• Title/Summary/Keyword: Mandibular Reconstruction

Search Result 218, Processing Time 0.022 seconds

EFFECTS OF ADMINISTRATION PLATELET RICH PLASMA ON THE DISTRACTED MANDIBLE IN RABBITS (가토에서 신장된 하악골에 대한 혈소판농축혈장의 효과)

  • Bae, Kum-Hyu;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.4
    • /
    • pp.315-323
    • /
    • 2005
  • For reconstruction of the bony defect, distraction osteogenesis has many advantages in comparison with bone graft. However, it needs long consolidation period for sufficient bone maturity. This study is performed to evaluate the effect of PRP injection into the distracted mandible on bone formation in rabbits. Twelve house rabbits, weighing 2 kg, were used. All animals underwent bilateral mandibular osteotomy under general anesthesia. A internal distractor divice was positioned along a plane perpendicular to the line of osteotomy. After 5 days of latency period, distraction osteogenesis was started at a rate of 1 mm/day for 9 days which was distracted 9 mm totally. After completion of distraction, 0.5 ml of PRP which collected in rabbit blood was injected into the distracted mandible on experimental group, whereas no injection was done in control group. Macroscopical, radiographical, and histological, and histomorphometric examinations were performed 2, 4 and 8 weeks after distraction. All animals showed distracted mandible and severe anterior cross-bite. In radiographical findings 2 weeks after distraction, more radiopacity in the distracted gap was found in experimental group than that of control group. At 4 weeks after distraction, distracted bone was similar to normal bone in experimental group. In histological findings, 1) At 2 weeks after distraction, number of osteoblasts and angiogenesis in the distracted gap was found in experimental group than that of control group. 2) At 4 weeks after distraction, more active and distinct bone in the distracted gap was found in experimental group than that of control groups. 3) At 8 weeks after distraction, more dense and matured lamellated bone in the distracted gap was found in experimental group than that of control group. In histomorphometrical findings 8 weeks after distraction, more bone formation was observed in experimental group than control group (p<0.01). These results indicate that administration of PRP into the distracted mandible can promote bone formation.

An Experimental Study of the Healing Process on Several Heterogenous Bone Grafts in Rabbit Mandible;Histologic and Biometric study (가토(家兎) 상악골(上顎骨) 결손부(缺損部)에 수종(數種)의 이종골(異種骨) 이식후(移植後) 치유과정(治癒過程)에 관(關)한 연구(硏究))

  • Oh, Hee-Kyun;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.117-129
    • /
    • 1989
  • The commercial availability of processed heterogenous bone has provided the surgeons with almost unlimited supply, avoidance of additional operation and prevention of the postoperative complications. In addition to these merits, unnecessary bone bank, easy availibility and storage have been achieved. The purpose of this study was to compare and examine the healing capacity of Kiel bone, Pyrost and Osteovit which used as the processed heterografts for the reconstruction of bony defect. Twenty rabbits weighing about 1.7-2.0 Kg were selected and divided into two groups. In experimental group A, the left mandibular defect was allowed to fill with blood, and the right defect was filled with Kiel bone. In experimental group B, the left defect was grafted with Pyrost, and the right with Osteovit. The experimental animals were sacrified after 1, 2, 4 and 8 weeks and the grafted site was studied histologically. To evaluate the strength of healed bone, 2 rabbits from each experimental group and a nonoperated control were sacrified at the 6th week after implantation and used for biometric testing on universal testing machine. The results obtained were as follows : 1. It was considered that these heterogenous bone grafts has feeble or absent immunogenicity since all of them appeared to evoke little inflammatory or forign body reaction. 2. In all experimental groups, new bone formation began from the adjacent region of host bone and extended progressively into the defect sites. New bone was partly formed within the intertrabecular space of the implant and gradually united with the bone that formed at the margin of the host bone. 3. With Pyrost bone formation was rapid and prominent comparing with other graft materials. 4. Osteovit was begun to be absorbed from 2 weeks, and Kiel bone from 4 weeks, however Pyrost was remained to be intact until the end of 8 weeks. 5. As the results of tensile test, the mean values of maximum tensile stress were 1.11${\uparrow}$ $Kgf/mm^{2}$ in Pyrost implanted specimens, 0.85 $Kgf/mm^{2}$ in Osteovit, 0.42 $Kgf/mm^{2}$ in Kiel bone, 0.66 $Kgf/mm^{2}$ in blood filled specimens and 1..13 $Kgf/mm^{2}$ in control. These results indicate that heterogenous bones grafted have little antigenicity to the host tissue, and that they mediate effectively osteoconduction by providing the scaffold for the bone formation. Pyrost and Osteovit appeared to be suitable for the clinical use.

