• 제목/요약/키워드: Mass Efficiency

검색결과 1,887건 처리시간 0.028초

Novel Extended π-Conjugated Dendritic Zn(II)-porphyrin Derivatives for Dye-sensitized Solar Cell Based on Solid Polymeric Electrolyte: Synthesis and Characterization

  • Kang, Min-Soo;Oh, Jae-Buem;Roh, Soo-Gyun;Kim, Mi-Ra;Lee, Jin-Kook;Jin, Sung-Ho;Kim, Hwan-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권1호
    • /
    • pp.33-40
    • /
    • 2007
  • We have designed and synthesized three Zn(II)-porphyrin derivatives, such as Zn(II) porphyrin ([G-0]Zn-P1) and aryl ether-typed dendron substituted Zn(II)-porphyrin derivatives ([G-1]Zn-P1 and [G-1]Zn-P-CN1). Their chemical structures were characterized by 1H-NMR, FT-IR, UV-vis absorption, EI-mass, and MALDI-TOF mass spectroscopies. Their electrochemical properties were studied by cyclic voltammetry measurement. These Zn(II)-porphyrin derivatives have been used to fabricate dye-sensitized solar cells (DSSCs) based on solid polymeric electrolytes as dye sensitizers and their device performances were evaluated by comparing with that of a standard Ru(II) complex dye. [G-1]Zn-P-CN1 showed the enhanced power conversion efficiency than those of other porphyrin derivatives, as expected. Short-circuit photocurrent density (Jsc), open-circuit voltage (Voc), fill factor (FF), and power conversion efficiency (η) of solid-typed DSSC for [G-1]Zn-P-CN1 were evaluated to be Jsc = 11.67 mA/cm2, Voc = 0.51 V, FF = 0.46, and η = 2.76%, respectively.

서울지역 장기간 강수와 미세먼지의 특성 분석에 기반한 미세먼지 세정효과 (Scavenging Efficiency Based on Long-Term Characteristics of Precipitation and Particulate Matters in Seoul, Korea)

  • 한수지;엄준식
    • 대기
    • /
    • 제33권4호
    • /
    • pp.367-385
    • /
    • 2023
  • The variabilities of precipitation and particulate matters (i.e., PM10 and PM2.5) and the scavenging efficiency of PMs by precipitation were quantified using long-term measurements in Seoul, Korea. The 21 years (2001~2021) measurements of precipitation and PM10 mass concentrations, and the 7 years (2015~2021) of PM2.5 mass concentrations were used. Statistical analysis was performed for each period (i.e., year, season, and month) to identify the long-term variabilities of PMs and precipitation. PM10 and PM2.5 decreased annually and the decreasing rate of PM10 was greater than PM2.5. The precipitation intensity did not show notable variation, whereas the annual precipitation amount showed a decreasing trend. The summer precipitation amount contributed 61.10% to the annual precipitation amount. The scavenging efficiency by precipitation was analyzed based on precipitation events separated by 2-hour time intervals between hourly precipitation data for 7 years. The scavenging efficiencies of PM10 and PM2.5 were quantified as a function of precipitation characteristics (i.e., precipitation intensity, amount, and duration). The calculated average scavenging efficiency of PM10 (PM2.5) was 39.59% (35.51%). PM10 and PM2.5 were not always simultaneously scavenged due to precipitation events. Precipitation events that simultaneously scavenged PM10 and PM2.5 contributed 42.24% of all events, with average scavenging efficiency of 42.93% and 43.39%. The precipitation characteristics (i.e., precipitation intensity, precipitation amount, and precipitation duration) quantified in these events were 2.42 mm hr-1, 15.44 mm, and 5.51 hours. This result corresponds to 145% (349%; 224%) of precipitation intensity (amount; duration) for the precipitation events that do not simultaneously scavenge PM10 and PM2.5.

