• Title/Summary/Keyword: Mass energy

Search Result 3,841, Processing Time 0.024 seconds

Model-based localization and mass-estimation methodology of metallic loose parts

  • Moon, Seongin;Han, Seongjin;Kang, To;Han, Soonwoo;Kim, Munsung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.846-855
    • /
    • 2020
  • A loose part monitoring system is used to detect unexpected loose parts in a reactor coolant system in a nuclear power plant. It is still necessary to develop a new methodology for the localization and mass estimation of loose parts owing to the high estimation error of conventional methods. In addition, model-based diagnostics recently emphasized the importance of a model describing the behavior of a mechanical system or component. The purpose of this study is to propose a new localization and mass-estimation method based on finite element analysis (FEA) and optimization technique. First, an FEA model to simulate the propagation behavior of the bending wave generated by a metal sphere impact is validated by performing an impact test and a corresponding FEA and optimization for a downsized steam-generator structure. Second, a novel methodology based on FEA and optimization technique was proposed to estimate the impact location and mass of a loose part at the same time. The usefulness of the methodology was then validated through a series of FEAs and some blind tests. A new feature vector, the cross-correlation function, was also proposed to predict the impact location and mass of a loose part, and its usefulness was then validated. It is expected that the proposed methodology can be utilized in model-based diagnostics for the estimation of impact parameters such as the mass, velocity, and impact location of a loose part. In addition, the FEA-based model can be used to optimize the sensor position to improve the collected data quality in the site of nuclear power plants.

Efficient Energy Management for Pyro-processing of Solids - (1) Heat & Mass Balance and Evaluation (고체 고온공정에서 효율적 에너지 관리 - (1) 공정 열정산 및 평가 방법)

  • Ha, Daeseung;Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.1
    • /
    • pp.18-30
    • /
    • 2016
  • Pyro-process of solids is the way to heat solid materials under high temperature. In this processing, energy efficient use is one of the main concerns due to its high energy consumption of bulk materials. To calculate the energy use of processes, heat & mass balance in simplified 0-dimensional model was performed. Energy calculation by this simplified model can lead to confusion due to simplification. Thus, it is necessary to understand considerations of energy analysis. In this study, cement manufacturing as a very common example of pyro-processing of solids, was introduced for explaining considerations of energy analysis for energy efficient use.

A Longitudinal Study on Seasonal Variations of Physical Activity and Body Composition of Rural Women (농촌여성들의 계절별 활동량과 체성분 차이에 관한 종단 연구)

  • 임화재
    • Journal of Nutrition and Health
    • /
    • v.28 no.9
    • /
    • pp.893-903
    • /
    • 1995
  • This study was attempted to estimate seasonal variations of physical activity level, energy balance & body composition of 38 rural women, aged 31 to 67yrs in three seasons ; farming season(June), harvesting season(October), nonfarming season(February) Energy intake, energy expenditure and body composition were assessed using questionnaire, daily activity diary & bioelectrical impedance. The type of activities & the period of the spent on each activity were changed significantly with the seasons. Daily mean duration(min) of farming activity was significantly higher in June & October than in February(p<0.005) & daily mean energy expenditure for farming activity was significantly high in June & low inFebruary (p<0.005). Daily mean energy expenditure was 2892.9㎉ in June, 2487.4㎉ in October and 2130.9㎉ in February and changed significantly in three seasons(p<0.005). Daily mean energy intake was significantly higher in June(=1950.3㎉) & October (=1946.9㎉) than in February(=1423.3㎉)(p<0.005). According to RDA for koreans, the level of physical activity fell into exceptional activity category in June, heavy in October, moderate in February. Mean energy balance was negative in all seasons ; 0.682 in June, 0.812 in October and 0.698 in February. In three seasons mean body weight, mean obesity rate and mean body mass index(BMI) were not changed significantly. But there were significant seasonal variations in body fat(%) & lean body mass(LBM)(%). The mean percentage of body fat(%) was within normal range(24.44-24.79%) & the mean percentage of lean body mass(LBM)(%) representing long term physical activity was significantly higher in June(75.56%) & October(75.21%) & October (75.21%) than in February(72.75%)(p<0.05).

  • PDF

The Development of Momentum Conversion Type Micro Punch System using Elastic Collision (탄성충돌을 이용한 운동량 보존형 마이크로 펀치 시스템의 개발)

  • 장인배;장현철;최근형;김병희;김현영
    • Transactions of Materials Processing
    • /
    • v.12 no.2
    • /
    • pp.128-133
    • /
    • 2003
  • In this study, the momentum conservation type punching mechanism for micropunching system was developed to avoid the punch failure in the misaligned status between the punch and die. The punching energy can be precisely controlled by the falling height of the projectile mass and the intermediata mass, which contacts with the punch, transmit the energy to the punch with the same contact condition. The potential energy of the projectile mass is converted to kinetic energy at the light weight punch that the projection speed into the sheet metal workpiece can be accelerated. The butt formation characteristics for the alignment condition and for the projection speeds are investigated to verify the feasibility of the proposed punching mechanism.

