• Title/Summary/Keyword: Manikin

Search Result 147, Processing Time 0.02 seconds

Computer Simulation for Calculation of Thermal Insulation in Korean Folk Clothes (한복의 보온력 평가를 위한 컴퓨터 시뮬레이션)

  • 권오경;성수광
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1153-1161
    • /
    • 1997
  • The insulation provided by clothing system is usually expressed in terms of a coo units and its distribution of the body, directly affect convective, conductive, and radiant heat loss from the skin to the environment Evaporated heat loss is dependent upon fabric permeability, the amount of body surface area covered by clothing, and the pumping of air between the body and garment layers. Persons at low to medium activity levels, dressed in conventional apparel in door environments, usually do not lose a large amount of heat through evaporation. Thermal manikin technology is used to measure the resistance to heat transfer provided by clothing systems. The reciprocal of this value, 6.45 W/m2.$^{\circ}C$ is often used in calculations for convenience. The purpose of this study was to implement a research program for calculation the insulation value (clo), body surface area and basal metabolic rate of selected clothing system. The project provided for the building of an insulation data base for use in evaluating and comparing new and improved garments.

  • PDF

Assessment of Clothing Ventilation through Openings (개구부를 통한 의복의 환기 양상 평가)

  • 추미선
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.5
    • /
    • pp.660-667
    • /
    • 2000
  • Clothing ventilation was investigated using a manikin wearing an impermeable overall under an isothermal condition, in which the ventilation occurred only through the openings. The ventilation volume was estimated by both microenvironment volume and ventilation rate, where, the microenvironment volume was measured by an air subsitution method and the ventilation rate by a trace gas method. Microenvironment volume of the experimental garment was about 21.0 liters. Even though it was certainly affected by the distance from the opening, the ventilation rate was more significantly influenced by the opening area and the shape of air layer in the clothing. The volume of air exchange in the clothing microenvironment was affected greatly by the microenvironment volume and the opening area, and it was different for each part of the body with bigger air exchange volume in the microenvironment of the leg as compared to that of the arm.

  • PDF

Augmented Reality Technology-based Dental Radiography Simulator for Preclinical Training and Education on Dental Anatomy

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.4
    • /
    • pp.274-278
    • /
    • 2019
  • It is important that students are provided opportunities to practice their skills in acquiring radiographic images. However, these opportunities are currently limited because of the risk of radiation exposure. To overcome this limitation, a new augmented reality-based radiography simulator was developed that enables students to practice radiographic techniques as part of self-directed learning without time and space constraints. Subsequently, cross-sectional images of a manikin phantom head obtained via computed tomography were reconstructed into a three-dimensional object. An image marker that could be recognized by a mobile device and could allow users to practice dental radiography techniques was devised. The three-dimensional object was augmented to the mobile device; consequently, among 106 stored dental radiographs on the device, a radiograph corresponding to specific imaging conditions was opened when users performed radiographic procedures. This technology could improve dental students' understanding of dental anatomy and contribute to improving their competency in acquiring dental radiographs.

Development of the sunshade hat with a large brim(Part I) -Development and test with manikins- (양산형 일광차단모의 개발(제1보) -고안 및 마네킹 착용실험-)

  • 김경수;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.8
    • /
    • pp.1177-1185
    • /
    • 2002
  • This study was to develop the sunshade hat which reduced stress from solar radiation and ultraviolet radiation (UV), in order to keep the farmer's health and to promote their work efficiency. The new sunshade hat with a large brim, special structure for ventilation, stability and portability was designed and tested with manikin heads outdoors. Two newly designed sunshade hats(A, B) and three existing hat were tested Sunshade hat A made of double fabric with aluminum coating-nylon and black cotton cloth with a polyester mix(T/C) was the most protective from solar radiation. Sunshade hat B with larger brim was the most protective from ultraviolet radiation, even though it was made of aluminum coating-nylon single fabric.

Comparison of endotracheal intubation speed and ease by using the supraglottic airway laryngopharyngeal tube: A manikin study (성문위기도기 인후두튜브(SALT)를 이용한 기관내삽관 신속성과 용이성 비교: 마네킨을 이용한 연구)

  • Yun, Seong-Woo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.2
    • /
    • pp.29-38
    • /
    • 2015
  • Purpose: The purpose of this study was to improve airway management ability by comparing the speed, angle of the neck, and confidence and ease of supraglottic airway laryngopharyngeal tube (SALT) and endotracheal intubation via direct laryngoscopy. Methods: The subjects of this experimental research study with a randomized crossover design were 44 emergency medicine technician - paramedics working in the fire department of 'J' - do. SPSS version 19.0 was used in the statistical analysis. Results: Speed and angle of the neck (p<.001), as well as confidence and ease (p<.001), showed significant differences between endotracheal intubation with a SALT and endotracheal intubation via direct laryngoscopy. Conclusion: If endotracheal intubation via direct laryngoscopy is difficult to use or in trauma patients, using a SALT is safe and enables fast intubation. Moreover, in order to improve the efficiency of advanced airway management, the application of SALT should be introduced in the domestic scene.

