• Title/Summary/Keyword: Magnetic-induced energy

Search Result 111, Processing Time 0.029 seconds

Field-Induced Translation of Single Ferromagnetic and Ferrimagnetic Grain as Observed in the Chamber-type μG System

  • Kuwada, Kento;Uyeda, Chiaki;Hisayoshi, Keiji;Nagai, Hideaki;Mamiya, Mikito
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.308-310
    • /
    • 2013
  • Translation induced by the field-gradient force is being observed for a single ferromagnetic iron grain and a ferrimagnetic grain of a ferrite sample ($CuFe_2O_4$). From measurements on the translation, precise saturated magnetization of $M_S$ is possible for a single grain. The method is based on the energy conservation rule assumed for the grain during its translation and the grain is translated through a diffuse area under microgravity conditions. The results of the two materials indicate that a field-induced translation of grain bearing spontaneous moment is generally determined by a field-induced potential $-mM_SH(x)$ where m denotes the mass of sample. According to the above translations, the detection of $M_S$ is not interfered by any signals from the sample holder. The $M_S$ measurement does not require m value. By observing translations resulting from fieldinduced volume forces, the magnetization of a single grain is measurable irrespective of its size; the principle is also applicable to measuring susceptibility of diamagnetic and paramagnetic materials.

A Study on Design and Characteristics of Linear Magnetostrictive Actuator Using Terfenol-D (Terfenol-D를 이용한 선형 자기변형 구동기의 설계 및 특성 연구)

  • 임채욱;정태영;문석준;김병현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.4
    • /
    • pp.308-316
    • /
    • 2003
  • Terfenol-D is one of magnetostrictive materials which have the property of converting the energy in magnetic fields into mechanical movement and vice versa. We designed and fabricated a linear magnetostrictive actuator using Terfenol-D. It has 25 mm diameter and 100 mm long. To grasp the characteristics of it, a series of tests were performed in the range of 50 Hz below. Induced-strain actuation displacements of the actuator measured by test and predicted by magnetic analysis agreed well. And blocked forces according to the input currents were estimated from the testing results. Modelling method representing the exerting force of a linear magnetostrictive actuator was confirmed through some testing results.

Experiment on Small A.C. MHD Power Generator (소용량 교류 MHD발전기에 대한 실험적 연구)

  • Choon Saing Jhoun
    • 전기의세계
    • /
    • v.25 no.5
    • /
    • pp.79-87
    • /
    • 1976
  • This paper is to investigate the A.C generation of MHD engine, converting directly the kinetic energy of conductive gas in high temperature to electric power by the effect of magnetic field. It is known that there are at least two kinds of method in A.C MHD power generation; one, by sending stationary plasma flow in an alternating or rotating magnetic field and the other, by transmission of pulse type plasma flow in uniform and constant magnetic field, former method is adopted here. In order to raise the total efficiency of close cycle in combination with nuclear power and MHD genertaion, an argon plasma jet is utilized as heat source, which is not mixed with the seed material, and the design data are obtained for A.C MHD generation in small capacity, but induced voltage and power output have the maximum values, 15 voltages and 7.5W respectively due to plasma flow with low conductivity and weak magnetic field.

  • PDF

Irradiation Induced Defects in a Si-doped GaN Single Crystal by Neutron Irradiation

  • Park, Il-Woo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.12 no.2
    • /
    • pp.74-80
    • /
    • 2008
  • The local structure of defects in undoped, Si-doped, and neutron irradiated free standing GaN bulk crystals, grown by hydride vapor phase epitaxy, has been investigated by employing electron magnetic resonance(EMR), Raman scattering and cathodoluminescence. The GaN samples were irradiated to a dose of $2{\times}10^{17}$ neutrons in an atomic reactor at Korea Atomic Energy Research Institute. There was no appreciable change in the Raman spectra for undoped GaN samples before and after neutron irradiation. However, a forbidden transition, $A_1$(TO) mode, appeared for a neutron irradiated Si-doped GaN crystal. Cathodoluminescence spectrum for the neutron irradiated Si-doped GaN crystal became much broader or was much more broadened than that for the unirradiated one. The observed EMR center with the g value of 1.952 in a neutron irradiated Si-doped GaN may be assigned to a Si-related complex donor.

An Investigation of Particle Detachment Ratios From Rotating Data Storage Disks (데이터 저장용 디스크의 회전 시 입자이탈에 관한 실험적 연구)

  • Park, Hee-Sung;Lee, Dae-Young;Hwang, Jung-Ho;Kim, Kwang;Jang, Dong-Sub
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.585-588
    • /
    • 2001
  • Particle contamination on the data storage disks has been a serious problem for magnetic hard disk drive manufacturers. For high storage optical disks, such as DVD-ROM/RAM or NFR (near field recording) system, particle-induced damages can be also detected because only a few micrometer particles can prevent read/write signal from optical lens. The increasing areal density and smaller bit size accelerates particle induced damages on the optical disk. One of the methods to prevent particle contamination on the optical disk surface is to handle the disk enclosed in a cartridge like a modern DVD-RAM disk. However, even for a perfectly sealed disk drive, particles are found inside the drive. The other method is to improve disk surface characteristics. Particle contamination on the surface can be reduced by proper selection of disk coating materials. [n this paper, particle detachment ratios for CD (compact disk), DVD (digital versatile disk), HD (magnetic hard disk), HD with Jut lubricant, and aluminosilicate substrate HD were investigated. Surface roughness and surface energy of the test disks were compared with the particle detachment ratios. Proper substrate and lubricant characteristics to reduce particle contamination on the disk surface were found.

  • PDF

Magnetic Field Calculation of Toroidal Winding with Circular Section (단면이 원형인 토로이드 권선의 자속밀도 계산)

  • Lee, Sang-Jin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.28-31
    • /
    • 2010
  • A magnetic field calculation method for toroidal type winding which has circular section was developed. At first, the equation for magnetic field by single filament coil was extended using numerical integration to estimate the entire interesting region of solenoid, especially winding region itself. And then, the magnetic field by toroidal arrangement of solenoids was computed with a coordinate transformation of vector fields. The superconducting magnet with toroidal arrangement can be made up of several tens of solenoid type double pancake windings for some applications such as superconducting magnetic energy storage system(SMES). In this system, the field calculation on the high-Tc superconducting(HTS) tape itself is very important because the entire system can be reached to a fault by magnetic stress of conductor or the critical current of superconducting tape can be dramatically reduced under its self field condition. To make matters worse, 3-dimensional analysis is indispensable for this type of magnet and the most of commercial programs with finite element method can be taken too much time for analysis and design. In this paper, a magnetic field calculation method for toroidal type winding with circular section was induced.

A Study on the Effects of Magnetic Field and BEP on Hyperlipidemia and Enzymatic Activities in Rats (자기장(磁氣場) 및 BEP 조사(照射)가 식이성(食餌性) 고지혈증(高脂血症)이 유발(誘發)된 흰쥐에 미치는 영향(影響)에 대(對)한 연구(硏究))

  • Koh, Kwang-chan;Lee, Cheol-wan
    • Journal of Haehwa Medicine
    • /
    • v.8 no.1
    • /
    • pp.559-592
    • /
    • 1999
  • It has been known that Ki(氣) energy is very effective on many adult diseases. Oriental Medicine has acknowledged Ki as an existing reality and investigated its effects on the body. However, the existence of Ki has not been fully explained. In order to find a conclusive evidence on the existence of Ki, this experiment was done to study the mutual relationship of Ki with a magnetic field and BEP (biological energy projector). The BEP apparatus was irradiated under the magnetic field on rats in the hyperlipidemic induced state. Following criterias were measured in this experiment: weight change, weight of the visceral organs, serum, hepatic lipid peroxide, bleeding time, tissue factor, and etc. The following results were obtained in this study: 1. The weight of rat significantly decreased in the magnetic field treated group and radically reduced in the group treated with both magnetic field and BEP. 2. The weight of liver, heart, and kidney increased in both the magnetic field treated group and magnetic field+BEP group compared to the normal group, but decreased in comparison to the control group. No changes were witnessed in the weight of spleen. 3. Serum and hepatic total cholesterol, total lipid, and lipid peroxide level significantly decreased in both magnetic field treated group and magnetic field+BEP treated group, while lipase activity has increased noticeably. 4. Serum HDL showed a significant increase in both magnetic field treated group and magnetic field+BEP treated group compared to the control group, while LDL and VLDL level decreased significantly. 5. A bleeding time significantly increased in both magnetic field treated group and magnetic field+BEP treated group compared to the control group. A tissue factor value of the lung decreased in the magnetic field treated group and magnetic field+BEP treated groups while increased in the control group. 6. Serum and hepatic lipid peroxide and glutathione level were significantly decreased in the magnetic field treated group and magnetic field+BEP treated group, while hepatic glutathione level was significantly increased compared to the control group. 7. A significant increase was found in the serum hydroxyl radical and SOD activity in the dietary hyperlipidemic rats, and significant decrease was found in the serum lipid peroxide content and superoxidase activity. 8. Hepatic cytosolic enzyme xanthine oxidase and aldehyde oxidase showed a significant decrease in the magnetic field treated group and magnetic field+BEP treated group. Through the above experimental results, one can suggest that the magnetic field with BEP can suppress hyperlipidemia and boost lipid metabolism and restructuring a lipid in liver, which increases the function of liver. To conclude, BEP is considered to show more potent effects under the exposure of magnetic field because magnetic field seems to increase the flow of Ki in the body.

