• 제목/요약/키워드: Marine cooling system

검색결과 186건 처리시간 0.02초

진공냉각장치와 그 이용 (Vacuum Cooling System and Their Use)

  • 김명환;김경근;박형진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.7-16
    • /
    • 1995
  • This article describes the working prnciple, structure and main characteristics of vacuum coolers for vegetables, and gives concrete examples of vacuum coolers that srebeing put to practical use. In particular, newly-developed cavuum coolers with cold storage, utilizing night-time electricity, are focused upon. Processing plants for vegetables, cold-storage rooms and vacuum cooling devices were investigated as possible application of vacuum cooling technology.

  • PDF

각종 이젝터를 이용한 진공냉각장치 (Vacuum Cooling System by the Various Ejectors)

  • 윤석훈;김원녕;전현필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.1-6
    • /
    • 1995
  • Recently, outstanding progresses have been made in food industry, in all the processes involved in the conversion of raw materials into food products. This article describes two kinds of coolers for processing uncooded foor, namely vacuum coolers capable of rapidly cooling decomposing bacteria down to their critical temperature, and also cooling equipment for fresh vegetables based on the same principle as the vacuum cooler.

  • PDF

소형선박 운용자의 냉각수 관리에 관한 고찰 (A Study on the Management of Engine Coolant in Small Fishing Vessels)

  • 김영운
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1734-1744
    • /
    • 2015
  • Majority of marine accidents that occur on fishing vessels are engine accidents. This comprises more than 26 % of the total annual fishing vessel marine accident cases. Large numbers of engine accidents happen in the cooling water system, which are mostly caused by negligence on regular check-up and repair. Notably, small-sized ships have higher engine accidents occurrence rate compared to medium-and large-sized ships. Based on the Report of the Korea Ship Safety Technology Authority, engine accident cases reached 3,032 out of the total 3,081 cases. This study researches on the differences between the small-sized ship pilot, an operator of a vessel engine of less than 200 tons, and a 6th level marine engineer, in terms of the relationship between management forms and what causes the marine accidents in association with the cooling water system. It also studies and analyzes the differences in frequency of the accident occurrence between the two groups. ${\chi}^2$ qualification was imposed through the SPSS statistical analysis program and it got qualified at the significance level of 5%. The research shall be utilized as one of the base line data for the reduction of marine accidents.

소형 선박용 디젤엔진의 수냉식 열교환기 해석 연구 (Study on Simulation of Water Cooling Heat Exchanger for Small Marine Diesel Engine)

  • 양영준;심한섭
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.201-207
    • /
    • 2012
  • This study was carried out to improve the design of heat exchanger for small marine diesel engine. As air pollutants emitted from small marine diesel engine become international problem, IMO(International Marine Organization) tried to establish severe regulations for NOx reduction. The formation of NOx is affected by cooling system, for instance, such as intercooler, heat exchanger, exhaust manifold, and therefore cooling systems are one of essential parts for design of small marine diesel engine. In this study, heat exchanger for small marine diesel engine was modeled and simulated using CATIA V5R19 and ANSYS FLUENT V.13. Thermal flow simulation for heat exchanger was performed to find the optimal design. As the results, maximum velocity of engine coolant in shell inside was 9.1m/s and it was confirmed that outlet temperature and temperature drop for engine coolant could be calculated by simulating proportional relations of temperature between engine coolant and sea water.

An Experimental Study on Reducing Condensation in Marine Air Compressors

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • 해양환경안전학회지
    • /
    • 제21권3호
    • /
    • pp.303-308
    • /
    • 2015
  • Compressed air has many uses on board ship, ranging from diesel engine starting to the cleaning of machinery during maintenance. In an effort to enhance the performance of the marine compressed air system, this work studied a way to reduce condensation from the air compressor via experiments. Especially more condensation is produced when the temperature at compressor outlets and the humidity of the air are higher. so in the research, drain production change has been observed by additionally installing the cooling fan on the suction portion of the air to air compressor and this is the method for reducing the compressed air drain that has passed through the compressor. For the result, it was verified that when the cooling fan was used, less drain was made where per hour it was 500.9ml of drain and the measured result after installing the cooling fan was that less drain was made. Other additional and various researches are needed including experiments like silica gel passing through the suction portion afterwards.

A review on the risk, prevention and control of cooling water intake blockage in coastal nuclear power plants

  • Heshan Lin;Shuyi Zhang;Ranran Cao;Shihao Yu;Wei Bai;Rongyong Zhang;Jia Yang;Li Dai;Jianxin Chen;Yu Zhang;Hongni Xu;Kun Liu;Xinke Zhang
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.389-401
    • /
    • 2024
  • In recent decades, numerous instances of blockages have been reported in coastal nuclear power plants globally, leading to serious safety accidents such as power reduction, manual or automatic power loss, or shutdown of nuclear power units. Loss or shortage of cooling water may compromise the reliability of the cooling water system, thus threatening the operational safety of power plants and resulting in revenue reduction. This study provides a comprehensive review of the current state of cooling water system safety in coastal nuclear power plants worldwide and the common challenges they face, as well as the relevant research on cooling water system safety issues. The research overview and progress in investigation methods, outbreak mechanisms, prevention and control measures, and practical cases of blockages were summarized. Despite existing research, there are still many shortcomings regarding the pertinence, comprehensiveness and prospects of related research, and many problems urgently need to be solved. The most fundamental concern involves understanding the list of potential risks of blockages and their spatially distributed effects in surrounding waters. Furthermore, knowledge of the biological cycles and ecological habits of key organisms is essential for implementing risk prevention and control and for building a scientific and effective monitoring system.

