• 제목/요약/키워드: Magnetic refrigeration

검색결과 47건 처리시간 0.022초

수평원관내 $CO_2$의 증발열전달 (Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube)

  • 경남수;장승일;최선묵;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Son Chang-Hyo;Kim Dae-Hui;Choi Sun-Muk;Kim Young-Ryul;Oh Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.167-174
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500kg/m^2s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greater effect on nucleate boiling than convective boiling. The evaporation heat transfer coefficient of $CO_2$ is highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But the existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

영구자석 자기력의 기계적 에너지 이용에 관한 유용성 고찰 (Proposal for the New Regeneration Energy Made by Converting Magnetic Force into Mechanical Energy)

  • 신현준;김정엽;박병직;이수각
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.158-164
    • /
    • 2016
  • Currently, identifying a new carbon-free energy resource is important in order to resolve the global warming problem. Along the same line, this paper studied how to convert magnetic force into mechanical force and a new basic mechanism of converting magnetic force into mechanical force was identified. Long-term reliability test, around 15 million times, was also conducted at $-1^{\circ}C{\sim}27^{\circ}C$ to evaluate the durability of magnetic force. As a result, tests showed that the deviation of the mechanical force was within 0.8% of the initial force, and the relation between repulsive force (P) and ambient temperature (T) was formulated in a linear equation P = -0.175T+78.945.

Magnetic Properties and Magnetocaloric Effect in Ordered Double Perovskites Sr1.8Pr0.2FeMo1-xWxO6

  • Hussain, Imad;Anwar, Mohammad Shafique;Khan, Saima Naz;Lee, Chan Gyu;Koo, Bon Heun
    • 한국재료학회지
    • /
    • 제28권8호
    • /
    • pp.445-451
    • /
    • 2018
  • We report the structural, magnetic and magnetocaloric properties of $Sr_{1.8}Pr_{0.2}FeMo_{1-x}W_xO_6$($0.0{\leq}x{\leq}0.4$) samples prepared by the conventional solid state reaction method. The X-ray diffraction analysis confirms the formation of the tetragonal double perovskite structure with a I4/mmm space group in all the synthesized samples. The temperature dependent magnetization measurements reveal that all the samples go through a ferromagnetic to paramagnetic phase transition with an increasing temperature. The Arrott plot obtained for each synthesized sample demonstrates the second order nature of the magnetic phase transition. A magnetic entropy change is obtained from the magnetic isotherms. The values of maximum magnetic entropy change and relative cooling power at an applied field of 2.5 T are found to be $0.40Jkg^{-1}K^{-1}$ and $69Jkg^{-1}$ respectively for the $Sr_{1.8}Pr_{0.2}FeMoO_6$ sample. The tunability of magnetization and excellent magnetocaloric features at low applied magnetic field make these materials attractive for use in magnetic refrigeration technology.

Reflective Electro Magnetic Energy(REME)를 이용한 공기살균시스템의 성능평가에 관한 실험적 연구 (An Experimental Study on the Air Sterilization Performance of A Reflective Electro Magnetic Energy System)

  • 홍진관;임가연
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.509-514
    • /
    • 2016
  • From the point of view to prevent airborne infection-related diseases such as H1N1, SARS, and MERS, an actual application of air cleaning and purification systems including technologies like UVGI has become increasingly important. Recently, an air purification system using REME (Reflective Electro Magnetic Energy) developed in the U.S. is applied for indoor air purification and sterilization technology to counteract the outbreak of new airborne infections. In this study, an air sterilization performance experiment using REME was carried out. The results verified that air sterilization performance in the case of installing a REME system in a medical center was 31%, namely the number of floating bacteria decreased by 31% after only a five-day operation. In addition, the number of culture collections in the REME operating air conditioning systems using nonpathogenic Geobacillus stearothemophilus as a biological indicator decreased maximally to 67%. A field application of REME technology will be useful to prevent airborne infection-related diseases, especially in response to public health crises due to the advent of emerging diseases.

