• 제목/요약/키워드: Mass Spectrometric

검색결과 259건 처리시간 0.022초

Simultaneous Determination of Benzidine, Acetylbenzidine and di-Acetylbenzidine in Rat Urine

  • 신호상;이진현;안혜실;홍춘표;최석남
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권7호
    • /
    • pp.685-688
    • /
    • 2001
  • A gas chromatography/mass spectrometric assay method has been developed for the simultaneous determination of benzidine (BZ), N-acetyl benzidine (ABZ) and N,N-diacetyl benzidine (DABZ) in rat urine. BZ, ABZ and DABZ were extracted from urine at pH 8 with ethyl ether. Conjugated urinary metabolites were extracted at pH 8 after hydrolysis with 1 M HCl for 30 min at 100 $^{\circ}C.$ The dried extract was dissolved in 100 ${\mu}{\ell}$ of ethylacetate and then injected in gas chromatography-mass spectrometric (GC-MS) system without further purification or modification. BZ, ABZ and DABZ have good chromatographic properties and offer very sensitive response for the EI-MS (SIM) without any derivatization. The recoveries for BZ, ABZ and DABZ were about 98.0, 81.8 and 71.4%, respectively, at pH 8.0 and the concentration of 5.0 ng/mL. The coefficients of variation of BZ and ABZ were less than 9.5% from 0.1 to 100 ng/mL and that of DABZ was less than 13% in the same concentration range. The detection limits of the assay were 0.01 ng/mL for both BZ and ABZ, and 0.05 ng/mL for DABZ in urine or plasma 1.0 mL.

High-Performance liquid Chrmatogrphic and Tandem Mass Spectrometric Quantitation of N7-Methyldeoxyguanosin in Methylated Calf Thymus DNA

  • Chae, Whi-Gun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권3호
    • /
    • pp.191-195
    • /
    • 2000
  • Quantitation of N7-methyldeoxyguanosine (N7-MedG) produced in the in vitro N-methly-N-nitrosuourea (NMU) action on thymus DNA has been achieved by enzymatic degradation, liquid chromatoraphic separaphic separation and desorption chemical ionization tandem mass spectrometry. In conjunction with the resolving power HPLC in the separation of isomers, desorprion chemical ionization tandem mass spectrometry has utilized in determining modified nucleosides at low levels using a stable-isotope labled compound as an internal reforence. The quantitative estimation of N7-methyldeoxyguanosine was previously established by an independent HPLC analysis of methylated calf thymus DNA. A sensitive and specific methodogy for the quantitation of N7-MedG at the picomole level using HPLC combined with tandem mass spectrometry without radioisotope labeling process is presented. The potential of the liquid chromatoraphic tandem mass exposure to methlation agents in vitro.

  • PDF

Gold Nanostructure-Based Laser Desorption/Ionization Time-of-Flight Mass Spectrometry for Analysis of Small Biomolecules

  • Hye-Sun Cho;Tae Hoon Seo;Ji Hun Park;Young-Kwan Kim
    • Mass Spectrometry Letters
    • /
    • 제15권1호
    • /
    • pp.26-39
    • /
    • 2024
  • Gold nanostructures (Au NSs) are useful and interesting matrices for mass spectrometric analysis of various biomolecules based on organic matrix-free laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF-MS). Au NSs provide high efficiency and versatility in LDI-TOF-MS analysis based on their well-established synthesis and surface functionalization, large surface area, high laser absorption capacity, and photothermal conversion efficiency. Therefore, Au NSs based LDI-TOF-MS can be a facile, functional, and efficient analytical method for important small biomolecules owing to its simple preparation, rapid analysis, salt-tolerance, signal reproducibility, and quantitative analysis. This review chronologically summarizes the important advance of Au NSs-based LDI-TOF-MS platforms in terms of in-depth mechanism, signal enhancement, quantitative analysis, and disease diagnosis.

