• Title/Summary/Keyword: Magnetic resonance images

Search Result 1,124, Processing Time 0.049 seconds

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Unusual Brain Computed Tomography Artifact in Cerebellum Mimicking Hemorrhage: A Case Report (뇌 CT에서 출혈로 오인된 소뇌의 허상: 증례보고)

  • Lee, Jihun;Eom, Ki Seong;Kim, Tae-Young
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.195-197
    • /
    • 2015
  • Artifacts can seriously degrade the quality of computed tomography (CT) images, sometimes to the point of making them diagnostically unusable. Here, we report an unusual CT artifact that could have resulted in the misdiagnosis of a hyperdense hemorrhagic lesion in a 55-year-old man. The author recommend that when hemorrhagic lesion in posterior fossa is suggested on CT, the physician should carefully consider all patient-related clinical data prior to considering surgical intervention or a biopsy. Cranial magnetic resonance imaging (MRI) can help in preventing the misdiagnosis as hemorrhage of CT scan.

  • PDF

A NOTE ON OPTIMAL RECONSTRUCTION OF MAGNETIC RESONANCE IMAGES FROM NON-UNIFORM SAMPLES IN k-SPACE

  • Lee, June-Yub
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.14 no.1
    • /
    • pp.35-42
    • /
    • 2010
  • A goal of Magnetic Resonance Imaging is reproducing a spatial map of the effective spin density from the measured Fourier coefficients of a specimen. The imaging procedure can be done by inverse Fourier transformation or backward fast Fourier transformation if the data are sampled on a regular grid in frequency space; however, it is still a challenging question how to reconstruct an image from a finite set of Fourier data on irregular points in k-space. In this paper, we describe some mathematical and numerical properties of imaging techniques from non-uniform MR data using the pseudo-inverse or the diagonal-inverse weight matrix. This note is written as an easy guide to readers interested in the non-uniform MRI techniques and it basically follows the ideas given in the paper by Greengard-Lee-Inati [10, 11].

Chronic Spinal Epidural Hematoma Related to Kummell's Disease

  • Kim, Heyun-Sung;Lee, Seok-Ki;Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.231-233
    • /
    • 2011
  • Chronic spinal epidural hematoma related to Kummell's disease is extremely rare. An 82-year-old woman who had been managed conservatively for seven weeks with the diagnosis of a multi-level osteoporotic compression fracture was transferred to our institute. Lumbar spine magnetic resonance images revealed vertebral body collapse with the formation of a cavitary lesion at L1, and a chronic spinal epidural hematoma extending from L1 to L3. Because of intractable back pain, a percutaneous vertebroplasty was performed. The pain improved dramatically and follow-up magnetic resonance imaging obtained three days after the procedure showed a nearly complete resolution of the hematoma. Here, we present the rare case of a chronic spinal epidural hematoma associated with Kummell's disease and discuss the possible mechanism.

A Vowel Discrimination of Korean Monophthongs [i, e, a, o, u, ${\omega}$] Using Vocal Tract Magnetic Resonance Image and F1/F2 (성도 자기공명 영상과 음향정보(F1/F2)를 이용한 한국어 단모음 [이, 에, 아, 오, 우, 으] 판별)

  • Seong, Cheol-Jae;Park, Jong-Won;Kim, Gui-Ryong
    • MALSORI
    • /
    • no.56
    • /
    • pp.103-125
    • /
    • 2005
  • We present a new method of measuring the volume and cross-sectional area of the vocal tract from magnetic resonance images. The vocal tract was divided by the 2 constriction points on the horizontal and vertical planes. The ratios of the volumes of the segment vocal tracts to that of the entire vocal tract play a crucial role in discriminating Korean monophthongs in that vowels were successfully discriminated by the ratios. The discriminant analysis also demonstrated that the acoustic parameters F1 and F2, in addition to the segment volumes, serve as significant parameters in discriminating Korean monophthongs.

  • PDF

Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering (대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

Bilateral Striopallidodentate Salcinosis on CT and MRI : Case Report (양측성 선조-담창-치상액 석회증의 전산화단층촬영과 자기공명영상 소견 : 증례보고)

  • Lee Jong Deok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.621-625
    • /
    • 2004
  • Bilateral striopallidodentate calcinosis, popularly referred to as Fahr's disease, is a disorder radiologically characterized by bilateral calcifications of the basal ganglia, thalami, dentate nuclei of the cerebellum, and the white matter of the cerebral hemisphere without serum calcium-phosphorus metabolism and related endocrinologic abnormalities. Intracranial calcifications are easily visible as high-density on CT. On magnetic resonance images, the calcifications exhibit different signal intensities. The differences in signal intensity are thought to be related to the stage of the disease, differences in calcium metabolism, and the volume of the calcium deposit. Based on literature review, I report the case of a 63 year man with bilateral symmetrical calcification in the basal ganglia, dentate nuclei of the cerebellum, and the white matter of the cerebral hemisphere who present a 5 year history of progressive dysarthria associated with left thalamic infarction.

Measurement of Flow Velocity and Flow Visualization with MR PC Image (MR PC 영상을 이용한 유체 흐름 분석)

  • Kim, S.J.;Lee, D.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF

Morphological Operations to Segment a Tumor from a Magnetic Resonance Image

  • Thapaliya, Kiran;Kwon, Goo-Rak
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.1
    • /
    • pp.60-65
    • /
    • 2014
  • This paper describes an efficient framework for the extraction of a brain tumor from magnetic resonance (MR) images. Before the segmentation process, a median filter is used to filter the image. Then, the morphological gradient is computed and added to the filtered image for intensity enhancement. After the enhancement process, the thresholding value is calculated using the mean and the standard deviation of the image. This thresholding value is used to binarize the image followed by the morphological operations. Moreover, the combination of these morphological operations allows to compute the local thresholding image supported by a flood-fill algorithm and a pixel replacement process to extract the tumor from the brain. Thus, this framework provides a new source of evidence in the field of segmentation that the specialist can aggregate with the segmentation results in order to soften his/her own decision.

MR Contrast Agents and Molecular Imaging (MR조영제와 분자영상)

  • Moon, Woo-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.2
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.