• 제목/요약/키워드: Manual probe

검색결과 28건 처리시간 0.025초

원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발 (Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant)

  • 서동만;박문호;홍순신
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

역전파알고리즘을 이용한 대피저항율추정에 관한 연구 (A Study on the Estimation of Earth Resistivity using Backpropagation Algorithm)

  • 박경열;유보혁;석진욱;최종기;정길조;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.203-205
    • /
    • 1997
  • In this paper, we present a useful method of estimating earth resistivity using BP algorithm in Neural-Networks. From this method, equivalent earth resistivity(EER) can be obtained directly using training data composed of field-measured apparent resistivity and probe distance. This approach can reduce errors which is conventionally raised from manual operation of calculating EER. To evaluate its accuracy and convenience, the result of proposed method is compared to that of conventional methods, graphical($\rho$-a graph) and numerical(CDEGS program), respectively.

  • PDF

펄스지령법에 의한 머시닝센터상의 3차원 형상정보 수집 (The collecting of 3dimensional data from the way of pulse generating at the M/C)

  • 강효석;임한석;김선호;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.396-399
    • /
    • 1995
  • In this study, Acquisition system is proposed to acquire 3 dimensional data of the free surface model using direct pulse control to machining center. Todo this, I/F to connect between manual operating handle and computer is made, and 3 dimensional shape measuring algorithm using Z-map is applied. The 3 dimensional shape data of the free surface model measured by laser displacement sensor and electric touch probe are achieved directly. Performance of the proposed system is evaluated through measurement of various shape model.

  • PDF

Linear Correlation between Online Capacitance and Offline Biomass Measurement up to High Cell Densities in Escherichia coli Fermentations in a Pilot-Scale Pressurized Bioreactor

  • Knabben, Ingo;Regestein, Lars;Schauf, Julia;Steinbusch, Sven;Buchs, Jochen
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권2호
    • /
    • pp.204-211
    • /
    • 2011
  • To yield high concentrations of protein expressed by genetically modified Escherichia coli, it is important that the bacterial strains are cultivated to high cell density in industrial bioprocesses. Since the expressed target protein is mostly accumulated inside the E. coli cells, the cellular product formation can be directly correlated to the bacterial biomass concentration. The typical way to determine this concentration is to sample offline. Such manual sampling, however, wastes time and is not efficient for acquiring direct feedback to control a fedbatch fermentation. An E. coli K12-derived strain was cultivated to high cell density in a pressurized stirred bioreactor on a pilot scale, by detecting biomass concentration online using a capacitance probe. This E. coli strain was grown in pure minimal medium using two carbon sources (glucose and glycerol). By applying exponential feeding profiles corresponding to a constant specific growth rate, the E. coli culture grew under carbon-limited conditions to minimize overflow metabolites. A high linearity was found between capacitance and biomass concentration, whereby up to 85 g/L dry cell weight was measured. To validate the viability of the culture, the oxygen transfer rate (OTR) was determined online, yielding maximum values of 0.69 mol/l/h and 0.98mol/l/h by using glucose and glycerol as carbon sources, respectively. Consequently, online monitoring of biomass using a capacitance probe provides direct and fast information about the viable E. coli biomass generated under aerobic fermentation conditions at elevated headspace pressures.

초음파를 이용한 CFRP 복합재의 일방향 비파괴 평가 (One-Sided Nondestructive Evaluation of CFRP Composites By Using Ultrasonic Sound)

  • 임광희;장계림;최성록;예창희;류제성;임수환;한민규
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.47-52
    • /
    • 2011
  • It is well known that stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates because the layup of composite laminates influences their properties. Ultrasonic NDE of composite laminates is often based on the backwall echoes of the sample. A pair of such transducers was mounted in a holder in a nose-to-nose fashion to be used as a scanning probe on composites. Miniature potted angle beam transducers were used (Rayleigh waves in steel) on solid laminates of composites. Experiments were performed to understand the behavior of the transducers and the nature of the waves generated in the composite (mode, wave speed, angle of refraction). C-scan images of flaws and impact damage were then produced by combining the pitch-catch probe with a portable manual scanner known as the Generic Scanner ("GenScan"). The pitch-catch signal was found to be more sensitive than normal incidence backwall echo of longitudinal wave to fiber orientation of the CFRP composites, including low level porosity, ply waviness, and cracks. Therefore, it is found that the experimentally Rayleigh wave variation of pitch-catch ultrasonic signal was consistent with numerical results and one-side ultrasonic measurement might be very useful to detect the defects.

