• Title/Summary/Keyword: Manual shut down

Search Result 2, Processing Time 0.023 seconds

The Analysis of Emergency Response Guide for Hydrogen Fuel Cell Vehicle (수소연료전지 자동차의 긴급대응 가이드 분석)

  • Lee, Kwang-Ju;Lee, Jong-Tai;Yong, Gee-Joong
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.2
    • /
    • pp.156-161
    • /
    • 2012
  • In case of commercializing of the hydrogen fuel cell vehicle, the suitable emergency response guide is necessary to prepare an accident. In order to suggest the suitable guide for the domestic affairs, the existing external guide about GM, Ford, Honda, and Hyundai was reviewed. The emergency response guides in CAFCP and main FC vehicle makers were included in the analysis. As the results, it was found that the design and make of vehicle for the domestic user are demanded in the emergency response and the guide is made with the shut-down manual picked out for the rescuer and repair man as well as user.

A Comparative Case Study of 2016 Gyeongju and 2011 Virginia Earthquakes (2016년 경주지진과 2011년 미국 버지니아지진에 대한 비교 연구 및 사례 분석)

  • Kang, Thomas H.K.;Jeong, Seung Yong;Kim, Sanghee;Hong, Seongwon;Choi, Byong Jeon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.443-451
    • /
    • 2016
  • A Gyeongju earthquake in the magnitude of 5.8 on the Richter scale (the moment magnitude of 5.4), which was recorded as the strongest earthquake in Korea, occurred in September 12, 2016. Compared with the 2011 Virginia earthquake, the moment magnitude was slightly smaller and its duration was 3 seconds, much shorter than 10 seconds of the Virginia earthquake, resulting in relatively minor damage. But the two earthquakes are quite similar in terms of the overall scale, unexpectedness, and social situation. The North Anna Nuclear Power Plant, which is a nuclear power plant located at 18 km away from the epicenter of the Virginia earthquake, had no damage to nuclear reactors because the reactors were automatically shut down as the design basis earthquake value was exceeded. Ground accelerations of the 2016 Gyeongju earthquake did not exceed the threshold value but the manual shutdown was carried out so that Wolsong Nuclear Power Site was not damaged. Damaged historic homestead house and masonry structures due to the Virginia earthquake have been repaired, reinforced, and rebuilt based on a long-term earthquake recovery project. Likewise, it will be necessary to carefully carry out an earthquake recovery planning program to improve overall seismic performance and to reconstruct the historic buildings and structures damaged as a result of the Gyeongju earthquake.