive Ni-Zn ferrite spheres have large values of dielectric constant. Due to this high dielectric constant of microspheres, matching thickness is reduced to as low as 2 mm at the frequency of 7 GHz, which is much thinner than conventional ferrite absorbers.

Design of a LTCC Front End Module with Power Detecting Function (전력 검출 기능을 포함하는 LTCC 프런트 엔드 모듈 설계)

  • Hwang, Mun-Su;Koo, Jae-Jin;Koo, Ja-Kyung;Lim, Jong-Sik;Ahn, Dal;Yang, Gyu-Yeol;Kim, Jun-Chul;Kim, Dong-Su;Park, Ung-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.844-853
    • /
    • 2008
  • This paper describes the design of a FEM(Front End Module) having power detection function for mobile handset application. The designed FEM consists of a MMIC(Monolithic Microwave Integrated Circuits) power amplifier chip, SAW Tx filter and duplexer, diode power detector and stripline matching circuit. An LTCC(Low Temperature Co-fired Ceramics) technology is adopted for miniaturized FEM. The frequency band is $824{\sim}869$ MHz which is the uplink Tx band of the CDMA mobile system. The size of designed FEM is $7.0{\times}5.5{\times}1.5\;mm^3$, which is an ultra-small size even though the power detector circuit is included. All sub-components of FEM have been developed and measured in advance before being integrated into FEM. The measured output power and gain are 27 dBm and 27 dB, respectively. In addition, the measured ACPR characteristics are 46.59 dBc and 55.5 dBc at 885 kHz and 1.98 MHz offset, respectively.

Implementation of Readout IC for $8\times8$ UV-FPA Detector ($8\times8$ UV-PPA 검출기용 Readout IC의 설계 및 제작)

  • Kim, Tae-Min;Shin, Gun-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.503-510
    • /
    • 2006
  • Readout circuit is to convert signal occurred in a defector into suitable signal for image signal processing. In general, it has to possess functions of impedance matching with perception element, amplification, noise reduction and cell selection. It also should satisfies conditions of low-power, low-noise, linearity, uniformity, dynamic range, excellent frequency-response characteristic, and so on. The technical issues in developing image processing equipment for focal plane way (FPA) can be categorized as follow: First, ultraviolet (UV) my detector material and fine processing technology. Second, ReadOut IC (ROIC) design technology to process electric signal from detector. Last, package technology for hybrid bonding between detector and ROIC. ROIC enables intelligence and multi-function of image equipment. It is a core component for high value added commercialization ultimately. Especially, in development of high-resolution image equipment ROIC, it is necessary that high-integrated and low-power circuit design technology satisfied with design specifications such as detector characteristic, signal dynamic range, readout rate, noise characteristic, ceil pitch, power consumption and so on. In this paper, we implemented a $8\times8$ FPA prototype ROIC for reduction of period and cost. We tested unit block and overall functions of designed $8\times8$ FPA ROIC. Also, we manufactured ROIC control and image boards, and then were able to verify operation of ROIC by confirming detected image from PC's monitor through UART(Universal Asynchronous Receiver Transmitter) communication.

A Study on the Energy-saving Variation by the Reduction of Insulation Boundary in Mixed-use Building (주상복합건물에서 단열 경계구역 축소에 따른 에너지 절감량 변화에 관한 연구)

  • Kim, Dae-Won;Kim, Young-Il;Kim, Sung-Min;Cho, Jin-Hwan;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.152-157
    • /
    • 2012
  • Due to the global warming and energy exhaustion, energy efficiency improvement of construction is recognized the stream of times. To improve the efficiency of the building, in order to energy saving, passive elements should be applied. Then the first step be supposed that applying the new standards about the insulation boundary. The current insulation boundary standards are not reasonable as well as does not divide the purposes. As a result, energy is being wasted and many civil complaints are also occurred. To improve these problems, applying the insulation boundary need to divide the heating and non-heating and subdivide the purpose of construction. In this study, accurate real heating and air conditioning areas are presented that work on the new insulation boundary of purposes and applicable standards. This proposed, by the real heating and air conditioning areas, insulation boundary of purposes, matching the reasonable capacity and load of equipment, by working on standards by optimal maintenance can be energy saving, to present guidelines that environment improvement of actual residents as well as energy saving be expected.

