• Title/Summary/Keyword: Mass changes

Search Result 2,181, Processing Time 0.031 seconds

Radio-Carbon Age Determination by Tandem Accelerator Mass Spectrometry Technique and Its Application To The Korean Sea (탄뎀가속기에 의한 방사성탄소 년대측정과 한국해에의 적용)

  • Suk, Bong-Chool;Toshio Nakamura;Nobuyuki Nakai;Asahiko Taira
    • The Korean Journal of Quaternary Research
    • /
    • v.4 no.1
    • /
    • pp.27-40
    • /
    • 1990
  • $^{14}C$ age dating by AMS (accelerator mass spectrometry) technique was performed on twenty five small sized fossil shells and one peat taken from the sixteen piston cores in the southern and southeastern Korean Sea. AMS technique is available to date only a few milligram of amorphous carbons compare than conventional dating technique. It is described in detail of sample pre-treatment and experimental, and applied to the reconstruction of the sea level changes since the late Pleistocene in the Korean Sea. Dated age ranges from 520$\pm$100 to older than 33,500 years. Sedimentary facies in the study area represents a different environmental set which is affected by sea level fluctuation since the late Pleistocene.

  • PDF

Evaluation of Clinical Image on Observational Condition in Mammography (유방촬영시 관찰조건에 따른 임상영상평가)

  • Kim, Mi-Hyun;Kim, Chang-Bok;Ji, Youn-Sang;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.89-95
    • /
    • 2010
  • High contrast and high resolution are the most important factors for examining mammography images. Despite of the inconveniences of screen-film, most clinics still prefer them to computed radiography(CR) and direct radiography(DR). The reading of screen-film mammography images is influenced by the brightness from the X-ray illuminator, the exam room and incoming light from outside sources. Therefore, a comparative analysis on the results of mammo phantom images would be variated by the changes in the reading environment. There was no influence on reading results from the examiners close distance eyesight(p > 0.05); however, reading of micro lesions improved with greater darkness in the X-ray film reading room and the brightness of the X-ray illuminator(p < 0.05). Also, observation of fiber and mass images were maximized at a distance of 50 cm from the reader. Now, it is possible to observe these small classification groups using a magnifying glass without being physically close to the image. For the image of mammography, obtaining high quality images is important but in order to get an accurate clinical lesions of the reading also needs to be considered the optimal environmental factors.

  • PDF

Cutaneous Lipomatous Neurofibroma on the Lower Leg : A Case Report (하지에 발생한 피부 지방종성 신경섬유종의 치험례)

  • Yoon, Suk Ho;Jung, Sung-No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.500-502
    • /
    • 2009
  • Purpose: Cutaneous lipomatous neurofibroma is a rare variant of neurofibroma. Histologically, it includes adipose tissue. As far as we aware, only 11 cases of this variant were reported which was predominantly on head, neck and trunk, so we present a case of left pretibial area with literature review. Method: A 17 - year old female who showed a non - tender, protruding $4{\times}4{\times}2cm$ sized mass on the left pretibial area for several months. We totally excised the mass including skin and the subcutaneous fat layer. Results: Pathologic report showed cutaneous lipomatous neurofibroma which was well circumscribed and noncapsulated neoplasm present with focal fatty change. Adipose cells were entrapped in the whirls of spindle cells. There were no lipoblasts or atypical adipocytes. Conclusion: A cutaneous lipomatous neurofibroma on the lower extremity is very rare. In our patient, there were no trauma - related histopathologic changes. Therefore, focal fatty change can be a consequence of metaplasia from multipotential neural cells after migration.

The Effect of 8 Weeks Athletics Class on Sprint Start Motion (8주 동안의 육상 교양수업 참여가 단거리 스타트 동작에 미치는 영향)

  • Lee, Jin-Taek
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.209-216
    • /
    • 2014
  • The purpose of this study was to explore the effect of 8 weeks after school classes of track sports on students' start motion through kinematic variables. 30 students in D National university of education participated for this study. These students divided into two groups, 17 students for experimental group and 13 students for control group. The two groups participated in general athletic class as common class, and the experimental group participated in after school class additionally. The general class taught track and jump skill for 3 hours a week, and the after school class taught only athletic running skill for 30 minutes a week. Pre and post test assessed to assess students' kinematic changes. Findings indicated that velocity and step rate were increased, and contact time, step length, displacement of center of mass were decreased in the experimental group. In the control group, early velocity, knee/hip angle velocity were increased, and contact time, step length, displacement of center of mass were decreased. In conclusion, the students who only participated in general class, could not maintain athletic skills obtained from the class. However, students who participated in both general and after school class accomplish athletic start skill. This is because Continuous learning effect helped students keep the skill and did not lose the skill. Thus, in order for students to learn specific sport skills, joining after school class with general class together is recommended.

Measurement of the Particle Current Changes Associated with the Flatness of Deflector Mesh Surface in Particle Beam Mass Spectrometer System

  • Kim, Dongbin;Kim, TaeWan;Jin, Yinhua;Mun, Jihun;Lim, In-Tae;Kim, Ju-Hwang;Kim, Taesung;Kang, Sang-Woo
    • Applied Science and Convergence Technology
    • /
    • v.25 no.2
    • /
    • pp.25-27
    • /
    • 2016
  • The surface flatness of metal meshes in a deflector of particle beam mass spectrometer (PBMS) required ideally flat, and this can specify the particle trajectories which goes through the detector. In this research, charged particle current was measured using the different surface roughness deflectors. NaCl particles were generated monodispersed in its size by using differential mobility analyzer and the whole processes were followed the way calibrating PBMS. The results indicate that the mesh surface morphology in the deflector can affect to the particle size and the concentration errors, and sensitivity of PBMS.

Dynamic Behavior of Vacuum Circuit Breaker with Permanent Magnetic Actuator (영구자석형 조작기를 갖는 진공차단기의 동적거동)

  • Yu, Lyun;Kim, Young-Geun;Lee, Sung-Ho;Cho, Hae-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.5
    • /
    • pp.578-585
    • /
    • 2007
  • A vacuum circuit breaker (VCB) with permanent magnet actuator (PMA) has been studied in this study. Electromagnetic field analysis and dynamic simulations have been carried out for optimal design of VCB by using commercial software Maxwell and ADAMS. This simulation model can be an effective method for the VCB, which has non-linear output force of PMA, friction, and impact for operations. An experiment has been conducted to evaluate correctness of the simulated model. By using this evaluated model, the displacement and velocity characteristics of the VCB have been simulated with following conditions : (1) The different output forces of PMA have been applied, (2) The friction conditions in follow lever shaft and moving part have been changed, (3) The mass conditions of moving part have been changed. The simulated results shows that the velocity characteristics are mainly determined by the output force of PMA. The effects due to the changes of friction conditions against the dynamic characteristics was small, and the mass conditions of the moving parts affect the velocity and a bouncing phenomenon of VCB. From these results, the optimal design conditions for the VCB have been derived.

Studies on the Flavor Compounds of Dutch Coffee by Headspace GC-Mass (Headspace GC-MS을 이용한 더치커피의 향기성분분석)

  • Hwang, Seong-Hee;Kim, Kang-Sung;Kang, Hee-Joo;Kim, Jin-Hee;Kim, Min-Jung
    • Korean journal of food and cookery science
    • /
    • v.30 no.5
    • /
    • pp.596-602
    • /
    • 2014
  • Dutch coffee is extracted in low temperature for a longer time than espresso and drip coffee. This study was conducted to investigate changes in the flavor compounds in Dutch coffee resulting from different extraction times and storage days. The fifty six flavor compounds in Dutch coffee were identified using a headspace mass-spectrometer. Major flavor compounds were 2-furfuryl acetate, 5-methylfurfural, pyridine, furfural, 2-acetylfuran, pyridine, 2-methoxyphenol, furfuryl alcohol and some compounds varied with espresso and drip coffee. It was worthy of notice that more diverse compounds were composed of total flavor in Dutch coffee. There were more kinds of flavor compounds in early extracts than in latter ones. The duration of storage didn't significantly affected the peak area percentage of flavor compounds in Dutch coffee except with 2-furfuryl acetate.

A Study on Water Quality Impact by Pollution Source in Yongwon Channel, Busan Newport (부산신항 용원수로에서의 오염원별 수질영향 조사)

  • Kwon, Jae Hyun;Kim, Young Do;Jung, Jae Hoon;Jeong, Weon Mu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.185-196
    • /
    • 2013
  • In Yongwon channel, its natural flow of seawater is blocked by the construction of Busan Newport including the container berth. The channel was transformed into a narrow and long one, where it is possible that ships are only allowed to pass through the north-side channel of Gyeonmado located at the point of river mouth to Songjeongcheon. In addition, Yongwon channel is approximately 100 m wide on average and 3,600 m long, which has the highest slenderness ratio (length/width=36). So it is considered that the changes in the terrain characteristics of Yongwon channel is likely to alter the circulation of sea water, thereby changing its water quality. In this study, the seasonal change and the spatial variation of the water quality in Yongwon channel was analyzed for the effect of land pollution using the measurement data. The mass balance calculation method is used to analyze the water pollution resulting from sediment pollutants. This result shows that the improvement of the water quality in Yongwon channel can be obtained from the sewer pipe modification and the environmental dredging.

Effect of operating conditions on carbon corrosion in High temperature polymer electrolyte membrane fuel cells (HT-PEMFCs) (고온형 고분자 전해질막 연료전지(HT-PEMFC) 구동환경에 따른 탄소 담지체 부식 평가)

  • Lee, Jinhee;Kim, Hansung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • The influence of potential and humidity on the electrochemical carbon corrosion in high temperature polymer electrolyte membrane fuel cells(HT-PEMFCs) is investigated by measuring $CO_2$ emission at different potentials for 30 min using on-line mass spectrometry. These results are compared with low tempterature polymer electrolyte membrane fuel cells(LT-PEMFCs) operated at lower temperature and higher humidity condition. Although the HT-PEMFC is operated at non humidified condition, the emitted $CO_2$ in the condition of HT-PEMFC is more than LT-PEMFC at the same potential in carbon corrosion test. Thus, carbon corrosion shows a stronger positive correlation with the cell temperature. In addition, the presence of a little amount of water activate electrochemical carbon corrosion considerably in HT-PEMFC. With increased carbon corrosion, changes in fuel cell electrochemical characteristics become more noticeable and thereby indicate that such corrosion considerably affects fuel cell durability.

  • PDF

Effects of Particle Measuring Conditions on Diesel Nanoparticles Distribution (입자측정조건이 디젤 나노입자의 입경분포에 미치는 영향)

  • Lee, Jin-Wook;Kim, Hong-Suk;Jeong, Young-Il
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.653-660
    • /
    • 2006
  • Due to the stronger exhaust emission regulations and the introduction of advanced technology in Diesel engine, the specific Diesel particulate matters have decreased by about one order of magnitude since the 1980's. In recent years, particle number emissions rather than particulate mass emissions have become the subject of controversial discussions. Recent results from health studies imply that it is possible that particulate mass does not properly correlated with the variety of health effects attributed to Diesel exhaust. Concern is instead now focusing on nano-sized particles. This study has been performed for the better understanding about the Diesel nano-particle measurement and size distribution characteristics in the exhaust system of a turbo charged Diesel engine. A scanning mobility particle sizer(SMPS) system was applied to measure the particle number and size concentration of Diesel exhaust particles. As the experimental results, the number concentrations in the particle size (Dp<200 nm) were very sensitive to dilution conditions. Specially the changes in nano-particle number concentrations(Dp<50 nm) increased along the downstream of exhaust flow. Also we found the dilution conditions were influencing the condensation of SOF and $H_2O$ during dilution and cooling of hot exhaust.