Isotopic Analysis of NUSIMEP-6 Uranium Particles using SEM-TIMS

  • Park, Jong-Ho;Park, Sujin;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.51-54
    • /
    • 2013
  • Isotopic analysis using thermal ionization mass spectrometry coupled with scanning electron microscopy (SEM-TIMS) was performed to determine the isotopic ratios of uranium contained in micro-particles in the 6th Nuclear Signatures Interlaboratory Measurement Evaluation Programme (NUSIMEP-6) sample. Elemental analysis by energy dispersive X-ray spectroscopy (EDS) was conducted on uranium-bearing mirco-particles, which were transferred to rhenium filaments for TIMS loading using a micromanipulation system in a SEM. A multi-ion-counter system was utilized to detect the ion signals of the four isotopes of uranium simultaneously. The isotope ratios of uranium corrected by bracketing using a reference material showed excellent agreement with the certified values. The measurement accuracy for $n(^{234}U)/n(^{238}U)$ and (b) $n(^{235}U)/n(^{238}U)$ was 10% and 1%, respectively, which met the requirements for qalification for the NetWork of Analytical Laboratories (NWAL).

Effects of Body Build on Metabolic and Physiological Function in Men and Athletes - 1. Especially on the Metabolic Function -

  • Lee, Ok-Hee;Lim, Soon-Gill;Lee, Jung-Hee
    • Nutritional Sciences
    • /
    • v.2 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • The aim of this study was to investigate influence of body build on body composition, energy metabolic state and insulin concentration of blood. 29 male athletes and 36 male non-athletic students were recruited for the study. Anthropometry including chest depth and breadth, fat mass, fat fee mass, tricep skinfold thickness were measured. fasting glucose, lactate, triglyceride, fee fatty acid, and insulin concentration in serum were measured . Body build was assessed using metric index, which calculated by regression equations of Mohr and Greil. The athletic and non-athletic students were allocated to 3 body build, that is leptomorph, mesomorph, and pyknomorph. Resting metabolic rate was calculated. Respiratory quotient was determined through ratio of measured VO$_2$, and V$CO_2$. Most non-athletes have a leptomorphic body build, in contrast to athletes mesomorphic type. The body build type influenced body composition differently between non-athletic group and athletic group. Weight, body mass index, body fat mass and fat mass proportion (%), and fat-free mass increased from leptomorph to pyknormorph in non-athletic group. Pyknormorphic athletes have a significant higher body mass index, fat mass, fat free mass than other body build type. Serum glucose, triglyceride, lactate, insulin showed significant differences only in non-athletic group between leptomorph and mesomorph. RMR increased significantly from leptomorph to mesomorph in non-athletes. There was no significant difference of RQ among 3 body build types in both athletes and non-athletes. This study gives a coherent data on body build and body composition for athletes and non-athletes students. The influence of body builds on energy metabolic status of serum was different between athletes and non-athletes.

  • PDF

The Level of Serum Cholesterol is Negatively Associated with Lean Body Mass in Korean non-Diabetic Cancer Patients

  • Han, Ji Eun;Lee, Jun Yeup;Bu, So Young
    • Clinical Nutrition Research
    • /
    • v.5 no.2
    • /
    • pp.126-136
    • /
    • 2016
  • Due to poor nutrition and abnormal energy metabolism, cancer patients typically experience the loss of muscle mass. Although the diabetic conditions or dyslipidemia have been reported as a causal link of cancer but the consequence of such conditions in relation to gain or loss of skeletal muscle mass in cancer patients has not been well documented. The purpose of this study was to investigate the relationship of lean body mass and systemic parameters related to lipid metabolism in non-diabetic cancer patients using data from the Korean National Health and Nutrition Examination Survey (KNHANES) 2008-2011. As results the level of serum total cholesterol (total-C) was negatively associated with both total lean body mass and appendicular lean body mass in cancer patients after adjustment for sex, physical activity, energy intake and comorbidity. The associations between consumption of dietary factors (energy, carbohydrate, protein and fat) and lean body mass were disappeared after adjusting comorbidities of cancer patients. Multivariate-adjusted linear regression analysis by quartiles of serum total-C showed that higher quartile group of total-C had significantly lower percent of lean body mass than reference group in cancer patients. The data indicate that serum lipid status can be the potential estimate of loss of skeletal muscle mass in cancer patients and be referenced in nutrition care of cancer patients under the onset of cachexia or parenteral/enteral nutrition. This data need to be confirmed with large pool of subjects and should be specified by stage of cancer or the site of cancer in future studies.

Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF

The study of simplified technique compared with analytical solution method for calculating the energy consumption loads of four houses having various wall construction

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.1
    • /
    • pp.46-58
    • /
    • 2011
  • A steady-state analysis and a simple dynamic model as simplified methods are developed, and results of energy consumption loads are compared with results obtained using computer to evaluate the analytical solution. Before obtaining simplified model a mathematical model is formulated for the effect of wall mass on the thermal performance of four different houses having various wall construction. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one-dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures is obtained using the Laplace transform method. Typical Meteorological Year data are processed to yield hourly average monthly values. This study is conducted using weather data from four different locations in the United States: Albuquerque, New mexico; Miami, Florida; Santa Maria, California; and Washington D.C. for both winter and summer conditions. The steady state analysis that does not include the effect of thermal mass can provide an accurate estimate of energy consumption in most cases except for houses #2 and #4 in mild weather areas. This result shows that there is an effect of mass on the thermal performance of heavily constructed house in mild weather conditions. The simple dynamic model is applicable for high cycling rates and accurate values of inside wall temperature and ambient air temperature.