어깨의 능동 수축을 동반한 관절가동술이 부리돌기와 위팔뼈 머리 사이의 거리에 미치는 영향 (The Effect of Mobilization Combined with Shoulder Active Contraction of Depth between the Coracoid Process and Humeral Head)

  • 김선민;장상훈
    • 대한정형도수물리치료학회지
    • /
    • 제29권2호
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: This study examined the distance between the coracoid process and the humeral head using an ultrasonography device when shoulder active contraction were applied according to the guided direction in the end range of shoulder mobilization. This study aims to provide essential data on treating shoulder disease patients. Methods: The subjects of this study were 20 adults with healthy shoulder joints. ultrasonography (US) equipment was used to examine shoulder joint mobilization under two conditions: (1) anteroposterior (AP) joint mobilization and (2) superoinferior (SI) joint mobilization. Shoulder active contraction was assessed in the end range. The distance between the coracoid process and the humeral head was measured. A linear probe was used for US; the frequency was set to 7.5MHz, and the US image display method was set to B-mode. The US measurement values were measured in (1) the starting position, (2) the end range position, and (3) the end range position of the shoulder active contraction, and the moving distance was drawn in a straight line through the US image. The distance was determined as the measurement value, and the average values were compared. Reults: The results were as follows: (1) the measured AP Joint mobilization increased by an average of .52cm from the end range of the joint mobilization with shoulder active contraction; (2) the measured SI Joint mobilization increased by an average of .49cm from the end range of the joint. Conclusion: When shoulder mobilization is applied, the distance between the coracoid process and the humeral head increases when muscle contraction occurs through shoulder active contraction in the end range, according to the therapist's guidance. Therefore, shoulder mobilization combined with shoulder active contraction is an effective treatment method for patients with shoulder injuries.

  • PDF

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

계란 할란검사장비의 성능 비교 (Comparison of Egg Testing Devices for Internal Egg Quality Measurements)

  • 김동준;전승엽;김희원;원재선;이재청;이경우
    • 한국가금학회지
    • /
    • 제43권4호
    • /
    • pp.229-233
    • /
    • 2016
  • 본 실험은 국내 외에서 시판 중인 계란검사장비 3종인 레이저형, 탕침형 그리고 초음파형의 성능을 평가하고자 실시하였다. 실험에 사용한 신선란은 단일 계군에서 산란한 특란을 선발하여 사용하였다. 실험 1에서는 동일한 계란을 순차적으로 3종의 장비를 이용하여 분석하였다. 실험 2에서는 동일한 계란을 순차적으로 2종의 장비를 이용하여 분석하였으며, 실험 3에서는 동일한 계군에서 산란한 계란 200씩을 각각의 할란검사장비를 이용하여 난질을 분석하였다. 분석항목으로는 난중, 농후난백높이, 호우유닛 그리고 난황색을 측정하였다. 실험 1과 2에서는 장비에 따른 난중의 차이는 발견되지 않았지만, 농후난백 높이와 호우유닛의 수치가 초음파형에서 가장 높았으며, 그 다음으로 탕침형, 레이저형순으로 조사되었다. 동일한 계군에서 산란한 계란을 각각 할란검사장비를 이용하여 분석한 결과, 난중에서는 차이가 없었지만, 초음파형에서 가장 높은 난백고와 호우유닛을 나타내었다. 하지만 난황색은 레이저형에서 가장 높은 결과를 나타내었다. 결론적으로 신선란을 대상으로 조사한 할란검사장비의 난질평가 결과는 장비에 따른 차이가 있는 것으로 조사되었다. 비록 장비간의 상관계수는 높게 계산되었지만, 동일 계란에 따른 호우유닛 결과는 장비에 따른 편의(bias)와 넓은 신뢰한계를 나타내었다. 이러한 결과는 호우유닛이 높은 신선란을 대상으로 품질을 평가한다면 어떤 장비를 사용하더라도 계란의 품질 등급에는 차이가 없겠지만, 일정기간 저장되어 호우유닛이 떨어진 계란을 대상으로 품질을 평가한다면 장비에 따라서 계란 등급에 차이가 날 수 있는 것을 의미한다. 하지만 본 연구에서는 동일한 계란을 할란 후 순차적으로 측정하여, 난황과 난백 시료 이동에 따른 기계적인 오차를 고려할 수 없기 때문에 향후 이러한 방법을 보완하여 할란검사장비의 성능을 평가할 수 있는 기법의 개발이 필요하겠다.