  • PDF

Changes in Mechanical Properties and Magnetic Parameters of Neutron Irradiated Mn-Mo-Ni Low Alloy Steels (중성자에 조사된 Mn-Mo-Ni 저합금강의 기계적 및 자기적 성질 변화)

  • Jang, Gi-Ok;Ji, Se-Hwan;Park, Seung-Sik;Kim, Byeong-Cheol;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1020-1025
    • /
    • 1998
  • Irradiation-induced changes in mechanical properties and magnetic parameters were measured and compared to explore possible correlations for Mn-Mo-Ni low alloy steel surveillance specimens which were irradiated to a neutron fluence of $2.3\times10^{19}n/cm^2$(E>1.0MeV) in a typical pressurized water reactor environment at about $288^{\circ}C$. For mechanical property parameters, microvickers hardness, tensile and Charpy impact test were performed and Barkhausen noise amplitude, coercivity, remanence, maximum induction were measured for magnetic parameters. respectively. Results of mechanical property measurements showed an increase in yield and tensile strength, microvickers hardness. 41J indexed $RT_{NDT}$ and a decrease in upper shelf energy irrespective of base and weld metals. However, in the case of tensile properties, the changes in weld metal were negligible compared to the base metal. In the case of magnetic measurements, it is found that magnetic remanence, BN amplitude. BN energy have dropped significantly but coercivity(H,) has increased rapidly after irradiation. In this study. the measurements conducted on surveillance specimens of Mn-Mo-Ni low alloy steel showed that there were strong correlations between mechanical properties and magnetic properties.

  • PDF

Helicon Discharge Plasma Source and Laser Thomson Scattering System in KRISS

  • Seo, Byeong-Hun;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.149-149
    • /
    • 2012
  • We introduce Helicon discharge plasma source and Laser Thomson scattering system recently finished an installation in KRISS. Laser Thomson scattering method is promising for diagnostics in Helicon plasma because a measurement by electrical probe typically used has significant errors due to the gyromotion of electrons induced by high magnetic field. However, we found that LTS is affected by magnetic field so that we applied the normalization method for processing data and the results show a clear Maxwellian distribution at various conditions of magnetic field and RF power at low energy part without distortion.

  • PDF

Effects of Mn on Sulfur Segregation and Magnetic Induction in Thin-gauged 3%Si-Fe Strip (극박 3%규소강에서 Mn이 황의 편석 거동 및 자성특성에 미치는 효과)

  • 조성수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.917-920
    • /
    • 2001
  • Effects of addition of manganese and final reduction on segregation behavior of sulfur and final mangetic induction during final annealing have been investigated in the 300 ppm sulfur-contained 3% silicon-iron alloy strips with or without manganese. At the same concentration of sulfur, lower final reduction is favorable for final Goss texture. This is because the probability that the initial Goss grains survive under the highly segregated sulfur atmosphere and grow selectively within the segregated sulfur-free time range becomes higher. In the case of 3% silicon-iron with manganese, much lower magnetic induction was obtained, although the weak final reduction of 30% is given to the alloy, comparative to the 40%. This is because MnS particles acted as an reducer in the primary grain size.

  • PDF