• Title/Summary/Keyword: Magnetic resonance (MR), contrast media

Search Result 20, Processing Time 0.031 seconds

Effectiveness of MR Urography in the Evaluation of Kidney which Failed to Opacify during Excretory Urography: Comparison with Ultrasonography

  • Sung-Il Hwang;Seung Hyup Kim;Young Jun Kim;Ah Young Kim;Jung Yun Cho;Joon Woo Lee;Hyung-Seok Kim;Kyung Mo Yeon
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.152-158
    • /
    • 2000
  • Objective: The purpose of this study was to compare the effectiveness of MR urography (MRU) with that of ultrasonography (US) in the evaluation of urinary tract when this failed to opacify during excretory urography (EXU). Materials and Methods: Twelve urinary tracts in 11 patients were studied. In each case, during EXU, the urinary system failed to opacify within one hour of the injection of contrast media, and US revealed dilatation of the pelvocalyceal system. Patients underwent MRU, using a HASTE sequence with the breath-hold technique; multi-slice acquisition was then performed, and the images were reconstructed using maximal intensity projection. Each set of images was evaluated by three radiologists to determine the presence, level, and cause of urinary tract obstruction. Results: Obstruction was present in all twelve cases, and in all of these, MRU accurately demonstrated its level. In this respect, however, US was successful in only ten. The cause of obstruction was determined by MRU in eight cases, but by US in only six. In all of these six, MRU also successfully demonstrated the cause. Conclusion: MRU is an effective modality for evaluation of the urinary tract when this fails to opacify during EXU, and appears to be superior to US in demonstrating the level and cause of obstruction.

  • PDF

Quantitative Analysis of Brain Metabolite Spectrum Depending on the Concentration of the Contrast Media in Phantom (팬텀 내 조영제 농도에 따른 뇌 대사물질 Spectrum의 정량분석)

  • Shin, WoonJae;Gang, EunBo;Chun, SongI
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 2015
  • Quantitative analysis of MR spectrum depending on mole concentration of the contrast media in cereberal metabolite phantom was performed. PRESS pulse sequence was used to obtain MR spectrum at 3.0T MRI system (Archieva, Philips Healthcare, Best, Netherland), and the phantom contains brain metabolites such as N-Acetyl Asparatate (NAA), Choline (Cho), Creatine (Cr) and Lactate (Lac). In this study, optimization of MRS PRESS pulse sequency depending on the concentration of contrast media (0, 0.1 and $0.3mmol/{\ell}$) was evaluated for various repetition time(TR; 1500, 1700 and 2000 ms). In control (cotrast-media-free) group, NAA and Cho signals were the highest at TR 2000 ms than at 1700 and 1500 ms. Cr had the highest peak signal at TR 1500 ms. When concentration of contrast media was $0.1mmol/{\ell}$, the metabolites were increased NAA 73%, Cho 249%, Cr 37% at TR 1700 ms compared with other TR, and also signal increased at $0.3mmol/{\ell}$, In $0.5mmol/{\ell}$ of contrast agent, cerebral metabolite peaks reduced, especially when TR 1500 ms and 2000 ms they decreased below those of control group. The ratio of metabolite peaks such as NAA/Cr and Cho/Cr decreased as the concentration of the contrast agent increased from 0.1 to $0.5mmol/{\ell}$. Authors found that the optimization of PRESS sequence for 0.3T MRS was as follows: low density of contrast agent ($0.1mmol/{\ell}$ and $0.3mmol/{\ell}$) made the highest signal intensity, while high density of contrast agent reveals the least reduction of signal intensity at 1700 ms. In conclusion, authors believe that it is helpful to reduce TR for acquiring maximum signal intensity.

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

Evaluation of Optimal Combination of Commercially Available Superparamagnetic Iron Oxide Nanoparticles and Transfection Agents for Labelling of Human Mesenchymal Stem Cells (인체 중간엽 줄기세포의 표지를 위한 상용화 된 Superparamagnetic Iron Oxide Nanoparticle과 Tansfection Agent의 적절한 병용을 위한 연구)

