• Title/Summary/Keyword: Magnetic resonance (MR)

Search Result 1,187, Processing Time 0.025 seconds

MR Findings of Seizure-Related Cerebral Cortical Lesions during Periictal Period

  • Kim, Na Yoon;Baek, Hye Jin;Choi, Dae Seob;Ha, Jee Young;Shin, Hwa Seon;Kim, Ju Ho;Choi, Ho Cheol;Kim, Ji Eun;Park, Mi Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.82-90
    • /
    • 2017
  • Purpose: This study investigated the MRI, MR angiography (MRA) and MR perfusion findings of seizure-related cerebral cortical lesions during the periictal period. Materials and Methods: From a retrospective review of the institutional database between 2011 and 2014, a total of 21 patients were included in this study. Two radiologists assessed periictal MRI, including MRA and MR perfusion, in patients with seizure-related cortical lesions. The parameters examined include: location of cortical abnormality, multiplicity of the affected cortical region, cerebral vascular dilatation, perfusion abnormality and other parenchymal lesions. Results: All patients showed T2 hyperintense cerebral cortical lesions with accompanying diffusion restriction, either unilateral (18/21, 85.7%) or bilateral (3/21, 14.3%). Of the 21 patients enrolled, 10 (47.6%) had concurrent T2 hyperintense thalamic lesions, and 10 (47.6%) showed hippocampal involvement. Of the 17 patients (81%) who underwent MRA, 13 (76.5%) showed vascular dilatation with increased flow signal in the cerebral arteries of the affected cortical regions. On MR perfusion, all 5 patients showed cortical hyperperfusion, corresponding to the region of cortical abnormalities. Conclusion: Seizure-related cerebral cortical lesions are characterized by T2 and diffusion hyperintensities, with corresponding cerebral hyperperfusion and vascular dilatation. These findings can be helpful for making an accurate diagnosis in patients with seizure.

Comparative Study on the Power Transfer Efficiency of Magnetic Resonance and Radio Frequency Wireless Power Transmission

  • Kim, Ye-Chan;Choi, Bo-Hee;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.232-234
    • /
    • 2016
  • In this paper, the power transfer efficiencies (PTEs) of magnetic resonance (MR) wireless power transmission (WPT) and radio frequency (RF) WPT are compared as a function of the distances between resonators (or antennas). The PTE of the C-loaded loop resonators during MR WPT was theoretically calculated and simulated at 6.78MHz, showing good agreement. The PTE of the patch antennas, whose area is the same as the C-loaded loop resonator during MR WPT, was theoretically calculated using the Friis equation and the equation by N. Shinohara and simulated at 5.8 GHz. The three results from the Friis equation, the equation by N. Shinohara, and from a full wave simulation are in strong agreement. The PTEs, when using the same size resonators and antennas are compared by considering the distance between the receiver and transmitter. The compared results show that the MR WPT PTE is higher than that of the RF WPT PTE when the distance (r) between the resonators (or antennas) is shorter. However, the RF WPT PTE is much higher than that of the MR WPT PTE when the distance (r) between the resonators (or antennas) is longer since the RF WPT PTE is proportional to $r^{-2}$ while the MR WPT PTE is proportional to $r^{-6}$.

Morphologic Assessment of Corpus Callosum in the Patient of Alzheimer Disease using Magnetic Resonance Imaging

  • Seoung, Youl-Hun;Choe, Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.13 no.2
    • /
    • pp.84-95
    • /
    • 2009
  • The purpose of this study was to evaluate the usefulness of the measurement of corpus callosum (CC) size in the Alzheimer patient by using magnetic resonance (MR) midsagittal image. We performed MR scanning in 20 normal high age group, and in 20 mild cognitive impairment (MCI) group, and in 20 Alzheimer disease (AD) group. The following parameters were employed in AD group: TRITE/FA 6650ms/66ms/$90^{\circ}$, NEX 2, Thickness/Gap 2/0, FOV 220mm. The magnetic field strength was used at 3.0 Tesla. We selected midsagittal image of the brain by using view forum program, measured CC size, which were anteroposterior length, diameter of genu, body, narrowing portion, and splenium. The present study demonstrates that CC size of Alzheimer disease can be useful for clinical assessment concerning the diameter of genu, body, and splenium.

Efficient Experimental Design for Measuring Magnetic Susceptibility of Arbitrarily Shaped Materials by MRI

  • Hwang, Seon-ha;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.3
    • /
    • pp.141-149
    • /
    • 2018
  • Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The $B_0$ maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled $B_0$ map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MR-visible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.

In-vivo $^1H$ MR Spectroscopy in Abscessess Induced in Rabbit Thighs: Evaluation of Treatment Effect (토끼 대퇴부에 유발한 농양의 생체내 수소 자기공명분광법: 치료효과 평가)

  • 구진모;장기현;이경호;한문희;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.31-38
    • /
    • 2003
  • Purpose : To analyze the serial changes of proton magnetic resonance (MR) spectra in the abscess and to determine the effect of the antibiotic treatment on the metabolite patterns. Materials and Methods : MR imaging and MR spectroscopy of an experimentally induced abscess were performed sequentially for four weeks at interval of one week in both the control group (n=5) and the antibiotic treatment group (n=5). On MR imaging, the shape and the size of the abscess were analyzed. On MR spectroscopy, the resonance peaks of metabolites were assigned on the basis of reported peaks in the literature. The metabolite ratios measured by using N-acetyl alanine as an external reference and by using lipid as an internal reference were compared in both the control and treatment g roups. Results : The abscesses were seen as cystic masses on MR imaging. On MR spectroscopy, the variable peaks of acetate, succinate and various amino acids, which are the metabolites of infection, were identified in the control and antibiotic treatment groups. The most frequent peak was that of acetate at 1.92ppm (70%). Both the peak ratios of acetate to lipid and acetate to external reference tended to decrease in the treatment group while the ratios did not change significantly in the control group. Conclusion : MR spectroscopy is useful not only for the diagnosis of abscess but also for monitoring the evolution of the abscess by using the acetate peak.

  • PDF

Magnetic Resonance Imaging Using Matching Pursuit (Matching Pursuit 방법을 이용한 MR영상법에 관한 연구)

  • Ro, Y.M.;Zakhora, Avideh
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.230-234
    • /
    • 1997
  • The matching pursuit (MP) algorithm developed by S. Mallat and Z. Zhang is applied to magnetic resonance (MR) imaging. Since matching pursuit is a greedy algorithm to find waveforms which are the best match for an object-signal, the signal can be decomposed with a few iterations. In this paper, we propose an application of the MP algorithm to the MR imaging to reduce imaging time. Inner products of residual signals and selected waveforms in the MP algorithm are derived from the MR signals by excitation of RF pulses which are fourier transforms of selected waveforms. Results from computer simulations demonstrate that the imaging time is reduced by using the MP algorithm and further a progressive reconstruction can be achieved.

  • PDF

Basic Principles of MR

  • 김성은
    • Proceedings of the KSMRM Conference
    • /
    • 1999.04a
    • /
    • pp.1-9
    • /
    • 1999
  • 핵자기 공명(NMR:nuclear magnetic resonance)은 19451건 Bloch, Procell등에 의해 처음으로 실험적으로 입증된 후에 생화학 및 약학 분야에서 분자단위의 물질의 성분, 구조, 대사물질의 역학적 운동 및 상태에 관한 정보를 아는데 유용한 기법으로 사용 되어 왔다. 의학분야에서는 Lauterber등에 의해 자기공명영상볍(Magnetic Resonance Imaging:MRI)으로 개발되어 질병의 진단 및 치료에 많은 공헌을 하게되었다. 해부학적영상 뿐 아니라 분석방법으로 병변 부위 및 인체 기관에서의 각종 대사물질의 정량적인 양과 변화를 알 수 있는 자기공명분광기법(magnetic resonance spectroscopy:MRS)도 활발한 임상적용이 이루어지고 있다. 자기공명영상법의 활발한 임상적 응용 및 새로운 technique이해를 위해서는 물리학적 개념(MR Physics)을 이해하는 것이 매우 중요하다.

  • PDF

MRI Imaging of Simultaneously Developed Endogenous Endophthalmitis and Brain Abscesses (동시에 병발한 내인성안구염과 뇌농양의 자기공명영상)

  • Kim, Young Hwan;Chang, Hyuk Won;Kim, Mi Jung;Jung, Hye-Ra;Cho, Jihyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.47-49
    • /
    • 2013
  • Endogenous endophthalmitis is rare and refers to an intraocular inflammatory process that may result from exogenous or endogenous causes. Magnetic resonance imaging (MRI) is useful for diagnosing endophthalmitis, and valuable to reach the diagnosis of brain abscess. We report here the MR findings of simultaneously developed endogenous endophthalmitis and brain abscesses.