• Title/Summary/Keyword: Maintenance Water

Search Result 1,616, Processing Time 0.037 seconds

Water Level Tracking System based on Morphology and Template Matching

  • Ansari, Israfil;Jeong, Yunju;Lee, Yeunghak;Shim, Jaechang
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.12
    • /
    • pp.1431-1438
    • /
    • 2018
  • In this paper, we proposed a river water level detection and tracking of the river or dams based on image processing system. In past, most of the water level detection system used various water sensors. Those water sensors works perfectly but have many drawbacks such as high cost and harsh weather. Water level monitoring system helps in forecasting early river disasters and maintenance of the water body area. However, the early river disaster warning system introduces many conflicting requirements. Surveillance camera based water level detection system depends on either the area of interest from the water body or on optical flow algorithm. This proposed system is focused on water scaling area of a river or dam to detect water level. After the detection of scale area from water body, the proposed algorithm will immediately focus on the digits available on that area. Using the numbers on the scale, water level of the river is predicted. This proposed system is successfully tested on different water bodies to detect the water level area and predicted the water level.

Estimation of Compressive Strength of Concrete with Granitic Aggregates : Rebound hammer and Ultrasonic Methods (화강암 골재를 사용한 콘크리트의 비파괴 시험에 의한 강도평가)

  • 김현우;이종태;윤기원;김병극;김무한;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.651-654
    • /
    • 1999
  • It is required that the compressive strength of concrete should be estimated accurately from the view point of efficient quality control and maintenance of buildings. In this paper, the equations to estimate the compressive strength of concrete using granite aggregates were suggested for both rebound hammer method and ultrasonic pulse velocity method. The results were compared with those for different age or curing condition. The rebound numbers for concrete cured in air were larger than for concrete cured in water. The difference between rebound numbers for concrete cured in water and in air was larger than for concrete cured in water. The difference between rebound numbers for concrete cured in water and in air was larger when water cement ratio was high. Also, with the increase of age, the velocity of ultrasonic pulse for concrete cured in air was measured larger when compared with that in water.

  • PDF

Preliminary Experiment of Gravel Contact Oxidation Process in the Tropics

  • Abdullah Keizrul bin;Omachi Toshikatsu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.12-17
    • /
    • 2006
  • Natural rivers have water purification functions called Gravel Contact Oxidation Process, which decontaminate river water by biological absorption, oxidation and degradation on riverbed gravels. This function has been developed and applied to many small/medium-sized urban rivers in Japan as one of the direct river water purification methods. However the method hasn't been verified in the tropics, which have different climate conditions and river characteristics. A preliminary experiment carried out at a polluted urban tributary in the outskirts of Kuala Lumpur, Malaysia where an increasing attention has been paid to river environment, showed a good applicability to the tropical conditions as a technically practical water purification measure with some maintenance cares for sludge management.

  • PDF

A Study on the cause and permanent measures on trouble of the GCB for the Main Tr. of Voltage, 154kV (154kV 주변압기용 가스차단기(GCB) 소손에 따른 원인규명과 항구대책 분석)

  • Jeon, Kyu-Nam;Chang, Moon-Soung;Ock, Gwang-Seok;NamGoong, Hyuk;Ahn, Joo-Hoon;Jeong, Jae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.285-286
    • /
    • 2008
  • The Gas Circuit Breaker for the Main Transformer of voltage, 154kV at the ist Hapcheon hydraulic power station, break down by the falling of a thunderbolt from now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem.

  • PDF

Frictional Characteristics of Stainless Steel Ball Bearings Lubricated with Hot Water

  • Lee, Jae-Seon;Kim, Jong-In;Kim, Ji-Ho;Park, Hong-Yune;Zee, Sung-Qunn
    • KSTLE International Journal
    • /
    • v.4 no.2
    • /
    • pp.43-46
    • /
    • 2003
  • Water-lubricated frictional characteristics of a stainless steel ball bearings are not well known compared to the oil-lubricated frictional characteristics. Furthermore a study on friction at a high temperature is rare because the bearing maintenance strategy for water-lubricated or chemicals-lubricated bearings of equipment is generally based on the replacement of the failed bearings-and parts. Ball bearings and ball screw are installed in the power transmission for the newly developing integral reactor and these are lubricated with chemically-controlled pure water at a high temperature and a high pressure. Bearings and power transmitting mechanical elements for an atomic reactor requires high reliability and high performance during the estimated lifetime, and it should be verified. In this paper, experimental research results of the frictional characteristics for water-lubricated ball bearings are presented as a preliminary investigation.