IODINE REMOVAL EFFICIENCY IN NON-SUBMERGED AND SUBMERGED SELF-PRIMING VENTURI SCRUBBER

  • Ali, Majid;Yan, Changqi;Sun, Zhongning;Gu, Haifeng;Wang, Junlong;Khurram, Mehboob
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.203-210
    • /
    • 2013
  • The objective of this conducted research is to study the iodine removal efficiency in a self-priming venturi scrubber for submerged and non-submerged operating conditions experimentally and theoretically. The alkaline solution is used as an absorbent, which is prepared by dissolving sodium hydroxide (NaOH) and sodium thiosulphate ($Na2S_2O_3$) in water to remove the gaseous iodine ($I_2$) from the gas. Iodine removal efficiency is examined at various gas flow rates and inlet concentrations of iodine for submerged and non-submerged operating conditions. In the non-submerged venturi scrubber, only the droplets take part in iodine removal efficiency. However, in a submerged venturi scrubber condition, the iodine gas is absorbed from gas to droplets inside the venturi scrubber and from bubbles to surrounding liquid at the outlet of a venturi scrubber. Experimentally, it is observed that the iodine removal efficiency is greater in the submerged venturi scrubber as compare to a non-submerged venturi scrubber condition. The highest iodine removal efficiency of $0.99{\pm}0.001$ has been achieved in a submerged self-priming venturi scrubber condition. A mathematical correlation is used to predict the theoretical iodine removal efficiency in submerged and non-submerged conditions, and it is compared against the experimental results. The Wilkinson et al. correlation is used to predict the bubble diameter theoretically whereas the Nukiyama and Tanasawa correlation is used for droplet diameter. The mass transfer coefficient for the gas phase is calculated from the Steinberger and Treybal correlation. The calculated results for a submerged venturi scrubber agree well with experimental results but underpredicts in the case of the non-submerged venturi scrubber.

저온폐열 활용을 위한 암모니아-물 혼합물을 작업유체로 하는 랭킨사이클에 관한 연구 (Study on the Rankine Cycle using Ammonia-Water Mixture as Working Fluid for Use of Low-Temperature Waste Heat)

  • 김경훈;김세웅;고형종
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.570-579
    • /
    • 2010
  • Since the temperature of waste heat source is relatively low, it is difficult to maintain high level of efficiency in power generation when the waste heat recovery is employed in the system. In an effort to improve the thermal efficiency and power output, use of ammonia-water mixture as a working fluid in the power cycle becomes a viable option. In this work, the performance of ammonia-water mixture based Rankine cycle is thoroughly investigated in order to maximize the power generation from the low temperature waste heat. In analyzing the power cycle, several key system parameters such as mass fraction of ammonia in the mixture and turbine inlet pressure are studied to examine their effects on the system performance. The results of the cycle analysis find a substantial increase both in power output and thermal efficiency if the fraction of ammonia increases in the working fluid.

The Effect of Imidazole and 2-Methyl Imidazole on the Corrosion of Mild Steel in Phosphoric Acid Solution

  • Chandrasekara, V.;Kannan, K.;Natesan, M.
    • Corrosion Science and Technology
    • /
    • 제4권5호
    • /
    • pp.191-200
    • /
    • 2005
  • Two azole compounds viz., Imidazole (IM) and 2-Methylimidazole (2-MIM) were studied to investigate their inhibiting action on corrosion of mild steel in phosphoric acid ($H_3PO_4$) solution by mass loss and polarization techniques at 302K-333K. It has been found that the inhibition efficiency of the all inhibitors increased with increase in inhibitor concentration and decreases with increasing temperature and also with increase in acid concentrations. The inhibition efficiency of these compounds showed very good inhibition efficiency. At 0.5% of IM and 2-MIM in 1N and 5N phosphoric acid solution at 302K to 333K for 5 hours immersion period, the inhibition efficiency of 2-Methylimidazole found to be higher than Imidazole. The adsorption of these compounds on the mild steel surface from the acids has been found to obey Tempkin's adsorption isotherm. The values of activation energy ($E{\alpha}$) and free energy of adsorption (${\Delta}G{\alpha}ds$) were also calculated. The plots of log $W_f$ against time (days) at 302K give straight line which suggested that it obeys first order kinetics and also calculate the rate constant k and half life time $t_{1/2}$. Surface was analyzed by SEM and FITR spectroscopy.