Flame Atomic Absorption Spectrometric Determination of Trace Amounts of Thallium after Solid-Liquid Extraction and Preconcentration with Use of 1,10-Phenanthroline onto Benzophenone

  • Taher, Mohammad Ali
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1177-1180
    • /
    • 2003
  • Thallium is quantitatively retained by 1,10-phenanthroline and tetraphenylborate onto benzophenone in the pH range 0-11 from a large volumes of aqueous solutions of various samples. After filtration, the solid mass consisting of thallium complex and benzophenone is dissolved with 5 mL of dimethylformamide and the metal was determined by flame atomic absorption spectrometric. About 0.4 ㎍ of thallium can be concentrated from 400 mL of aqueous sample, where its concentration is as low as 1.0 ng/mL. Eight replicate determinations of 8.0 ㎍/mL of thallium in final dimethylformamide solution gave a mean absorbance of 0.160 with a relative standard deviation of 1.7%. The sensitivity for 1% absorption was 0.22 ㎍/mL. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of thallium in various alloys and biological samples.

Analysis of Agrochemical Residues in Tobacco Using Solid Phase Microextraction-Gas Chromatography with Different Mass Spectrometric Techniques

  • Lee, Jeong-Min;Jang, Gi-Chul;Kim, Hyo-Keun;Hwang, Geon-Joong
    • 한국연초학회지
    • /
    • 제30권2호
    • /
    • pp.117-124
    • /
    • 2008
  • A solid phase microextraction (SPME) method in combination with gas chromatography/mass spectrometric techniques was used for the extraction and quantification of 12 selected agrochemical residues in tobacco. The parameters such as the type of SPME fiber, adsorption/desorption time and the extraction temperature affecting the precision and accuracy of the SPME method were investigated and optimized. Among three types of fibers investigated, polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB), PDMS fiber was selected for the extractions of the agrochemicals. The SPME device was automated and on-line coupled to a gas chromatograph with a mass spectrometer. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS and triple quadrupole MS-MS mode, were compared. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.01$\sim$0.5 $\mu$g/mL) and sensitivity (limits of detection were in the low ng/mL range). The triple quadrupole MS-MS instrument gave better precision than that of quadrupole MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (< 15%). The LODs was fully satisfied the requirements of the CORESTA GRL. Recoveries of 12 selected agrochemicals in tobacco yielded more than 80% and reproducibility was found to be better than 10% RSD so that SPME procedure could be applied to the quantitative analysis of agrochemical residues in tobacco.

Validation and Applications of Gas Chromatography-Combustion/isotope Ratio Mass Spectrometric Method to Control Misuse of Androgens in Human

  • Lee, Kang-Mi;Kim, Ho-Jun;Jeong, Eun-Sook;Yoo, Hye-Hyun;Kwon, Oh-Seung;Jin, Chang-Bae;Kim, Dong-Hyun;Lee, Jae-Ick
    • Mass Spectrometry Letters
    • /
    • 제2권2호
    • /
    • pp.33-36
    • /
    • 2011
  • The misuse of anabolic androgenic steroids is of particular concern in sports and society. Thus, it is of great importance to discriminate endogenous steroids such as testosterone or testosterone prohormones from their chemically identical synthetic copies. In this study, gas chromatography-combustion/isotope ratio mass spectrometric (GC-C/IRMS) method has been developed and validated for discriminating the origin of anabolic androgenic steroids. The method involves the solid-phase extraction, enzymatic hydrolysis with ${\beta}$-glucuronidase, HPLC-fractionation for the cleanup and analysis by GC-C/IRMS. The difference(${\Delta}^{13}C$) of urinary ${\delta}^{13}C$ values between synthetic analogues and endogenous reference compounds (ERC) by GC-C/IRMS was used to elucidate the origin of steroids, and intra- and inter-day precision, specificity and isotope fractionation were evaluated. The present GC-C/IRMS method combined with HPLC cleanup was accurate and reproducible enough to be successfully applied to the test of urine sample from suspected anabolic steroid abusers.

Application of Chemical Ionization Mass Spectrometry to Heterogeneous Reactions of OH with Aerosols of Tropospheric Interest

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2017
  • Studies performed on heterogeneous reactions of hydroxyl radicals (OH) in aerosol materials of tropospheric interest are presented, focusing on the chemical ionization mass spectrometric approach. Kinetic investigations of these reactions reduced deviation in the estimation of OH concentration in the troposphere by atmospheric modeling from field measurements. Recently, OH uptake was investigated under wet conditions to acquire kinetic information under more realistic conditions representative of the troposphere. The information on the mechanism and kinetics of OH uptake by tropospheric aerosol materials will contribute to the updating of atmospheric models, allowing a better understanding of the troposphere.

Evaluation of proteomic strategies for analyzing ubiquitinated proteins

  • Peng, Jun Min
    • BMB Reports
    • /
    • 제41권3호
    • /
    • pp.177-183
    • /
    • 2008
  • Ubiquitin is an essential, highly-conserved small regulatory protein in eukaryotic cells. It covalently modifies a wide variety of targeted proteins in the forms of monomer and polymers, altering the conformation and binding properties of the proteins and thus regulating proteasomal delivery, protein activities and localization. Mass spectrometry has emerged as an indispensable tool for in-depth characterization of protein ubiquitination. Ubiquitinated proteins in cell lysates are usually enriched by affinity chromatography and subsequently analyzed by mass spectrometry for identification and quantification. Ubiquitin-conjugated amino acid residues can be determined by unique mass shift caused by the modification. Moreover, the complex structure of polyubiquitin chains on substrates can be dissected by bottom-up and middle-down mass spectrometric approaches, revealing potential novel functions of polyubiquitin linkages. Here I review the advances and caveats of these strategies, emphasizing caution in the validation of ubiquitinated proteins and in the interpretation of raw data.

Mass Spectrometric Analysis for Discrimination of Diastereoisomers

  • Manshoor, Nurhuda;Weber, Jean-Fré
    • Mass Spectrometry Letters
    • /
    • 제6권4호
    • /
    • pp.99-104
    • /
    • 2015
  • A liquid chromatography mass spectrometry (LC-MS) system was used to identify and distinguish oligostilbene diastereoisomers. A polyphenolic extract from Neobalanocarpus heimii known to be rich in oligostilbenes of various degrees of condensation was used as test material. Fourteen oligostilbenes were isolated from this extract on a fully automated semi-preparative HPLC system. Out of these, two pairs of dimers, one pair of trimers, two pairs of tetramers and a group of four tetramers with similar skeleton were identified as diastereoisomers. Their structures and configurations were established by spectroscopic methods. All isolated compounds were subjected to an LC-MS/MS to study their fragmentation patterns. The experiments were performed on a liquid chromatography-mass spectrometry (LC-MS) with electrospray-ionization (ESI) interface in positive mode. MS/MS spectra of each pure compound were recorded by direct infusion in identical conditions and their product ion spectra were analysed. Some subtle yet significant differences were observed between the spectra of oligostilbenes from the various diastereoisomeric series.

Experimental Study for the Identification of the Nascent Product of OH Heterogeneous Reaction with NaCl using Chemical Ionization Mass Spectrometry

  • Park, Jong-Ho;Ivanov, Andrey V.;Molina, Mario J.
    • Mass Spectrometry Letters
    • /
    • 제3권4호
    • /
    • pp.108-111
    • /
    • 2012
  • An experimental study on the nascent product of the OH heterogeneous reaction with NaCl was performed under dry and wet conditions using a bead-filled flow tube system coupled to a high-pressure chemical ionization mass spectrometer. The ozone concentration in the flow tube for the atomic hydrogen removal was varied in order to control the conversion reaction of molecular chlorine into HCl for the identification of the nascent product. The mass spectrometric observation was that the $O_3$ introduction reduced the concentration HCl, while it increased the concentration of $Cl_2$ and ClO. Based on the experimental results, we suggest that the nascent product of the titled reaction is gaseous $Cl_2$, which is followed by fast conversion into HCl in presence of H. No significant difference in the concentration profile between under dry and wet (RH = 2%) conditions was observed.