• 제목/요약/키워드: Malfunction

검색결과 927건 처리시간 0.023초

EPD 신호검출에 의한 플라즈마식각공정의 이상검출 (Malfunction detection in plasma etching process using EPD signal trace)

  • 이종민;차상엽;최순혁;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1360-1363
    • /
    • 1996
  • EPD(End Point Detection) is used to decide etching degree of layer which must be removed at wafer etching process in plasma etching process which is one of the most important process in semiconductor manufacturing. In this thesis, the method which detects malfunction of etching process in real-time will be discussed. Several EPD signal traces are collected in normal plasma etching condition and used as reference EPD signal traces. Critical points can be detected by applying differentiation and zero-crossing techniques to reference EPD signal. Mean and standard deviation of critical parameters which is memorized from reference EPD signal are calculated and these determine the lower and higher limit of control chart. And by applying statical control chart to EPD signals which are collected in real etching process malfunctions of process are detected in real-time. By means of applying this method to the real etching process we prove our method can accurately detect the malfunction of etching process and can compensate disadvantage of current industrial method.

  • PDF

뉴럴 네트웍과 지식 기반 퍼지 추론을 이용한 디젤기관 고장진단 시스템에 관한 연구 (A study on the fault and diagnosis system for diesel engine using neural network and knowledge based fuzzy inference)

  • 천행춘;김영일;김경엽;안순영;오현경;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.233-238
    • /
    • 2002
  • This paper propose the construction of fault diagnosis engine for diesel generator engine and rule inference method to induce rule for fuzzy inference from the monitored data of diesel engine. The proposed fault diagnosis system is constructed the Malfunction Diagnosis Engine(MDE) and Hierarchy of Malfunction Hypotheses(HME), It is Proposed the rule reduction method of knowledge base for concerning data among the various analog data.

  • PDF

Research on the Correlation of Control Malfunction with Induced Voltage of Control Signal Line According to Voltage Change of a Power Line

  • Kang, Dong-Woo;Kim, In-Gun;Ham, Sang-Hwan;Kim, Sung-Yul;Bae, Sungwoo;Kim, Dae-Nyeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.775-780
    • /
    • 2016
  • This induced voltage measurement test and electromagnetic field simulation are related to the possibility of control signal malfunction by power line. Through an experiment, this research analyzed whether the voltage causing control malfunction according to the on/off status of power permitted to power line was induced to control signal line. Also, the research calculated the voltage induced to control signal line and examined the phenomenon by conducting an electro-magnetic field-specific simulation through the finite element method for the cable model used in the experiment.

고무차륜 AGT 경량전철 차량의 고장관리 계획 (Failure Management Plan of the Rubber-Tired AGT Light Rail Vehicle)

  • 김연수;박성혁;이안호;한석윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.139-144
    • /
    • 2003
  • This study was aimed to establish failure management plan of the rubber-tired AGT light rail vehicle for its safety case, which was developed according to the Korean standardized specifications for the light rail vehicle. Vehicular 9 failure modes anticipated during the system operation were considered, which are single malfunction of redundant equipment, malfunction of train radio, public address and air compressor, battery, main circuit NFB trip, on-board ATO control device malfunction, on-board ATP control device malfunction, fail of brake release, flat tire, train emergency door open.

  • PDF

자가용 수용가에서 배선용 및 누전차단기 오동작에 대한 조사연구 (Survey on the Malfunction of MCCB and ELB in Private Electrical Facilities)

