• 제목/요약/키워드: Marginal bone

검색결과 345건 처리시간 0.021초

임프란트와 지대주 간 내측 연결을 갖는 2종의 임프란트에서 저작압이 임프란트 주위골 내응력 분포에 미치는 영향에 관한 연구 (Study on the stress distribution around two types of implants with an internal connection by finite element analysis)

  • 유미경;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.473-488
    • /
    • 2006
  • Adequate bone quality and stress distribution to the bone are of decisive importance for implant success. Even though the success rates of dental implants have been high, implant failures do occur. Overloading has been identified as a primary factor behind dental implant failure. The purpose of this study was to theoretically investigate the effect of two types of implants on the stress distribution in poor bone quality. Employing the finite element method, the study modeled a 4.1 mm diameter, 12.0 mm length implant placed in cortical or spongeous bone. A static loading of lOON was applied at the occlusal surface at 0, 30 degrees angle to the vertical axis of the implant. von Mises stresses concentrations in the supporting bone were analyzed with finite element analysis program. The results were as follows; 1. The stresses at the marginal bone were higher under buccal oblique load(30 degrees off of the long axis) than under vertical load. 2. Under buccal oblique load, the stresses were higher at the lingual marginal bone than at the buccal marginal bone, and the differences were almost the same. 3, Under vertical and oblique load, the stress was the highest at the marginal bone and lowest at the bone around apical portions of implant in cortical bone. 4, Under vertical load, Model 1 showed more effective stress distribution than Model 2 irrespective of bone types. On the other hand, Model 2 showed lower stress concentration than Model 1 under buccal oblique load.

임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구 (An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level)

  • 신동환;조규성;박광호;문익상
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

지대주 풀림과 조임시 지대주 세척방법에 따른 임플란트 주변 골소실의 양에 대한 평가 (Effect of cleansing methods on the bone resorption due to repeated dis/re-connection of implant abutment)

  • 양승민;신승윤;계승범
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.535-542
    • /
    • 2007
  • Background : Repeated dis/re-connection of implant abutment caused bone loss around implant fixtures due to the new formation of biologic width of the mucosal-implant barrier. The aim of this clinical study was to evaluate whether the repeated dis/re-connection of implant abutment cause bone loss clinically and the effect of cleansing methods on a bone loss during the early healing period. Methods : A total 50 implants were installed in 20 patients and repeated dis/re-connection of abutment was performed at the time of surgery and once per week for 12 weeks. 0.9% normal saline solution as group1 and 0.1% chlorhexidine solution as group 2 was used to clean abutments. All patients had radiographs taken at the placement of implant and 4, 8, and 12 weeks postoperatively. The data for bone loss around implant were analyzed. Results: The marginal bone loss at 12 weeks were $1.28{\pm}0.51mm$, $1,32{\pm}0,57mm$ in the mesial and distal sides in group1, $1.94{\pm}0.75mm$, $1.81{\pm}0.84mm$ in group 2, respectively. In view of marginal bone loss, there was not a significant statistical difference between groups. Conclusions : Repeated dis/re-connection of implant abutment may not cause marginal bone loss around implant fixture although limited samples and short-term observation period. In spite of more bone loss in group 2, there was no statistical significant difference between groups. In context of those results, the clinical significance of the repeated dis/re-connection of implant abutment and the cleansing method of abutments is debatable when it comes to marginal bone loss during early healing period.

Effect of loading time on marginal bone loss around hydroxyapatite-coated implants

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Minkyoung;Yang, Hong-So;Yi, Yang-Jin;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권4호
    • /
    • pp.161-167
    • /
    • 2013
  • Objectives: The objective of this study is compare the rate of marginal bone resorption around hydroxyapatite-coated implants given different loading times in order to evaluate their stability. Materials and Methods: The study was conducted retrospectively for one year, targeting 41 patients whose treatment areas were the posterior maxilla and the mandible. Osstem TS III HA (Osstem Implant Co., Busan, Korea) and Zimmer TSV-HA (Zimmer Dental, Carlsbad, CA, USA), which employ the new hydroxyapatite coating technique, were used. The patients were divided into two groups - immediate and delayed loading - and the bone level at the time of loading commencement and after one year of loading was measured using periapical radiography. Differences between the groups were evaluated using Mann-Whitney (${\alpha}$=0.05). Results: For all patients as a single group, the survival rate of the implants was 100%, and the mean marginal bone loss was $0.26{\pm}0.59mm$. In comparison of the differences by loading, mean marginal bone loss of $0.32{\pm}0.69mm$ was recorded for the immediate loading group whereas the delayed loading group had mean marginal bone loss of $0.16{\pm}0.42mm$. However, the difference was not significant (P>0.05). Conclusion: Within the limited observation period of one year, predictable survival rates can be expected when using immediately loaded hydroxyapatite-coated implants.

