Journal of the Korea Institute of Building Construction
/
v.13
no.6
/
pp.513-521
/
2013
This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.
Journal of the Korean Society of Manufacturing Process Engineers
/
v.14
no.5
/
pp.134-140
/
2015
A control program of an engine control module (ECM) was developed, and its control performance was verified on a 750Ps marine diesel engine. The control method was designed for an engine rotational speed control system. For ECM hardware, the commercial rapid control prototype (RCP) ECM was used. The programming tool for control algorithm development was the MatLab/Simulink. The main control algorithm assembled many control models as engine cranking, run, and stall. Each model has sub-models to input/output control signals. The target engine speed was input signal from a speed control lever, and control output signal of the ECM was sent to the unit-injectors for fuel injection. The engine test was performed under various conditions of engine rotational speeds and dynamometer loads. The test results show that the control function of the ECM is suitable for electrical marine diesel engines.
In this study, epoxidized bisphenolic resins laminated with glass fiber mat(GFRP) are ivestigated on surface, bulk aspect and dielectric constant(${\varepsilon}'$ and ${\varepsilon}''$) vs. frequency characteristics with temperature. The investigation shows the different characteristics accordig to the attachments of fiber surface, filler content, matrix properties, and the others. Especially, dielectric properties of this sample are highly increased above $100^{\circ}C$ and decreased with the rise of frequency. There is a resonance at the high frequency region ($1MHz{\sim}10MHz$). So, dielectric properties show the shift with frequency and temperature. Dielectric properties of EGL 10 are higher than those of EGL 40 with the frequency. Generally, dielectric properties of EGL 10 are more unstable than those of EGL 40 on the shift of frequency and temperature.
Purpose: The purpose of this study was to examine the muscle activity of the trunk muscles during balance exercises on a stable and unstable surface in patients with stroke. Methods: Thirteen subjects (8 males, 5 females) with stroke were enrolled in the study. Muscle activity was recorded using surface EMG electrodes from the affected side of the erector spinae, external oblique, and internal oblique muscles. The exercise was performed under three conditions. For the first condition for balance exercise, subjects were instructed to sit on an exercise mat with legs extended. The second condition was to sit with legs extended, with a balance pad under their buttocks. The third condition was to sit with legs extended, have a balance pad under the buttocks and a balance cushion under the lower legs. Results: This study showed significant differences in EMG activities during both arm lifting exercise and weight shifting exercise between conditions. This study showed that the EMG activities of the erector spinae, external oblique, and internal oblique muscles were significantly higher when the trunk exercise was performed using the balance pad with balance ball than when using the stable surface. Conclusion: In conclusion, performing balance exercises using an unstable surface is a useful method for facilitating trunk-muscle strength and hence trunk stability.
The effect of plastic board drains (PBDs)on ground improvement was checked out considering three crucial factors: ground settlement, undrained shear strength, and residual water head. First, the settlement analysis including initial settlement induced by reclamation of sand mat was conducted by back calculation analysis with measured data. Its result showed toot the PBDs used for this site worked well on improving soft ground. Secondly, the undrained shear strength was investigated by laboratory and in-situ tests including unconsolidated-undrained triaxial compression (UU) tests, unconfined compression tests, in-situ vane tests, and cone penetration tests. From the test results, they showed that the undrained shear strength of the improved ground by PBDs was significantly increased as well as the strength increasing ratio especially $10{\sim}15m$ below the ground surface on site. Thirdly, the residual water head measurement from the in situ dissipation test was found the same as the static water head, which indicated primary consolidation was completed and the effect of soil improvement with PBDs can be confirmed.
In this study, the ecological characteristics of Limnoperna fortunei were surveyed as a preceding research to solve the problem such as biofouling or biowaste caused by those organisms in the closed water pipeline. Limnoperna fortunei was collected not in the main reaches of Somjin River but inside and outside of the intake tower which is located in the lower part of Sueo Reservoir. The dense populations were found at the inlet mouth and near part of the pipeline. Their byssuses were formed as a thick and tightly interwind mat. The rusted parts of the pipeline hold relatively more shells than those of the normal parts. Average count of the numbers ranged $12.1{\sim}136.5ind./m^2$ through the sampling stations (A,B and C). The amount of attached shells at each station were A=386, B=258, and C=71, respectively. The relationships of shell height-length and shell length-width were proportional. The majority sizes in each station ranged A=20.01~22.00 mm (33.9%), B=10.01~14.00 mm (51.2%), and C=18.01~20.00 mm (22.5%), 24.01~26.00 mm (21.1%), respectively. Most of the bigger size of shells on C station was found dead. The ecological habitat seemed less suitable for Limnoperna fortunei when they located farther away from the intake tower of reservoir. From now on, it is necessary to consider the continuous monitoring of this organism.