유압식 에너지 회생시스템의 성능평가 (Performance Evaluation for Hydraulic Type Energy Regenerative System)

  • 정동수;김형의;강이석
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.136-144
    • /
    • 2006
  • Vehicles usually have 3 types of speed pattern like acceleration, travel, and deceleration. It requires much driving energy from engine while accelerating, preserves much kinetic energy by inertia moment at travel speed, and releases the kinetic energy to the air while decelerating by the break system. If we accumulate the kinetic energy while decelerating and reuse the energy at the accelerating stage, then it can elevate the fuel efficiency, reduce the emission and improve the motive power. This paper proposes a hydraulic type energy regenerative system which converts the kinetic energy into hydraulic energy at the stage of deceleration and reuses it at the starting and accelerating stage of vehicles. The test equipment which has the field condition of city bus was prepared to evaluate the performance for energy regeneration. The test results show that both energy regeneration efficiency and fuel efficiency are improved significantly and the emission is reduced notably.

단순지지 사각 접수 평판의 방사효율 근사식에 관한 연구 (A Study on the Approximate Formula for Radiation Efficiency of a Simply Supported Rectangular Plate in Water)

  • 김현실;김재승;김봉기;김상렬
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.21-27
    • /
    • 2014
  • In this paper, an approximate formula for radiation efficiency of the plate surround by an infinite rigid baffle is studied. The plate is simply supported and one side is in contact with air, while other side with water. By assuming an infinite plate, the fluid loading effect is derived in terms of an effective mass. Based on the observation that the fluid loading effect decreases as frequency increases, the radiation efficiency formula at high frequency, which was originally derived for a plate vibrating in the air, is modified as the approximate formula for a submerged plate. The fluid loading effect is taken into account in the wavenumber of the plate. Comparisons of the approximate formula with the numerical results shows that they match well except the mid-frequency range in which numerical results show many oscillations. In numerically solving the fully coupled equations of motion, fourfold integrals of the impedance coefficients are reduced to single nonsingular integrals, which results in substantial reduction in computing time.

Evaluation of urban pollutant washoff characteristics and treatment efficiency of a small constructed wetland

  • Reyes, Nash Jett DG.;Geronimo, Franz Kevin F.;Kim, Lee-Hyung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.412-412
    • /
    • 2019
  • Nature-based solutions (NBS) offer a wide variety of techniques that promote cost-efficient stormwater management practices. In particular, low impact development facilities utilize NBS principles to restore the ecosystem services in a highly-urbanized area. Despite the advancements in these technologies, several considerations should still be addressed to ensure optimum functionality and attainment of desired pollutant removal efficiency a LID facility. This study evaluated the mass flushing characteristics of pollutants in an urban catchment and the efficiency of a small constructed wetland (SCW) in treating urban stormwater runoff. 21 rainfall events from 2010 to 2018 were monitored to determine and quantify stormwater pollutants. The highest pollutant washoff was observed on rainfall depths ranging from 0.1mm to 10mm, whereas events with greater rainfall depths exhibited lower pollutant concentrations due to dilution effect. However, the SCW manifested lower pollutant-removal performance on rainfall depths exceeding 10mm due to the exceedance of the facility's design rainfall. This study is beneficial in assessing the dynamics of pollutant washoff and efficiency of LID facilities subjected under various external factors.