Effects of Mother's Oral Health Care Behaviors on Dental Caries in Primary School Children (어머니의 구강보건관리행태가 초등학교 아동의 치아우식에 미치는 영향)

  • Kim, Young-Nam;Song, Yun-Sin;Kim, Yoon-Shin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.1
    • /
    • pp.145-156
    • /
    • 2012
  • Objectives : By analyzing the affects of the mother's oral care to the caries experiences of the elementary school children, To looking for the way to prevent dental caries in the primary school, to provide baseline data to perform the associated oral health education. Methods : Between the 3,676 children's dental check-up data and the 2,934 survey of parents from 9 elementary schools in the the Gyeonggi Province, the exactly matching data of 2,358 pairs, children versus mothers, were analyzed during the period, 2009 May 4 to July 20, By using the PASW 18(SPSS-PC 18), Frequency analysis of the collected data, and cross-analysis, ANOVA, Bonferroni post-analysis was performed. Results : The findings of the study were as follows. 1. In children, the ratio(DMF rate)of the dental caries experience in permanent teeth, appeared higher for men than women. Divided by grade level, the ratio of caries experience in the permanent teeth(DMF rate) generally appear higher in older than young. Thus between the child's gender and grade level by the ratio of caries experience in the permanent teeth(DMF rate) showed the statistically significant differences (p<0.05). 2. Between the socioeconomic characteristics of mothers and the children's level of dental caries experiences, not showed the statistically significant difference.(p>0.05). 3. The significant difference showed between the dental caries levels of the children and the mother's oral health care behavior - a toothbrush replacement period, mother's broken teeth, mothers guidances of the brushing after snacks for children(p<0.05). Conclusions : The mother's oral health attitudes and behaviors can affect to their children's oral care habits. Therefore The mother themselves should have the right proper habit of oral health care, so that in oral health care mothers should be the model for their children. Institutionally more systematic and detailed oral health educational program in conjunction with the family is needed.

Fabrication of Lightweight Microwave Absorbers with Co-coated Hollow Silica Microspheres (저밀도 실리카 중공미세구 표면에 Co 박막의 코팅에 의한 경량 전파흡수체 제조)

  • Kim, Sun-Tae;Kim, Sung-Soo;Ahn, Jun-Mo;Kim, Keun-Hong
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.67-75
    • /
    • 2005
  • For th aim of lightweight microwave absorbers, conductive and magnetic microspheres are fabricated by plating of Co films on hollow ceramic microspheres of low density. Metal plating was carried out in a two-step electroless plating process (pre-treatment of activation and plating). Uniform coating of the film with about $2{\~}3{\cal}um$ thickness was identified by SEM. High-frequency magnetic and microwave absorbing properties were determined in the rubber composites containing the Co-coated microspheres. Due to conductive and ferromagnetic behavior of the Co thin films, high dielectric constant and magnetic loss can be obtained in the microwave frequencies. Due to those electromagnetic properties, high absorption rate (25 dB) and thin matching thickness ($2.0{\~}2.5{\cal}mm$) are predicted in the composite layers containing the metal-coated microspheres of low density (about 0.84 g/cc) for the electromagnetic radiation in microwave frequencies.

Efficient Second Harmonic Generation of a High-power Yb-doped Fiber MOPA Incorporating MgO:PPSLT (MgO:PPSLT를 이용한 고출력 Yb 광섬유 레이저 빔의 고효율 이차조화파 변환)

  • Song, Seungbeen;Park, Eunji;Park, Jong Sun;Oh, Yejin;Jeong, Hoon;Kim, Ji Won
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.3
    • /
    • pp.142-147
    • /
    • 2020
  • In this paper, we report highly efficient second harmonic generation of continuous-wave Yb fiber lasers incorporating a periodically poled LiTaO3 device (MgO:PPSLT) as a frequency converter. The seed laser output from a Yb fiber master oscillator using a Fabry-Perot feedback cavity was amplified in a Yb fiber amplifier stage, yielding 28.5 W of linearly polarized output at 1064 nm in a beam with beam quality, M2, of ~1.07. Second harmonic generation was achieved by passing the laser beam through MgO:PPSLT. Under optimized conditions, we obtained 11.1 W of green laser output at 532 nm for an incident signal power of 25.0 W at 1064 nm, corresponding to a conversion efficiency of 44.4%. The detailed investigation to find the optimized operating conditions and prospects for further improvement are discussed.

A Design of Novel Instrumentation Amplifier Using a Fully-Differential Linear OTA (완전-차동 선형 OTA를 사용한 새로운 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • A novel instrumentation amplifier (IA) using fully-differential linear operational transconductance amplifier (FLOTA) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of a FLOTA, two resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into FLOTA converts into two same difference currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the FLOTA and realized the IA used commercial op-amp LF356. Simulation results show that the FLOTA has linearity error of 0.1% and offset current of 2.1uA at input dynamic range ${\pm}3.0V$. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the 60dB was 10MHz. The proposed IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 105mW at supply voltage of ${\pm}5V$.