• 제목/요약/키워드: Main Spindle Design

검색결과 56건 처리시간 0.019초

Statistical Qualitative Analysis on Chemical Mechanical Polishing Process and Equipment Characterization

  • Hong, Sang-Jeen;Hwang, Jong-Ha;Seo, Dong-Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권3호
    • /
    • pp.115-118
    • /
    • 2011
  • Process characterization of the chemical mechanical polishing (CMP) process for undensified phosphosilicate glass (PSG) film is reported using design of experiments (DOE). DOE has been addressed to experimenters to understand the relationship between input variables and responses of interest in a simple and efficient way. It is typically beneficial for determining the adequate size of experiments with multiple process variables and making statistical inferences for the responses of interests. Equipment controllable parameters to operate the machine include the down force (DF) of the wafer carrier, pressure on the backside of the wafer, table and spindle speed (SS), slurry flow rate, and pad condition. None of them is independent; thus, the interaction between parameters also needs to be indicated to improve process characterization in CMP. In this paper, we have selected the five controllable equipment parameters, such as DF, back pressure (BP), table speed (TS), SS, and slurry flow (SF), most process engineers recommend to characterize the CMP process with respect to material removal rate (RR) and film uniformity as a percentage. The polished material is undensified PSG. PSG is widely used for the plananization in multi-layered metal interconnects. We identify the main effect of DF, BP, and TS on both RR and film uniformity, as expected, by the statistical modeling and analysis on the metrology data acquired from a series of $2^{5-1}$ fractional factorial design with two center points. This revealed the film uniformity of the polished PSG film contains two and three-way interactions. Therefore, one can easily infer that the process control based on better understanding of the process is the key to success in semiconductor manufacturing, typically when the wafer size reaches 300 mm and is continuously scheduled to expand up to 450 mm in or little after 2012.

파워바이스 증력장치 최적설계에 관한 연구 (A Study on the Optimum Design of Power Vice-Strengthening Device)

  • 이경일;정윤수;김재열
    • 한국기계가공학회지
    • /
    • 제16권6호
    • /
    • pp.69-74
    • /
    • 2017
  • In the current machining industry, machining precision is necessary and machining is being carried out. In this ultra-precision machining industry, the fixation of the workpiece is very important and the degree of machining depends on the degree of fixation of the workpiece. In ultra-precision machining, various methods, such as using a vise chuck or the like and using bolt nut coupling, are used for fixing a workpiece to an existing machine tool. In particular, when the precision gripping force of the jig is insufficient during machining of the ultra-precision mold parts, the machining material shakes due to the vibration or friction, and the machining precision is lowered. In the ultra-precision machining of power transmission parts, such as gears, the accuracy of the product is then determined. In addition, the amount of heat generated during machining has a significant effect on the machining accuracy. This is because the vibration value changes according to the grasp force of the jig that fixes the workpiece, and the change in the calorific value due to the change in the main shaft rotation speed of the ultra-precision machining. The increase in the spindle rotation speed during machining decreased the heat generation during machining, and the machining accuracy was also good, and it was confirmed that the machining heat changed according to the fixed state of the workpiece and the machining accuracy also changed. In this study, we try to optimize the driving part of the power vise by using structural analysis, rather than the power vise, using the basic mechanical-type power unit.

TEM 정밀 시편 제작용 몰리브덴 합금 미세 고정 부품의 제작을 위한 절삭 가공 방법에 관한 연구 (A study on machining method about molybdenum alloy micro fixing part for TEM precision specimen.)

  • 김기범;이창우;이해진;함민지;김건희
    • Design & Manufacturing
    • /
    • 제11권3호
    • /
    • pp.19-24
    • /
    • 2017
  • In these days, increase requirement of TEM (Transmission Electro Microscope) in not only scientific field but also industrial field. Because TEM can measure inner-structure of specimen a variety of materials like metal, bio. etc. When use TEM, specimen should be thin about 50nm. So making for thin specimen, use Ion milling device that include specimen holder. The holder generally made of Aluminium Aluminium holder is worn away easily. For this reason, using time of ion milling with aluminum holder is too short. To solve the problem, we replace aluminium holer to molybdenum alloy holder. In this paper, we design molybdenum alloy holer for CAM and modify CAD modeling for effective machining process. So we array a specimen 3 by 4 and setup orientation for one-shot machining process. Next we make a CAM program for machining. we making a decision two machining strategy that chose condition of tool-path method, step-down, step-over. etc. And then conduct machining using CNC milling machining center. To make clear difference between case.1 and case.2, we fixed machining conditions like feed-rate, main spindle rpm, etc. After machining, we confirm the condition of workpiece and analysis the problems case by case. Finally, case.2 work piece that superior than case.1 cutting with WEDM because that method can not ant mechanical effect on workpiece.

인간 미성숙난자의 동결.융해후 체외 배양된 난자에 대한 염색체 분석 (Chromosome Configurations of Human Oocytes Matured in vitro following Cryopreservation at the Germinal Vesicle Stage)

  • 박성은;정창조;손원영;정형민;이숙환;이우식;고정재;윤태기;차광열
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제24권2호
    • /
    • pp.253-259
    • /
    • 1997
  • Objective: To investigate effects of cryoprotectant and cryopreservation on the chromosome of the human immature oocytes. Design: Intact cumulus-enclosed immature oocytes were collected from unstimulated ovaries and divided into three groups, such as no treatment as control (group 1), only 1,2-propanediol (PROH)-treated (group 2), and cryopreserved oocytes (group 3). Oocytes in group 1, 2, and survived oocytes after cryopreservation in group 3 were cultured for 48 hours. Setting: Infertility Medical Center at the CHA General Hospital, Seoul, Korea. Patients: Oocytes were obtained from Patients undergoing gynecological surgery. Main Outcome Measures: Maturation rate, abnormality in chromosomes by fluorescence in situ hybridization (FISH). Results: There was no effect of PROH only treatment on the chromosomal abnormalities in group 2 compared to control oocytes (41.4% and 31.8%, respectively). Whereas significantly increased abnormalities in chromosome (77.8%) were found in group 3. Conclusions: Human oocytes matured in vitro after cryopreservation at the germinal vesicle (GV) stage showed increased incidence of chromosomal abnormalities. These abnormalities may impair the capacity for further development of the embryos derived from frozen-thawed oocytes.

  • PDF

가스밸브의 변형거동 안전성에 관한 유한요소해석 (Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve)

  • 김청균
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.70-75
    • /
    • 2017
  • 본 연구에서는 차단기능형 수평식 가스밸브와 기존 수직식 가스밸브의 변형거동 안전성을 FEM으로 해석하였다. FEM 해석결과에 의하면, 차단기능형 수평식 가스밸브의 나사부와 가스방출구에 가스내압이 작용할 때 밸브몸체의 우측 끝단부에서 최대 변형량 $4.4{\mu}m$가 발생하였다. 두 번째로 큰 변형량 $2.9{\mu}m$는 안전밸브가 설치된 포트의 끝단부에 형성된 것으로 나타났다. 이렇게 작은 변형량이 발생한 것은 나사부, 가스방출구, 스템 및 스핀들 축이 장착되는 포트, 안전밸브 포트로 구성되는 수평식 가스밸브의 평형이 잘 이루어지도록 설계되었기 때문이다. 반면에 나사부와 가스방출구에 가스내압이 작용할 때, 기존 차단기능형 수직식 가스밸브의 상단부에서 최대 변형량 0.076mm가 형성된 것으로 나타났다. 가스유출구의 좌측 끝단부에서 두 번째로 큰 최대 변형량 0.055mm가 발생하였다. 이러한 변형량은 차단기능형 안전장치의 그루브에 삽입된 오링의 밀봉간극에 영향을 미칠 가능성이 높다. 따라서 본 연구에서는 LPG 용기용 가스밸브의 가스누출을 완벽하게 차단할 수 있는 메커니즘을 갖춘 차단기능형 수평식 가스밸브가 수직식 가스밸브에 비해 우수하다할 수 있다.

CAD/CAM 시스템을 이용한 레저보트의 플러그 모델링 및 가공 (The Modelling and Machining of Leisure Boat Plug using CAD/CAM System)

  • 김성일
    • 대한공업교육학회지
    • /
    • 제33권2호
    • /
    • pp.259-272
    • /
    • 2008
  • 목형의 곡면을 수작업으로 제작할 때 많은 경험이 있다 하더라도 정확한 곡면 형상, 좌우대칭 등의 작업에는 상당한 어려움이 따른다. 기계를 사용한 단순한 2차원 목형은 NC 프로그램을 작성하여 간단히 가공할 수 있지만, 복잡한 곡면 형상의 가공은 3차원 CAM s/w, 공구, 재료 등 다양한 변수가 따르기에 축척된 많은 데이터를 필요로 한다. 3차원 곡면 가공 제품 중 제품의 설계 및 디자인 s/w가 다르다면, 데이터의 호환 및 가공 시스템을 구성하기에는 더더욱 어려움이 따른다. 최근 레저에 대한 관심이 증가함에 따라 레저보트 업체에서는 수작업 대신 레저장비에 대한 소비자의 디자인 및 설계제작 요구에 대응하기 위해서 가공 자동화 및 정밀도 향상을 위하여 CAD/CAM 시스템을 이용한 3차원 모델링 및 CNC 공작기계를 사용한 새로운 개념의 플러그 제작 자동화 기술 개발이 필요하게 되었다. 따라서 본 연구는 수작업으로 제작하던 레저보트의 목형을 정밀도와 생산성 향상을 위하여 디자인을 강조한 3차원 디자인 s/w로 디자인하고, 이 디자인 한 데이터를 이용하여 3차원 CAM s/w에서 모델링 한 후, 가공 데이터를 산출하여 정밀가공기계인 머시닝센터로 가공하고자 하는 것이다. 이 연구 결과를 바탕으로 전문계 고교에서도 CAD 및 단순 가공 기술교육에서 벗어나 다양한 디자인으로 된 곡면 가공 수요자의 요구에 대응하기 위한 3차원 모델링과 3차원 정밀 가공 시스템의 교육 및 개발에 도움이 되었으면 한다. 본 연구는 선박의 하단부인 헐(Hull)의 목형인 플러그(plug)를 가공하기 위하여 플러그의 재료, 2차원 도면 형상을 3차원 형상으로의 모델링, 3차원 디자인 모델링, 가공을 위한 CAM, CNC 공작기계를 이용한 가공 기술 등 여러 가지 융합되고 복합적인 기술인 CAD/CAM 시스템을 활용한 모델링 및 플러그 가공 기술을 개발하는 것이다. 학생들에게는 기술개발의 중요성을, 업체에게는 생산성 향상이 주목적이다.