• 제목/요약/키워드: MalDC

검색결과 10건 처리시간 0.067초

MalDC: Malicious Software Detection and Classification using Machine Learning

  • Moon, Jaewoong;Kim, Subin;Park, Jangyong;Lee, Jieun;Kim, Kyungshin;Song, Jaeseung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권5호
    • /
    • pp.1466-1488
    • /
    • 2022
  • Recently, the importance and necessity of artificial intelligence (AI), especially machine learning, has been emphasized. In fact, studies are actively underway to solve complex and challenging problems through the use of AI systems, such as intelligent CCTVs, intelligent AI security systems, and AI surgical robots. Information security that involves analysis and response to security vulnerabilities of software is no exception to this and is recognized as one of the fields wherein significant results are expected when AI is applied. This is because the frequency of malware incidents is gradually increasing, and the available security technologies are limited with regard to the use of software security experts or source code analysis tools. We conducted a study on MalDC, a technique that converts malware into images using machine learning, MalDC showed good performance and was able to analyze and classify different types of malware. MalDC applies a preprocessing step to minimize the noise generated in the image conversion process and employs an image augmentation technique to reinforce the insufficient dataset, thus improving the accuracy of the malware classification. To verify the feasibility of our method, we tested the malware classification technique used by MalDC on a dataset provided by Microsoft and malware data collected by the Korea Internet & Security Agency (KISA). Consequently, an accuracy of 97% was achieved.

DC제거용 FIR필터가 거리계전기에 미치는 영향 분석 (The Influence of a FIR Filter on Distance Relaying Algorithm)

  • 오예준;장준;박진규;김수환;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2195_2196
    • /
    • 2009
  • DC-offset is a very important subject in power systems protection, since DC-offset causes mal-operation of the distance relay. This paper deals with the influence of a FIR filter used for removing the DC-offset upon the convergence characteristics of distance relaying algorithm based on Fourier Transform.

  • PDF

전기자동차용 DC-DC 컨버터 최적설계 (Optimization Design and Implementation of DC-DC Converter(LDC) for Electric Vehicle)

  • 권용효;김승모;김표수;김말수;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.107-108
    • /
    • 2012
  • This paper presents design and implementation of the LDC(1.8 kW DC-DC Converter for Electric Vehicles). For Implementation of the LDC, the adapted topology is ZVS(Zero Voltage Switching) PSFB(Phase Shift Full Bridge) with Digital Control is adopted. Also, for the purpose of stable operation of the LDC in vehicle with variable electrical load condition, Continuous Voltage and Current Limit Control scheme based on PI controller are developed. According to real-car test mode, the prototype of proposed the LDC is verified with performance and stability. Thus, optimizing design and implement of the LDC are discussed, and experimental results are presented.

  • PDF

전기자동차 모터구동용 전력변환장치(PCU) 설계 및 구현 (Design and Implementation of Power Conversion Unit(PCU) for Motor of Electric Vehicle)

  • 김말수;김승모;허남억;오승진;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.201-202
    • /
    • 2012
  • This paper presents design and implementation of the PCU(150 kVA 3-Phase PWM Inverter for Electric Vehicles). For Implementation of the PCU, it is consist with Case, Connectors, IGBT module for PWM switching, DC-capacitor for dc-source, resolver for sensing of speed & position, and PCB board for control & gate-driver. Also, for the purpose of stable operation of the PCU in vehicle with variable torque condition in motor, current control scheme based on torque-map are developed. According to real-car test mode, the prototype of proposed the PCU is verified with performance and stability. Thus, design and implement of the PCU are discussed, and experimental results are presented in this paper.

  • PDF

전철용 공랭식 정류기 성능 향상방안에 관한 연구 (Research on improvement performance of air-cooled rectifier for Electric railway)

  • 한학수;최병운;배상만;김찬식;김영은
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1489-1497
    • /
    • 2009
  • The rectifier for Electric railway is one of the most important facilities in DC urban railway which converts power from KEPCO(AC 22.9kV) to the electric mil car(DC 1.5kV), therefore it should be managed as the best condition for the drive. There are several things to cause performance degradation and deterioration of parts such as pollutants occurred by it established under the ground such as dust or foreign substances, rapid changes of driving current, and pyrogen which put the rectifier for Electric railway in malfunction. On the flow of time, the rectifier for Electric railway is causing a malfunction or failure which drive electric rail car in operations as well as loss of life. In this research we try to find the way of removing the various components of mal-functions in the performance of the rectifier for Electric railway by Over-Haul and reform itself, which gives us to get the chance investment of the reduction, the reliability of power supply to the electric rail car.

