Journal of Advanced Marine Engineering and Technology
/
제32권3호
/
pp.387-393
/
2008
This paper has dealt with the probability of oyster shell desiccant cooling system driven by renewable energy of photo-volatic effect with fundamental experiment. The test materials for desiccant are activated charcoal, silica-gel, hi-dry, and oyster shell. The experiments were mainly performed with focusing on the observation of surface features, adsorption amounts of the adsorbent species, and the effect of temperature. Oyster shell has sufficient probability for using as desiccant in a air-conditioning system. Moreover, the heat releasing device would be attached in the system, the system based with oyster shell can be operated with high efficiency.
Journal of Advanced Marine Engineering and Technology
/
제25권6호
/
pp.1317-1323
/
2001
The circumstance is giving the blow against fishermen with the incoming-decreasing and the difficulty of crew's supply & demand and management. In addition, the depression of the external situation like the departure of WTO system and the plan of EEZ proclaim is forcing fishery into improving their fishing condition. By this international and domestic circumstance, development of the sea water cooling apparatus for fish hold storage is demanded sincerely. First of all, we Investigated load characteristics which based on development of sea water cooling system and optimum fish hold storage. The experimental results is as follows. In creasing the speed of compressor and mass blew rate of refrigerant, the temperature of NaCl solution is low. And the load characteristics experiment on fish hold storage outlet is as fellows. As time goes by, increasing the mass flow rate of NaCl solution, temperature difference between inlet and outlet is small in a model of fish hold storage. These results provide many useful informations applicable to an actual design of sea water cooling system and optimum fish hold storage.
Cooling technology has been a vital prerequisite for the rapid, if not explosive, growth of the electronic equipment industry. This has been especially true during the last 20 years with the advent of intergrated circuit chips and their applications in computers and related electronic products. The purpose of this study is to develop a telecommunication equipment cooling system using a thermoelectric module combined with cooling fan. Thermoelectric module is a device that can perform cooling only by input of electric power. In the present study, the cooling package using the thermoeletric module has been developed to improve the thermal performance. The cooling characteristics of the electronic chip was placed into the subrack and it can be rapidly assembled or disassembled in the equipment rack. As a preliminary experiment, the cooling performances between a conventional way using a cooling fin and a proposed method applying the thermoelectric module was comosed and analyzyed. The cooling performance at a simulated electronic component packaging a thermomodule operated well.
Journal of Advanced Marine Engineering and Technology
/
제39권4호
/
pp.468-472
/
2015
최근 대두되는 선박배기가스 저감 등의 환경정책으로 인하여 에너지의 효율적 이용에 관심이 증가하고 있다. 본 논문에서는 함정의 에너지 효율 향상을 위하여 사용 부하에 따라 해수펌프를 제어하는 고효율 해수냉각시스템을 제안한다. 본 논문에서는 제안하는 시스템의 효과를 알아보기 위하여 추진 디젤기관의 냉각시스템을 모델링 하고 함정 운항특성을 고려한 시뮬레이션을 수행하였다. 시뮬레이션 결과 제안한 고효율 해수냉각시스템이 기존 해수냉각시스템에 비하여 약 53%의 에너지 절감효과가 있었다. 본 연구 결과는 향후 함정 추진 디젤기관의 해수냉각시스템의 성능 향상에 유용한 자료로 활용될 수 있다.
Owing to rapid development of power device and inverters, most of submarines adopt an eletric propulsion system. Although PMPM(Permanent Magnet Propulsion Motor) propulsion system has relatively higher power, energy conversion efficiency and smaller volume than engine propulsion system, it also produces large amount of heat due to current flowing inside motor coils and change of magnetic field induced by iron core. The produced heat in stator and inverter largely affects motor efficiency and bearing lubrication and causes thermal aging while the system is on operation. So, we analyze the existing cooling system and submarine ESS (Energy Saving System) cooling system whose power consumption is reduced. HILS(Hardware In the Loop System) technique is used for the modelling of the submarine cooling system. To confirm the ESS cooling system characteristic, HILS is simulated using LabVIEW with hardware. As a result, the ESS cooling system has the characteristic of better temperature stability and less power consumption than the existing one.
Journal of Advanced Marine Engineering and Technology
/
제34권8호
/
pp.1100-1106
/
2010
LED는 온도가 일정이상 올라가면 효율이 떨어지고 수명이 짧아지는 단점이 있다. 본 연구는 이러한 LED의 효율적인 온도제어에 대한 것이다. LED의 방열을 위해 방열판과 팬을 사용하고 시스템의 온도제어는 원칩 마이크로프로세서와 PID제어를 통해 원하는 온도를 제어할 수 있음을 실험을 통해 확인한다. 궁극적으로 팬을 냉각장치로 사용하고 이를 잘 제어하면 LED 시스템 구동전력의 약 2%만을 사용하여 적절한 조도와 온도를 유지하는 성능을 얻을 수 있음을 제어실험을 통해 확인하였다.
하이드로사이클론은 다양한 산업 방면의 고$\cdot$액 분리를 위해 널리 사용되어왔다. 왜냐하면 하이드로사이클론의 적당한 응용으로 폭넓은 범위의 입자에 적용이 가능하기 때문이다. 불순물을 함유한 해수가 펌프나 열교환기로 흘러가면 그것은 해수 냉각시스템의 효율을 저하시키는 원인이 된다. 본 연구에서는 하이드로사이클론을 이용한 해수 냉각시스템에서 불순물을 분리하는 몇가지 방법을 제시했다. 설계의 영향을 미치는 인자로서 고체농도, 사이클론 입구압력, 하부배출구의 직경과 유량에 따른 하이드로사이클론의 분리효율에 대해 연구를 하였다. 이 연구의 결과는 다음과 같다. 1) 고형물질의 농도가 감소할수록 고$\cdot$액 분리의 효율이 증가하였다. 2) 사이클론 입구압력이 증가함에 따라 분리효율이 증가하였다. 결과적으로 이 연구에서는 하이드로사이클론을 기계류 냉각시스템의 전처리장치로 사용한다면 엔진시스템에서 예상치 못했던 사고를 방지할 수 있을 것이다.
We have researched 10,811 schools to evaluate the characteristics of school buildings and the conditions of heating and cooling systems at the elementary, middle and high school levels. Air conditioning systems in school buildings are related to school scale, and 35% of the researched schools have less than 10 air conditioned classrooms among all of the schools in Korea. The LOADSYS is used to grasp the characteristics of school buildings heating and cooling load. From the results of this work, the heating load differs by nearly 24% between Seoul and Busan, but other than that there are not so many serious regional differences. Almost 85.4% of the classrooms are equipped with heating facilities and 6.9% of them are equipped with heating and cooling facilities. As a result, it is necessary to make improvements in 31.8% of the classrooms using only heaters and 14.6% of the classrooms not equipped with HVAC. The survey shows that there is a wide gap in the heating equipment status of the classrooms according to the region and school district.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.