• 제목/요약/키워드: Marginal Adaptation

검색결과 107건 처리시간 0.025초

Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.439-448
    • /
    • 2016
  • PURPOSE. The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND METHODS. Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a $5^{\circ}$ convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed. RESULTS. The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and $117{\mu}m$ and those from Zirkonzahn system were between 111 and $115{\mu}m$. Marginal discrepancies of copings made with Ceramil system were between 101 and $131{\mu}m$ and those from Zirkonzahn system were between 116 and $131{\mu}m$. CONCLUSION. Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.

유구치 기성 금관의 변연 적합도에 관한 연구 (MARGINAL ADAPTATION OF STAINLESS STEEL IN POSTERIOR PRIMARY TOOTH)

  • 우주형;장철호;김정욱;장기택;김종철
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.27-35
    • /
    • 2007
  • 본 연구의 목적은 발거된 기성 금관 수복 유구치를 대상으로 변연 적합도를 관찰 분석하는 것이다. 서울대학교 치과병원 소아치과에서 수거한 3M사의 기성 금관 수복 유구치를 대상으로 하였다. 상악 제 1유구치 42개, 상악 제 2유구치 25개, 하악 제 1유구치 37개, 하악 제 2유구치 28개를 대상으로 기성 금관의 변연에 따라 치근을 절단한 후 단면을 Fine Pix S602 디지털 카메라로 촬영한 후 Kappa image base program을 이용해 우각 부위 및 임의로 20부분의 변연 간격과 전체 기성 금관 면적 중 변연 간격의 면적이 이루는 비율을 측정하여 다음과 같은 결과를 얻었다. 1. 평균 변연 간격은 상악 제 2유구치, 하악 제 1유구치, 하악 제 2유구치, 상악 제1 유구치 순으로 높았다 (P<0.05). 2. 평균 변연 간격 면적의 비율은 치아의 종류에 관계없이 약 20%를 상회하는 값을 보였다. 3. 상악 제 1,2유구치에서는 근심면의 변연 간격이 가장 컸고, 하악 제 1유구치에서는 원심 설면, 하악 제 2유구치에서는 협면에서 변연 간격이 가장 큰 값을 보였다.

  • PDF

Deep proximal margin rebuilding with direct esthetic restorations: a systematic review of marginal adaptation and bond strength

  • Hoda S. Ismail;Ashraf I. Ali;Rabab El. Mehesen;Jelena Juloski;Franklin Garcia-Godoy;Salah H. Mahmoud
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.15.1-15.18
    • /
    • 2022
  • This review aimed to characterize the effect of direct restorative material types and adhesive protocols on marginal adaptation and the bond strength of the interface between the material and the proximal dentin/cementum. An electronic search of 3 databases (the National Library of Medicine [MEDLINE/PubMed], Scopus, and ScienceDirect) was conducted. Studies were included if they evaluated marginal adaptation or bond strength tests for proximal restorations under the cementoenamel junction. Only 16 studies met the inclusion criteria and were included in this review. These studies presented a high degree of heterogeneity in terms of the materials used and the methodologies and evaluation criteria of each test; therefore, only a descriptive analysis could be conducted. The included studies were individually evaluated for the risk of bias following predetermined criteria. To summarize the results of the included studies, the type of restorative material affected the test results, whereas the use of different adhesive protocols had an insignificant effect on the results. It could be concluded that various categories of resin-based composites could be a suitable choice for clinicians to elevate proximal dentin/cementum margins, rather than the open sandwich technique with resin-modified glass ionomers. Despite challenges in bonding to proximal dentin/cementum margins, different adhesive protocols provided comparable outcomes.

주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구 (THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS)

  • 오수연;방몽숙;양홍서;박상원;박하옥
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

The use of definitive implant abutments for the fabrication of provisional crowns: a case series

  • Bilhan, Hakan;Geckili, Onur;Mumcu, Emre
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.248-252
    • /
    • 2011
  • Purpose: The anterior region is a challenge for most clinicians to achieve optimal esthetics with dental implants. The provisional crown is a key factor in the success of obtaining pink esthetics around restorations with single implants, by soft tissue and inter-proximal papilla shaping. Provisional abutments bring additional costs and make the treatment more expensive. Since one of the aims of the clinician is to reduce costs and find more economic ways to raise patient satisfaction, this paper describes a practical method for chair-side fabrication of non-occlusal loaded provisional crowns used by the authors for several years successfully. Methods: Twenty two patients (9 males, 13 females; mean age, 36,72 years) with one missing anterior tooth were treated by using the presented method. Metal definitive abutments instead of provisional abutments were used and provisional crowns were fabricated on the definitive abutments for all of the patients. The marginal fit was finished on a laboratory analogue and temporarily cemented to the abutments. The marginal adaptation of the crowns was evaluated radiographically. Results: The patients were all satisfied with the final appearance and no complications occurred until the implants were loaded with permanent restorations. Conclusions: The use of the definitive abutments for provisional crowns instead of provisional abutments reduces the costs and the same results can be obtained.

열-가압을 이용한 금속 도재관과 전통적인 금속 도재관의 변연 적합도 비교 연구 (Comparative study in marginal fit of a pressed ceramic and feldspathic porcelain fused to metal restoration)

  • 김윤영;박윈희;유동엽;이영수
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.273-279
    • /
    • 2010
  • 연구 목적: 본 연구의 목적은 전통적인 금속 도재관과 열-가압을 이용한 금속-도재관의 변연 적합도를 비교하는 것이다. 연구 재료 및 방법: 상악 제1소구치 레진 치아를 교합면 2.0 mm, 협, 설면과 인접면을 1.0 mm 두께로 삭제하였으며, 변연 형태는 chamfer margin으로 그리고 축면 경사는 6도 taper로 삭제하였다. 삭제한 레진치를 복제하여 금속 다이 20개를 제작하였고, 이 금속 다이를 인상 채득하여 작업을 위한 석고 다이를 제작하였다. 금속 도재관과 $PoM^{(R)}$ 시스템 (Ivoclar vivadent., Liechtenstein)의 두 그룹으로 나누어 금속 코핑을 각각 10개씩 총 20개를 제작하였으며, 광학 현미경을 이용하여 변연 간격을 측정하였다. 도재 축성 후, 위와 동일한 방법으로 변연 간격을 측정하였다. 통계 처리는 Wilcoxon Signed Ranks test와 Mann Whitney U test를 이용하여 분석하였다. 결과: 본 연구의 결과는 다음과 같다. 1. 금속 도재관은 코핑 상태 ($64.93{\pm}12.48\;{\mu}m$)와 도재 축성 후 ($63.43{\pm}12.86\;{\mu}m$)의 변연 간격에 유의성 있는 차이를 보이지 않았다. 2. $PoM^{(R)}$ 시스템은 코핑 상태 ($50.00{\pm}12.28\;{\mu}m$)와도재축성후($56.72{\pm}13.80\;{\mu}m$)의 변연 간격에 유의성 있는 차이를 보이지 않았다. 3. 금속 도재관과 $PoM^{(R)}$ 시스템 변연 간격은 유의성 있는 차이를 보이지 않았다. 결론: $PoM^{(R)}$시스템은 왁스 소결법을 이용해 변화가 적은 기술적인 이점이 있으며, 세밀한 기술을 요구하는 축성 방법과는 대조적으로 왁스 성형으로 도재의 완전한 형태를 만들 수 있는 편리함을 제공하는 장점을 가진다. 본 연구 결과와 이런 장점을 토대로 앞으로 임상적 사용을 고려해 볼 수 있을 것으로 사료된다.

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

  • Tekin, Yadel Hazir;Hayran, Yeliz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.283-290
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55℃/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey's HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 ㎛ even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

디지털 광공정 방식에 의해 출력된 치과용 보철물의 품질 분석 (Analysis of the quality of dental prostheses printed by digital light-processing technology)

  • 김재홍;김기백
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.197-201
    • /
    • 2020
  • Purpose: This study aimed to assess the quality of dental prostheses printed by digital light-processing (DLP) technology. Methods: Ten experimental models were prepared. The ten specimens that were printed by DLP technology constituted the DLP group. The ten specimens that were produced in the same model by the casting method constituted the control group. The marginal gaps of the 20 specimens produced were measured. These gaps were measured by a silicon replica technique at two abutments of the specimen. Therefore, 20 marginal gaps were measured in each group. An independent sample t-test was performed to compare the marginal gaps measured in the two groups (α=0.05). Results: According to the results of the measurement, there was a significant difference between the mean marginal gap of the control group (78.8 ㎛) and that of the DLP group (91.5 ㎛), p<0.001. Conclusion: Although the mean marginal gaps of dental fixed prostheses produced by the DLP method was higher than the mean marginal gap of those produced by the casting method, it was considered to be within the clinical threshold value suggested by some previous studies.

치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구 (A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems)

  • 정창섭;박종경
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.