  • PDF

CT와 CCVT의 오차를 고려한 거리 계전기의 응동 분석 (Analysis of the response of a distance relay considering the errors of CT and CCVT)

  • 강용철;정태영;최재선;강해권;김광무;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.12-15
    • /
    • 2008
  • A distance relay has been widely used for transmission line protection. The distance relay detects a fault based on the calculated impedance i.e. the ratio of the voltage to the current measured from a current transformer (CT) and a coupling capacitor voltage transformer (CCVT), respectively. When a fault occurs and a CT saturates due to the magnitude of fault current, dc component, primary time constant, and the remanent flux of the iron core, the secondary current of a CT is distorted On the other hand, non-fundamental components generated during a fault can increase the error of a CCVT, particularly when a fault distance is short. The distortion of the current and voltage can cause mal-operation or the operating time delay of a distance relay. This paper describes the response of a distance relay considering the errors of a CT and a CCVT. The results indicate that the severe distortion of a CT and a CCVT have noticeable effect to a distance relay.

  • PDF

EMTP-RV를 이용한 CT포화 모델링 (EMTP-RV Modeling of CT Saturation)

  • 강용철;최재선;정태영;강해권;장성일;김용균;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.9-11
    • /
    • 2008
  • A protection current transformer (CT) has been widely used for protection devices. When a fault occurs, a CT should provide the faithful reproduction of the primary fault current. However, a CT may saturates due to the magnitude of fault current, dc component primary time constant and the remanent flux of the iron core, and the secondary current of a CT is distorted. The distorted current can cause mal-operation or the operating time delay of a protection relay. This paper provides a modeling of CT saturation using EMTP-RV. The performance of the proposed CT saturation modeling was investigated under various fault conditions varying the fault distance, fault inception angle, and remanent flux of the iron core. The results indicate that the proposed EMTP-RV modeling can operate correctly, and the reasons for CT saturation are verified by EMTP-RV simulations.

  • PDF

만성 뇌졸중 환자를 대상으로 한 일차 체성 감각 피질을 자극한 경두개 직류 전류 자극이 라이프 케어 증진을 위한 체성감각과 상지기능에 미치는 영향 (The Effect of Transcranial Direct Current Stimulation over the Primary Somatosensory Cortex in Patients with Chronic Stroke on Somatosensory and Upper Limb Function for Improving Life Care)

  • 김선호
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제14권6호
    • /
    • pp.269-277
    • /
    • 2020
  • 본 연구의 목적은 감각 결손이 있는 만성 뇌졸중 환자를 대상으로 경 두개 직류 전류 자극을 체성감각피질에 적용했을 때, 감각의 회복과 상지 기능의 회복을 알아보고자 하는 것이다. 만성 뇌졸중 환자 20명을 실험군 10명, 대조군 10명으로 나누어 실시하였다. 실험군은 환측 체성감각피질에 경 두개 직류 전류 자극을 적용하였으며, 대조군은 위상 자극을 실시하였다. 중재는 총 2주간, 10회, 회기 당 20분씩 진행되었다. 체성감각 평가는 The Erasmus MC modifications to the (revised) Nottingham Sensory Assessment(EmNSA), Semmes-Weinstein monofilament examination(SWME), 상지기능 평가는 퍼글마이어평가(FMA), 운동 활동 척도(MAL), 가속도계를 사용하였다. 연구 결과, 실험군은 대조군보다 전체적인 촉각 감각과 고유수용성 감각, 피질 감각, 지각의 민감도에서 유의한 개선을 보였으며, 환측 상지의 사용량에서 통계학적 유의한 차이를 나타냈다. 본 연구 결과를 기반으로 체성감각 회복과 상지기능의 회복을 위한 tDCS의 효과적인 임상 적용의 가능성을 높일 수 있을 것으로 생각된다.

Modulation of the aqueous extract of Bupleuri radix on glycine-induced current in the acutely dissociated rat periaqueductal gray neurons

  • Sung, Yun-Hee;Shin, Mal-Soon;Kim, Tae-Soo;Lee, Sang-Won;Kim, Youn-Jung;Shin, Hye-Sook;Kim, Hong;Kim, Chang-Ju
    • Advances in Traditional Medicine
    • /
    • 제7권5호
    • /
    • pp.549-555
    • /
    • 2008
  • Bupleuri radix (Umbelliferae), the dried root of Bupleurum Chinense DC, has been clinically used to mitigate pain sensation. The descending pain control system consists of three major components, and modulation of pain in the periaqueductal gray is the most extensively studied descending pain control system. However, the relation of Bupleuri radix on the descending pain control system has not been clarified. In the present study, modulation of the aqueous extract of Bupleuri radix on glycine-induced ion current in the acutely dissociated periaqueductal gray neurons was investigated by using nystatin-perforated patch-clamp technique under voltage-clamp condition. In the present results, the glycine-induced ion current was significantly suppressed by 0.1 mg/ml Bupleuri radix, while treatment with $10^{-5}\;M$ naltrexone, opioid receptor antagonist, alleviated Bupleuri radix-induced inhibition on glycine-induced ion current. The present study showed that the aqueous extract of Bupleuri radix may activate descending pain control system through inhibition on glycine-induced ion current in the periaqueductal gray neurons and this effect is mediated by opioid receptors.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제12권7호
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF