• Title/Summary/Keyword: Mass contribution

Search Result 341, Processing Time 0.025 seconds

Effect of Lipid Mediated Glucose-Protein Reaction on Thermal Flayer Generation (당-단백질 가열반응 시에 생성되는 향기성분에 미치는 지질의 영향)

  • 주광지
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • The contribution of lipid to thermal flayer generation from glucose-protein reaction was accomplished by isolating flavor compounds from casein-glucose (CG)and casein-glucose-coin oil (CGL) which were stored for 2 and 4 weeks at 6$0^{\circ}C$ and then reacted at 16$0^{\circ}C$ for 1hr. The volatiles from the reactant mixtures were isolated by a solvent extraction method with methylene chloride and analyzed by gas chromatography and gas chromatography-mass spectrometry. Pyrazine, methylpyrazine, 2,5-dimethylpyrazine, 2-dimethylpyrazine ,2-ethy-5- methyIpyrazine and 2-acetylpyrrole originated from interaction of thermal degradation of casein and lipid oxidation were identified in the CGL samples. It was also found that 3-methyl-1-butanol, 2-cyclopene-1,4-diode, heptanal, nonanal, and 2-heptanone were derived from lipid source. Two additional fatty acids, heptanoic acid and octanoic acid were also identified in the CGL samples. 5-Hydroxymethyl-2-furfural, the most abundant volatile, was responsible for the formation of sugar degradation product. The results suggested that the presence of lipid in the samples had more effect on the contribution of volatile formation of glucose-protein thermal reaction than the absence of lipid in the samples.

Estimation of Uncertainty in Critical Flow Function for Natural Gas (천연가스의 임계유동함수 불확도 평가)

  • Ha, Young-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.625-638
    • /
    • 2014
  • In this study, the uncertainties in the critical flow functions (CFFs) calculated by the AGA8-dc equation of state were estimated. To this end, the formulas for enthalpy, entropy, and speed of sound, which are used in calculating the CFF, were expressed in the form of dimensionless Helmholtz free energy and its derivatives, and the uncertainty in Helmholtz free energy was inferred. To consider the variations in the compressibility-dependent variables induced by the variation (i.e., uncertainty) in compressibility, the form of the AGA8-dc equation was modified to have a deviation equal to the uncertainty under each flow condition. For each independent uncertainty component of the CFF, a model for uncertainty contribution was developed. All these changes were applied to GASSOLVER, which is KOGAS's thermodynamic database. As a result, the uncertainties in the CFF were estimated to be 0.025, 0.055, and 0.112 % at 10, 50, and 100 bar, respectively, and are seen to increase with the increase in pressure. Furthermore, these results could explain the deviations in the CFFs across the different labs in which the CFF international comparison test was conducted under the ISO management in 1999.

The Study on the Comparison of the ISCST3 Model and Receptor Model by Dispersion Tracing of Particulate Matter from Large Scale Pollution Sources (대단위배출원에서 기인한 입자상오염물질의 확산ㆍ추적을 통한 ISCST3모델과 수용모델의 비교연구)

  • 전상기;이성철;박경선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.789-803
    • /
    • 2003
  • The purpose of this study is to compare the usefulness between Gaussian dispersion model and receptor model with the experimental result of the dispersion tracing of the particulate pollutants from Taean coal-fired power plants. For this purpose, the component analysis of the collected PM 10 samples was performed. In order to trace the pollution sources, factor analysis was done with the result of the component analysis. As a result of the correlativity analysis of the fifteen power plants' profiles offered by US EPA, the correlativity of No.11202 source profile showed highest rate up to 84.5%. Thus it was adopted as proper one and the contribution rate by each pollution source was calculated by Chemical Mass Balance (CMB)-8 model. The contribution rate, which was the effect rate of the power plants on each measuring point, were calculated with a range of 24∼52% and the standard error was below 0.9 $\mu\textrm{g}$/㎥. This indicates the selection of the source profile was appropriate. Also, the concentrations of each point were calculated by the ISCST3 which is suggested by US EPA as one of the regulatory Gaussian dispersion model. The calculation result showed that the predicted concentration was 50∼58 $\mu\textrm{g}$/㎥, comparing with the measured result of 9∼65 $\mu\textrm{g}$/㎥. It was found that the concentration calculated by ISCST3 was underpredicted. It was thought that the receptor model was more favorable than the Gaussian dispersion model in estimating the effect of the particulate matter on a certain receptive point.

Estimation of Quantitative Source Contribution of Ambient PM-10 Using the PMF Model (PMF모델을 이용한 대기 중 PM-10 오염원의 정량적 기여도 추정)

  • 황인조;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.719-731
    • /
    • 2003
  • In order to maintain and manage ambient air quality, it is necessary to identify sources and to apportion its sources for ambient particulate matters. The receptor methods were one of the statistical methods to achieve reasonable air pollution strategies. Also, receptor methods, a field of chemometrics, is based on manifold applied statistics and is a statistical methodology that analyzes the physicochemical properties of gaseous and particulate pollutant on various atmospheric receptors, identifies the sources of air pollutants, and quantifies the apportionment of the sources to the receptors. The objective of this study was 1) after obtaining results from the PMF modeling, the existing sources of air at the study area were qualitatively identified and the contributions of each source were quantitatively estimated as well. 2) finally efficient air pollution management and control strategies of each source were suggested. The PMF model was intensively applied to estimate the quantitative contribution of air pollution sources based on the chemical information (128 samples and 25 chemical species). Through a case study of the PMF modeling for the PM-10 aerosols, the total of 11 factors were determined. The multiple linear regression analysis between the observed PM-10 mass concentration and the estimated G matrix had been performed following the FPEAK test. Finally the regression analysis provided quantitative source contributions (scaled G matrix) and source profiles (scaled F matrix). The results of the PMF modeling showed that the sources were apportioned by secondary aerosol related source 28.8 %, soil related source 16.8%, waste incineration source 11.5%, field burning source 11.0%, fossil fuel combustion source 10%, industry related source 8.3%, motor vehicle source 7.9%, oil/coal combustion source 4.4%, non-ferrous metal source 0.3%. and aged sea- salt source 0.2%, respectively.

Spectro-electrochemical Analyses of Immobilization of Glucose Oxidase (Glucose Oxidase 고정화에 대한 전기화학적/광학적 분석)

  • Kim, Hyun-Cheol;Cho, Young-Jai;Gu, Hal-Bon;SaGon, Geon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.316-319
    • /
    • 2000
  • In the case of immobilizing of glucose oxidase into polypyrrole (PPy) using electrosynthesis, the glucose oxidase (GOx) forms a coordinate bond with the polymer's backbone. However, because of intrinsic insulation and net-chain of the enzyme, the charge transfer and mass transport are obstructed during the film growth. Therefore, the film growth is dull. We synthesized the enzyme electrode by electropolymerization added some organic solvent, A formative seeds of film growth is delayed by adding the solvent. The delay is induced by radical transfer between the solvent and pyrrole monomer. In the case of adding ethanol, the radical transfer shares the contribution of dopant between electrolyte anion and GOx polyanion. This may lead to increase amount of immobilized the enzyme in ppy. However, adding tetrahydrofuran (THF), the radical transfer is more brisk, resulting in short chained polymer. Therefore, the doping level is lowered and then amount of immobilized of enzyme is decreased. For the UV absorption spectra of synthetic solution before synthesis and after, in the case of ethanol added, the optical density was slightly decreased for the GOx peaks. It suggests amount of GOx in the solution was decreased and amount of GOx in the film was increased. We established qualitatively that amount of immobilization can be improved by adding a little ethanol in the synthetic solution. It is due to radical transfer reaction. The radical transfer shares the contribution of dopant between small and fast electrolyte anion and big and slow GOx polyanion.

  • PDF

The influence of cuttlebone on the target strength of live golden cuttlefish (Sepia esculenta) at 70 and 120 kHz

  • Lee, Daejae
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.2
    • /
    • pp.8.1-8.11
    • /
    • 2016
  • To quantitatively estimate the influence of cuttlebone on the target strength (TS) of golden cuttlefish, the cuttlebone was carefully extracted from 19 live cuttlefish caught using traps in the inshore waters around Geojedo, Korea, in early May 2010 and the TS was measured using split-beam echosounders (Simrad ES60 and EY500). The TS-length relationships for the cuttlefish (before the extraction of cuttlebone, Fish Aquat Sci. 17:361-7, 2014) and the corresponding cuttlebone were compared. The cuttlebone length ($L_b$) ranged from 151 to 195 mm (mean $L_b$ = 168.3 mm) and the mass ($W_b$) ranged from 29.3 to 53.2 g (mean $W_b$ = 38.8 g). The mean TS values at 70 and 120 kHz were -33.60 dB (std = 1.12 dB) and -32.24 dB (std = 1.87 dB), respectively. The mean TS values of cuttlebone were 0.19 dB and 0.04 dB lower than those of cuttlefish at 70 and 120 kHz, respectively. For 70 and 120 kHz combined, the mean TS value of cuttlebone was -32.87 dB, 0.11 dB lower than that of cuttlefish (-32.76 dB). On the other hand, the mean TS value of cuttlebone predicted by the regression ($TS_b$ = 24.86 $log_{10}$ $L_b$ - 4.86 $log_{10}$ ${\lambda}$ - 22.58, $r^2$ = 0.85, N = 38, P < 0.01) was -33.10 dB, 0.04 dB lower than that of cuttlefish predicted by the regression ($TS_c$ = 24.62 $log_{10}$ $L_c$ - 4.62 $log_{10}$ ${\lambda}$ - 22.64, $r^2$ = 0.85, N = 38, P < 0.01). That is, the contribution of cuttlebone to the cuttlefish TS determined by the measured results was slightly greater than that by the predicted results. These results suggest that cuttlebone is responsible for the TS of cuttlefish, and the contribution is estimated to be at least 99 % of the total echo strength.

Seismic response of steel reinforced concrete frame-bent plant of CAP1400 nuclear power plant considering the high-mode vibration

  • Biao Liu;Zhengzhong Wang;Bo Zhang;Ningjun Du;Mingxia Gao;Guoliang Bai
    • Steel and Composite Structures
    • /
    • v.46 no.2
    • /
    • pp.221-236
    • /
    • 2023
  • In order to study the seismic response of the main plant of steel reinforced concrete (SRC) structure of the CAP1400 nuclear power plant under the influence of different high-mode vibration, the 1/7 model structure was manufactured and its dynamic characteristics was tested. Secondly, the finite element model of SRC frame-bent structure was established, the seismic response was analyzed by mode-superposition response spectrum method. Taking the combination result of the 500 vibration modes as the standard, the error of the base reactions, inter-story drift, bending moment and shear of different modes were calculated. Then, based on the results, the influence of high-mode vibration on the seismic response of the SRC frame-bent structure of the main plant was analyzed. The results show that when the 34 vibration modes were intercepted, the mass participation coefficient of the vertical and horizontal vibration mode was above 90%, which can meet the requirements of design code. There is a large error between the seismic response calculated by the 34 and 500 vibration modes, and the error decreases as the number of modes increases. When 60 modes were selected, the error can be reduced to about 1%. The error of the maximum bottom moment of the bottom column appeared in the position of the bent column. Finally, according to the characteristics of the seismic influence coefficient αj of each mode, the mode contribution coefficient γj•Xji was defined to reflect the contribution of each mode to the seismic action.

Investigation of PM2.5 Pollution Episodes in Gwangju (광주지역 PM2.5의 고농도 오염현상 조사)

  • Yu, Geun-Hye;Cho, Sung-Yong;Bae, Min-Suk;Lee, Kwon-Ho;Park, Seung-Shik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.3
    • /
    • pp.269-286
    • /
    • 2015
  • 24-hr integrated $PM_{2.5}$ measurements were performed between December 2013 and October 2014 at an urban site in Gwangju and the collected samples were analyzed for organic carbon (OC), elemental carbon (EC), ionic species, and elemental species. Objectives of this study were to identify $PM_{2.5}$ pollution episodes, to characterize their chemical components, and to examine their probable origins. Over the course of the study period, average $PM_{2.5}$ concentration was $37.7{\pm}23.6$ $(6.0{\sim}121.5){\mu}g/m^3$. Concentrations of secondary ionic species; $NH_4{^+}$, $NO_3{^-}$, and $SO_4{^{2-}}$ was on average $5.54{\mu}g/m^3$ (0.28~ 20.86), $7.60{\mu}g/m^3$ (0.45~ 33.53), and $9.05{\mu}g/m^3$ (0.50~ 34.98), accounting for 13.7% (4.6~ 22.7), 18.6% (2.9~ 44.8), and 22.9% (4.9~ 55.1) of the $PM_{2.5}$ concentration, respectively. Average OC and EC concentrations were $5.22{\mu}g/m^3$ and $1.54{\mu}g/m^3$, taking possession of 4.6 and 22.2% (as organic mass) of the $PM_{2.5}$, respectively. Frequencies at which 24-hr averaged $PM_{2.5}$ exceeded a 24-hr averaged Korean $PM_{2.5}$ standard of $50{\mu}g/m^3$ (termed as an "episode" in this study) were 30, accounting for 21.3% of total 141 measurements. These pollution episodes were mostly associated with haze phenomenon and weak surface wind speed. It is suggested that secondary formation of aerosol was one important formation mechanism of the episodes. The episodes were associated with enhancements of organic mass, $NO_3{^-}$ and $SO_4{^{2-}}$ in winter, of $NO_3{^-}$ and $SO_4{^{2-}}$ in spring, and of $SO_4{^{2-}}$ in summer. Potential source contribution function results indicate also that $PM_{2.5}$ episodes were likely attributed to local and regional haze pollution transported from northeastern China in winter, to atmospheric processing of local emissions rather than long-range transport of air pollutants in spring, and to the $SO_4{^{2-}}$ driven by photochemistry of $SO_2$ in summer.