The Large Magnetocaloric Effect in Amorphous Fe80-xMnxZr10 (x = 4,6,8,10) Alloys

  • Moon, Y.M.;Min, S.G;Kim, K.S.;Yu, S.C.;Kim, Y.C.;Kim, K.Y.
    • Journal of Magnetics
    • /
    • 제10권4호
    • /
    • pp.142-144
    • /
    • 2005
  • The Magnetization behaviour has been measured for amorphous $Fe_{80-x}Mn_xZr_{10}$ (x = 4,6,8,10) alloys. The Curie temperature decreased from 236 K to 195 K with increasing Mn concentration (x = 4 to x = 10). The magnetization measurements were conducted at temperatures above the Curie temperature in the paramagnetic region. In all samples, the magnetic properties showed superparamagnetic behavior above $T_c$ where the mean magnetic moment of the superparamagnetic spin clusters decreased with increasing temperature. A large magnetic entropy change, ${\Delta}S_M$, which is calculated from H vs M curves associated with the ferromagnetic-paramagnetic transitions in amorphous, has been observed. With Mn concentration increasing, ${\Delta}S_M$ decreases 1.04, 0.95, 0.87 J/kg K at 222, 210, 195 K (the Curie temperature), respectively.

마이크로핀관 증발기내 전열 성능에 미치는 냉동기유의 영향 (Effect of refrigeration lubricants on the heat transfer performance in the microfin tube evaporator)

  • 조금남;태상진
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.61-72
    • /
    • 1999
  • The present study experimentally investigated the effect of refrigeration lubricant on the heat transfer performance in the straight sections and U-bend of a microfin tube evaporator by using R-22/mineral oil and R-407C/POE oil. The apparatus consisted of test section with U-bend, preheater, condenser, oil injection and sampling devices, magnetic pump, mass flow meter etc. The experimental parameters were oil concentration of 0 to 5 wt%, inlet quality of 0.1 to 0.5, mass flux of 219 and $400kg/m^2s$ and heat flux of 10 and $20kW/m^2$. The effects of parameters on the heat transfer coefficients were large in the order of inlet quality, mass flux and heat flux as oil concentration got increased. As oil concentration was increased, heat transfer coefficients were continuously decreased for R-22 and increased by 3% up to the concentration of 1% and then decreased for R-407C under the condition of large inlet quality, and small mass flux and heat flux. But, the heat transfer coefficients were increased up to the concentration of 3% and then decreased for both R-22 and R-407C refrigerants under the opposite conditions. The variation of enhancement factors for R-407C was under 50% of that for R-22 and the variation with respect to the positions in the test section was small. The pressure drops were increased for both R-22 and R-407C refrigerants as oil concentration was increased. The pressure drops for R-407C were smaller by the maximum of 18% than those for R-22.

  • PDF

천문관측을 위한 극저온 발생장치 개발

  • 김동락;정원묵;양형석
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2003년도 한국우주과학회보 제12권2호
    • /
    • pp.67-67
    • /
    • 2003
  • 적외선 고감도천문관측 등 우주탑재체에서의 천문관측에서는 망원경 또는 관측용 센서를 4K 또는 그 이하로 냉각하여 고감도 관측을 하고 있다. 이와 관련하여 액체헬륨-4, 초유동헬륨, 액체헬륨-3, magnetic cooling 또는 dilution refrigeration 등의 방법으로 4K∼0.05K 영역까지의 극저온을 얻을 수 있다 우주탑재체에서의 극저온을 발생하는 방법과 본 연구실에서 개발 중인 ∼1K 까지의 극저온 발생장치의 설계 등에 관하여 논의한다.

  • PDF

Large Magnetic Entropy Change in La0.55Ce0.2Ca0.25MnO3 Perovskite

  • Anwar, M.S.;Kumar, Shalendra;Ahmed, Faheem;Arshi, Nishat;Kim, G.W.;Lee, C.G.;Koo, Bon-Heun
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.457-460
    • /
    • 2011
  • In this paper, magnetic property and magnetocaloric effect (MCE) in perovskite manganites of the type $La_{(0.75-X)}Ce_XCa_{0.25}MnO_3$ (x = 0.0, 0.2, 0.3 and 0.5) synthesized by using the standard solid state reaction method have been reported. From the magnetic measurements as a function of temperature and applied magnetic field, we have observed that the Curie temperature ($T_C$) of the prepared samples strongly dependent on Ce content and was found to be 255, 213 and 150 K for x = 0.0, 0.2 and 0.3, respectively. A large magnetocaloric effect in vicinity of $T_C$ has been observed with a maximum magnetic entropy change (${\mid}{\Delta}S_M{\mid}_{max}$) of 3.31 and 6.40 J/kgK at 1.5 and 4 T, respectively, for $La_{0.55}Ce_{0.2}Ca_{0.25}MnO_3$. In addition, relative cooling power (RCP) of the sample under the magnetic field variation of 1.5 T reaches 59 J/kg. These results suggest that $La_{0.55}Ce_{0.2}Ca_{0.25}MnO_3$ compound could be a suitable candidate as working substance in magnetic refrigeration at 213 K.