• 제목/요약/키워드: Manual Measurement

검색결과 453건 처리시간 0.035초

Utilization of Light Microscopy and FFT for MFA Measurement from Unstained Sections of Red Pine (Pinus Densiflora)

  • Kwon, Ohkyung;Lee, Mi-Rim;Eom, Chang-Deuk
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권5호
    • /
    • pp.399-405
    • /
    • 2013
  • This study demonstrates the utilization of light microscopy and Fast Fourier Transform-Peak Finding (FPF) method for microfibril angle (MFA) measurement from unstained sections of red pine (Pinus densiflora). To obtain an image with optimal contrast and resolution for MFA measurement, effects of numerical aperture (NA) of condenser lens and color filters were investigated. About 60% of NA of the maximum condenser NA produced an image with optimal contrast, but a color filter with short wavelength range (DAPI) created images with improved resolution. Manual angle measurement and the FPF method were applied to the image with optimal contrast for MFA measurement. The experimental results from the FPF method were considered to be more repeatable and less subjective than those from the manual angle measurement.

Next Generation Fiber Length Measurement

  • Tiikkaja, Esa;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • 제32권5호
    • /
    • pp.54-59
    • /
    • 2000
  • The next generation fibre size analyser has been developed in Kajaani based on over 15 years experience in fibre measurement. This new FiberLab-analyser can measure fibre length both along the fibre centre line and as projected. The cross-sectional measurements of fibre are in principle similar to the earlier version FiberLab. Measured data are generally displayed in distributions. Some new calculations have been added, for example the fibres cross sectional area and fibre volume index both available as distributions as well. The performance of the FiberLab measurement is verified against the manual microscopic testing. These tests show that the new image analysis-based measurement well matches with the manual methods.

  • PDF

Evaluation of manual workload in repetitive wrist and finger motion (반복적인 손목 및 손가락 작업에서의 수작업 부하 평가)

  • Gwon, O-Chae;Yun, Myeong-Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • 제18권2호
    • /
    • pp.103-120
    • /
    • 1999
  • The purpose of this study was to evaluate the manual workload in repetitive wrist and finger motion. To evaluate manual workload, angular displacement of the joint, EMG of the muscle and subjective rating were studied. Both wrist motion and finger motion were studied. A screw-driving task was used for the wrist motion experiment. A keyboard typing task was used for the finger motion experiment. All finger joint angles and wrist angles were measured by an angle-measuring glove($CyberGlove^{TM}$, Virtual Technologies, Inc.). Surface EMG was recorded from FCU muscle and FDS muscle simultaneously with the angle measurement. Subjective ratings of exertion were also recorded using the modified Borg's CR-10 scale. Repetition rates of 0.5, 1, 2 motions per second were used with each task. As a result, manual workload increased with increasing repetitiveness. Peak spectral magnitude and frequency components corresponded closely with joint angular displacement amplitudes and repetition rates. Results of the correlation analysis showed that there were significant correlation among EMG, frequency-weighted motion and subjective measurement. Both EMG and frequency-weighted filtering showed consistent workload estimation with increasing task frequency. Subjective ratings showed slight over-estimation of the workload as the task frequency is increased.

  • PDF

Comparison of Field Monitoring System in case of Automatic and Manual Type Executed in Urban Deep Excavation Site (도심지 대규모 굴착공사에서 수행된 자동계측과 수동계측의 비교 사례)

  • Kim, Tae-Seob;Chung, Won-Hong;Kim, Hyun-Mo;Kim, Woong-Kyu;Jung, Chang-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1216-1223
    • /
    • 2008
  • Displacement control of earth retaining wall is recognized as the most important item for insuring the stability of ground in urban deep excavation site near by major structure such as subway etc. The field monitoring system is classified by two types as manual system and automatic system. The application case of latter type of field monitoring is increased because real time measurement is possible in automatic system and that is correspondent with the recent constructional trend. Though the automatic monitoring system is more useful and advanced than manual monitoring system, accuracy of the system is not verified sufficiently. It was examined that the reliance of automatic monitoring system in this paper through the comparison of monitoring result obtained three urban excavation site in which the each type of monitoring system was executed concurrently. Result of the examination is that the two types of monitoring system is generally alike in view of monitoring result, so the engineering reliance of automatic system was confirmed in case site. This task was researched in restricted case site, it is expected more precise analysis from security of more data monitored and progressive study.

  • PDF

A Comprehensive Analysis of 3D Body Scanning vs. Manual Measurements in a Large-Scale Anthropometric Survey -Insights from the 8th Size Korea Project- (대규모 인체치수조사 사업에서 3차원 측정치와 직접측정치의 차이 분석 -제8차 사이즈코리아 사업을 중심으로-)

  • Sunmi Park
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제48권2호
    • /
    • pp.233-253
    • /
    • 2024
  • This study analyzed differences between three-dimensional (3D) body scanning and manual measurements, aiming to assess whether 3D scanning can replace traditional anthropometric tools, such as tape measures and calipers. Data from 4,478 participants in the 8th Size Korea Project were analyzed, covering 43 measurement items. Since Given that the 3D and manual measurements were performed on the same subjects in the 8th Size Korea Project, it was possible to determine the correlation more accurately between the two measurement methods more accurately. Using Applying ISO 20685-1(2018) standards, 15 out of the 43 items fell within allowable error limits. When classified into six types, "small circumferences" and "segment lengths" showed averages of 3.35 mm and 3.10 mm, respectively, within acceptable range. "Body heights" and "body depths" slightly exceeded the limit, with averages of 5.28 mm and 6.58 mm. "Body widths" and "large circumferences" surpassed the limit, with means of 16.77 mm and 16.18 mm. The study offers an objective basis to for validate validating 3D measurements' measurements' reliability and accuracy, addressing various industries' needs for information on the human body's dimensions information.

