• 제목/요약/키워드: Mass Acquisition

Search Result 108, Processing Time 0.025 seconds

A Study on the Promotion of Reliability Test for Imbedded Software of Weapon System (무기체계 내장형 소프트웨어 신뢰성시험 향상방안에 관한 연구)

  • Heo, Kon Yi;Kwon, Kyoug Yong;Kim, Tae Sik
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.11 no.1
    • /
    • pp.67-72
    • /
    • 2015
  • It has been tested for SW reliability in order to prevent the SW error during the development of weapons systems. According to a recent report, defects such as memory leak, buffer overflow, and null deference occur usually in the development stage, but also in the mass production stage. Although it is intended to enhance the SW test and evaluation to prevent SW failures in the development stage, the non-functional problems like syntax errors are not completely revised due to the limitation of the schedule and costs. In addition, SW failure rate are usually fluctuated by the operational environment through SW upgrade in contrast with HW. In this paper, we propose a method to increase SW reliability in the mass production stage of Korean weapon systems.

Modeling and Prediction of Yarn Density Profiles Using Neural Networks (인공 신경망을 이용한 방적사 굵기 신호의 모델링)

  • Kim, Joo-Yong
    • Textile Coloration and Finishing
    • /
    • v.19 no.6
    • /
    • pp.7-11
    • /
    • 2007
  • A prediction model for yarn density profile was developed using the neural network methodology. The neural network model developed traces mass densities of a yarn within a section and predicts the mass profiles of the next yarn segment yet to be measured. The model does not require an assumption on the existence of a relationship between the past and future data sets. Four high-draft yarns made under different processing conditions were employed in order to test the performance of the model developed. It was shown that the model could predict the yarn density profiles without a significant error.

Numerical Feasibility Study for a Spaceborne Cooler Dual-function Energy Harvesting System

  • Kwon, Seong-Cheol;Oh, Hyun-Ung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.579-587
    • /
    • 2017
  • Spaceborne cryocoolers produce undesirable micro-vibration disturbances during their on-orbit operation, which are a primary source of image-quality degradation for high-resolution observation satellites. Therefore, to comply with the strict mission requirement of high-quality image acquisition, micro-vibration disturbances induced by cooler operation have always been subjected to an isolation objective. However, in this study, we focused on the applicability of energy harvesting technology to generate electrical energy from micro-vibration energy of the cooler and investigated the feasibility of utilizing harvested energy as a power source to operate low-power-consumption devices such as micro-electromechanical system (MEMS) devices. A tuned mass damper (TMD)-type electromagnetic energy harvester combined with a conventional passive vibration isolator was proposed to achieve this objective. The system performs the dual functions of electrical energy generation and micro-vibration isolation. The effectiveness of the strategy was evaluated through numerical simulations.

SWATH-based Comparative Proteomic Analysis of the Mycobacterium bovis BCG-Korea Strain

  • Lee, Won-Kyu;Baek, Je-Hyun;Ryoo, Sung Weon;Yu, Yeon Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.933-937
    • /
    • 2014
  • A derivative of Mycobacterium bovis Bacillus Calmette-Guerin (BCG) has been used for the preparation of tuberculosis vaccines. To establish a Korean tuberculosis vaccine derived from BCG-Pasteur $1173P_2$, genome sequencing of a BCG-Korea strain was completed by Joung and coworkers. A comparison analysis of the genome sequences of the BCG-Pasteur $1173P_2$ and BCG-Korea strains showed marginal increases in the total genome length (~0.05%) and the number of genes (~4%) in the BCG-Korea genome. However, how the genomic changes affect the BCG-Korea protein expression levels remains unknown. Here, we provide evidence of the proteomic alterations in the BCG-Korea strain by using a SWATH-based mass spectrometric approach (Sequential Window Acquisition of all THeoretical mass spectra). Twenty BCG proteins were selected by top-rank identification in the BCG proteome analysis and the proteins were quantified by the SWATH method. Thirteen of 20 proteins showing significant changes were enough to discriminate between the two BCG proteomes. The SWATH method is very straightforward and provides a promising approach owing to its strong reliability and reproducibility during the proteomic analysis.

Application of MALDI Tissue Imaging of Drugs and Metabolites: A New Frontier for Molecular Histology

  • Shanta, Selina Rahman;Kim, Young-Jun;Kim, Young-Hwan;Kim, Kwang-Pyo
    • Biomolecules & Therapeutics
    • /
    • v.19 no.2
    • /
    • pp.149-154
    • /
    • 2011
  • Matrix assisted laser desorption ionization (MALDI) mass spectrometry is commonly used to analyze biological molecules such as proteins, peptides and lipids from cells or tissue. Recently MALDI Imaging mass spectrometry (IMS) has been widely applied for the identification of different drugs and their metabolites in tissue. This special feature has made MALDI-MS a common choice for investigation of the molecular histology of pathological samples as well as an important alternative to other conventional imaging methods. The basic advantages of MALDI-IMS are its simple technique, rapid acquisition, increased sensitivity and most prominently, its capacity for direct tissue analysis without prior sample preparation. Moreover, with ms/ms analysis, it is possible to acquire structural information of known or unknown analytes directly from tissue sections. In recent years, MALDI-IMS has made enormous advances in the pathological field. Indeed, it is now possible to identify various changes in biological components due to disease states directly on tissue as well as to analyze the effect of treated drugs. In this review, we focus on the advantages of MALDI tissue imaging over traditional methods and highlight some motivating findings that are significant in pathological studies.

