ANALYSIS ON MICROBIOLOGICALLY INFLUENCED CORROSION FAILURE CASE OF SUS316L STAINLESS STEEL WELDS

  • Miyano, Yasuyuki;Yamamoto, Michiyoshi;Watanabe, Kazuya;Kikuchi, Yasushi
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.133-138
    • /
    • 2002
  • Microbiologically Influenced Corrosion (MIC) was suspected in a corrosion failure of cooling system of stainless piping welded joint, carrying marine water. Marine water which is used for cooling water in a plant was transferred to the laboratory and used for experiment. In the first experiment, weld metal samples were exposed to the test solution for 56 days (marine water and sterilized marine water (control)). Surface condition of experimental coupons was observed using a Scanning Electron Microscope (SEM). In another experiment, free corrosion potential of these material was monitored for 56 days. Pitting corrosion was found in the coupons exposed to marine water. Free corrosion potential ennoblement was found to be significant compared to control. It was suspected that this corrosion case was MIC. In the second experiment, coupons were exposed to diluted nutrient medium containing single culture of microbes isolated from the MIC causing marine water sample used for the first experiment. After exposure test, surface condition of experimental coupon was observed using SEM. Pitting corrosion was found in coupons exposed to some of the isolates. The results indicate that they contribute to the corrosive effect of the SUS316L welds.

  • PDF

증기압축식 냉동장치에서 다증관 열교환기의 성능특성에 관한 실험적 연구 (An Experimental Study of the Performance Characteristics on Multiple-tube Heat Exchanger in the Vapor Compression Refrigeration System)

  • 김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.37-43
    • /
    • 2009
  • This paper is performed to develop a tripple-tube exchanger which can improve the system efficiency. Three different tube diameters are compacted by one body(tripple-tube) to recover waste heat from heat exchanging among the fluids. With this, the tripple-tube shows higher cooling capacity than the double-tube after comparing between those two systems. The results of this paper are basic data to design the optimum tripple-tube heat exchanger.

The study on a ship energy management system applied rechargeable battery

  • Jang, Jae-Hee;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.202-207
    • /
    • 2014
  • Recently, the study of energy saving technology of ships begins in earnest, as energy saving policies are performed all around the world. SEMS (Ship Energy Management System) is one of the techniques to increase energy efficiency by applying to a independent system like a ship and offshore. SEMS is composed of Cooling Pump Control System (CPCS), Renewable Energy Emergency Power Control System (REEPCS), Load Control System (LCS), and Heating, Ventilation, and Air Conditioning System (HVACS). SEMS is enable to increase energy efficiency and achieve integrated management through the interlocking of each system. Especially, it is possible to improve the flexibility of the selection of the generator capacity in conjunction with a rechargeable battery and renewable energy. In this paper, SEMS applied rechargeable battery is proposed and simulated. By applying the rechargeable battery, it was confirmed that SEMS applied rechargeable battery can be operated at optimum efficiency of the generator.

선박용 디젤기관의 재킷 냉각청수시스템 성능 비교에 관한 연구 (A study on performance comparison of jacket cooling fresh water system for marine diesel engine)

  • 김덕경;이재현;조권회
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.8-14
    • /
    • 2017
  • 2008년 금융위기로 인하여 세계 경제가 어려워지면서 국제 유가 상승과 물동량이 감소하였으며, 대다수의 대형선사들은 차선책으로 대형선박 발주, 항로변경 및 운항방식 등을 개선하여 적자폭을 줄이게 되었다. 특히, 저속 운항 방식은 눈에 띄는 연료비 절감으로 많은 선주사들로부터 호응을 얻었으나 장기간 저속 운전시 고속 운전에 최적화된 주기관의 재킷 청수 냉각시스템은 정상 운전온도를 유지하지 못하고 하강하여 저온부식의 발생을 가속화 하게 되었다. 이로 인해 엔진의 부하가 낮을 경우 기존에 설치되는 재킷 냉각수 냉각기의 역할은 감소하고 조수기의 사용도 제한이 됨으로 재킷 청수 냉각 시스템의 개선이 필요하게 되었다. 본 논문에서는 선박의 저속운항에 따른 선박용 디젤 주기관의 냉각시스템 개선 사항을 검토하기 위하여, 파나막스급 산적화물선인 82k와 케이프급 산적화물선 180k 선박들을 대상으로 주기관 재킷 냉각수 냉각기를 설치 및 미설치하여 주기관 청수 냉각 시스템의 성능 결과를 검토 및 비교 분석 하여, 현 저속 운항선박에 탑재되는 주기관의 성능변화에 적절한 냉각시스템의 설계 개선방안을 제안하였다.

