• Title/Summary/Keyword: Marine plants

Search Result 450, Processing Time 0.032 seconds

Laser Peening Application for PWR Power Plants (비등수형 원자로 발전소에의 레이저 피닝 적용기술)

  • Kim, Jong-Do;SANO, Yuji
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.13-18
    • /
    • 2016
  • Toshiba has developed a laser peening system for PWRs(pressurized water reactors) as well after the one for BWRs(boiling water reactors), and applied it for BMI(bottom-mounted instrumentation) nozzles, core deluge line nozzles and primary water inlet nozzles of Ikata Unit 1 and 2 of Shikoku Electric Power Company since 2004, which are Japanese operating PWR power plants. Laser pulses were delivered through twin optical fibers and irradiated on two portions in parallel to reduce operation time. For BMI nozzles, we developed a tiny irradiation head for small tubes and we peened the inner surface around J-groove welds after laser ultrasonic testing (LUT) as the remote inspection, and we peened the outer surface and the weld for Ikata Unit 2 supplementary. For core deluge line nozzles and primary water inlet nozzles, we peened the inner surface of the dissimilar metal welding, which is of nickel base alloy, joining a safe end and a low alloy metal nozzle. In this paper, the development and the actual application of the laser peening system for PWR power plants will be described.

A Taxonomical and Ecological Study on the Flora of Chuja Island (추자도 식물상에 관한 분류$\cdot$생태학적 연구)

  • Lim, Joung Whan;Ho Joon Lee;Chang Ho Kim;Seon Ho Kim
    • The Korean Journal of Ecology
    • /
    • v.5 no.4
    • /
    • pp.187-203
    • /
    • 1982
  • The results obtained from te field investigations of Chuja Island conducted for 5 days from July 18 to 22, 1980 and from August 12 to 16, 1981 are summarized as follows: Vascular plants of this island disclosed by the present study consisted of 86 families, 210 genera, 228 species, 38 varieties and 4 래금. Nineteen species of evergreen broad-leaved trees were discovered, including Litsea japonica Juss, Camellia japonica L. and Machilus thunbergii Sieb. et Zucc. These indeciduous latifoliate trees were preserved in poor condition. Ten-twenty years old Pinus thunbergii was confirmed to be the predominant species. Seaside plants encountered were 6 species, including Vitex rotundifolia L. Fil. and Asterspathullfoius Max., but they were poorly distributed. Naturalized plants comprised a total of 12 species. This varied number of species is considered attributable to the frequent access of men owing to convenient marine traffic. the destruction of vegetation of this island may be attributed to human interference (loggin for boat construction, building and charcoal materials) ever escalated by high population density. It is worthy of noting that Bochmeria penosa Nakai et Stake which forms a large community in this island can be used as textile resources.

  • PDF

Stochastics and Artificial Intelligence-based Analytics of Wastewater Plant Operation

  • Sung-Hyun Kwon;Daechul Cho
    • Clean Technology
    • /
    • v.29 no.2
    • /
    • pp.145-150
    • /
    • 2023
  • Tele-metering systems have been useful tools for managing domestic wastewater treatment plants (WWTP) over the last decade. They mostly generate water quality data for discharged water to ensure that it complies with mandatory regulations and they may be able to produce every operation parameter and additional measurements in the near future. A sub-big data group, comprised of about 150,000 data points from four domestic WWTPs, was ready to be classified and also analyzed to optimize the WWTP process. We used the Statistical Product and Service Solutions (SPSS) 25 package in order to statistically treat the data with linear regression and correlation analysis. The major independent variables for analysis were water temperature, sludge recycle rate, electricity used, and water quality of the influent while the dependent variables representing the water quality of the effluent included the total nitrogen, which is the most emphasized index for discharged flow in plants. The water temperature and consumed electricity showed a strong correlation with the total nitrogen but the other indices' mutual correlations with other variables were found to be fuzzy due to the large errors involved. In addition, a multilayer perceptron analysis method was applied to TMS data along with root mean square error (RMSE) analysis. This study showed that the RMSE in the SS, T-N, and TOC predictions were in the range of 10% to 20%.

Dominant-strains Variation of Soil Microbes by Temperate Change II (온도변화에 기인한 토양세균 우점종의 변화에 관한 연구 II)

