• 제목/요약/키워드: Mass Spectrometric

검색결과 259건 처리시간 0.023초

탄소 동위원소 분석에 의한 벌꿀의 품질평가법에 관한 연구 (The Quality Assessment of Honey by Stable Carbon Isotope Analysis)

  • 허우덕;하재호;남영중
    • 분석과학
    • /
    • 제5권2호
    • /
    • pp.229-234
    • /
    • 1992
  • 최근 연구가 활발한 동위원소 질량분석기를 이용하여 꿀의 탄소동위원소 비율을 측정, 당의 생성원을 추정하는 새로운 분석방법을 벌굴의 품질평가법에 도입하기위하여 우리 나라에서 생산되는 순수한 꿀에 대해 기존의 방법과 비교분석을 실시하여 동위원소 분석법의 이용 가능성을 분석하였다.

  • PDF

Propionylshikonin form the Roots of Lithospermum erythrorhizon

  • Cho, Man-Ho;Paik, Young-Sook;Hahn, Tae-Ryong
    • Archives of Pharmacal Research
    • /
    • 제22권4호
    • /
    • pp.414-416
    • /
    • 1999
  • A shkionin derivative was isolated from the roots of Lithospermum erythrorhizon with silica gel column chromatography and preparative TLC. The structure of the isolated pigment was identified as propionylshikonin by NMR and mass spectrometric analysis. The isolation of propionylshiknin was for the first time in the nature.

  • PDF

Paint Spray Mass Spectrometry for the Detection of Additives from Polymers on Conducting Surfaces

  • Paine, Martin R.L.;Barker, Philip J.;Blanksby, Stephen J.
    • Mass Spectrometry Letters
    • /
    • 제3권1호
    • /
    • pp.25-28
    • /
    • 2012
  • Paint Spray is developed as a direct sampling ionisation method for mass spectrometric analysis of additives in polymer-based surface coatings. The technique simply involves applying an external high voltage (5 kV) to the wetted sample placed in front of the mass spectrometer inlet and represents a much simpler ionisation technique compared to those currently available. The capabilities of Paint Spray are demonstrated herein with the detection of four commercially available hindered amine light stabilisers; TINUVIN${(R)}$770, TINUVIN${(R)}$292, TINUVIN${(R)}$123 and TINUVIN${(R)}$152 directly from thermoset polyester-based coil coatings. Paint Spray requires no sample preparation or pre-treatment and combined with its simplicity requiring no specialised equipment makes it ideal for use by non-specialists. The application of Paint Spray for industrial use has significant potential as sample collection from a coil coating production line and Paint Spray ionisation could enable fast quality control screening at high sensitivity.

DISSOLUTION AND BURNUP DETERMINATION OF IRRADIATED U-Zr ALLOY NUCLEAR FUEL BY CHEMICAL METHODS

  • Kim, Jung-Suk;Jeon, Young-Shin;Park, Soon-Dal;Song, Byung-Chul;Han, Sun-Ho;Kim, Jong-Goo
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.301-310
    • /
    • 2006
  • Destructive methods were used for the burnup determination of U-Zr alloy nuclear fuel irradiated in the High-flux Advanced Neutron Application Reactor (HANARO) at KAERI. The dissolution rate of unirradiated U-Zr alloy fuel in $HNO_3$/HF mixtures was investigated for the experimental conditions of a different temperature, and initial concentrations of HF and $HNO_3$. The irradiated U-Zr alloy fuel specimen was dissolved in a mixed acid condition of 3 M HNO3 and 1 M HF at $90^{\circ}C$ for 8 hours under reflux. The total burnup was determined from measurement of the Nd isotope burnup monitors. The method includes U, Pu, $^{148}Nd,\;^P{145}Nd+^{146}Nd,\;^{144}Nd+^{143}Nd$ and total Nd isotopes determination by the isotope dilution mass spectrometric method (IDMS) using triple spikes $(^{233}U,\;^{242}Pu\;and\;^{150}Nd)$. The effective fission yield was calculated from the weighted fission yields averaged over the irradiation period. The results are compared with that obtained by the destructive -spectrometric measurement of the $^{137}Cs$ monitor.

Computer-coupled Mass Sepctrometer를 이용한 세포증식과 기질소모의 연속적 On-line추정 (Continuous On-line Estimation of Cell Growth and Substrate Consumption Using a Computer-coupled Mass Spectrometer)

  • 남수완;김정희
    • KSBB Journal
    • /
    • 제4권2호
    • /
    • pp.118-122
    • /
    • 1989
  • Candida utilis를 model균주로 하여 세포증식과 기질소모를 on-line 간접측정하고자 개인용 컴퓨터(IBM PC-AT)와 interface된 quadrupole mass spectrometer로 발효 배기가스를 분석하였다. 5분마다 연속적으로 분석되는 질소, 산소, 이산화 탄소 및 수증기의 mole백분율(%)로부터 산소 소비속도(OUR)와 이산화 탄소 발생속도(CER)를 on-line으로 계산하였다. 미리 실험 결과치로부터 결정한 maintenance와 수율 상수들($k_1k_2 $ 값을 이용하여 세포농도와 기질인 포도당의 농도를 on-line으로 간접추정하였다. 간접추정된 값들은 실험적으로 측정한 세포농도 및 기질농도와 잘 일치함을 알 수 있었다.