The Development of Multi-Cavity Cylindrical Gear (멀티 캐비티 실린더 기어 개발)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1552-1557
    • /
    • 2010
  • The cylindrical gear in power window motor assembly is important to doors of automobile. This study is performed for the purpose of getting a manufacturing technique instead of large quantities import and six-cavity mold production. This multi-cavity cylindrical gear is produced under five procedures. The first, mold design of mass-production, the second, making a CAE model for mass-production, the third, manufacturing of sample mold, the fourth, trying-out and measuring of 3 dimensional design, the fifth, acquisition of data analysis and mold modification. Among them, analysis of mass-production using CAE, designing and manufacturing of multi-cavity are successfully performed. In the results, it is concluded that the mold for one gate and eight-cavity based on hot-runner is suitable for making a cylindrical gear.

Assessment of the Purity of Emodin by Quantitative Nuclear Magnetic Resonance Spectroscopy and Mass Balance

  • Park, Sojung;Choi, Yu-Jin;Do, Giang Hoang;Seo, Eun Kyoung;Hyun, Seunghun;Lee, Dongho
    • Natural Product Sciences
    • /
    • v.25 no.3
    • /
    • pp.222-227
    • /
    • 2019
  • Quantitative nuclear magnetic resonance (qNMR) is a well-established method adopted by international pharmacopoeia for quantitative and purity analyses. Emodin is a type of anthraquinone, well known as the main active component of Fabaceae, Polygonaceae and Rhamnaceae. Purity analysis of emodin is usually performed by using the high-performance liquid chromatography (HPLC)-UV method. However, it cannot detect impurities such as salts, volatile matter, and trace elements. Using the qNMR method, it is possible to determine the compound content as well as the nature of the impurities. Several experimental parameters were optimized for the quantification, such as relaxation delay, spectral width, number of scans, temperature, pulse width, and acquisition time. The method was validated, and the results of the qNMR method were compared with those obtained by the HPLC and mass balance analysis methods. The qNMR method is specific, rapid, simple, and therefore, a valuable and reliable method for the purity analysis of emodin.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Optimal Design of a Coudé Mirror Assembly for a 1-m Class Ground Telescope

  • Jaehyun Lee;Hyug-Gyo Rhee;Eui Seung Son;Jeon Geon Kang;Ji-Young Jeong;Pilseong Kang
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.435-442
    • /
    • 2023
  • These days, the size of a reflective telescope has been increasing for astronomical observation. An additional optical system usually assists a large ground telescope for image analysis or the compensation of air turbulence. To guide collimated light to the external optical system through a designated path, a coudé mirror is usually adopted. Including a collimator, a coudé mirror of a ground telescope is affected by gravity, depending on the telescope's pointing direction. The mirror surface is deformed by the weight of the mirror itself and its mount, which deteriorates the optical performance. In this research, we propose an optimization method for the coudé mirror assembly for a 1-m class ground telescope that minimizes the gravitational surface error (SFE). Here the mirror support positions and the sizes of the mount structure are optimized using finite element analysis and the response surface optimization method in both the horizontal and vertical directions, considering the telescope's altitude angle. Throughout the whole design process, the coefficients of the Zernike polynomials are calculated and their amplitude changes are monitored to determine the optimal design parameters. At the same time, the design budgets for the thermal SFE and the mass and size of the mount are reflected in the study.

The Acquisition State and Perceptions about the Clothing-related National Skill Qualification Certificates (의상학 관련 국가기술자격증의 취득실태 및 인식)

  • Han, Seung-Hee;Bae, Ju-Hyeong
    • Journal of Fashion Business
    • /
    • v.12 no.4
    • /
    • pp.158-169
    • /
    • 2008
  • This study aims to survey the perceptions held by students and field workers regarding the clothing-related qualification certificates, which can serve as the base for becoming clothing professionals, to compare and analyze the actual state of qualification certificates on the basic research level, and thus to search for the directions suitable for the clothing-related qualification certificates. The questionnaire method was selected for the study. The responses of 406 copies from students and 81 copies from field workers were used, and frequency analysis and t-test were done with the assistance of spss 10.0 statistics program, The findings are as follows. First, as to the qualification certificates perceived by the students, the certificates of colorist engineer and colorist industrial engineer were known most. 237 students, or 58.4% of the student respondents, had obtained the information about the qualification certificates mainly through the internet and mass media, and 77.3% of the students had a plan to get the qualification certificates. Second, as to the qualification certificates perceived by the field workers, the respondents indicated that school grades(43.2%) would be given the highest additional points at the time of employment, while the clothing-related qualification certificates gathered low responses of 11.1%. The field workers perceived that the qualification certificate of Western suit engineer(pattern) was needed for the job, while 45.4% of them perceived that no qualification certificate was required for the job. Third, both the students and the field workers showed low acquisition levels of the qualification certificates, and in view of their perceptions that the qualification certificates of languages or computer skills were more useful, the improvement is needed in order for the national certificates for the clothing-related skill qualification to develop in the more job-related directions.