  • PDF

Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report (Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례)

  • Hong, Jun-Tae;Choi, Yu-Sung;Han, Se-Jin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.253-268
    • /
    • 2012
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption, since this includes the gingival area and restricts the position of the implants. however, hard- and soft-tissue grafting may allow the implants to be placed into the desired position. Although it is possible to regenerate lost tissues, an alternative is to use fixed detachable prostheses that restore the function and the esthetics of the gingiva and teeth. Various material combinations including metal/acrylic, metal/ceramic, and zirconia/ceramic have been used for constructing this type of restoration. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. With virtually unbreakable, chip-proof, life-like nature, monolithic zirconia frameworks can prospectively replace other framework materials. This clinical report describes the restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with dental implants. The occluding surfaces were made of monolithic zirconia, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

FIBRIN SEALANTS IN MAXILLOFACIAL SURGERY : A INTRODUCTORY REPORT (악안면 외과 영역에서의 FIBRIN SEALANTS 의 이용)

  • Kim, Myung-Jin;Park, Hyung-Kook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.2
    • /
    • pp.129-136
    • /
    • 1991
  • The fibrin sealant was first designed as an alternative to surgical suture for the purpose of surface-to-surface union especially in parenchymal organs like the liver, spleen and kidney. The clinical application of currently used fibrin sealant was first introduced in 1972. The fibrin sealant consists of principal two components; lyophilized human fibrinogen and bovine thrombin. The fibrinogen component also contains coagulation factor XIII. A solution of aprotinin, an inhibitor of fibrinolysis is used to dissolve the fibrinogen and to provide the first component, and a solution of calcium chloride is also used to provide the second component. From July to December in 1990, during 6 months, we used fibrin sealant in the 28 patients of 33 various cases, in the following ways; supportive application of fibrin sealant after free autogenouse nerve graft for the repair of inferior alveolar nerve, facial nerve or accessory nerve, treament of hemangioma or lymphangioma to thrombosize and lead to the tumor shrinking, skin grafting to stimulate the adhesion and tissue repair, bone grafting in the patients of cleft alveolus, mandibular reconstruction or orthognathic surgery to facilitate the knitting of bone chips, tissue adhesion after tumor resection, radical neck dissection or flap reconstructions, and supportive adhesion of external auditory cannal after TMJ surgery via postauricular approach. No adverse effects were observed, none of the patients developed hepatitis or other blood transmitted disease, and the wound healing were acceptable.

  • PDF

Hyoid Bone Fracture Associated with Hypoglossal Nerve Palsy: A Case Report (설하신경마비를 동반한 설골골절: 증례보고)

  • Kim, Sin-Rak;Park, Jin-Hyung;Han, Yea-Sik
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.199-202
    • /
    • 2011
  • Purpose: Hyoid bone is a U-shaped bone in the anterior of the neck. Hyoid bone fractures are exceedingly rare and represent only 0.002% of all fractures because of its protective position relative to the mandible and its suspension by elastic musculature. We report a patient who presented hyoid bone fracture associated with hypoglossal nerve palsy. We also discuss the possible complication and treatment. Methods: A 69-year-old man was transferred from another institution because of persistent purulent discharge from the left chin. He had a history of trauma in which a knuckle crane grabbed his face and neck in the construction site. A CT scan at the time of the accident demonstrated a comminuted fracture of the right side of the mandible and hyoid bone fracture at the junction between body and right greater cornua. The displaced fracture of hyoid bone and fullness in the pre-epiglottic space were noted, probably indicating some edema. The patient was transferred into ICU after treatment of emergency tracheostomy because the patient showed respiratory distress rapidly. When the patient was hospitalized in our emergency room, he complained of dysphagia and pain when swallowing. On examination of oral cavity, the presence of muscle wasting with fasciculation of the tongue was noted and the tongue deviates to the left side on protruding from the mouth. Pharyngolarygoscopy was performed to make sure that there was no evidence of progressive swelling and pharyngeal laceration. Results: The patient underwent surgical removal of dead and infected tissue from the wound and reconstruction of mandibular bony defect by iliac bone grafting. Hyoid bone fracture was managed conservatively with oral analgesics, soft diet and restricted movement. Hypoglossal nerve palsy was resolved within 7 weeks after trauma without complications. Conclusion: Closed hyoid bone fracture is usually uncomplicated and thus it can be treated conservatively. Surgical intervention for hyoid bone fracture is recommended for patient with airway compromise, pharyngeal perforation and painful symptoms which show no response to conservative care. Furthermore, since respiratory distress syndrome may develop quickly, close observation is required. Besides, hypoglossal nerve palsy is a rarely recognized complication of hyoid bone fracture.

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

Relationship between inter-condylar width and inter-maxillary first molar width (과두간 폭경과 상악 제1대구치간 폭경 사이의 관계)

  • Oh, Sang-Chun;Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.214-219
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the correlation between inter-condylar width and inter-maxillary first molar width to present the criteria for prosthetic reconstruction of dental arch width in maxillary and mandibular fully edentulous patients. Materials and Methods: 120 Koreans (60 males and 60 females) who underwent the cone beam computerized tomography (Cone-beam CT) were selected. The Cone-beam CT images were analysed using Invivo 5.1. After reorientation of axis, inter-maxillary first molar width was measured by clicking both mesio-buccal cusp tip of maxillary first molar. And inter-condylar width was measured by clicking both middle points of condyles. The collected data were analysed with SPSS Version 20.0 and statistical significance of the correlation between inter-condylar width and inter-maxillary first molar width was verified by Pearson's correlation analysis. Results: The mean inter-condylar width of Korean was 105.9 mm, and that of male (108.3 mm) was statistically significantly wider than the female (103.4 mm). The inter-maxillary first molar width of Korean was 57.1 mm, and that of male (57.9 mm) was statistically significantly wider than the female (56.2 mm). Pearson's correlation analysis between inter-condylar width and inter-maxillary first molar width showed a Pearson correlation coefficient of 0.614 and statistically significantly positive correlation. Conclusion: Intercondylar width and inter-maxillary first molar width showed positive correlation and the average ratio of inter-condylar with and inter-maxillary first molar width was 1:0.54. Based on the results of this limited study, inter-condylar width can be used as a guide for setting up dental arch width in fully edentulous patient.