  • Kim, Sung-Hun;Oh, Soon-Nam;Park, Youn-Hee;Kang, Won-Kyung;Ahn, Kook-Jin;Chung, Soo-Kyo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 2012
  • Purpose : To determine the optimal combination of commercially available superparamagnetic iron oxide (SPIO) nanoparticles with transfection agents (TA). Materials and Methods: Protamine sulfate (Pro) and poly-L-lysin (PLL) were incubated with ferumoxide and ferucarbotran in human mesenchymal stem cells at various concentrations, and cellular viability were evaluated. Cellular iron uptake was qualitatively and quantitatively evaluated. Cell visibility was assessed via MR imaging and the T2-relaxation time was calculated. Results: The cellular viabilities with ferucarbotran were more significantly decreased than those with ferumoxide (p < 0.05). Iron uptake with ferumoxide was significantly higher than that for those with with ferucarbotran. The T2-relaxation time was observed to be shorter with ferumoxide in comparison to those with ferucarbotran (p < 0.05). Ferumoxide at a concentration of 25 ${\mu}g$/ml in combination with either Pro or PLL at a concentration of 3.0 ${\mu}g$/ml did not adversely impact cell viability, maximized iron uptake, and exhibited a lower T2-relaxation time in comparison to other combinations. Conclusion: Stem cells with ferumoxide exhibited a higher cellular viability and iron uptake in comparison to ferucarbotran-treated stem cells. A 25 ${\mu}g$/ml of ferumoxide with a 3.0 ${\mu}g$/ml of TA is sufficient to label mesenchymal stem cells.

Assessment of Additional MRI-Detected Breast Lesions Using the Quantitative Analysis of Contrast-Enhanced Ultrasound Scans and Its Comparability with Dynamic Contrast-Enhanced MRI Findings of the Breast (유방자기공명영상에서 추가적으로 발견된 유방 병소에 대한 조영증강 초음파의 정량적 분석을 통한 진단 능력 평가와 동적 조영증강 유방 자기공명영상 결과와의 비교)

  • Sei Young Lee;Ok Hee Woo;Hye Seon Shin;Sung Eun Song;Kyu Ran Cho;Bo Kyoung Seo;Soon Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.889-902
    • /
    • 2021
  • Purpose To assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) for additional MR-detected enhancing lesions and to determine whether or not kinetic pattern results comparable to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast can be obtained using the quantitative analysis of CEUS. Materials and Methods In this single-center prospective study, a total of 71 additional MR-detected breast lesions were included. CEUS examination was performed, and lesions were categorized according to the Breast Imaging-Reporting and Data System (BI-RADS). The sensitivity, specificity, and diagnostic accuracy of CEUS were calculated by comparing the BI-RADS category to the final pathology results. The degree of agreement between CEUS and DCE-MRI kinetic patterns was evaluated using weighted kappa. Results On CEUS, 46 lesions were assigned as BI-RADS category 4B, 4C, or 5, while 25 lesions category 3 or 4A. The diagnostic performance of CEUS for enhancing lesions on DCE-MRI was excellent, with 84.9% sensitivity, 94.4% specificity, and 97.8% positive predictive value. A total of 57/71 (80%) lesions had correlating kinetic patterns and showed good agreement (weighted kappa = 0.66) between CEUS and DCE-MRI. Benign lesions showed excellent agreement (weighted kappa = 0.84), and invasive ductal carcinoma (IDC) showed good agreement (weighted kappa = 0.69). Conclusion The diagnostic performance of CEUS for additional MR-detected breast lesions was excellent. Accurate kinetic pattern assessment, fairly comparable to DCE-MRI, can be obtained for benign and IDC lesions using CEUS.

Bone Segmentation Method based on Multi-Resolution using Iterative Segmentation and Registration in 3D Magnetic Resonance Image (3차원 무릎 자기공명영상 내에서 영역화와 정합 기법을 반복적으로 이용한 다중 해상도 기반의 뼈 영역화 기법)

  • Park, Sang-Hyun;Lee, Soo-Chan;Yun, Il-Dong;Lee, Sang-Uk
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.73-80
    • /
    • 2012
  • Recently, medical equipments are developed and used for diagnosis or studies. In addition, demand of techniques which automatically deal with three dimensional medical images obtained from the medical equipments is growing. One of the techniques is automatic bone segmentation which is expected to enhance the diagnosis efficiency of osteoporosis, fracture, and other bone diseases. Although various researches have been proposed to solve it, they are unable to be used in practice since a size of the medical data is large and there are many low contrast boundaries with other tissues. In this paper, we present a fast and accurate automatic framework for bone segmentation based on multi-resolutions. On a low resolution step, a position of the bone is roughly detected using constrained branch and mincut which find the optimal template from the training set. Then, the segmentation and the registration are iteratively conducted on the multiple resolutions. To evaluate the performance of the proposed method, we make an experiment with femur and tibia from 50 test knee magnetic resonance images using 100 training set. The proposed method outperformed the constrained branch and mincut in aspect of segmentation accuracy and implementation time.