  • Park, Kap-Joo;Lee, Byeong-Chol;Kim, Soo-Young;Park, Chan-Sun;Cho, Myung-Hwan
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.3
    • /
    • pp.195-201
    • /
    • 2011
  • Today, the weather is changing continually, due to the progress of global warming. As the weather changes, the habitats of different organisms will change as well. It cannot be predicted whether or not the weather will change with each passing day. In particular, the biological distribution of the areas climate change affects constitutes a major factor in determining the natural state of indigenous plants; additionally, plants are constantly exposed to rhizobacteria, which are bound to be sensitive to these changes. Interest has grown in the relationship between plants and rhizopheric microorganisms. As a result of this interest we elected to research and experiment further. We researched the dominant changes that occur between plants and rhizospheric organisms due to global warming. First, we used temperature as a variable. We employed four different temperatures and four different sites: room temperature ($27^{\circ}C$), $+2^{\circ}C$, $+4^{\circ}C$, and $+6^{\circ}C$. The four different sites we used were populated by the following strains: Pinus densiflora, Pinus koraiensis, Quercus acutissima. We counted colonies of these plants and divided them. Then, using 16S rRNA analysis we identified the microorganisms. In conclusion, we identified the following genera, which were as follows: 24 strains of Bacillus, 6 Paenibacillus strains, 1 Pseudomonas strains. Among these genera, the dominant strains in Pinus densiflora was discovered in the same genus. Additionally, those of Pinus koraiensis and Quercus acutissima changed in both genus and strains which changed into the Bacillus genus from the Paenibacillus genus at $33^{\circ}C$.

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.3
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

A Study for Definition and Classification of Offshore Units (해양시설 용어 정의 및 분류 체계에 관한 일고찰)

  • LIM, Youngsub;KWON, Do Joong;LEE, Chang-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.689-701
    • /
    • 2017
  • In recent offshore industries, various ambiguous terms have been used without clear definition or classification, causing difficulties in legal, technical, and educational understanding and usage. For an example, the commonly used term of 'Offshore Plant' in Korea is not an universal word technically. There has been no clear technical or legal definition about the 'Offshore Plant' and its classification is also very ambiguous; sometimes it is used to refer offshore oil and gas production platform or it is used to mean offshore renewable power generation plant in some cases. To build a conceptual framework, therefore, this paper suggests a classification of offshore units (1) using internationally agreed terms, (2) agreed with the technical classification used by the ship classification society and (3) being able to include not only the current but also future concepts of offshore units.

A Study on the Velocity Profiles and Pressure Distributions in Ejector Linking Inhale Duct (흡입관이 부착된 이젝터의 속도분포와 압력분포 연구)

  • Lee Heang-Nam;Park Gil-Moon;Lee Duck-Gu;Sul Jae-Lim
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.488-494
    • /
    • 2005
  • The ejector is used to obtain a vacuum state, and it has been applied to a lot of industry field such as a heat engine, a fluid instrument power plant. a food industry, an environment industry etc., because there is no problem even it is mixed with any kind of liquid, gas. and solid. The flow characteristics in the ejector was investigated by a PIV and a CFD. The agreement between numerical analysis and experiment shows the validity of this study and the results of this study would be useful to the engineers who design for the flow systems for heating. ventilation. air conditioning and wastewater purification plants.

Analysis of combined cycle for desalination process and $CO_2$ refrigeration system (담수화 공정과 이산화탄소 냉동 시스템의 복합사이클 해석)

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.41-48
    • /
    • 2000
  • The characteristics of a combined cycle for the production of fresh water and air-conditioning was analyzed. The combined cycle consisted of an open water cycle and a $CO_2$ refrigeration cycle interlinked in the pre-heater of the water cycle, which is the condenser of the refrigeration cycle. The oprating conditions and criteria for the fresh water production and air-conditioning was described and their effects on the total system were evaluated. The results indicated an increase of desalinated water with the increase of hot water temperature, which resulted in the decrease of cooling capacity of the refrigeration system in this study. However, the energy saving correspond to the pre-heating of the water cycle by the condensing of the refrigeration system shows the avilable advantage of the proposed cycle as compared to other single purpose plants for desalination.

  • PDF

An Experimental Study on the Flew Characteristics in Dividing Rectangular Duet by using a PIV Technique (PIV기법을 이용한 분기 사각덕트네의 유동특성에 관한 실험적 연구)

  • 이행남;박길문;이덕구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1195-1202
    • /
    • 2001
  • The flow characteristics in a bifurcated duct are investigated experimentally. Physical properties such as mean velocity vectors, mean x-y stress distributions, mean vorticity and total pressure distributions are Obtained for three different Reynolds numbers(578, 620, 688) Using PIV measurements and CFD analysis. Also, three different rates of discharge Q=26.11 l/min, Q=28.11 $\ell$/min, Q=31.17 $\ell$/min) were selected foy experimental conditions. The results of this study would be useful to the engineer in designing the flow systems for heating, ventilation, air conditioning and wastewater purification plants.

  • PDF

Development of pub Level Dissolved Oxygen Measuring Technology using Clark Cell (Clark Cell을 이용한 ppb단위 용존산소 측정기술개발)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.375-381
    • /
    • 2002
  • Measuring of the dissolved oxygen is widely used for the environmental control of natural waters, sewage waste treatment, medical and biochemical studies, soil husbandry, food and drug process control, and prevention of corrosion in boilers. Especially, a power plants need special management for preventing accidents from corrosion, therefore, it is essential to measure the concentration of dissolved oxygen in real-time. In this paper we present a method of measuring dissolved oxygen very accurately up to pub units. This method, called polarograph method, is based on the measures of the electric current generated by the oxidation process in cathode and de-oxidation process in anode, assuming that the amount of the current is proportional to the density of dissolved oxygen.