Beagle dog를 이용한 임프란트 사이의 간격에 따른 골흡수에 대한 방사선 및 조직학적 평가 (INFLUENCE OF INTERIMPLANT DISTANCE ON BONE RESORPTION : A RADIOLOGICAL AND HISTOLOGICAL STUDY IN BEAGLE DOGS)

  • 이수연;이재욱;김진욱;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권5호
    • /
    • pp.571-577
    • /
    • 2008
  • Introduction: Possible etiologic factors associated with bone loss around implants after implantation are surgical trauma, occlusal overload, periimplantitis, presence of micro gap and the formation of biologic distances. Tarnow et al. observed that the crestal bone loss was greater when the distance between the implants was <3mm than when the implants were ${\geq}\;3mm$ apart. The aim of this study was to evaluate the influence of different interimplant distance on marginal bone and crestal bone resorption in the beagle dogs. Materials and methods: The mandibular premolars of 5 dogs were extracted bilaterally. After 12 weeks of healing, each dog received 7 implants. On each side, implants were separated by 2mm (Group 1) and by 5mm (Group 2). After 16 weeks of healing, the dogs were sacrificed. Marginal bone loss was determined through linear measurements made between the implant-abutment junctions and the most coronal portions of the bone in contact with the implant surface. A line was drawn uniting the implant-abutment junctions of the adjacent implants, and a linear measurement was made at the midpoint in the direction of the most coronal peak of the interimplant bone crest to determine the crestal bone loss. Both of them was measured radiologically and histologically. Result and conclusion: In radiological analysis, the mean of marginal bone loss was $1.26{\pm}0.14mm$ for group 1 and $1.23{\pm}0.34mm$ for group 2, the mean of crestal bone loss was $1.10{\pm}0.14mm$ for group 1 and $1.02{\pm}0.30mm$ for group 2. The results were not statistically significant between 2 groups. In histological analysis, the mean of marginal bone loss was $1.63{\pm}0.48mm$ for group 1 and $1.62{\pm}0.50mm$ for group 2, the mean of crestal bone loss was $1.23{\pm}0.35mm$ for group 1 and $1.15{\pm}0.39mm$ for group 2. The differences were also not statistically significant. The clinical significance of this result is that the increase in the crestal bone loss results in the increase in the distance between the base of the interproximal contact of the crowns and the bone crest, and this determines if papilla will be present or absent between implants. Considering this fact, keeping up sufficient interimplant distance is important to minimize crestal bone loss.

7년 이상 기능한 임플란트의 변연골 흡수와 생존율에 영향을 주는 요인 (Factors associated with the survival rate and the marginal bone loss of dental implant over 7-years loading)

  • 최정혁;고재권;권은영;주지영;이주연;김현주
    • 구강회복응용과학지
    • /
    • 제34권2호
    • /
    • pp.116-126
    • /
    • 2018
  • 목적: 본 연구는 7년 이상 기능한 임플란트의 생존율과 평균 변연골 수준에 영향을 미치는 요인을 분석하고자 하였다. 연구 재료 및 방법: 92명의 환자에서 178개의 임플란트를 대상으로 하였다. 임상적 및 방사선학적 검사를 통해 임플란트 관련 요인(임플란트 직경, 임플란트 길이, 상부 보철물 고정 유무), 환자 관련 요인(성별, 흡연, 치태지수, 유지 치주치료 순응도) 및 수술 관련 요인(술자 숙련도, 골재생술 시행 유무)을 조사하였다. 구내 표준 방사선 촬영 이 후 각 임플란트의 근심 및 원심 변연골 수준은 이미지 분석 소프트웨어 프로그램을 사용하여 측정하였다. 결과: 임플란트의 생존율은 94.94%였고, 평균 변연골 흡수는 $0.89{\pm}1.05mm$였다. 임플란트 길이와 치태지수는 임플란트 생존율과 통계적으로 유의하였다(P < 0.05). 흡연과 골재생술 시행 유무는 변연골 흡수와 통계적으로 유의하였다(P < 0.05). 결론: 본 연구에서 7년 이상 기능한 임플란트는 양호한 생존율과 변연골 수준을 보였다. 임플란트의 장기적인 유지를 위해서는 임플란트의 길이, 치태조절에 유의하며 변연골 수준의 유지를 위해서는 골재생술의 신중한 적용, 흡연의 조절이 필요하다.

즉시 하중 임플란트에서 변연골 흡수량에 관한 후향적 연구 (Retrospective study on marginal bone resorption around immediately loaded implants)

  • 이성훈;정지혜;이진한;조혜원
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.114-119
    • /
    • 2018
  • 목적: 원광대학교 치과대학병원 임플란트 센터에서 임플란트를 식립한 후 1주일 내에 임시보철물을 수복한 다음, 즉시 하중을 가한 환자들을 대상으로 골 흡수량을 측정하고자 하였다. 이러한 후향적 분석을 통하여 임플란트에 대한 즉시 하중의 임상적 근거를 보강하고 주의해야 할 사항 등을 파악하고자 하였다. 대상 및 방법: 2005년 1월 1일부터 2016년 6월 31일 사이에 원광대학교 치과대학병원 임플란트 센터에서 임플란트를 식립한 후 1주일 내에 임시보철물을 수복한 환자들을 대상으로 하여 진료기록부와 방사선 사진을 조사하였다. 총 임플란트의 수는 70개였으며, 임플란트의 제조회사, 길이, 직경, 체결 방식에 따른 변연골의 흡수량을 측정하였다. 변연골의 흡수량을 측정하기 위해 임플란트 식립 직후와 6개월 이후의 치근단 방사선 사진을 비교 분석하였다. 통계 프로그램인 SPSS 22.0을 이용하여 Mann-whitney U test와 Kruskal-wallis test를 시행하였다. 결과: 즉시 하중 임플란트 군에서 임플란트와 지대주의 연결 구조에 따른 변연골 흡수량을 비교한 결과 내부 육각 연결 구조 임플란트에서의 변연골 흡수량은 평균 $1.24{\pm}0.72mm$, 외부 육각 연결 구조 임플란트에서 $1.73{\pm}1.27mm$로 나타났으며 통계적으로 유의한 차이를 보였다. 임플란트 제조회사, 길이, 직경에 따른 변연골 흡수량의 차이는 통계적으로 유의한 차이를 보이지 않았다. 결론: 즉시 하중 임플란트에서 내부 육각 연결 구조 임플란트에서의 변연골 흡수량은 외부 육각 연결 구조 임플란트에서의 변연골 흡수량보다 적게 나타났으며, 임플란트의 다른 조건들에서는 변연골 흡수량에 차이를 보이지 않았다.

임플란트 고정체와 지대주 간의 전하중 크기가 골응력에 미치는 영향에 대한 유한요소해석 (Effect of Implant Preload on the Marginal Bone Stresses Studied by Three Dimensional Finite Element Aanalysis)