A Study on the economic analysis of the standing water level control system (SAL상수위 제어시스템의 경제성 분석에 관한 연구)

  • Hong, Jong-In;Hong, Seong-Wook;Kim, Sang-Won;Yang, Jin-Kook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.281-283
    • /
    • 2013
  • In this paper, standing water level control system and a comparison of existing methods (anchor, PDD, DM) and economic analysis was conducted. 1) Cost PDD method (6%), DM system (4%), and the SAL standing water level control system (4%), except for the anchor system is similar to the construction of three methods based on the portion of the anchor system was analyzed that. 2) construction and maintenance costs compared with the sum of the partial was, anchor system (100%), PDD method (39%), DM system (37%), the SAL standing water level control system (21%), the SAL standing water level control system was identified as the lowest cost method of.

  • PDF

Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention (재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구)

  • Yang, Young Jin;Lee, Tae Ho;Oh, Sue Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

Development on the Computerizing Assessment System Model for the Diagnosis Data of High-Voltage Motors (고압 유도 전동기 절연진단 데이터 관리 전산화 모델 개발)

  • Chae, Ji-Seog;Lee, Eun-Chun;Lee, Jong-Seok;Ham, Dong-Young;Heo, Seon-Gu;Yun, Suk-Jun;Choi, Jang-Young
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1200-1201
    • /
    • 2015
  • 고전압 전력설비 진단은 기기의 열화 상태를 측정하여 이상 사고를 미리 예측하여 방지하는 것을 목적으로 실시한다. 고전압 전력설비의 유지관리 방안은 일정 시간 경과후 보수하는 개념(TBM: Time Based Maintenance) 이후 설비의 상태를 진단하여 유지보수 방안을 결정하는 개념(CBM: Condition Based Maintenance)으로 진보해 감에 따라 전력설비의 상태진단 기술의 중요성은 증대될 전망이다. 고전압 전력설비의 절연진단은 직류시험(절연저항, PI)과 교류시험($tan{\delta}$, PD)이 실시되며 과거 진단 데이터의 추세분석을 통한 정확한 상태진단이 요구되고 있다. 고압 유도 전동기 절연진단 데이터 관리 전산화 모델은 고전압 전력기기(발전기, 변압기, 전동기, 케이블 등)의 절연진단 및 유지보수 이력에 관한 자료들을 저장, 조회 및 검색을 하기 위한 데이터베이스를 구축하고 구축된 데이터를 활용하여 과거 이력조회, 추이분석, 진단 데이터의 분석기법을 통한 전력기기의 상태평가로 합리적인 개 대체 의사결정을 지원한다. 또한, 유입식 변압기의 절연유 가스분석 알고리즘을 전산화 하여 10종 가연성 가스에 따른 Gas Pattern 평가로 고장 원인, 현상 및 조치 등에 대한 출력이 가능한 프로그램의 개발로 고전압 전력설비 진단기술과 IT기술의 융 복합 기술로서 고전압 전력설비의 유지관리 기술을 한 차원 더 진보시킬 것으로 판단된다.

  • PDF

A Study on Experiment for Improvement of Water Quality in Concrete Block Using Illite and TiO2 Powder (일라이트와 이산화티탄을 활용한 콘크리트 블록의 수질환경개선을 위한 실험연구)

  • Her, Jae-Won;Kang, Kyung-Soo;Kim, Young-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • In order to conduct the "A Study on Experiment for Improvement of Water Quality in Concrete Block Using illite and $TiO_2$ Powder", as a result of the preliminary mortar experiment, water quality purification characteristic test, pollution-resistance test, fish poison test, and the related KS-equivalent tests after manufacturing the actual concrete block, the following conclusion were deduced. As a result of the concrete block functional evaluation equivalent to KS, all the conditions showed higher compressive strength. Even though increase of absorption rate, according to illite replacement in vesicular structure, was expected as a problem, it was replaced after mixing with Titanium dioxide, and then Titanium dioxide was settled in large pores of illite so there was no problem in absorption rate.

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment (고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.