  • 유재근;이상익;전정채
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.87-93
    • /
    • 2005
  • 최근 수용가의 부하회로 및 설비가 복잡해짐에 따라 배선용 및 누전차단기의 원인모를 동작 또는 오동작이 증가하고 있지만 오동작에 대한 실태조사는 이루어지지 못하였다. 본 논문에서는 218개소 자가용 수용가의 전기안전 관리자를 대상으로 설문조사를 실시하여 배선용 및 누전차단기의 오동작 원인과 그 영향에 대해 조사하였다. 조사결과 배선용 및 누전차단기 사용 장소의 $70[\%]$ 이상이 오동작을 경험하고 있고 오동작 원인은 노후화($25(\%)$ 이상), 원인불명($22(\%)$ 이상), 제품불량($20(\%)$ 이상), 고조파와 같은 이상전원($20(\%)$ 이상), 기타($9(\%)$ 순으로 나타났다. 또한 오동작로 인한 피해는 제품생산 차질, 기기고장, 정보손실, 업무 및 조업중단, 기타 순으로 조사되었다. 본 연구결과는 현장에서 배선용 및 누전차단기의 오동작 원인을 분석할 때 참고자료로 활용될 수 있을 것이다.

뇌임펄스전압에 대한 30[A]용 고감도형 누전 차단기의 오동작에 대한 특성의 해석 (Analysis of Malfunction Characteristics of High Sensitivity Type Earth Leakage Circuit Breaker for 30[A] due to Lightning Impulse Voltages)

  • 이복희;이승칠;김찬오
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.96-103
    • /
    • 1997
  • 본 논문은 뇌임펄스전압에 대한 누전 차단기의 오동작 특성에 관한 것으로 한국공업규격 KS C 4613의 규정과 서지보호장치를 갖는 모의회로의 조건에서 누전차단기의 부동작 특성을 실험적으로 조사하고 검토하였다. 실험 결과, 본 연구에 사용한 30[A]용 고감도형 누전 차단기인 모든 시료는 증폭회로의 전원부에 설치된 서지보호장치에 의해 입사되는 차동모드의 뇌임펄스전압에 차단되는 성능을 가지고 있었다. 4종의 시료는 KS C 4613에 정의된 뇌임펄스 부동작시험조건을 만족시키지 못하였으며, 그때의 오동작을 유발한 전압은 약 5∼6.5[kV]로 비교적 높았다. 서지보호장치가 설치된 경우를 모의한 시험조건에서는 3종의 누전차단기가 오동작하였으며, 누전차단기가 오동작을 일으키는 전압도 약 3∼5[kV] 정도로 비교적 낮았다.

  • PDF

Clinical Outcome of Endoscopic Procedure in Patients with Shunt Malfunction

  • Kyung Hyun Kim;Youngbo Shim;Ji Yeoun Lee;Ji Hoon Phi;Eun Jung Koh;Seung-Ki Kim
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권2호
    • /
    • pp.162-171
    • /
    • 2023
  • Objective : The goal of this study was to analyze the clinical outcomes of endoscopic third ventriculostomy (ETV) and endoscopic septostomy when shunt malfunction occurs in a patient who has previously undergone placement of a ventriculoperitoneal shunt. Methods : From 2001 to 2020 at Seoul National University Children's Hospital, patients who underwent ETV or endoscopic septostomy for shunt malfunction were retrospectively analyzed. Initial diagnosis (etiology of hydrocephalus), age at first shunt insertion, age at endoscopic procedure, magnetic resonance or computed tomography image, subsequent shunting data, and follow-up period were included. Results : Thirty-six patients were included in this retrospective study. Twenty-nine patients, 18 males and 11 females, with shunt malfunction underwent ETV. At the time of shunting, the age ranged from 1 day to 15.4 years (mean, 2.4 years). The mean age at the time of ETV was 13.1 years (range, 0.7 to 29.6 years). Nineteen patients remained shunt revision free. The 5-year shunt revision-free survival rate was 69% (95% confidence interval [CI], 0.54-0.88). Seven patients, three males and four females, with shunt malfunction underwent endoscopic septostomy. At the time of shunting, the age ranged from 0.2 to 12 years (mean, 3.9 years). The mean age at the time of endoscopic septostomy was 11.9 years (range, 0.5 to 29.5 years). Four patients remained free of shunt revision or addition. The 5-year shunt revision-free survival rate was 57% (95% CI, 0.3-1.0). There were no complications associated with the endoscopic procedures. Conclusion : The results of our study demonstrate that ETV or endoscopic septostomy can be effective and safe in patients with shunt malfunction.

태양광전원이 연계된 배전계통 보호협조기기의 부동작패턴 탐색알고리즘에 관한 연구 (A Study on Searching Algorithm for Malfunction Pattern of Protection Devices in Distribution System with PV Systems)

  • 권순환;태동현;이후동;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.652-661
    • /
    • 2020
  • 최근, 기후변화와 미세먼지 등에 의한 지구규모적인 환경문제를 해결하기 위하여, 정부에서는 RE 3020 정책을 시행하고 있으며, 이에 따라 대용량의 태양광전원이 배전계통에 연계되고 있다. 하지만, 대용량 태양광전원이 배전계통에 연계되는 경우, 태양광전원의 연계위치와 용량, 연계방식 및 고장지점에 따라 사고전류의 크기와 방향이 변하게 되고, 지락사고가 발생하여도 분류효과에 의하여 보호협조기기가 동작하지 않는 부동작 현상이 발생할 가능성이 있다. 따라서, 본 논문에서는 다수의 태양광전원이 배전계통에 연계되어 운용되는 경우, 리클로저(recloser, 이하 R/C)의 설치개소에 따라 보호협조기기가 동작하지 않는 부동작 메커니즘을 제시하고, 이를 바탕으로 다양한 시나리오에 기반한 보호협조기기의 부동작 패턴탐색 알고리즘을 제안한다. 또한, 보호협조 전용 해석 프로그램인 Off-DAS를 이용하여, 다수의 태양광 전원이 연계된 배전계통 모델링을 수행하고, 이를 바탕으로 다양한 시나리오에 따른 보호협조기기 부동작 패턴을 분석한다. 제안한 보호협조기기의 부동작패턴 탐색알고리즘 및 모델링을 바탕으로 시뮬레이션을 수행한 결과, R/C의 설치개소 및 태양광전원의 연계 패턴에 따라 부동작 현상이 발생함을 알 수 있어, 본 논문의 유용성을 확인하였다.

Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions

  • Lee, Jong-Beom;Ahn, Ho-Young;Lee, Hong-Jae;Yang, Ji-Ho;Yi, Jin-Seok;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권1호
    • /
    • pp.1-7
    • /
    • 2017
  • Objective : The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. Methods : We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. Results : The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were $2.21{\pm}24.57mmH_2O$. The frequency of CSF lumbar tapping was $2.06{\pm}1.26times$. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was $-3.69{\pm}19.20mmH_2O$. The mean frequency of CSF lumbar tapping was $2.07{\pm}1.25times$. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was $38.07{\pm}23.58mmH_2O$. The mean frequency of CSF lumbar tapping was $1.44{\pm}1.01times$. Pressure difference greater than $35mmH_2O$ was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant (p=0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Conclusion : Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is $35mmH_2O$ higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made.

USN을 이용한 목조문화재 방재시스템에 관한 연구 -불꽃감지기 오작동 확인시스템을 중심으로- (Study on the Disaster Prevention System for Wooden Cultural Assets Using USN -Focusing on the System Checking the Malfunction of Flame Detector-)

  • 백민호;김정호
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.49-54
    • /
    • 2010
  • 목조문화재의 화재특성을 보면 화재전파가 빠르고 화재가 발생하면 전소로 이어질 가능성이 큰 특징을 가지고 있다. 그러므로 화재의 예방과 초기 진압을 위해서는 상황을 정확히 인지할 수 있는 기술적인 대응과 더불어 인지된 문제를 조기에 대처할 수 있는 시스템이 필요하다. 이러한 기술을 첨단 유비쿼터스 기술에 의한 상황 감지, 그리고 상황에 따른 빠른 대처 즉, 진압에 활용하기 위해 본 연구에서는 유비쿼터스 센서 네트워크(USN) 기술, 불꽃감지기, 이미지 센서, USN 기반 문화재 방재 응용사례, 오작동 확인시스템 구현 등에 대해서 살펴보고 유비쿼터스형 문화재 방재시스템에 대해 불꽃감지기 오작동 확인시스템에 대해 실험하여 연구결과를 제시하였다.