• Title/Summary/Keyword: Magnetic transducer

Search Result 82, Processing Time 0.025 seconds

Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities (3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Choe, Bo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

MODE CONTROL OF GUIDED WAVE IN MAGNETIC HOLLOW CYLINDER USING ELECTROMAGNETIC ACOUSTIC TRANSDUCER ARRAY

  • FURUSAWA, AKINORI;KOJIMA, FUMIO;MORIKAWA, ATSUSHI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.2
    • /
    • pp.196-203
    • /
    • 2015
  • The aim of this work is to demonstrate a method for exciting and receiving torsional and longitudinal mode guided waves with an electromagnetic acoustic transducer (EMAT) ring array. First of all, a three-dimensional guided wave simulator is developed in order to numerically analyze the propagation of the guided wave. The finite difference time domain method is used for the simulator. Second, two guided wave testing systems using an EMAT ring array are provided: one is for torsional mode (T-mode) guided wave and the other is for longitudinal mode (L-mode). The EMATs used in the both systems are the same in design. A method to generate and receive the T- and L-mode guided waves with the same EMAT is proposed. Finally, experimental and numerical results are compared and discussed. The results of experiments and simulation agree well, showing the potential of the EMAT ring array as a mode controllable guided wave transmitter and receiver.

Development of Optical Pickup for ElectroAcoustic Guitar (일렉트로어쿠스틱 기타용 광 픽업의 개발)

  • Shin, Bong-Hi;Park, Young-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.417-422
    • /
    • 2014
  • A guitar pickup is a transducer that converts string vibration to an electrical signal. The magnetic and piezo pickups are the most commonly used for the respective electric and electroacoustic guitars. The magnetic pickups are prone to magnetic interference between the steel strings and permanent magnets, while the piezo ones are not free from signal inference between the strings. Thus, this paper presents the development of an optical pickup for the electroacoustic guitar. The proposed optical pickup has the top-to-bottom structure. It uses two of Infrared (IR) Light Emitting Diode (LED) and one photodetector. The developed optical pickup is subjected to the evaluation with commonly used piezoelectric pickup. It becomes obvious that SNR with the optical pickup is increased by 45 percent in average, compared with the piezoelectric pickup. It can be concluded that the developed optical pickup has a potential to be applied to the acoustic guitar.

Epitaxial Growth and Evaluation of Magnetic Garnet Films for Optical Current Transducers (광 CT용 자성 가넷 막의 에피택시 육성 및 평가)

  • Cho, Jae-Kyong
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.6
    • /
    • pp.246-252
    • /
    • 2007
  • This paper describes the effect of the mixing ratio of starting materials and the growth parameters of magnetic garnet films by LPE on the properties of the films and suggests the conditions to obtain the films suitable for the Faraday rotators of the optical CTs. The properties of the films investigated for the evaluation of the films were thickness, surface morphology, X-ray diffraction, lattice constant, lattice mismatch between film and substrate (single crystal nonmagnetic wafer), and Faraday rotation angle. Optical CTs have been fabricated and evaluated using the films grown.

Magnetic Resonance-Guided Focused Ultrasound : Current Status and Future Perspectives in Thermal Ablation and Blood-Brain Barrier Opening

  • Lee, Eun Jung;Fomenko, Anton;Lozano, Andres M.
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.10-26
    • /
    • 2019
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is an emerging new technology with considerable potential to treat various neurological diseases. With refinement of ultrasound transducer technology and integration with magnetic resonance imaging guidance, transcranial sonication of precise cerebral targets has become a therapeutic option. Intensity is a key determinant of ultrasound effects. High-intensity focused ultrasound can produce targeted lesions via thermal ablation of tissue. MRgFUS-mediated stereotactic ablation is non-invasive, incision-free, and confers immediate therapeutic effects. Since the US Food and Drug Administration approval of MRgFUS in 2016 for unilateral thalamotomy in medication-refractory essential tremor, studies on novel indications such as Parkinson's disease, psychiatric disease, and brain tumors are underway. MRgFUS is also used in the context of blood-brain barrier (BBB) opening at low intensities, in combination with intravenously-administered microbubbles. Preclinical studies show that MRgFUS-mediated BBB opening safely enhances the delivery of targeted chemotherapeutic agents to the brain and improves tumor control as well as survival. In addition, BBB opening has been shown to activate the innate immune system in animal models of Alzheimer's disease. Amyloid plaque clearance and promotion of neurogenesis in these studies suggest that MRgFUS-mediated BBB opening may be a new paradigm for neurodegenerative disease treatment in the future. Here, we review the current status of preclinical and clinical trials of MRgFUS-mediated thermal ablation and BBB opening, described their mechanisms of action, and discuss future prospects.

Characteristics of Magnetoelectric Composite with Rosen Type Piezoelectric Transducer Structure (Rosen형 압전 변압기 구조를 적용한 자기-전기 복합체의 특성)

  • Park, Sung Hoon;Yoon, Woon-Ha;Patil, Deepak Rajaram;Ryu, Jungho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.480-486
    • /
    • 2021
  • Magnetoelectric (ME) composite is composed of a piezoelectric material and a magnetostrictive material. Among various ME structures, 2-2 type layered ME composites are anticipated to be used as high-sensitivity magnetic field sensors and energy harvesting devices especially operating at its resonance modes. Rosen type piezoelectric transducer using piezoelectric material is known to amplify a small electrical input voltage to a large electrical output voltage. The output voltage of these Rosen type piezoelectric transducers can be further enhanced by modifying them into ME composite structures. Herein, we fabricated Rosen type ME composites by sandwiching Rosen type PMN-PZT single crystal between two Ni layers and studied their ME coupling. However, the voltage step-up ratio at the resonance frequency was found to be smaller than the value calculated with αME value. The ATILA FEA (Finite Elements Analysis) simulation results showed that the position of the nodal point was changed with the presence of a magnetostrictive layer. Thus, while designing a Rosen type ME composite with high performance in a resonant driving situation, it is necessary to optimize the position of the nodal point by optimizing the thickness or length of the magnetostrictive layer.

High-intensity focused ultrasound beam path visualization using ultrasound imaging (초음파 영상을 이용한 고강도 집중 초음파 빔 시각화)

  • Song, Jae Hee;Chang, Jin Ho;Yoo, Yang Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.1
    • /
    • pp.16-23
    • /
    • 2020
  • In High-Intensity Focused Ultrasound (HIFU) treatment, effective localization of HIFU focus is important for developing a safe treatment plan. While Magnetic Resonance Imaging guided HIFU (MRIgHIFU) can visualize the ultrasound path during the treatment for localizing HIFU focus, it is challenging in ultrasound imaging guided HIFU (USIgHIFU). In the present study, a real-time ultrasound beam visualization technique capable of localizing HIFU focus is presented for USIgHIFU. In the proposed method, a short pulse, with the same center frequency of an imaging ultrasound transducer below the regulated acoustic intensity (i.e., Ispta < 720 mW/㎠), was transmitted through a HIFU transducer whereupon backscattered signals were received by the imaging transducer. To visualize the HIFU beam path, the backscattered signals underwent dynamic receive focusing and subsequent echo processing. From in vitro experiments with bovine serum albumin gel phantoms, the HIFU beam path was clearly depicted with low acoustic intensity (i.e., Ispta of 94.8 mW/㎠) and the HIFU focus was successfully localized before any damages were produced. This result indicates that the proposed ultrasound beam path visualization method can be used for localizing the HIFU focus in real time while minimizing unwanted tissue damage in USIgHIFU treatment.

The Development of Detection System of Conveyer Belt Damage using Magnetic Flux (자기장을 이용한 컨베이어 벨트 파손 감지장치 개발)

  • Yang, Keun-Ho;Min, Byung-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.6
    • /
    • pp.815-822
    • /
    • 2013
  • In this paper, the research is to develop a system that can detect the breakage of the rubber belt conveyor system in the transport of the raw materials required for the operation of logistics. We are to develop a system that can detect the breakage of the belt due to the electronic system of belt breakage occurs by placing the material on the inside of the belt, electric induction to minimize the damage of the belt. The belt repair costs, or reorder the steps of the logistics transit time can be reduced. Induced in the coil, and belt embedded in the transmitted signal as a way to detect the breakage of the belt was to detect the damage of the belt by detecting the electrical phenomena induced in the coil at the receiving end.

Design and Fabrication of EMAT for Excitation of SAW (SAW 여기를 위한 EMAT의 설계 및 제작에 관한 연구)

  • Kim, Heung-Ki;Lee, Jae-Seung;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.24-30
    • /
    • 1990
  • In this paper, meander line type EMAT(Electro-Magnetic Acoustic Transducer) has been designed and fabricated with effective properties for detecting flaw existing within one wavelength in depth, and its characteristics have been analyzed. For the purpose of getting effective dynamic and static magnetic intensity, the coil has been arrayed using wire with interval of 0.75 mm and width of 0.65 mm and permanent magnets with 1500 Gauss have been constructed respectively. The center frequency and fractional bandwidth of the fabricated EMAT was 2 MHz and 36% respectively and its impulse response has been measured by non-contacting technique(the distance between the conducting media and the coil was 0.15mm). In the measuring results, it has been shown that Insertion Loss(IL) was 45.46dB and it was good agreement with theoretical result.

  • PDF

Vector Control of PM Motor without any Rotational Transducer PART 1 - Surface Mounted Permanent Magnet Motor (위치 검출기가 없는 영구자석 동기 전동기의 제어 PART1 - 표면부착형 영구자석 전동기)

  • Jang, Ji-Hun;Ha, Jeong-Ik;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.453-458
    • /
    • 2001
  • This paper presents a new vector control algorithm of the surface mounted permanent magnet motor (SMPMM) without any rotational tranceducer. Originally, SMPMM does not have any magnetic saliency in structure, but it has a little magnetic saliency due to the saturation by the flux of the permanent magnet. Moreover, it varies according to the load conditions and the control performance of schematics using the saliency can be easily degraded. To prevent it and to improve the performance of the proposed algorithm, the saliency of a SMPMM under various load conditions is analyzed. In the proposed algorithm, the saliency or the impedance difference related to the saliency is utilized in order to estimate the position and speed of the rotor. And the high frequency signal is injected into the motor to measure the impedance difference and also to enhance the control performance of the system. The experimental results verify the performance of the proposed sensorless algorithm.

  • PDF