Numerical Calculations of IASCC Test Worker Exposure using Process Simulations (공정 시뮬레이션을 이용한 조사유기응력부식균열 시험 작업자 피폭량의 전산 해석에 관한 연구)

  • Chang, Kyu-Ho;Kim, Hae-Woong;Kim, Chang-Kyu;Park, Kwang-Soo;Kwak, Dae-In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.803-811
    • /
    • 2021
  • In this study, the exposure amount of IASCC test worker was evaluated by applying the process simulation technology. Using DELMIA Version 5, a commercial process simulation code, IASCC test facility, hot cells, and workers were prepared, and IASCC test activities were implemented, and the cumulative exposure of workers passing through the dose-distributed space could be evaluated through user coding. In order to simulate behavior of workers, human manikins with a degree of freedom of 200 or more imitating the human musculoskeletal system were applied. In order to calculate the worker's exposure, the coordinates, start time, and retention period for each posture were extracted by accessing the sub-information of the human manikin task, and the cumulative exposure was calculated by multiplying the spatial dose value by the posture retention time. The spatial dose for the exposure evaluation was calculated using MCNP6 Version 1.0, and the calculated spatial dose was embedded into the process simulation domain. As a result of comparing and analyzing the results of exposure evaluation by process simulation and typical exposure evaluation, the annual exposure to daily test work in the regular entrance was predicted at similar levels, 0.388 mSv/year and 1.334 mSv/year, respectively. Exposure assessment was also performed on special tasks performed in areas with high spatial doses, and tasks with high exposure could be easily identified, and work improvement plans could be derived intuitively through human manikin posture and spatial dose visualization of the tasks.

A Study on the Comfort and Skin Temperature on the Clothing Environment in the Taegu City during Years -Concentrated on indoor uniforms- (섬유·패션 산업 DB 구축을 위한 대구지역의 연간 피복환경내의 피부온과 쾌적성 -실내 제복을 중심으로-)

  • Ryo, Duck-Hwan;Lee, Uk-Ja;Kim, Seong-Jin;Song, Min-Kyo;Cho, Ji-Hyun;Jung, Meung-Sun
    • Fashion & Textile Research Journal
    • /
    • v.1 no.4
    • /
    • pp.376-386
    • /
    • 1999
  • The purpose of this study was to determine the physiological responses and the Subjective sensations of the human subjects when 10 human subjects(5 males and 5 females) were tested with selected ensembles, including the uniforms of students, industrial and bank workers. For the study, garment material and design were selected, which was mostly used in Taegu area by the survey. Thermal manikin and the human subject tests were performed. The results were as follows: 1. There was no significant difference among skin temperature of head by season and among that of breast and back by all variables, however, there was a significant difference among that of belly by gender and that of thigh and shank by season. In addition, there was no significant difference among rectal temperature by gender and season, but there was a significant difference by uniform. 2. Mean skin temperature of male subjects was significantly higher than that of female subjects. Specially in lower environmental condition, the difference got larger. 3. There was a significant difference among purse rate of subjects by uniform, but there was no significant difference among those by gender and season. There were no significant difference among maximum and minimum blood pressure by gender, uniform, and season. 4. There was a significant difference in temperature of chest among gender and uniform, and there was no significant difference in temperature of back by season. In addition, There was a significant difference in humidity of back by uniform and season but there were no significant difference in that by gender. 5. There was a significant difference in humidity sensation by gender, comfort sensation by uniform and season, but there was no significant difference thermal sensation by uniform and season. 6. For the result of regression analysis, we got the regression equations as follows: Clo=1.810 Thickness+0.525, Clo=0.475 weight+0.863.