치은 염증 상태에 따른 치주낭 측정 깊이와 방사선학적 측정 깊이, 외과적 측정 깊이의 비교 연구 (A COMPARATIVE STUDY OF THE PROBING ATTACHMENT LEVEL, RADIOGRAPHIC AND SURGICAL MEASUREMENT ACCORDING TO GINGIVAL INFLAMMATORY CONDITION)

  • 백동훈;채중규;조규성;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제24권2호
    • /
    • pp.261-270
    • /
    • 1994
  • The purpose of this study was to evaluate relationship of probing attachment levels, radiographic measurements and surgical measurements according to gingival inflammatory condition. Patients with incipient to moderate periodontitis were selected. Upper and lower premolar and molar teeth excluding third molars were measured. At first visit, gingival index and bleeding on probing were taken, and subjects were grouped into 4 categories as follows : Experimental group I : gingival index 1 and no bleeding on probing. Experimental group II : gingival index 2 and no bleeding on probing absent. Experimental group III : gingival index 1 and bleeding on probing present. Experimental group IV : gingival index 2 and bleeding on probing present. Probing attachment levels were measured with manual probe on mesial and distal surfaces from cementoenamel junctions to terminal ends of probe. Radiographic measurements were made to assess bone loss by measuring the distance from cementoenamel junction to the alveolar crest. After thorough scating, a flap was raised exposing the alveolar bone and surgical measurements were made from cementoenamel junction to alveolar bone. The results were as follows: 1. Differences between probing attachment level and radiographic measurements showed $1.01{\pm}0.73mm$ for experimental group I, $0.98{\pm}0.48mm$ for experimental group II, $0.59{\pm}0.66mm$ for experimental group III, $0.98{\pm}0.38mm$ for experimental group IV and with no significant difference between groups. 2. Differences between probing attachment level and surgical measurements showed $1.36{\pm}0.80mm$ for experimental group I, $1.47{\pm}0.54mm$ for experimental group II, $1.06{\pm}0.39mm$ for experimental group III, $1.41{\pm}0.40mm$ for experimental group IV and with no significant difference between groups. 3. Differences between surgical and radiographic measurements showed $0.36{\pm}0.48mm$ for experimental group I, $0.51{\pm}0.54mm$ for experimental group II, $0.57{\pm}0.72mm$ for experimental group III, $0.41{\pm}0.49mm$ for experimental group IV and with significant difference between experimental group I and experimental group II, III, IV(P<0.05).

  • PDF

원전 소구경 배관 소켓용접부 위상배열 초음파검사 기술 개발 (Development of the Phased Array Ultrasonic Testing Technique for Nuclear Power Plant's Small Bore Piping Socket Weld)

  • 윤병식;김용식;이정석
    • 비파괴검사학회지
    • /
    • 제33권4호
    • /
    • pp.368-375
    • /
    • 2013
  • 소구경 배관 용접부 손상은 원자력발전소에서 빈번하게 발생되고 있는 문제이며, 이러한 손상은 보수를 위한 불시정지를 야기하고 결과적으로 발전소에 경제적인 손실을 초래한다. 따라서 소켓용접부의 제작결함 검출과 초기 성장 결함의 검출은 매우 중요하다고 할 수 있다. 지금까지 해당부위에 대한 검사는 ASME Code Section XI 요건에 의하여 표면검사를 적용하여 왔으나 강화검사로 체적검사기법인 초음파검사를 병행하여 수행하고 있다. 그러나 가동중에 발생되는 피로균열을 검출하기 위하여 적용되고 있는 일반 수동 초음파검사는 소켓용접부의 접근성과 초음파 탐촉자의 접촉 문제 등으로 인하여 검사 결과의 신뢰성에 문제가 있어 왔다. 본 연구에서는 위상배열 초음파검사 기술을 적용하여 소구경 배관 소켓용접부의 검사 신뢰성과 속도를 향상하고자 하였다. 이를 위하여 소구경 배관 소켓용접부 검사를 위한 3.5 MHz 위상배열 초음파 탐촉자를 제작하고 탐촉자의 접촉 조건과 일정한 신호 품질을 유지하기 위하여 수동 엔코더 스캐너를 개발하였다. 또한 검사 시스템을 구성하고 현장 검사를 위한 절차서도 개발하였다.