• Title/Summary/Keyword: Main flow

Search Result 3,314, Processing Time 0.026 seconds

Optical Flow Orientation Histogram for Hand Gesture Recognition (손 동작 인식을 위한 Optical Flow Orientation Histogram)

  • Aurrahman, Dhi;Setiawan, Nurul Arif;Oh, Chi-Min;Lee, Chil-Woo
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.517-521
    • /
    • 2008
  • Hand motion classification problem is considered as basis for sign or gesture recognition. We promote optical flow as main feature extracted from images sequences to simultaneously segment the motion's area by its magnitude and characterize the motion' s directions by its orientation. We manage the flow orientation histogram as motion descriptor. A motion is encoded by concatenating the flow orientation histogram from several frames. We utilize simple histogram matching to classify the motion sequences. Attempted experiments show the feasibility of our method for hand motion localization and classification.

  • PDF

Oil Flow Distribution Control of Engine Lubrication System Using Orifice Component (오리피스를 이용한 엔진 윤활시스템 유량분배 제어)

  • Yun Jeong-Eui
    • Tribology and Lubricants
    • /
    • v.22 no.1
    • /
    • pp.47-52
    • /
    • 2006
  • It is very important to control pressure and flow rate distribution on each component of engine lubrication network. Sometimes many kinds of orifice are used to control flow rate in the hydraulic lubrication field. In this study orifices were adopted on the lubrication network to control oil flow rate distribution. And unsteady transient flow network analysis was carried out to find out the effects of orifices on the engine oil circuit system.

TURBULENT FLOW AROUND AN INCLINED SQUARE CYLINDER (기울어진 정방형 실린더를 지나는 난류 유동)

  • Yoon, Dong-Hyeog;Yang, Kyung-Soo
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.52-58
    • /
    • 2009
  • Turbulent flow past an inclined square cylinder immersed in a cross stream is numerically investigated. The angle of incidence of main flow is one of the key factors determining at which edges the flow separates. In the present study, based on comprehensive numerical simulations, effects of inclination angle on the flow characteristics are elucidated and the related physical explanation is presented.

A Study on the Static mixer and Microbubble of the Sidestream Ozone Contact System to Improve Water Treatment Efficiency (사이드스트림 오존 접촉조에서 수처리 효율 향상을 위한 정적혼합기와 미세기포에 관한 연구)

  • Kim, Jin-Hoon;Park, Jong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.763-768
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.

Heat transfer on two nearby circular cylinders (두 개의 원형 실린더 주위의 열전달)

  • Han, Tae-Heon;Yang, Kyung-Soo;Yoon, Dong-Hyeog;Lee, Kyong-Jun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2890-2895
    • /
    • 2007
  • Heat transfer on two identical nearby circular cylinders immersed in the uniform cross flow at Re = 100 and Pr = 7.0 was numerically studied. We consider all possible arrangements of the two circular cylinders in terms of the distance between the two cylinders and the inclination angle with respect to the direction of the main flow. It turns out that significant changes in the characteristics of heat transfer are noticed depending on how the two circular cylinders are positioned, resulting in quantitative changes of heat transfer coefficients on both cylinders. Collecting all the numerical results obtained, we propose a contour diagram for averaged Nusselt number for each of the two cylinders. The perfect geometrical symmetry implied in the flow configuration allows one to use those diagrams to estimate heat transfer rates on two identical circular cylinders arbitrarily positioned in physical space with respect to the main flow direction.

  • PDF

HEAT TRANSFER ON TWO NEARBY CIRCULAR CYLINDERS (두 개의 원형 실린더 주위의 열전달)

  • Han, T.H.;Yang, K.S.;Yoon, D.H.;Lee, K.
    • Journal of computational fluids engineering
    • /
    • v.13 no.2
    • /
    • pp.42-47
    • /
    • 2008
  • Heat transfer on two identical nearby circular cylinders immersed in the uniform cross flow at Re=120 and Pr=0.7 was numerically studied. We consider all possible types of arrangements of the two circular cylinders in terms of the distance between the two cylinders and the inclination angle with respect to the direction of the main flow. It turns out that significant changes in the characteristics of heat transfer are noticed depending on how the two circular cylinders are positioned, resulting in quantitative changes of heat transfer coefficients on both cylinders. Collecting all the numerical results obtained, we propose a contour diagram for averaged Nusselt number for each of the two cylinders. The perfect geometrical symmetry implied in the flow configuration allows one to use those diagrams to estimate heat transfer rates on two identical circular cylinders arbitrarily positioned in physical space with respect to the main flow direction.

An Outlook on Rotordynamic Pump Theory Development

  • Ni, Yongyan;Pan, Zhongyong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.99-118
    • /
    • 2017
  • ECHO progress was defined to depict the rotordynamic pump theory development. Experience (E) era for pumps lasted nearly one and a half hundred years before the Industrial Revolution due to the low rotation speed of motor and undeveloped manufacture ability. Classic (C) theory referring to quasi-static performance as well as the items those were not able to be steadily resolved under the level were briefly and sophisticated outlined. Since 1962, flow instabilities and the dynamic responses had come into main attention with the development of the modern technologies such as ballistic missile, rocket and space shuttle main engine, and were finally heuristically (H) elucidated by talented scholars and researchers. Recently, new applications for the pumps open (O) to the surrounding fluid and diversity of the medium such as multiphase flow need more studies and some examples were briefly introduced to display the potential problems lastly.

A Study on the Microbubble Characteristics of Ozone to Improve Dissolution Efficiency (오존 용해효율 향상을 위한 미세기포 특성 연구)

  • Kim, Jin-Hoon;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.6
    • /
    • pp.47-53
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.

Verification Model of the Feedwater Flow for the Calculation of Corrective Performance of Turbine Cycle (터빈 사이클의 보정 성능 계산을 위한 급수 유량의 검증 모델)

  • Kim, Seong-Kun;Yang, Hac-Jin;Lee, Kang-Hee;Choi, Kwang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.538-544
    • /
    • 2012
  • Analysis of thermal performance is required for the economic operation of turbine cycle of power plant. We developed corrective model of main feed water flow which is the most important parameter for the precise analysis of turbine cycle performance. Classification model for the identification of feed water flow measurement status was applied to increase the suitability of the corrective model. We used neural network and support vector machine to develop estimation model of main feed water flow with more generalization capability. The estimation model can be used practically to evaluate corrective performance of turbine cycle plant.

Analysis of Control Valve Characteristics in a Steam Turbine (증기터빈에서의 제어밸브에 관한 특성 고찰)

  • Yook, Sim-Kyun;Sur, Jung-Surk;Cho, Chang-Ho;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.639-642
    • /
    • 1999
  • In this paper, we are going to explain the operation principles of steam control valve, governing equation of compressible and incompressible fluids and flow characteristic according to plug(disc) types. Governor and the relation of main steam pressure to flow and main steam will also be explained.

  • PDF