• Title/Summary/Keyword: Magnetic resonance imaging (MR)

Search Result 892, Processing Time 0.293 seconds

Quantitative Evaluation of Optimized Fat-Suppression Techniques for T1 Weighted Cervical Spine MR Imaging: Comparison of TSE-CHESS and TSE-SPAIR (T1 강조 경추자기공명영상에 대한 최적의 지방소거기법의 정량적 평가: TSE-CHESS 과 TSE-SPAIR 의 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.529-536
    • /
    • 2013
  • The purpose of this study is to know clinical usefulness for fat suppression of the body curved portion compared with TSE-CHESS and TSE-SPAIR technique. A total of 25 normal volunteers without cervical spine disease were studied on a 3.0 T MRI scanner. As a quantitative analysis, PSNRs and CNRs were evaluated by using two methods for fat suppression of the body curved portion. As a results, PSNRs and CNRs for fat suppression were significantly greater for the TSE-SPAIR technique compared to TSE-CHESS technique. In conclusion, this study showed that a TSE-SPAIR technique has improved PSNRs and CNRs for evaluating of fat suppression in the body curved portion. These conclusions in the future will be provided information in diagnosis of fat suppression for the body curved portion.

Enhancement Characteristics of Gadolinium Contrast Agent in the Rat Inner Ear Perilymph through CSF microcirculation (뇌척수액 미세순환을 통한 래트 내이 외림프의 가돌리늄 조영제 증강 특성)

  • Kim, Min Jung;Lee, Sang-Yeol;Lee, Hui Joong;Lee, Taekwan;Chang, Yongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.193-198
    • /
    • 2022
  • Contrast enhanced magnetic resonance imaging using gadolinium-based contrast agent (GBCA) is a very useful in vivo technique to visualize the inner ear pathology including endolymphatic hydrops. Although systemic intravenous (IV) administration can visualize the perilymph space, the visualization was possible by indirect passage of contrast agent through blood-perilymph barrier. All animal experimental procedures were performed under anesthesia with 5% isoflurane. Lipopolysaccharide (LPS) was instilled into the left tympanic cavity through the tympanic membrane using a sterile 27gauge needle to induce hydrops model. Tucker-Davis Technologies system was used to measure Auditory Brainstem Responses (ABRs). For intracerebroven-tricular (ICV) administration, 25 µmol of GADOVIST (Bayer, Berlin, Germany) was used and diluted GADOVIST injection was 10 µl. MR imaging was acquired with a 9.4 Tesla MRI scanner. Transmit-receive volume coil with 40 mm inner diameter and 75 mm out diameter was used. ICV administration well demonstrated the strong enhancement along the cerebrospinal fluid (CSF) microcirculation pathway including CSF fluid in the subarachnoid space and CSF space of the inner ear structures. On the other hand, IV administration showed no contrast enhancement along the CSF microcirculation pathway and showed weak enhancement in the inner ear structures. In case of rat hydrops model, ICV administration showed that the reduced contrast enhancement in the perilymph space of the hydrops induced inner ear compared to the contrast enhancement in the perilymph space of the normal inner ear. New systemic ICV administration method provide contrast enhancement of GBCA in the inner ear through CSF microcirculation pathway.

Preoperative Detection of Hepatic Metastases from the colorectal Cancers: Comparison of Dual-phase CT scan, Mn-DPDP enhanced MRI, and combination of CT and MRI (대장암의 간 전이 진단: 이중시기 CT, Mn-DPDP 조영증강 MRI, 그리고 CT-MRI 종합 판독의 비교)

  • Shin, Kyung-Min;Kim, Jong-Yeol;Choi, Gyu-Seok;Kim, Hye-Jeong;Lee, Jong-Min;Chang, Yong-Min;Kim, Yong-Seon;Kang, Duk-Sik;Ryeom, Hun-Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • Purpose : To determine the usefulness of additional Mn-DPDP MRI for preoperative evaluation of the patients with colorectal cancers by comparison of dual-phase CT scan, Mn-DPDP enhanced MRI and combination of CT and MRI. Materials and Methods : Fifty-three colorectal cancer patients with 92 metastatic nodules underwent dualphase (arterial and portal) helical CT scan and Mn-DPDP MRI prior to surgery. The indication of MRI was presence or suspected of having metastatic lesions at CT scan and/or increased serum carcinoembryonic antigen (CEA) levels (10 ng/mL or more). The diagnosis was established by the combination of findings at surgery, intraoperative ultrasonography, and histopathologic examination. Two radiologists interpreted CT, MRI, and combination of CT-MRI at discrete sessions and evaluated each lesion for location, size, and intrinsic characteristics. The lesions were divided into three groups according to their diameter; 1cm<, 1-2 cm, and >2 cm. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method. Detection and false positive rate were also evaluated. Results : In the lesions smaller than 1 cm, detection rate of combined CT-MRI was superior to CT or MRI alone (82%, p=0.036). The mean accuracy (Az values) of combined CT and MRI was significantly higher than that of CT in the lesions smaller than 2 cm (1 cm<, p=0.034; 1-2 cm, p=0.045). However, there was no significant difference between MRI and combined CT-MRI. The false positive rate of CT was higher than those of combined CT-MR in the lesions smaller than 1 cm (28%, p=0.023). Conclusion : Additional MRI using Mn-DPDP besides routine CT scan was helpful in differentiating the hepatic lesions (<2 cm) and could improve detection of the small hepatic metastases (<1 cm) from colorectal carcinoma.

  • PDF

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

Cerebellar Activation Related to Various Tasks Using fMRI (다양한 임무 부여시 기능적 자기공명영상에서 관찰된 소뇌의 활성화)

  • Hwang, Seung-Bae;Kwak, Hyo-Sung;Lee, Sang-Yong;Jin, Gong-Yong;Han, Young-Min;Kim, Young-Kon;Chung, Gyung-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.47-53
    • /
    • 2009
  • Purpose : Although it's been known for half a century that unique structures have evolved in the cerebellum and they then became greatly enlarged in the human brain, the function of these structures still remains unknown. The purpose of this study was to assess cerebellar activation during motor, sensory, word generation, listening comprehension, and working memory tasks with using functional magnetic resonance imaging (fMRI). Materials and Methods : Eleven healthy right-handed subjects (Male: female, 6:5, mean age: 27.4years) were imaged on a Siemens 1.5T scanner. Whole brain functional maps were acquired using BOLD EPI sequences in the axial plane. Each paradigm consisted of five epochs of activation vs. the control condition. The activation tasks consisted of left finger complex movement, sensory stimulation of the left hand, word generation, listening comprehension, and working memory tasks. The reference function was a boxcar waveform. The activation maps were thresholded at p = 0.001. SPM 5 evaluated the activated areas and responses within the cerebellum. Results : Cerebellar activation was observed on motor task, word generation task, and working memory task. There were 949 activated areas and the mean fitted and adjusted response was 0.68 during the motor task. There were 319 activated areas and the mean fitted and adjusted response was 0.15 during the word generation task. There were 330 activated areas and the mean fitted and adjusted response was 0.26 during the working memory task. Conclusion : Our results suggest that the cerebellum is involved in a variety of functional tasks, including motor, word generation, and working memory tasks. However, during the motor task, the cerebellum showed a large activated area and a high response. Cerebellar function can be evaluated by fMRI.

  • PDF

Hepatic Venous Return in Atrial Isomerism Evaluated by MR (심방 이성체 환자의 간정맥 환류에 대한 자기공명영상 소견)

  • 홍용국;박영환
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.493-500
    • /
    • 1997
  • We performed this study to evaluate hepatic venous drainage in atrial isomerism by MR and the clinical significance of anomalous hepatic venous return in total cavopulmonary shunt operation. Numbers and locations of hepatic veins in twenty-two patients with isomerism(thirteen with right isomerism and nine with left isom rism) were evaluated by MR. Operative procedure of hepatic veins and postoperative arterial oxygen saturation were compared with hepatic vein connection in six patients after total cavopulmonary shunt operation. Among nine patients with left isomerism, hepatic venous return was totally anomalous via a single opening in eight, and via two separate openings in one. Among thirteen patients with right isomerism, partial anomalous hepatic venous connection directly to the atrium was seen in four. One showed total anomalous hepatic venous connection to atrium through one opening. Total cavopulmonary shunt operation was performed in 6 patients. Hepatic veins were connected to pulmonary arteries in four patients who had one atrial opening of hepatic vein andlor IVC, or two ipsilateral atrial opening of hepatic veins and IVC. In conclusion, hepatic vein drainage to atrium is variable in atrial isomerism. MR is useful for evaluation of hepatic vein drainage in atrial isomerism and surgical pla ning.

  • PDF

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF

Reparative, Neuroprotective and Anti-neurodegenerative Effects of Granulocyte Colony Stimulating Factor in Radiation-Induced Brain Injury Model

  • Gokhan Gurkan;Ozum Atasoy;Nilsu Cini;Ibrahim Halil Sever;Bahattin Ozkul;Gokhan Yaprak;Cansin Sirin;Yigit Uyanikgil;Ceren Kizmazoglu;Mumin Alper Erdogan;Oytun Erbas
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.5
    • /
    • pp.511-524
    • /
    • 2023
  • Objective : This animal model aimed to compare the rat group that received brain irradiation and did not receive additional treatment (only saline) and the rat group that underwent brain irradiation and received Granulocyte colony stimulating factor (G-CSF) treatment. In addition, the effects of G-CSF on brain functions were examined by magnetic resonance (MR) imaging and histopathologically. Methods : This study used 24 female Wistar albino rats. Drug administration (saline or G-CSF) was started at the beginning of the study and continued for 15 days after whole-brain radiotherapy (WBRT). WBRT was given on day 7 of the start of the study. At the end of 15 days, the behavioral tests, including the three-chamber sociability test, open field test, and passive avoidance learning test, were done. After the behavioral test, the animals performed the MR spectroscopy procedure. At the end of the study, cervical dislocation was applied to all animals. Results : G-CSF treatment positively affected the results of the three-chamber sociability test, open-space test and passive avoidance learning test, cornu Ammonis (CA) 1, CA3, and Purkinje neuron counts, and the brain levels of brain-derived neurotrophic factor and postsynaptic density protein-95. However, G-CSF treatment reduced the glial fibrillary acidic protein immunostaining index and brain levels of malondialdehyde, tumor necrosis factor-alpha, nuclear factor kappa-B, and lactate. In addition, on MR spectroscopy, G-CSF had a reversible effect on brain lactate levels. Conclusion : In this first designed brain irradiation animal model, which evaluated G-CSF effects, we observed that G-CSF had reparative, neuroprotective and anti-neurodegenerative effects and had increased neurotrophic factor expression, neuronal counts, and morphology changes. In addition, G-CSF had a proven lactate-lowering effect in MR spectroscopy and brain materials.

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF