• 제목/요약/키워드: Massive concrete

검색결과 164건 처리시간 0.039초

매시브한 콘크리트에 매설된 철근의 Pull-out 거동 (The Experimental Study on Pull-out effct of Rebars embedded in Massive Concrete)

  • 천정희;선창호;김익현;이종석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.391-394
    • /
    • 2005
  • The seismic performance of bridge piers is evaluated in general by displacement terms, which are yielded not only by the member deformation but also by the pull-out of longitudinal bars embedded into foundation concrete. It is, therefore, important to understand the characteristic of pull-out effect in the view of seismic performance. In this study the specimens with different material strengths and diameters of re-bar were tested and the stree-slip were reported.

  • PDF

온도저감 공법을 고려한 콘크리트의 수화열 해석기법에 관한 연구 (Theraml Analysis of the Heat of Hydration in Concrete with Considering Heat Reduction Techniques)

  • 김진근;김국한;양주경
    • 콘크리트학회지
    • /
    • 제7권6호
    • /
    • pp.176-185
    • /
    • 1995
  • 매스콘크리트 구조물에서 시멘트의 수화발열반응에 발생된 열은 약재령 콘크리트에서 내부온도의 증가와 체적변화를 일으키게 된다. 이와 같은 온도증가에 외부구속조건이 존재하게 되면, 구조물에는 인장응력이 발생하고 이는 구조물에 균열을 일으킬 수 있다. 따라서 매스콘크리트 구조물 건설시 수화열에 의한 온도증가를 제어하기 위해 다양한 시공기법을 이용하고 있으며, 이들 공법 중 하나가 관에 냉각수를 유입시켜 온도를 하강시키는 파이프쿨링 공법이다. 이 논문의 목적은 파이프쿨링을 실시할 때 수화열로 인한 온도이력을 모사할 수 있는 유한요소해석 프로그램을 개발하는 것이다. 이 연구에서 개발된 해석 프로그램의 결과와 실제 구조물의 기초부(11$\times$22cm)의 실측 결과가 잘 일치함을 보였다. 따라서 여기서 제시된 방법은 파이프쿨링으로 인한 콘크리트의 수화온도 예측에 유용하게 이용될 수 있을 것으로 판단된다.

매스콘크리트구조물의 온도응력평가에 관한 연구 (A Study on the Evaluation of Thermal Stress of Massive Concrete Structure)

  • 강석화;정철헌;정한중;이용호;박칠림
    • 콘크리트학회지
    • /
    • 제7권2호
    • /
    • pp.126-135
    • /
    • 1995
  • 온도균열은 시멘트의 수화열에 의한 온도응력이 콘크리트의 인장강도보다 커질 경우에 발생하는 균열로서, 구조물의 수밀성과 기밀성등에 중대한 영향을 미치기 때문에 매스콘크리트와 같이 단면이 큰 구조물의 설계 및 시공시에는 반드시 온도균열에 대한 배려가 필요하다. 본 연구에서는 모의실험체를 대상으로 하여 매스콘크리트의 경화시 발생하는 온도응력을 측정할 목적으로 콘크리트변형계와 무응력계 그리고 유효응력계등을 설치하여구조물 내부의 온도응력의 경시변화를 검토하고 콘크리트변형계를 이용한 온도응력 산정방법 및 문제점등에 대하여 검토하였다. 연구결과 콘크리트변형계와 무응력계를 이용한 새로운 온도응력 산정법을 제시하였으며, 그 결과 유효응력계의 측정치와 거의 일치하는 값을 얻을 수 잇었다. 이를 위해서는 무응력계 또는 이와 동일하게 초기재령시의 콘크리트 자기수축변형률을 측정할 수 있는 게이지의 설치가 전제가 되어야 하며, 초기재령시의 건조수축량에 대한 정량화가 가능하다면 콘크리트변형계를 이용한 온도응력의 산정도 충분히 가능하다는 것을 알 수 있다.

LNG 저장탱크 벽체의 동절기 온도균열제어 방안 (The Method of Thermal Crack Control about the LNG Tank Wall in Winter)

  • 손영준;하재담;엄태선;이종열;백승준;박찬규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.637-640
    • /
    • 2008
  • 1998년 인천 LNG 인수기지에 국내 최초로 14만kl의 지하식 저장탱크가 건설되는 것을 시작으로 20만kl의 지하식 저장탱크가 연이어 건설되었다. 또한, 평택 및 통영 LNG 인수기지에 14만kl 및 20만kl의 지상식 저장탱크가 건설되고 있다. 저장탱크의 용량 및 방식에 따라 저장탱크의 설계단면이 변화하였으며, 콘크리트에 요구되는 특성 또한 변화하였다. 특히, 수화열에 의한 온도균열 발생 확률이 높은 Bottom 및 하부벽체는 4종 저열포틀랜드시멘트가 적용되고 있다. 20만kl 용량인 지상탱크 평택 16호기 상부벽체에 대한 동절기 온도균열제어를 위해 양생방법, 타설간격조절 및 배합변경에 따른 수화열 해석을 실시하였다. 기존 1종+FA25%인 배합을 적용시 목표균열지수를 만족하기 위해서는 보온양생 및 타설간격 증가 등 시공적 대책이 필요하며, 배합을 4종+FA15%로 변경시에는 추가적인 시공대책 없이 온도균열 제어가 가능한 것으로 나타났다.

  • PDF

A Study on the Optimum Mix Proportion of the Mass Concrete Designed as Massive and Deep Structure

  • Kwon Yeong-Ho;Lee Hwa-Jin
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.293-302
    • /
    • 2005
  • This study describes data from determination of the optimum mix proportion and site application of the mass concrete placed in bottom slab and side wall having a large depth and section as main structures of LNG in-ground tank. This concrete requires low heat hydration, excellent balance between workability and consistency because concreting work of LNG in-ground tank is usually classified by under-pumping, adaptation of longer vertical and horizontal pumping line than ordinary pumping condition. For this purpose, low heat Portland cement and lime stone powder as cementitious materials are selected and design factors including unit cement and water content, water-binder ratio, fine aggregate ratio and adiabatic temperature rising are tested in the laboratory and batch plant. As experimental results, the optimum unit cement and water content are selected under $270kg/m^3$ and $l55{\~}l60 kg/m^3$ separately to control adiabatic temperature rising below $30^{\circ}C$ and to improve properties of the fresh and hardened concrete. Also, considering test results of the confined water ratio($\beta$p) and deformable coefficient(Ep), $30\%$ of lime stone powder by cement weight is selected as the optimum replacement ratio. After mix proportions of 5cases are tested and compared the adiabatic temperature rising($Q^{\infty}$, r), tensile and compressive strength, modulus of elasticity, teases satisfied with the required performances are chosen as the optimum mix design proportions of the side wall and bottom slab concrete. $Q^{\infty}$ and r are proved smaller than those of another project. Before application in the site, properties of the fresh concrete and actual mixing time by its ampere load are checked in the batch plant. Based on the results of this study, the optimum mix proportions of the massive concrete are applied successfully to the bottom slab and side wall in LNG in-ground tank.

CFT구조용 초고강도 콘크리트의 현장 적용을 위한 실험적 연구 (An Experimental Study on High Strength Concrete for Concrete Filled Steel Tube Column for Field Application)

  • 이장환;김영주;정광식;강태경;정근호;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.454-457
    • /
    • 2004
  • Due to social problems such as the increasing of land price and the expanding of city, buildings require more complex and bigger components and structure. However, the complex and massive building projects need new technology to solve effect of local buckling and the needs for more space. Hence, Concrete Filled Tube Steel (CFT), the tube steel to hold concrete during pouring and curing of concrete procedure, which helps to reduce local buckling and space, was developed. Most researches on CFT might not be focused on the characteristic of concrete 'filled in tube but structural analysis. However, it is the essential factor to increase the strength of concrete on CFT for having efficient results. Therefore, this paper will describe how to apply CFT into the construction site through examining High Strength Concrete $(800kg/cm^2)$, the strength of core, and bleeding during pouring strategy.

  • PDF

수중불분리성 콘크리트 중의 철근부식 평가 (Estimation on Corrosion of Reinforcing bar in Antiwashout Underwater Concrete)

  • 문한영;김성수;김홍삼;김종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.447-450
    • /
    • 2000
  • Recently, antiwashout underwater concrete has used for underwater structure such as high strength massive concrete structures. When, concrete is placed in seawater the quality and durability of concrete could be doubt to especcially because the amount of cement placed in the concrete can be diminished by flowing seawater. In this study, antiwashout underwater concrete mixed with mineral admixtures for improvement of properties was placed in air, water, and salt water. Half-cell potential and current density was of specimens which made under different conditions measured for estimating corrosion degree. The experimental results demostrate that corrosion resistantce in saltwater was little and mineral admixtures improved properties of concrete.

  • PDF

우성 캐릭터 199에 고강도 콘크리트 적용에 관한 연구 (The Application of High Strength Concrete on Woo-Sung Character 199 Project)

  • 신성우;안종문;김원섭;김세현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.357-362
    • /
    • 1996
  • The objective of this study is to investigate material properties and quality control of cast-in-place high strength concrete. High strength concrete with a design strength of 420 kgf/$\textrm{cm}^2$ is successfully produced at a ready-mixed concrete plant, and placed at a tall building. Many laboratory and field tests are carried out for the successful construction of the reinforced high strength concrete building. As the results of this study, the average actual 28-day compressive strength is 513 kgf/$\textrm{cm}^2$ and the coefficient of variation is 6.8%. The placing speed is comparable to normal strength concrete, however, the pump pressure is higher than that of normal strength concrete. To prevent cracks of massive and long concrete members, the control of hydration heat and shrinkage is very important.

  • PDF

국내 시방서와 ACI 규준 열전달율이 매스콘크리트 온도이력에 미치는 영향 (Effects of Thermal Conductivities on Temperature History of Massive Concrete Structures)

  • 장동일;손영현;조광현;김광일
    • 한국안전학회지
    • /
    • 제14권2호
    • /
    • pp.122-126
    • /
    • 1999
  • In this study, using the temperature history analysis, the influences of the conductive values of wooden form, which are specified by Korean Standard for Concrete and ACI Practice Manual for Concrete, on the temperature history were examined. And, the calculated temperature history is compared with the measured temperature history. In the examination for the influences of the conductive values of wooden form, the value recommended by the Korean Standard can more closely predict the themperature history at the points which the variation of the boundary condition should be considered.

  • PDF

기초매트 매스콘크리트의 수화열 균열제어로서 초지연콘크리트 활용에 관한 Mock-up 실험 (Mock-up Test of Improving Super Retarding Concrete to Control of Hydration Heat Crack of Foundation Mat Mass Concrete)

  • 이재삼;배연기;노상균;김석일;정성진;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.777-780
    • /
    • 2008
  • 최근 도심지에는 건축물이 점차 초고층화하는 경향에 따라 매우 두꺼운 매스콘크리트가 건축물의 기초로 채택되어 진다. 그런데, 이와 같은 매스콘크리트는 현장여건상 다량의 콘크리트를 동시에 타설할 수 없기 때문에 상 하층 타설 콘크리트간의 일체성에 의문이 제기되는 것은 물론이고 수화발열시 간의 상위에 따른 내응력에 의한 균열이 발생하여 문제점으로 지적되고 있다. 따라서 본 연구에서는 매트콘크리트의 상 하층 수화발열시간의 상위에 따른 내응력에 의한 균열에 대한 안전성을 확보하기 위한 목적으로 초지연제의 응결시간차를 활용한 수평분할타설 건축 매스콘크리트의 수화열 조정공법을 건축현장에 적용하고자 Mock-up test를 통하여 그 효율성을 확인하였다. 실험결과 2단 및 4단으로 초지연제에 의한 응결시간차공법을 활용한 경우 하부와 상부간의 온도차를 낮추고, 수화열 피크시점이 후기로 늦어짐에 따라 균열발생가능성을 저하시키는 효과를 확인할 수 있었다.

  • PDF