Mullite-PSZ composite was prepared by sol-gel method using $Al(sec-OC_4H_9)_3,\;Si(OC_2H_5)_4,\;ZrOCl_2\;8H_2O\;and\;Y_2O_3$. The sinterability ana mechanical properties of powder compacts sintered at $1,650^{\circ}C$ for 4 hrs were investigated for various PSZ contents. In result Al-Si spinel formed at $980^{\circ}C$ from amorphous dried gel, and zirconia as well as mullite crystal formed above $1,200^{\circ}C$. The sintered body was densified to $97{\sim}98%$ except the specimen containing 25vol% PSZ which showed the relative density of about 95% obtained by sintering at $1,650^{\circ}C$ for 4 h. The flexural strength of the sintered body was a maximum value of 290 MPa in 20 vol% PSZ, which was also considerably larger than the value of 200 MPa without PSZ. The value of the fracture toughness increased linearly with increase of PSZ content and showed a maximum value of $4.3MPam^{1/2}$ in 25 vol% PSZ, Namely this value was remarkably larger than the $value(2.6MPam^{1/2})$ of pure mullite without PSZ.
Ion exchange resin complexes of famotidine have been prepared by the reaction of famotidine solution with activated ion exchange resins. Complex formation efficiency between famotidine and ion exchange resin was about $80{\sim}90%$ in average, calculated by HPLC determination. Drug release characteristics from the resin complexes were evaluated by the modified percolation method. Famotidine release was dependent on the type of ion exchange resins. In the case of weakly acidic resin complexes, the cumulative released amount of famotidine was more than 90% for 1hr in pH 1.2 buffer solution. However, in the case of strongly acidic resin complexes, it was less than 5% for 3hr in the same medium. Strongly acidic resins revealed some advantages over weakly, acidic resins for overcoming instability of famotidine in gastric juice. In addition, strongly acidic resin complexes showed controlled release of famotidine in pH 6.8 buffer solution, showing the result of about 60 to 70% of drug release for 5hr. After oral administrations of famotidine-resin complexes to rats as dose of 40 mg equivalent/kg, the pharmacokinetic parameters of famotidine were obtained by model independent analysis and compared with those of famotidine solution or suspension. $C_{max}$ of famotidine-resin complex was lower than that of famotidine solution or suspension. MRT, MAT, and MDT of the complexes were greater than those of famotidine solution or suspension. From these results, it was expected that famotidine was released slowly from the complexes and absorbed continuously into systemic circulation. It was recognized that drug release from the complexes was the rate-limiting step in drug absorption, since there were close correlations between in vitro drug release and in vivo pharmacokinetic parameters.
Kim, Sang-Suk;Park, Ik-Min;Kim, Sung-Joon;Choi, Il-Dong
Journal of Korea Foundry Society
/
v.17
no.4
/
pp.338-346
/
1997
Mechanical properties of ($10%Al_2O_3{\cdot}SiO_2+5%Ni$)/Al hybrid composites fabricated by the reaction squeeze casting were compared with those of ($15%Al_2O_3{\cdot}SiO_2$)/Ai composites. Al-Ni intermetallic compounds ($10{\sim}20 {\mu}m$) formed by the reaction between nickel powder and molten aluminum were uniformly distributed in the Al matrix. These intermetallic compounds were identified as $Al_3Ni$ using X-ray diffraction analysis and they resulted in beneficial effects on room and high temperature strength and wear resistance. Microhardness values of ($10%Al_2O_3{\cdot}SiO_2+5%Ni$)/Al hybrid composite were greater by about 100Hv than those of ($15%Al_2O_3{\cdot}SiO_2$)/Al composite. Wear resistance of ($10%Al_2O_3{\cdot}SiO_2+5%Ni$)/Al hybrid composites was superior to that of ($15%Al_2O_3{\cdot}SiO_2$)/Al composites regardless of the applied load. While tensile and yield strength of ($10%Al_2O_3{\cdot}SiO_2+5%Ni$)/Al hybrid composites were greater at room temperature and $300^{\circ}C$, strength drop at high temperature was much smaller in hybrid composites.
Park, Jong-Han;Han, Kyung-Sook;Han, You-Kyoung;Lee, Jung-Sup;Kim, Dae-Hyun;Hwang, Jeong-Hwan
Research in Plant Disease
/
v.15
no.3
/
pp.259-261
/
2009
Sclerotinia shoot rot of Grapevine(Vitis labruscana) occurred at Gapyeong and Yeongwol area from 2003 to 2005. Infected plants showed shoot blight at the one-year-old fruit bearing branches. The first visible symptom noticed was wilting and blighting of the branches. The obvious and typical initial symptom is the presence of a cottony, white, dense mat of mycelial growth on the surface of the diseased lesions. The base or stem of the infected young shoots develop a pale brown rotted area, which girdled and killed shoots. In advanced stages of the disease, stems and branches became bleached and eventually died. The isolates collected from diseased grapevine stem were identified as Sclerotinia sclerotiorum based on the morphological and cultural characteristics. The pathogenicity test revealed that Vitis vinifera(cultivar: Kyoho) was stronger than V. labruscana(cultivar: Campbell early) to the pathogen. This is the first report on sclerotinia shoot rot of grapevine in Korea.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.