Systematic Review of the Diagnosis of Pelvic Deviation for Chuna Manual Therapy (추나치료에 적용된 골반변위 진단법에 대한 체계적 문헌고찰)

  • Lee, Jun-Seok;Park, Kyeong-Won;Kim, Hyun-Tae;Park, Sun-Young;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • 제32권2호
    • /
    • pp.83-94
    • /
    • 2022
  • Objectives This systematic review aimed to analyze research about pelvic deviation diagnosis for Chuna manual therapy (CMT) and to review the diagnosis methods, indices, and results of diagnosis. Methods Ten electronic databases were systematically searched up to January 4th 2022. Clinical studies and reviews containing pelvic deviation diagnosis for CMT or using CMT as a treatment of pelvic deviation were selected and evaluated. CMT diagnosis in clinical studies and reviews were isolated and analyzed by 2 independent reviewers. Results Thirteen clinical studies and three reviews were included in the evaluation. X-ray analysis and manual testing were the two main methods used in CMT diagnosis of pelvic deviation. For manual testing in clinical studies, leg length insufficiency testing was the most frequently used measurement index and the most common diagnostic results were anterior and posterior rotation. In the X-ray analysis, Obturator foramen and femur head line were the most frequently used measurement index and the most common diagnostic results were anterior rotation and posterior rotation. Conclusions The systematic review found that manual testing and X-ray analysis were mainly used for the diagnosis of pelvic deviation in CMT among clincial and review articles. As there was little research about diagnosing pelvic deviation in CMT and any existing research presented only low standards of evidence, further research should be updated with using a more standardized approach.

Development of Diagnostic System for Winding Profile Abnormality of Hot Coils (열연코일 권취형상 불량 자동진단 시스템 개발)

  • Lee, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.590-595
    • /
    • 2000
  • On the contrary to the increasing needs of shape qualities, most of quality inspections are carried out by manual or operator's insight. To find the causes of shape inferiority, it is required to gather and analyze the shape measurement data. As a result the winding profile measurement system ($TELE-SCANNER^{(R)}$) is developed to analyze the coiling process and automate the manual measuring process for winding profile of hot-rolled coils. The winding profile measurement system measures and analyzes winding profile shapes of hot-rolled coils, and classifies them into several dominant patterns that are related to normal or abnormal mechanical conditions of down-coiler. The system also contains analysis software to quantify the winding profile shapes and patterns, and to produce statistics to help search the causes of profile shape inferiority.

  • PDF

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • 제22권4호
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

Effects of Manual Therapy Approach for Lumbar Spondylolisthesis (요추부 전방전위증 환자의 도수치료 효과 연구)

  • Kang, Seok-Yeong;Kim, Myung-Joon;Lee, So-Hee
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • 제16권2호
    • /
    • pp.34-39
    • /
    • 2010
  • Purpose : The purpose of this study is to find out the evidence concerning the effectiveness of manual therapy intervention in the treatment of low back pain related to spondylolisthesis Methods : 12men with lumbar pain from L5~S1 spondylolisthesis of 2 or 3 grade were treated during 12-week period. The manual therapy applied twice per week. The results of back and radiating pain were measured by VAS, and abdominal muscle strength was measured by Power track II. The measurement of degree of slip in spondylolisthesis was confirmed by the lateral view of X-ray and took a measurements of the anterior displacement of a vertebral body in relation to the vertebral below. Results : 1. There was significant decrease in the back and radiating pain.(p<0.05) 2. There was significant increase in the abdominal muscle strength.(p<0.05). 3. There was significant decrease in the degree of the anterior displacement. Conclusion: The intervention of manual therapy for lumbar spondylolisthesis is effective in back pain, radiating pain, abdominal muscle strength and degree of the anterior displacement. So, nonsurgical treatment should be attempted before surgical treatment.

  • PDF

Comparative Assessment of Virtual Garments using Direct and Manual Avatars (가상아바타에 따른 가상의복의 비교평가)

  • Lim, Ho-Sun;Istook, Cynthia L.
    • The Research Journal of the Costume Culture
    • /
    • 제19권6호
    • /
    • pp.1359-1371
    • /
    • 2011
  • The purpose of this paper is to compare two avatars made using direct and manual methods and to evaluate the fit and appearance of two virtual garments on the direct and manual avatars. In this study, two subjects were measured by $[TC]^2$ body scanner and the avatars and virtual garments were created by OptiTex software. The direct avatar was made by the direct importation of 3D body scan data and the manual avatar was made by manual input from extracted body measurement. Two virtual garments in a tank-top were evaluated by distance, transparency, and stretch maps. In the results of comparing difference of the direct and manual avatars, the bust and back of the manual avatar are protruded slightly more than that of the direct avatar and the manual avatar is slightly larger dimensions at the bust, waist, abdomen, and hip area in the side view in case of subject 1 and 2. In the results of comparing difference of the fit and appearance of two virtual garments on the direct and manual avatars, in case of subject 1 and 2, the back of the virtual garment on the manual avatar are protruded more than that of the direct avatar. Also, the ease in the bust area of the virtual garment on the manual avatar with a projected bust area was smaller than that of the virtual garment on the direct avatar and the stretch of that of the manual avatar was also high in the bust area. The results of this study are expected to be used as basic information in the apparel industry using virtual try-on technology.