  • PDF

라이다 데이터를 이용한 PM10, PM2.5 질량소산효율 특성 연구 (The Study of PM10, PM2.5 Mass Extinction Efficiency Characteristics Using LIDAR Data)

  • 김태경;주소희;김가형;노영민
    • 대한원격탐사학회지
    • /
    • 제37권6_2호
    • /
    • pp.1793-1801
    • /
    • 2021
  • 2015년 1월부터 2020년 6월까지 라이다를 이용하여 측정된 532와 1064 nm의 후방산란계수와 532 nm의 편광소멸도를 이용하여 532 nm의 후방산란계수를 PM10, PM2.5-10, PM2.5에 해당하는 세 유형으로 구분하고 지상에서 측정된 질량 농도를 이용하여 각각의 질량소산효율을 산출하였다. 산출된 질량소산효율의 전체 평균값은 PM10, PM2.5-10, PM2.5에서 각각 5.1±2.5, 1.7±3.7, 9.3±6.3 m2/g으로 PM2.5가 가장 높은 값을 보였다. PM10과 PM2.5의 질량 농도가 낮을 때 평균 이상의 높은 질량소산효율이 산출되었으며 질량 농도가 높아질수록 질량소산효율이 감소되는 경향을 확인하였다. 황사의 혼합 정도에 따른 유형별로 질량소산효율을 산출하였을 때, PM2.5-10는 황사의 영향으로 오염입자(pollution aerosol, PA)가 2.1±2.8 m2/g으로 오염입자가 주요한 혼합입자(pollution-dominated mixture, PDM), 황사가 주요한 혼합입자 (dust-dominated mixture, DDM), 순수황사 (pure dust, PD)의 1.1±1.8, 1.4±3.3, 1.1±1.5 m2/g보다 두 배 정도 높은 값을 보였다. 하지만, PM2.5는 9.4±6.5, 9.0±5.8, 10.3±7.5, 9.1±9.0 m2/g으로 유형 구분 없이 비슷한 값을 보였다. PM10의 질량소산효율은 PA, PDM, DDM, PD 에서 각각 5.6±2.9, 4.4±2.0, 3.6±2.9, 2.8±2.4 m2/g으로 황사의 비율이 감소할수록 증가하는 경향을 보였다. 동일한 질량 농도 또는 황사 혼합에 따른 동일한 유형을 보이더라도 PM2.5/PM10 값이 낮아질수록 PM2.5-10의 질량소산효율은 감소하고, PM2.5의 질량소산효율은 증가하는 경향을 보였다.

Phosphorus Accumulation and Utilization Efficiency in Soybean Plant under Atmospheric CO2 Enrichment

  • Sa, Tongmin;Kim, Jong-Soo
    • Journal of Applied Biological Chemistry
    • /
    • 제44권1호
    • /
    • pp.16-19
    • /
    • 2001
  • Soybean plants(Glycine max [L.] merr.) inoculated with Bradyrhizobium japonicum MN110 were grown in growth chambers under 400 or $800{\mu}l{\cdot}l^{-1}$ atmospheric $CO_2$ and harvested at 25, 28, 32, and 35 DAT to examine the effect of $CO_2$ enrichment on phosphorus accumulation, uptake, and utilization efficiency during vegetative growth. Phosphorus concentration in leaf was lower in high $CO_2$ plant by 47% at 25 DAT and 34% at 35 DAT than those in the control plant but phosphorus concentrations in stem, root and nodule were not affected by $CO_2$ enrichment. Total phosphorus accumulation increased 3.9-fold in high $CO_2$ plant and 3.2-fold in the control plant between 25 and 35 DAT. Elevated $CO_2$ caused a decrease in the whole plant phosphorus concentration by 35%, which was due almost entirely to a decrease in the phosphorus concentration of leaves. $CO_2$ enrichment increased phosphorus utilization efficiency in the whole plant by 70% during the experimental period. Plants exposed to high $CO_2$ had larger root systems than under ambient $CO_2$, but high $CO_2$ plants had lower P-uptake efficiency. Averaged over four harvests, plants at high $CO_2$ had 38% larger root mass that was more than offset the 20% lower efficiency of P-uptake and accounted for increased phosphorus accumulation by high $CO_2$ plant. These results suggest that the reduced phosphorus concentration in soybean plant under $CO_2$ enrichment may be an acclimation response to high $CO_2$ concentration or enhanced starch accumulation, resulting in the plants to have a lower phosphorus requirement on a unit dry weight basis or a high phosphorus utilization efficiency under these conditions.

  • PDF