• Title/Summary/Keyword: Magnetic relaxation

Search Result 275, Processing Time 0.034 seconds

Determination of the Size Distribution of Magnetite Nanoparticles from Magnetic Measurements

  • Yoon, Sung-Hyun
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.368-373
    • /
    • 2011
  • Particle size distributions in 10 nm magnetite ferrofluids are analyzed based on both dc and ac magnetic measurements. Modified log-normal distributions are used for fitting the experimental results, which allows for a proper account of the narrow distributions. The calculated average particle sizes are in good agreement with the TEM results. However the ac method gives a much narrower distribution width than that of the dc magnetization curve fit. The proposed measurements combined with the analysis methods are useful for the characterization of ferrofluids being considered for biomedical applications.

Characteristics of HTS SQUID-based Susceptometer

  • Timofeev, V.P;Kim, C.G;Shnyrkov, V.I
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.82-85
    • /
    • 1998
  • A portable HTS RF SQUID-based system, weighing less than 20 kg has been built for susceptometry applications in weak magnetic fields, It includes a YBCO sensor for measuring the axial magnetic field component with a resolution of about $7{\times}10^{-13} T/Hz^{1/2}.$ This is determined by the intrinsic magnetic noise in the quasi-white noise region. There is a relaxation for a sudden increase in field due to magnetic flux creep in HTS. In this instance the time did not exceed 3~5 minutes.

  • PDF

Comparison of Proton T1 and T2 Relaxation Times of Cerebral Metabolites between 1.5T and 3.0T MRI using a Phantom (모형을 이용한 1.5T와 3.0T 자기공명에서의 뇌 대사물질들의 수소 T1과 T2 이완시간의 비교)

  • Kim, Ji-Hoon;Chang, Kee-Hyun;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Purpose : To present the T1 and T2 relaxation times of the major cerebral metabolites at 1.5T and 3.0T and compare those between 1.5T and 3.0T. Materials and Methods : Using the phantom containing N-acetyl aspartate (NAA), Choline (Cho), and Creatine (Cr) at both 1.5T and 3.0T MRI, the T1 relaxation times were calculated from the spectral data obtained with 5000 ms repetition time (TR), 20 ms echo time (TE), and 11 different mixing time (TM)s using STEAM (STimulated Echo-Acquisition Mode) method. The T2 relaxation times were obtained from the spectral data obtained with 3000 ms TR and 5 different TEs using PRESS (Point-RESolved Spectroscopy) method. The T1 and T2 relaxation times obtained at 1.5T were compared with those of 3.0T. Results : The T1 relaxation times of NAA were $2293\;{\pm}\;48\;ms$ at 1.5T and $2559\;{\pm}\;124\;ms$ at 3.0T (11.6% increase at 3.0T). The T1 relaxation times of Cho were $2540\;{\pm}\;57\;ms$ at 1.5T and $2644\;{\pm}\;76\;ms$ at 3.0T (4.1% increase at 3.0T). The T1 relaxation times of Cr were $2543\;{\pm}\;75\;ms$ at 1.5T and $2665\;{\pm}\;94\;ms$ at 3.0T (4.8% increase). The T2 relaxation times of NAA were $526\;{\pm}\;81\;ms$ at 1.5T and $468\;{\pm}\;74\;ms$ at 3.0T (11.0% decrease at 3.0T). The T2 relaxation times of Cho were $220\;{\pm}\;44ms$ at 1.5T and $182\;{\pm}\;35\;ms$ at 3.0T (17.3% decrease at 3.0T). The T2 relaxation times of Cr were $289\;{\pm}\;47\;ms$ at 1.5T and $275\;{\pm}\;57\;ms$ at 3.0T (4.8% decrease at 3.0T). Conclusion : The T1 relaxation times of the major cerebral metabolites (NAA, Cr, Cho), which were measured at the phantom, were 4.1%-11.6% longer at 3.0T than at 1.5T. The T2 relaxation times of them were 4.8%-17.3% shorter at 3.0T than at 1.5T. To optimize MR spectroscopy at 3.0T, TR should be lengthened and TE should be shortened.

  • PDF

[ $T_2$ ]-relaxation Time Measurement of ex vivo $^1H$ MR Metabolite Peaks for Evaluation of Human Stomach Cancer

  • Mun Chi-Woong;Choi Ki-Sueng;Shin Oon-Jae;Yang Young-Ill;Chang Hee-Kyung;Hu Xiaoping;Eun Chung-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.53-58
    • /
    • 2006
  • In this study, transverse relaxation time (T2) measurement and the evaluation of the characteristics of the spectral peak related to stomach tissue metabolites were performed using ex vivo proton magnetic resonance spectroscopic imaging (MRSI) at 1.5-T MRI/S instruments. Thirty-two gastric tissues resected from 12 patients during gastric cancer surgery, of which 19 were normal tissue and 13 were cancerous tissue, were used to measure the $T_2$ of the magnetic resonance spectroscopy (MRS) peaks. The volume of interest data results from the MRSI measurements were extracted from the proper muscle (MUS) layer and the composite mucosa/submucosa (MC/SMC) layer and were statistically analyzed. MR spectra were acquired using the chemical shift imaging (CSI) point resolved spectroscopy (CSI-PRESS) technique with the parameters of pulse repetition time (TR) and echo times (TE) TR/(TE1,TE2)=1500 msec/(35 msec, 144 msec), matrix $size=24{\times}24$, NA=1, and voxel $size=2.2{\times}2.2{\times}4mm^3$. In conclusion, the measured $T_2$ of the metabolite peaks, such as choline (3.21ppm) and lipid (1.33ppm), were significantly decreased (p<0.01 and p<0.05, respectively) in the cancerous stomach tissue.

Evolution of the Magnetosphere in Response to a Sudden Ring Current Injection

  • Choe, G.S.;Park, Geun-Seok;Lee, Jung-Gi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.100.2-100.2
    • /
    • 2011
  • The dynamical evolution of the Earth's magnetosphere loaded with a transiently enhanced ring current is studied by numerical magnetohydrodynamic (MHD) simulation. Two cases with different values of the primitive ring current are considered. In one case, the initial ring current is strong enough to create a magnetic island in the magnetosphere. The magnetic island readily reconnects with the earth-connected ambient field and is destroyed as the system approaches a steady equilibrium. In the other case, the initial ring current is not so strong, and the initial magnetic field configuration bears no magnetic island, but a wake of bent field lines, which is smoothed out through the relaxing evolution of the magnetosphere. The relaxation time of the magnetosphere is found to be about five to six minutes, over which the ring current is reduced to about a quarter of its initial value. Before reaching a steady state, the magnetosphere is found to undergo an overshooting expansion and a subsequent contraction. Fast and slow magnetosonic waves are identified to play an important role in the relaxation toward equilibrium.

  • PDF

$^{1}H$ Nuclear Magnetic Relaxation in Impure $CuF_{2}.2H_{2}O$ (비자성 불순물을 갖는 $CuF_{2}.2H_{2}O$의 수소 핵자기완화 연구)

  • C. H. Lee;C. E. Lee;S. J. Noh
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.854-857
    • /
    • 1995
  • We have studied the temperature dependence of the $^{1}H$ NMR spin-lattice relaxation for the impure $CuF_{2}.2H_{2}O$ over a temperature range from 77 K to room temperature. We find that the remperature dependence of the $^{1}H$ spin-lattice relaxation is dominated by the eletron spin-flip and the Raman process of eletron spin-lattice relaxation. The electron spin-flip exchange energy was calculated to be $1.8(\pm0.04)$ K.

  • PDF

A Review on Nuclear Magnetic Resonance Logging: Simulation Schemes (자기공명반응 시뮬레이션 해설 및 비교)

  • Jang, Jae Hwa;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.97-105
    • /
    • 2013
  • Nuclear magnetic resonance (NMR) logging has become an important technique for formation evaluation, detecting interaction signals between H protons and applied magnetic fields. Measured decay signals called relaxation, contain important information about density of H protons and different decay rate due to its fluid type in the sensitive area. Thus, petrophysical information such as porosity, permeability and wettability can be estimated through the interpretation of the decay signals. Many researches on random walk simulation have been published, since a simulation method based on random walk for solving exponential decays was adapted in the early of 1950. This study first makes a review on NMR simulation researches, explains two most important methods: simulation with or without considering magnetic field gradient. Lastly, the study makes a comparison between NMR simulation responses with and without magnetic field gradient to show the importance to consider magnetic gradient to analyze the effects of magnetic gradients on NMR responses.

A Theoretical Representation of Relaxation Processes in Complex Spin System Using Liouville Space Method

  • Kyunglae Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.21-29
    • /
    • 1993
  • For the study of relaxation processes in complex spin system, a general master equation, which can be used to simulate a vast range of pulse experiments, has been formulated using the Liouville representation of quantum mechanics. The state of a nonequilibrium spin system in magnetic field is described by a density vector in Liouville space and the time evolution of the system is followed by the application of a linear master operator to the density vector in this Liouville space. In this master equation the nuclear spin relaxation due to intramolecular dipolar interaction or randomly fluctuating field interaction is explicitly implemented as a relaxation supermatrix for a strong coupled two-spin (1/2) system. The whole dynamic information inherent in the spin system is thus contained in the density vector and the master operator. The radiofrequency pulses are applied in the same space by corresponding unitary rotational supertransformations of the density vector. If the resulting FID is analytically Fourier transformed, it is possible to represent the final nonstationary spectrum using a frequency dependent spectral vector and intensity determining shape vector. The overall algorithm including relaxation interactions is then translated into an ANSIFORTRAN computer program, which can simulate a variety of two dimensional spectra. Furthermore a new strategy is tested by simulation of multiple quantum signals to differentiate the two relaxation interaction types.