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

Preoperative Detection of Hepatic Metastases from the colorectal Cancers: Comparison of Dual-phase CT scan, Mn-DPDP enhanced MRI, and combination of CT and MRI (대장암의 간 전이 진단: 이중시기 CT, Mn-DPDP 조영증강 MRI, 그리고 CT-MRI 종합 판독의 비교)

  • Shin, Kyung-Min;Kim, Jong-Yeol;Choi, Gyu-Seok;Kim, Hye-Jeong;Lee, Jong-Min;Chang, Yong-Min;Kim, Yong-Seon;Kang, Duk-Sik;Ryeom, Hun-Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • Purpose : To determine the usefulness of additional Mn-DPDP MRI for preoperative evaluation of the patients with colorectal cancers by comparison of dual-phase CT scan, Mn-DPDP enhanced MRI and combination of CT and MRI. Materials and Methods : Fifty-three colorectal cancer patients with 92 metastatic nodules underwent dualphase (arterial and portal) helical CT scan and Mn-DPDP MRI prior to surgery. The indication of MRI was presence or suspected of having metastatic lesions at CT scan and/or increased serum carcinoembryonic antigen (CEA) levels (10 ng/mL or more). The diagnosis was established by the combination of findings at surgery, intraoperative ultrasonography, and histopathologic examination. Two radiologists interpreted CT, MRI, and combination of CT-MRI at discrete sessions and evaluated each lesion for location, size, and intrinsic characteristics. The lesions were divided into three groups according to their diameter; 1cm<, 1-2 cm, and >2 cm. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method. Detection and false positive rate were also evaluated. Results : In the lesions smaller than 1 cm, detection rate of combined CT-MRI was superior to CT or MRI alone (82%, p=0.036). The mean accuracy (Az values) of combined CT and MRI was significantly higher than that of CT in the lesions smaller than 2 cm (1 cm<, p=0.034; 1-2 cm, p=0.045). However, there was no significant difference between MRI and combined CT-MRI. The false positive rate of CT was higher than those of combined CT-MR in the lesions smaller than 1 cm (28%, p=0.023). Conclusion : Additional MRI using Mn-DPDP besides routine CT scan was helpful in differentiating the hepatic lesions (<2 cm) and could improve detection of the small hepatic metastases (<1 cm) from colorectal carcinoma.

  • PDF

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF

Transient Splenial Lesions in the Splenium of Corpus Callosum in Seven Patients: MR Findings and Clinical Correlations (뇌량 팽대의 일과성 병변: 7명의 환자에서의 자기공명 영상소견과 임상 양상의 연관성)

  • Park, Ju Young;Lee, In Ho;Song, Chang June;Hwang, Hee Youn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The purpose of this study is to correlate the imaging findings and the clinical findings in patients with transient splenial lesions (TSL). Materials and Methods: Total of 7 patients (M: F = 4: 3; age range 11 - 38 years, mean age 25.5 years) were studied between November 2006 and April 2011. The MRI findings and clinical findings in all patients were retrospectively reviewed. The location, MR signal intensity, restricted diffusion, enhancement pattern and reversibility from the follow up images were reviewed. Clinical features were reviewed with respect to the presented symptoms, signs, treatment and outcome. Results: The lesions were located in the splenium of corpus callosum in all patients. All lesions showed high signal intensity on diffusion weighted imaging (DWI), and six patients showed restricted diffusion on the apparent diffusion coefficient (ADC) map. ADC map was not available in one patient. All lesions (n = 7) showed high signal intensity on the T2 weighted image (T2WI). Five of the patients (71.4%) with follow up images (range 7 - 34 days) showed complete resolution of focal high signal intensity on DWI, with recovery of ADC values as well as T2WI. After contrast media administration, none of the lesions showed any enhancements. All lesions with various etiologies including TB medication were developed in younger age patients and showed reversibility after the acceptable period of minimum 7 days with conservative treatment. Conclusion: All TSL showed nonspecific imaging findings, including restricted diffusion on DWI and ADC map on the initial images. However, reversibility of the lesions and the young age preference can be a characteristic finding of TSL with acceptable period of minimum 7 days. In addition, to keep it in mind that various etiologies including TB medication may cause TSL, is important for radiologists as well as clinicians.