과냉비등류에 있어서 동블록을 이용한 과도적 냉각실험 (Transient cooling experiments with a cooper block in a subcooled flow boiling system)

  • 정대인;김경근;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.72-79
    • /
    • 1987
  • When the wall temperature is very high, a stable vapor film covers the heat transfer surface. The vapor film creates a strong thermal resistance when heat is transferred to the liquid though it. This phenomenon, called "film boiling" is very important in the heat treatment of metals, the design of cryogenic heat exchangers, and the emergency cooling of nuclear reactors. In the practical engineering problems of the transient cooling process of a high temperature wall, the wall temperature history, the variation of the heat transfer coefficients, and the wall superheat at the rewetting points, are the main areas of concern. These three areas are influenced in a complex fashion such factors as the initial wall temperature, the physical properties of both the wall and the coolant, the fluid temperature, and the flow state. Therefore many kinds of specialized experiments are necessary in the creation of precise thermal design. The object of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The block was 240 mm high and 79 mm O.D.. The coolant flowed throuogh the center of a 10 mm diameter channel in the copper block. In the copper block, three sheathed thermocouples were placed in a line perpendicular to the flow. These thermocouples were used to take measurements of the temperature histories of the copper block.

  • PDF

LED 조명 발열의 순차 제어시스템 연구 (The Study Of Sequence Control for LED)

  • 최형식;윤종수;신희영;임태우
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 후기공동학술대회 논문집
    • /
    • pp.99-100
    • /
    • 2011
  • In this paper, a temperature control for LED(Light Emitting Diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. Also, for minimization study of sound noise and temperature control of an LED lamp, a sequential control algorithm using the cooling fan at the lowest sound noise is presented. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan was performed.

  • PDF

냉난방 시스템계 폐열 회수용 3중관 열교환기 특성에 관한 실험적 연구 (A Experimental Study on the Characteristics of Waste Heat Recovery Type Triple Heat Exchanger in the Cooling and Heating Systems)

  • 이광배;이호생;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1091-1095
    • /
    • 2005
  • This study is performed to develop a tripple-tube exchanger which can improve the system efficiency. Three different tube diameters are compacted by one body(tripple-tube) to recover waste heat from heat exchanging among the fluids. With this, the tripple-tube shows higher cooling capacity than the double-tube after comparing between those two systems. The results of this study are basic data to design the optimum tripple-tube heat exchanger.

  • PDF

LED 조명 발열의 순차 제어시스템 연구 (Temperature Control for LED lamps using RF Communication)

  • 최형식;신희영;오지윤;이상섭
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.130-132
    • /
    • 2012
  • In this paper, a temperature control for LED(Light Emitting Diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan with various size of heat sinks was performed. To minimize the fan sound noise, optimal size of the heat sink was studied. Also, a teleoperting control of LED lamps using RF communication was studied.

  • PDF

CFD를 이용한 Oil Jet의 노즐부 해석 (A Study on Nozzle of Oil Jet using CFD)

  • 정호윤;권지혁;이종훈;최윤환;이연원
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.205-209
    • /
    • 2005
  • Now a days Automobiles are becoming more important in our life, the study on piston of engine is needed because, piston's cooling and lubrication of piston have an effect on the life and efficiency of engine directly. So, this study is about nozzle part of oil jet for cooling piston in the automotive engine. Piston exposes combustion gas of over $2000^{\circ}C$ and is shocked high pressure at the time of explosion shortly. Furthermore strong friction occurs by high speed rotation. The cooling system is considered from oil jet to piston. The previous system cooled the lower part of piston only. So, efficiency was low. To improve this system, make the oil gallery in the piston, and oil flows into the gallery. The value of oil flow rate into the gallery is important. Consequently, the point of this study is the research of investigation of flow characteristics for variable Re number. This study has been modelled by a commercial CFD code FLUENT, allowing to assess its validity

  • PDF