  • PDF

Comfort Properties of Ski Wear Using Vapor-Permeable Water Repellent Fabrics and Thermal Insulation Battings (투습발수직물과 축열보온섬유를 이용한 스키웨어의 쾌적감)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.245-254
    • /
    • 1992
  • The purpose of this study was to evaluate the mechanical thermal resistances and comfort properties of ski wear made with vapor-permeable water repellent (VPWR) fabrics and thermal insulation battings. Four types of experimental clothing were made with the combination of two VPWR fabrics (Hipora-$TM^{\circledR}$, Hipora-$CR^{\circledR}$) and two thermal insulation battings ($Viwarm^{\circledR},\;Airseal^{\circledR}$). Thermal resistances of ski wear were objectly evaluated by thermal manikin experiment ($21{\pm}\;2^{\circ}C,\;50{\pm}5\%$ R.H.,0.25 m/sec air velocity) and thermographic accessment ($2{\pm}2^{\circ}C,\;0\%$ R.H.,0.25 m/sec air velocity, and emissivity level : 1). Garment wear tests of ski wear included the measurement of the microclimate (inner temp. and relative humidity) of the experimental clothing by digital thermohygrometer and subject wear sensation using McNall's thermal comfort ratings. CBo values of experimental clothing 4 (Hipora-$CR^{\circledR}+Airseal^{\circledR}$) and 1 (Hipora-$TM^{\circledR}+Viwarm^{\circledR}$) were significantly higher than those of 2 (Hipora-$TM^{\circledR}+Airseal^{\circledR}$) and 3 (Hipora-$CR^{\circledR}+Viwarm^{\circledR}$). Thermal resistances in the points of breast, back, belly, and loin was significantly higher than those of upper am, fore arm, and shank of measuring points on the thermal manikin. According to the color map of the thermogram, the experimental clothing 4 indicated higher surface temperatures than the others showing more yellowish spots on the surface of clothing. Inner temperature of experimental clothing was not significantly different among the four types of ski wear, but relative humidities of experimental clothing were significantly different. Relative humidities of experimental clothing 1 and 3 showed higher than those of 2 and 4. Relative humidity of experimantal clothing was affected largely by the thermal resis- tance of thermal insulation batting materials. The subject wear sensation of experimental clothing 2 and 4 showed lower humidity than the others. Subject wear sensation was affected more by humidity sensation than by thermal sensation.

  • PDF

Relationship between Thermal Insulation and the Combinations of Korean Women's Clothing by Season - Using a Thermal Manikin - (한국 성인 여성의 계절별 의복조합과 보온력과의 관련성 - 써멀마네킨 실험에 의한 -)

  • Choi, Jeong-Wha;Ko, Eun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.966-973
    • /
    • 2007
  • The purpose of this study was to examine the correlation between the combination of women's clothing by season and thermal insulation using a thermal manikin. A total of 34 kinds of clothing ensembles were selected based on previous studies(8 types for spring/fall, 7 types for summer, and 19 types for winter). The results were as follows: The thermal insulation of clothing ensembles($I_{cle-total}$) ranged from $0.34{\sim}0.60clo$ for spring/fall, $0.16{\sim}0.37clo$ for summer, and $0.89{\sim}1.35clo$ for winter. The correlation coefficient between the thermal insulation of clothing ensembles and thermal insulation accumulated by the individual garments composing of the clothing ensembles($I_{cle-summed}$) was 0.982(p<0.001). The correlation coefficient between the thermal insulation of clothing ensembles and total clothing layers for the upper body part was 0.750 (p<0.001), for the total clothing weight was 0.978(p<0.001), and for the covering area was 0.776(p<0.001). In conclusion, $I_{cle-total}$ showed higher relationships to the $I_{cle-summed}$ and total clothing weight than to the total clothing layers or surface area covered by clothing.

Efficacy and Usability of Patient Isolation Transport Module for CBRN Disaster : A Manikin Simulation Study (특수재난 대응 환자 격리 이송 장비의 효율성 및 편의성 평가: 마네킹시뮬레이션 연구)

  • Kim, Ki-Hong;Hong, Ki-Jeong;Haam, Seung-Hee;Choi, Jin-Woo
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • In Chemical, Biological, Radiological and Nuclear (CBRN) disaster, integrated and optimized equipment package including stretcher, isolation unit, patient monitoring and treatment equipment is essential to achieve proper treatment and prevent secondary contamination. The purpose of this study was to evaluate the efficiency and ease of use of integrated CBRN disaster equipment package for disaster medical response. This study was a randomized crossover study using a manikin simulation for emergency medical technitian (EMT). All participants used the existing devices and prototype of integrated CBRN disaster equipment package alternately. Efficiency was measured by time from vital sign change to detection or treatment application. Ease was use was measured by questionnaires for each patient monitor, stretcher care and isolation unit. 12 EMTs were enrolled. hypoxia-detection time of integrated equipment group was significantly shorter than existing equipment group (4.9 s (3.8-3.9) vs 3.5 s (2.5-3.9), p < 0.05). There was decreasing tendency of ECG change detection and facial mask oxygen supply but no statistical significance was observed. Overall satisfaction of patient monitoring device in integrated equipment group was significantly higher than existing devices (4(3.5-5) vs 3(3-3), p < 0.05). The use of integrated CBRN disaster equipment package shortened the hypoxia detection time and improved usability of vital sign monitor compared to existing devices.