  • 남효준;조광헌
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.127-138
    • /
    • 2012
  • 본 연구에서는 임플란트 고정체와 지대주 간의 전하중 크기가 임플란트 주위 변연골의 응력분포에 미치는 영향에 대해 조사하였다. 해석 모델은 하악골에 식립되는 단일 임플란트(solid형 지대주와 submerged 형 고정체)로 제작되었고, 외력 조건으로는 임플란트 지대주 상부에 100N의 기능력이 협설 방향으로 30도 경사져 협측으로 작용하도록 설정하였다. 전하중의 크기가 변연골 응력 분포에 어떠한 차이가 생기게 하는지를 조사하기 위해 다섯개의 다른 전하중의 크기(0, 200, 400, 600, 800N)를 부여하였다. 모든 분석은 선형 탄성을 가정하여 ABAQUS/CAE(ver6.10-1, HKS, Fremont, CA, USA) 프로그램을 사용하였다. 임플란트 주위 변연골 응력분포의 차이는 전하중의 크기와 관련이 있었다. 100N의 교합력 하에 전하중이 0인 경우 변연골(임플란트 벽에서 0.1mm 떨어진 부분)에서 압축 응력은 28.33MPa이었는데, 전하중을 200N 증가시킬 때마다 1.76MPa씩 증가하였다. 이런 방식으로 800N의 전하중을 가할 때 나타나는 최대 압축 응력은 35.18MPa이었다. 반면 변연골에서의 인장 응력은 전하중이 증가할 수록 감소하였다. 임플란트 고정체와 지대주 간의 전하중은 변연골에서의 압축 응력을 증가시킬 수 있으나 기능력에 비하면 그 효과는 미미할 것으로 판단된다.

두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study) (Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study)

  • 이지은;허성주;곽재영;김성균;한종현
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.169-174
    • /
    • 2008
  • 목적: 치과 임플랜트 주위의 변연골 변화는 임플랜트의 기능적인 유지 뿐만 아니라 심미적 성공을 위해서도 중요하다. 변연골의 유지를 위한 임플랜트 디자인이 연구되고 있다. 이번 예비 연구는 두 종류의 external hex implant 시스템에서 임플랜트의 상부 미세 나사산이 변연골 변화량에 미치는 영향을 평가하고자 한다. 재료 및 방법: 총 24명의 환자를 대상으로 $Br{{\aa}}nemark$ 임플랜트 식립군 (1군, 거친 표면 임플랜트, 20개)과 원플란트 임플랜트 식립군 (2군, 미세나사산을 가진 거친 표면 임플랜트, 20개)으로 분류하였다. 기준 시점 (임플랜트 부하)과 부하를 가한 1년 뒤 임상적, 방사선학적 검사를 시행하였다. UTHSCSA Image Tool을 이용하여 임플랜트-보철 경계부로부터 변연골 높이 변화량으로 계측하였다. 계측치는 SAS 프로그램을 이용하여 three-level ANCOVA로 통계처리 하였다. 결과: 기준 시점과 비교하여 1년 기능 후, 두 그룹 간의 변연골 소실 변화량에 있어서 통계학적으로 유의한 차이가 있었다 (P<0.05). 1군의 평균 변연골 높이 변화량은 $0.83{\pm}0.31mm$, 2군에 있어서는 $0.44{\pm}0.36mm$ 이었다. 미세나사산을 가진 거친 표면 임플랜트가 미세나 사산을 가지지 않은 거친 표면 임플랜트 보다 더 적은 변연골 소실 변화량을 보였다. 결론: 미세나사산을 가진 거친 표면 임플랜트가 기능적 부하 후 변연골 높이를 유지하는데 있어 더 유리한 디자인으로 보인다.

공간이 협소한 하악 전치부에서 치은하 형태(Subgingival contour)의 중요성 (Importance of subgingival contour of anterior mandibular region with narrow space)

  • 이정삼
    • 대한심미치과학회지
    • /
    • 제31권1호
    • /
    • pp.4-10
    • /
    • 2022
  • 하악 전치부에 임플란트를 이용한 수복시 몇가지 어려운 점이 있는데 그중 하나가 전 후방으로 공간이 부족하다는 것이다. 공간이 부족한 경우에 임플란트를 적절한 위치에 식립하는 것도 쉽지 않을뿐아니라 선택할 수 있는 임플란트도 제한될 수있다는 것이다. 적절한 위치에 적절한 임플란트를 식립한 경우에도 보철의 형태에따라 주변치아와 임플란트 주변골에 상당히 큰 영향을 미칠수 있는데 어떤 경우는 임플란트가 주변골을 손상시키는 위해로운 영향을 줄수도 있다. 이번 증례 발표에서는 비교적 양호한 증례와 불량한 증례를 통해서 치은하 형태(Subgingival cotour)의 차이가 임플란트 주위 Marginal bone과 인접치아의 Interproximal bone의 Biology에 다른 결과를 줄수도 있다는 것을 확인할 수있다.