선박동력용 SOFC/GT(무냉각) 하이브리드시스템의 성능 평가 (Performance Analysis of Hybrid SOFC/Uncooled GT System for Marine Power Applications)

  • 김명환;길병래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1050-1060
    • /
    • 2012
  • SOFC시스템 고효율화의 한 방법으로 SOFC/GT 하이브리드시스템은 유효하다. 그러나 시스템의 출력 규모가 수십 MW급의 선박용이라면 하부시스템으로 사용되는 GT시스템의 냉각방식 도입은 장치를 복잡하게 만들고 제어 또한 쉽지 않게 된다. 따라서 선박용으로는 SOFC/GT(유냉각) 하이브리드시스템보다 SOFC/GT(무냉각) 하이브리드시스템이 더 적합해 보인다. 본 연구는 SOFC/GT(무냉각) 하이브리드시스템을 구축하고 그 시스템에 대한 스택의 작동온도와 전류밀도, 가스터빈의 압력비, TIT가 시스템의 성능에 미치는 영향 등을 시뮬레이션을 통하여 검토한 것으로 공기압축기 소요 동력의 증가에도 불구하고 전기적 효율은 상승되며 TIT에는 운전을 위한 제한된 온도범위가 존재한다는 것을 알 수 있었다.

Effect of Air Gap Thickness on Top Heat Loss of a Closed-loop Oscillating Heat Pipe Solar Collector

  • Nguyen, Kim-Bao;Choi, Soon-Ho;Yoon, Doo-Ho;Choi, Jae-Hyuk;Oh, Cheol;Yoon, Seok-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권7호
    • /
    • pp.994-1002
    • /
    • 2009
  • In this paper, effect of air gap thickness between absorber plate and glass cover on top heat loss of a closed loop oscillating heat pipe (CLOHP) solar collector was investigated. The CLOHP, which is made of copper with outer diameter of 3.2mm and inner diameter of 2.0mm, comprises 8 turns with heating, adiabatic and cooling section. The heating section of the heat pipe was attached to absorber plate which heated by solar simulator simulated by halogen lamps. The cooling section of the heat pipe was inserted into collector's cooling section that made of transparent acrylic. Temperatures of absorber plate, glass cover, and ambient air measured by K-type thermocouple and were recorded by MV2000-Yokogawa recorder. Top heat loss coefficients and top heat loss of the collector corresponding to some cases of air gap thickness were determined. The result of experiment shows the optimal air gap thickness for minimum top heat loss of this solar collector.

Design and transient analysis of a compact and long-term-operable passive residual heat removal system

  • Wooseong Park;Yong Hwan Yoo;Kyung Jun Kang;Yong Hoon Jeong
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4335-4349
    • /
    • 2023
  • Nuclear marine propulsion has been emerging as a next generation carbon-free power source, for which proper passive residual heat removal systems (PRHRSs) are needed for long-term safety. In particular, the characteristics of unlimited operation time and compact design are crucial in maritime applications due to the difficulties of safety aids and limited space. Accordingly, a compact and long-term-operable PRHRS has been proposed with the key design concept of using both air cooling and seawater cooling in tandem. To confirm its feasibility, this study conducted system design and a transient analysis in an accident scenario. Design results indicate that seawater cooling can considerably reduce the overall system size, and thus the compact and long-term-operable PRHRS can be realized. Regarding the transient analysis, the Multi-dimensional Analysis of Reactor Safety (MARS-KS) code was used to analyze the system behavior under a station blackout condition. Results show that the proposed design can satisfy the design requirements with a sufficient margin: the coolant temperature reached the safe shutdown condition within 36 h, and the maximum cooling rate did not exceed 40 ℃/h. Lastly, it was assessed that both air cooling and seawater cooling are necessary for achieving long-term operation and compact design.

과냉 회로를 갖는 이산화탄소 냉동시스템에 대한 성능 해석 (Performance Analysis for CO2 System with Sub-cooling loop)

  • 김진만;고성규;김무근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.723-728
    • /
    • 2007
  • In order to evaluate the performance of carbon dioxide cycle with a sub-cooling loop. a simulation system was developed to predict the steady state of $CO_2$ trans-critical cycle. Mathematical models are derived to describe the relationships between the system's coefficient of performance and other operating parameters The mathematical models are based entirely on the basic mass and energy conservation law and thermodynamic and transport properties of carbon dioxide A parametric study has been conducted in order to investigate the effect of sub-cooling loop and various operating conditions on the cycle performance. An optimal mass fraction of a refrigerant flowing through sub-cooling cycle existed for the given evaporating temperature, high pressure and air inlet temperature through gas cooler.