Chemical Composition of Fine Particulate Matter in the Downtown Area of Jeju City (제주시 도심지역 미세먼지의 화학적 조성 특성)

  • Hu, Chul-Goo;Lee, Ki-Ho
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.597-610
    • /
    • 2018
  • This study observed particulate matter ($PM_{2.5}$ and $PM_{10}$) in the downtown area of Jeju City, South Korea, to understand the chemical composition of particulates based on an analysis of the water-soluble ionic species contained in the particles. The mass fraction of the ionic species in the sampled $PM_{10}$ and $PM_{2.5}$ was 44.3% and 42.2%, respectively. In contrast, in Daegu City and Suwon City, the mass fraction of the ionic species in $PM_{2.5}$ was higher than that in $PM_{10}$. The chloride depletion percentage of $PM_{10}$ and $PM_{2.5}$ in Jeju City was higher than 61% and 66%, respectively. The contribution of sea-salt to the mass of $PM_{10}$ (5.9%) and $PM_{2.5}$ (2.6%) in Jeju City was similar to that in several coastal regions of South Korea. The mass ratio of $Cl^-$ to $Na^+$ in the downtown area of Jeju City was comparable to that in some coastal regions, such as the Gosan Area of Jeju Island, Deokjeok Island, and Taean City. The mass fraction of sea-salt in $PM_{10}$ and $PM_{2.5}$ was very low, and the concentration of sodium and chloride ions in $PM_{10}$ was not correlated with those in $PM_{2.5}$ ($R^2$ < 0.2), suggesting that the effects of sea-salt on the formation of particulate matter in Jeju City might be insignificant. The relationship between $NH_4{^+}$ and several anions such as $SO_4{^{2-}}$, $NO_3{^-}$, and $Cl^-$, as well as the relationship between the measurement and calculation of ammonium ion concentration, suggested that sea-salts may not react with $H_2SO_4$, and $(NH_4)_2SO_4$ may be a major secondary inorganic aerosol component of $PM_{2.5}$ and $PM_{10}$ in Jeju City.

Spatial distribution of heterotrophic bacteria and the role of microbial food web in the northern East China Sea in summer (하계 동중국해 북부해역에서 종속영양박테리아의 분포 특성 및 미생물 먹이망의 역할)

  • Bomina Kim;Seok-Hyun Youn
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.1
    • /
    • pp.89-100
    • /
    • 2023
  • We investigated the spatial distribution of heterotrophic bacteria associated with different water masses in the northern East China Sea(ECS) in summer. The surface water masses were divided into the Changjiang Diluted Water (CDW) and high salinity water (HSW). In the CDW region, the concentrations of dissolved inorganic nitrogen (DIN) and chlorophyll-a (Chl-a), and micro Chl-a contribution were high; and bacterial abundance (BA) and ciliate abundance (CA) were also high. In the HSW region with relatively low DIN concentrations, Chl-a concentration and micro Chl-a contribution were low, but pico Chl-a contribution was increased compared to those in the CDW region. BA did not show any significant difference from the CDW region, but CA was decreased. BA showed a positive correlation with Chl-a concentration in the CDW region; however, it did not show a significant correlation with Chl-a concentration in the HSW region. The ratio of bacterial carbon biomass/phytoplankton carbon biomass was exponentially increased with a decrease in the Chl-a concentration. Compared to the past (1990-2000s), the surface phosphate concentrations and the size of dominant phytoplankton have recently decreased in the ECS. Considering this trend of nutrient decrease and miniaturization of the phytoplankton, our results indicate that changes in the strength of the oligotrophic water mass could alter the function of the microbial food web.