  • PDF

MALDI-MS: A Powerful but Underutilized Mass Spectrometric Technique for Exosome Research

  • Jalaludin, Iqbal;Lubman, David M.;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • 제12권3호
    • /
    • pp.93-105
    • /
    • 2021
  • Exosomes have gained the attention of the scientific community because of their role in facilitating intercellular communication, which is critical in disease monitoring and drug delivery research. Exosome research has grown significantly in recent decades, with a focus on the development of various technologies for isolating and characterizing exosomes. Among these efforts is the use of matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS), which offers high-throughput direct analysis while also being cost and time effective. MALDI is used less frequently in exosome research than electrospray ionization due to the diverse population of extracellular vesicles and the impurity of isolated products, both of which necessitate chromatographic separation prior to MS analysis. However, MALDI-MS is a more appropriate instrument for the analytical approach to patient therapy, given it allows for fast and label-free analysis. There is a huge drive to explore MALDI-MS in exosome research because the technology holds great potential, most notably in biomarker discovery. With methods such as fingerprint analysis, OMICs profiling, and statistical analysis, the search for biomarkers could be much more efficient. In this review, we highlight the potential of MALDI-MS as a tool for investigating exosomes and some of the possible strategies that can be implemented based on prior research.

LC/MS/MS를 이용한 비글견의 혈장 중 Doxifluridine 및 5-Fluorouracil의 동시 분석법 Validation (Validation of a Selective Method for Simultaneous Determination of Doxifluridine and 5-Fluorouracil in Dog Plasma by LC-MS/MS)

  • 김기환;김원;김진성;김경일;강원구;이종화;하정헌;정은주
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권3호
    • /
    • pp.179-186
    • /
    • 2007
  • A simple, sensitive and selective liquid chromatographic/tandem mass spectrometric method (LC-MS/MS) was developed and validated for doxifluridine and 5-fluorouracil (5-FU) quantification in dog heparinized plasma. Sample preparation was based on liquid-liquid extraction using a mixture of isopropanol/ethyl acetate (1/9 v/v) to extract doxifluridine, 5-FU and 5-chlorouracil (5-CU, an internal standard) from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 2.7, 1.5 and 1.7 min for doxifluridine, 5-FU and 5-CU, respectively with shorter analysis time within 5 min than previously reported methods. The ionization was optimized using ESI negative mode and selectivity was achieved by tandem mass spectrometric analysis by multiple reaction monitoring (MRM) using the transformations of m/z 244.8>107.6, 129.0>42.0 and 144.9>42.1 for doxifluridine, 5-FU and 5-CU, respectively. The achieved low limit of quantification was 20.0 ng/mL and the assay exhibited linear range of 20-2000 ng/mL ($R^2>0.99957$ for doxifluridine and $R^2>0.99857$ for 5-FU), using $100{\mu}L$ of plasma. Accuracy and precision of quality control samples for both doxifluridine and 5-FU met KFDA and FDA Guidance criteria of 15% for accuracy with coefficients of variation less than 15%. This method demonstrated adequate sensitivity, specificity, accuracy, precision and stability to support the simultaneous analysis of doxifluridine and 5-FU in dog plasma samples in pharmacokinetic and bioequivalence studies.

Determination of MTBE, TBA and BTEX in Soil by Headspace Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권5호
    • /
    • pp.1693-1698
    • /
    • 2012
  • A headspace gas chromatographic mass spectrometric (GC-MS) assay method was developed for the simultaneous determination of methyl tertiary butyl ether (MTBE), $tert$-butyl alcohol (TBA) and benzene, toluene, ethyl benzene and xylene (BTEX) in soil contaminated with gasoline. 2 g of soil sample were placed in a 10 mL headspace vial filled with 5 mL of phosphoric acid solution (pH 3) saturated with NaCl, and the solution was spiked with fluorobenzene as an internal standard and sealed with a cap. The vial was heated in a heating block for 40 min at $80^{\circ}C$. The detection limits of the assay were 0.08-0.12 ${\mu}g$/kg for the analytes. For five independent determinations at 10 and 50 ${\mu}g$/kg, the relative standard deviations were less than 10%. The method was used to analyze fifty six soil samples collected from various regions contaminated with gasoline in Korea. The developed method may be valuable for the monitoring of the analytes in soil.

칩 기반 미세관 HPLC를 이용한 단백체 분석 (Chip-based microcapillary HPLC for proteomic analysis)

  • 김보라;박종문;이후근
    • 분석과학
    • /
    • 제24권6호
    • /
    • pp.407-413
    • /
    • 2011
  • 지난 10년간 고해상도 탠덤질량분석기에 사용되는 다양한 미세관 HPLC들이 개발되어 단백체분석연구에 사용되어져 왔다. 질량분석에 앞선 분리과정은 샘플 중의 불순물을 제거하며, 분석물을 좁은 용리 피크 내에 농축함으로써 이어지는 질량분석의 민감도를 향상시킬 수 있다. 본 총설에서는 복잡한 단백체 분석에 사용되는 미세유체 칩을 기반으로 하는 고성능 분리 기술들의 최근 개발 동향을 고찰하였다.